Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 3.992
Filter
3.
Eur J Gastroenterol Hepatol ; 36(7): 845-849, 2024 Jul 01.
Article in English | MEDLINE | ID: mdl-38829942

ABSTRACT

BACKGROUND: Meckel diverticulum (MD) is an important cause of gastrointestinal bleeding in children. Small bowel capsule endoscopy (SBCE) is a first-line examination method applied to patients with obscure gastrointestinal bleeding, but there are few studies on its application in children with MD. This article aims to provide evidence in favor of the auxiliary diagnosis of MD in children by analyzing its characteristics using SBCE. METHODS: We retrospectively collected the clinical data of patients with suspected MD. RESULTS: A total of 58 children were included in this study. All 58 children presented overt gastrointestinal bleeding (bloody stool or melena). Capsule endoscopy identified protruding lesions in 2 cases, double-lumen changes in 30 cases (all considered as MD), vascular lesions in 7 cases, intestinal mucosal inflammatory lesions in 3 cases, ulcers or erosion in 3 cases, and no obvious abnormalities in SBCE in 12 cases. Both SBCE and technetium-99 scans were performed for 24 cases, 22 of which were diagnosed MD by their combined results, giving a diagnostic coincidence rate of 91.7%. Eight cases were highly suspected as MD but were negative for the technetium-99 scan and positive for SBCE. CONCLUSION: SBCE has high accuracy in the diagnosis of MD in children, especially when performed in combination with a technetium-99 scan, which can greatly improve the diagnostic rate of MD in children.


Subject(s)
Capsule Endoscopy , Gastrointestinal Hemorrhage , Meckel Diverticulum , Humans , Meckel Diverticulum/complications , Meckel Diverticulum/diagnostic imaging , Meckel Diverticulum/diagnosis , Capsule Endoscopy/methods , Male , Female , Retrospective Studies , Child , Child, Preschool , Gastrointestinal Hemorrhage/etiology , Adolescent , Infant , Intestine, Small/diagnostic imaging , Intestine, Small/pathology , Predictive Value of Tests , Radionuclide Imaging , Radiopharmaceuticals
6.
Curr Med Imaging ; 20(1): e15734056267653, 2024.
Article in English | MEDLINE | ID: mdl-38874039

ABSTRACT

BACKGROUND: Magnetic resonance enteroclysis (MRE) has been widely applied to diagnose Crohn's disease (CD). Magnetic resonance (MR) at 3.0 T improves signal-to-noise ratio (SNR), shortens image acquisition time, and shows more advantages. OBJECTIVE: This study aimed to retrospectively analyze the diagnostic value of 3.0 T MR imaging for active CD. METHODS: 48 CD patients hospitalized in our hospital from January 2021 to December 2022 were selected as the study subjects. These 48 CD patients underwent both double-balloon enteroscopy and 3.0 T MRE. All patients' arterial phase signal, venous phase signal, bowel wall, and bowel lumen of MRE were observed to identify whether they suffered from active CD. Based on the results of enteroscopy, the number of true positives, true negatives, false negatives, and false positives diagnosed by MRE were screened; next, the diagnostic accuracy, sensitivity, and specificity of MRE in assessing active CD were calculated. RESULTS: Of the 48 patients, 39 were diagnosed with small bowel CD by MRE, which was not significantly different from the results of enteroscopy (P>0.05). According to MRE diagnostic results, the arterial phase predominantly presented high signal intensity, and the venous phase mainly presented low signal intensity or isointensity. Small bowel CD lesions were primarily characterized by bowel wall thickening, rare pneumatosis enhancement of the bowel wall, bowel lumen pneumatosis or dilatation, and rare strictures. Besides, MRE presented an accuracy of 93.75%, sensitivity of 97.37%, and specificity of 80.00% in diagnosing CD. CONCLUSION: 3.0 T MR imaging has diagnostic value for active CD and shows certain clinical application value.

.


Subject(s)
Crohn Disease , Magnetic Resonance Imaging , Sensitivity and Specificity , Humans , Crohn Disease/diagnostic imaging , Magnetic Resonance Imaging/methods , Male , Female , Adult , Retrospective Studies , Middle Aged , Young Adult , Signal-To-Noise Ratio , Adolescent , Double-Balloon Enteroscopy/methods , Intestine, Small/diagnostic imaging
7.
PLoS One ; 19(5): e0295774, 2024.
Article in English | MEDLINE | ID: mdl-38713694

ABSTRACT

BACKGROUND: Magnetically assisted capsule endoscopy (MACE) showed the feasibility for upper gastrointestinal examination. To further enhance the performance of conventional MACE, it is necessary to provide quality-improved and three-dimensional images. The aim of this clinical study was to determine the efficacy and safety of novel three-dimensional MACE (3D MACE) for upper gastrointestinal and small bowel examination at once. METHODS: This was a prospective, single-center, non-randomized, and sequential examination study (KCT0007114) at Dongguk University Ilsan Hospital. Adult patients who visited for upper endoscopy were included. The study protocol was conducted in two stages. First, upper gastrointestinal examination was performed using 3D MACE, and a continuous small bowel examination was performed by conventional method of capsule endoscopy. Two hours later, an upper endoscopy was performed for comparison with 3D MACE examination. The primary outcome was confirmation of major gastric structures (esophagogastric junction, cardia/fundus, body, angle, antrum, and pylorus). Secondary outcomes were confirmation of esophagus and duodenal bulb, accuracy for gastric lesions, completion of small bowel examination, 3D image reconstruction of gastric lesion, and safety. RESULTS: Fifty-five patients were finally enrolled. The examination time of 3D MACE was 14.84 ± 3.02 minutes and upper endoscopy was 5.22 ± 2.39 minutes. The confirmation rate of the six major gastric structures was 98.6% in 3D MACE and 100% in upper endoscopy. Gastric lesions were identified in 43 patients during 3D MACE, and 40 patients during upper endoscopy (Sensitivity 0.97). 3D reconstructed images were acquired for all lesions inspected by 3D MACE. The continuous small bowel examination by 3D MACE was completed in 94.5%. 3D MACE showed better overall satisfaction (3D MACE 9.55 ± 0.79 and upper endoscopy 7.75 ± 2.34, p<0.0001). There were no aspiration or significant adverse event or capsule retention in the 3D MACE examination. CONCLUSIONS: Novel 3D MACE system is more advanced diagnostic modality than the conventional MACE. And it is possible to perform serial upper gastrointestinal and small bowel examination as a non-invasive and one-step test. It would be also served as a bridge to pan-endoscopy.


Subject(s)
Capsule Endoscopy , Imaging, Three-Dimensional , Intestine, Small , Humans , Capsule Endoscopy/methods , Capsule Endoscopy/adverse effects , Male , Female , Intestine, Small/diagnostic imaging , Intestine, Small/pathology , Middle Aged , Imaging, Three-Dimensional/methods , Prospective Studies , Adult , Aged , Upper Gastrointestinal Tract/diagnostic imaging , Upper Gastrointestinal Tract/pathology
8.
Medicine (Baltimore) ; 103(20): e38119, 2024 May 17.
Article in English | MEDLINE | ID: mdl-38758917

ABSTRACT

Device assisted enteroscopy (DAE) like the double balloon enteroscopy (DBE) and single balloon enteroscopy (SBE) are postulated to ease small bowel examination and performance of therapy. However, studies comparing the effectiveness of these 2 modalities have yielded varying results. The aim of this study is to compare the efficacy and safety of SBE and DBE. We retrospectively reviewed records of patients who underwent DBE (n = 82) or SBE (n = 45) for small bowel exam in our unit from January 2014 to January 2022. Our primary outcomes were to compare the technical success and diagnostic success rates between DBE and SBE. Our secondary outcomes were to compare the therapeutic success, and complication rates. The main indications were suspected GI bleeding (DBE 41.5% vs SBE 48.9%), iron deficiency anemia (DBE 9.8% vs SBE 4.4%) and small bowel lesions (DBE 28.0% vs SBE 44.4%) detected either from prior capsule endoscopy or radiological imaging. Majority of the enteroscopy exam was by antegrade approach (DBE 67.1% vs SBE 77.8%). We found no significant difference in the technical success (DBE 95.1% vs SBE 97.8%, P = .46), diagnostic success (DBE 69.5% vs SBE 77.8%, P = .36) and the therapeutic success rate (DBE 63.2% vs SBE 54.3%, P = .09) between the groups. Complications occurred in 1 case from each group (mucosal tear). None of the complications were major. In patients who underwent enteroscopy, the diagnostic and therapeutic performance of SBE is similar to DBE. Both procedures were safe with low complication rates.


Subject(s)
Double-Balloon Enteroscopy , Gastrointestinal Hemorrhage , Intestine, Small , Single-Balloon Enteroscopy , Humans , Double-Balloon Enteroscopy/methods , Double-Balloon Enteroscopy/adverse effects , Female , Retrospective Studies , Male , Middle Aged , Single-Balloon Enteroscopy/methods , Intestine, Small/diagnostic imaging , Adult , Gastrointestinal Hemorrhage/diagnosis , Aged , Intestinal Diseases/diagnosis , Intestinal Diseases/diagnostic imaging , Anemia, Iron-Deficiency/diagnosis
9.
World J Gastroenterol ; 30(18): 2482-2484, 2024 May 14.
Article in English | MEDLINE | ID: mdl-38764765

ABSTRACT

The present letter to the editor is related to the study with the title "Automatic detection of small bowel (SB) lesions with different bleeding risk based on deep learning models". Capsule endoscopy (CE) is the main tool to assess SB diseases but it is a time-consuming procedure with a significant error rate. The development of artificial intelligence (AI) in CE could simplify physicians' tasks. The novel deep learning model by Zhang et al seems to be able to identify various SB lesions and their bleeding risk, and it could pave the way to next perspective studies to better enhance the diagnostic support of AI in the detection of different types of SB lesions in clinical practice.


Subject(s)
Artificial Intelligence , Capsule Endoscopy , Deep Learning , Gastrointestinal Hemorrhage , Intestine, Small , Humans , Capsule Endoscopy/methods , Gastrointestinal Hemorrhage/etiology , Gastrointestinal Hemorrhage/diagnosis , Intestine, Small/pathology , Intestine, Small/diagnostic imaging , Risk Assessment/methods
10.
World J Gastroenterol ; 30(10): 1270-1279, 2024 Mar 14.
Article in English | MEDLINE | ID: mdl-38596501

ABSTRACT

In 2000, the small bowel capsule revolutionized the management of patients with small bowel disorders. Currently, the technological development achieved by the new models of double-headed endoscopic capsules, as miniaturized devices to evaluate the small bowel and colon [pan-intestinal capsule endoscopy (PCE)], makes this non-invasive procedure a disruptive concept for the management of patients with digestive disorders. This technology is expected to identify which patients will require conventional invasive endoscopic procedures (colonoscopy or balloon-assisted enteroscopy), based on the lesions detected by the capsule, i.e., those with an indication for biopsies or endoscopic treatment. The use of PCE in patients with inflammatory bowel diseases, namely Crohn's disease, as well as in patients with iron deficiency anaemia and/or overt gastrointestinal (GI) bleeding, after a non-diagnostic upper endoscopy (esophagogastroduodenoscopy), enables an effective, safe and comfortable way to identify patients with relevant lesions, who should undergo subsequent invasive endoscopic procedures. The recent development of magnetically controlled capsule endoscopy to evaluate the upper GI tract, is a further step towards the possibility of an entirely non-invasive assessment of all the segments of the digestive tract, from mouth-to-anus, meeting the expectations of the early developers of capsule endoscopy.


Subject(s)
Capsule Endoscopy , Crohn Disease , Intestinal Diseases , Humans , Capsule Endoscopy/adverse effects , Capsule Endoscopy/methods , Endoscopy, Gastrointestinal/adverse effects , Endoscopy, Gastrointestinal/methods , Intestinal Diseases/pathology , Crohn Disease/diagnosis , Intestine, Small/diagnostic imaging , Intestine, Small/surgery , Intestine, Small/pathology , Gastrointestinal Hemorrhage/etiology , Gastrointestinal Hemorrhage/diagnosis
11.
Dig Dis Sci ; 69(6): 2140-2146, 2024 Jun.
Article in English | MEDLINE | ID: mdl-38637455

ABSTRACT

BACKGROUND AND AIMS: Small bowel gastrointestinal bleeding (GIB) is associated with multiple blood transfusions, prolonged and/or multiple hospital admissions, utilization of significant healthcare resources, and negative effects on patient quality of life. There is a well-recognized association between antithrombotic medications and small bowel GIB. We aimed to identify the diagnostic yield of small bowel capsule endoscopy (SBCE) in patients on antithrombotic medications and the impact of SBCE on treatment course. METHODS: The electronic medical records of nineteen hundred eighty-six patients undergoing SBCE were retrospectively reviewed. RESULTS: The diagnostic yield for detecting stigmata of recent bleeding and/or actively bleeding lesions in SBCE was higher in patients that were on antiplatelet agents (21.6%), patients on anticoagulation (22.5%), and in patients that had their SBCE performed while they were inpatient (21.8%), when compared to the patients not on antiplatelet agents (12.1%), patients not on anticoagulation (13.5%), and with patients that had their SBCE performed in the outpatient setting (12%). Of 318 patients who had stigmata of recent bleeding and/or actively bleeding lesion(s) identified on SBCE, SBCE findings prompted endoscopic evaluation (small bowel enteroscopy, esophagogastroduodenoscopy (EGD), and/or colonoscopy) in 25.2%, with endoscopic hemostasis attempted in 52.5%. CONCLUSIONS: Our study, the largest conducted to date, emphasizes the importance of performing SBCE as part of the evaluation for suspected small bowel bleeding, particularly in patients taking antithrombotic therapy, and especially during their inpatient hospital stay.


Subject(s)
Capsule Endoscopy , Fibrinolytic Agents , Gastrointestinal Hemorrhage , Intestine, Small , Humans , Capsule Endoscopy/methods , Male , Female , Retrospective Studies , Aged , Middle Aged , Intestine, Small/pathology , Intestine, Small/diagnostic imaging , Fibrinolytic Agents/adverse effects , Fibrinolytic Agents/therapeutic use , Platelet Aggregation Inhibitors/adverse effects , Anticoagulants/adverse effects , Aged, 80 and over
12.
Ann Surg Oncol ; 31(7): 4189-4196, 2024 Jul.
Article in English | MEDLINE | ID: mdl-38652200

ABSTRACT

BACKGROUND: Radio-guided surgery (RGS) holds promise for improving surgical outcomes in neuroendocrine tumors (NETs). Previous studies showed low specificity (SP) using γ-probes to detect radiation emitted by radio-labeled somatostatin analogs. OBJECTIVE: We aimed to assess the sensitivity (SE) and SP of the intraoperative RGS approach using a ß-probe with a per-lesion analysis, while assessing safety and feasibility as secondary objectives. METHODS: This prospective, single-arm, single-center, phase II trial (NCT05448157) enrolled 20 patients diagnosed with small intestine NETs (SI-NETs) with positive lesions detected at 68Ga-DOTA-TOC positron emission tomography/computed tomography (PET/CT). Patients received an intravenous injection of 1.1 MBq/Kg of 68Ga-DOTA-TOC 10 min prior to surgery. In vivo measurements were conducted using a ß-probe. Receiver operating characteristic (ROC) analysis was performed, with the tumor-to-background ratio (TBR) as the independent variable and pathology result (cancer vs. non-cancer) as the dependent variable. The area under the curve (AUC), optimal TBR, and absorbed dose for the surgery staff were reported. RESULTS: The intraoperative RGS approach was feasible in all cases without adverse effects. Of 134 specimens, the AUC was 0.928, with a TBR cut-off of 1.35 yielding 89.3% SE and 86.4% SP. The median absorbed dose for the surgery staff was 30 µSv (range 12-41 µSv). CONCLUSION: This study reports optimal accuracy in detecting lesions of SI-NETs using the intraoperative RGS approach with a novel ß-probe. The method was found to be safe, feasible, and easily reproducible in daily clinical practice, with minimal radiation exposure for the staff. RGS might potentially improve radical resection rates in SI-NETs. CLINICAL TRIALS REGISTRATION: 68Ga-DOTATOC Radio-Guided Surgery with ß-Probe in GEP-NET (RGS GEP-NET) [NCT0544815; https://classic. CLINICALTRIALS: gov/ct2/show/NCT05448157 ].


Subject(s)
Intestinal Neoplasms , Intestine, Small , Neuroendocrine Tumors , Octreotide , Positron Emission Tomography Computed Tomography , Radiopharmaceuticals , Surgery, Computer-Assisted , Humans , Neuroendocrine Tumors/surgery , Neuroendocrine Tumors/pathology , Neuroendocrine Tumors/diagnostic imaging , Female , Male , Prospective Studies , Middle Aged , Intestinal Neoplasms/surgery , Intestinal Neoplasms/pathology , Intestinal Neoplasms/diagnostic imaging , Positron Emission Tomography Computed Tomography/methods , Aged , Intestine, Small/pathology , Intestine, Small/diagnostic imaging , Intestine, Small/surgery , Octreotide/analogs & derivatives , Adult , Surgery, Computer-Assisted/methods , Organometallic Compounds , Somatostatin/analogs & derivatives , Follow-Up Studies , Prognosis , Beta Particles/therapeutic use , Feasibility Studies
13.
Lancet Digit Health ; 6(5): e345-e353, 2024 May.
Article in English | MEDLINE | ID: mdl-38670743

ABSTRACT

BACKGROUND: Capsule endoscopy reading is time consuming, and readers are required to maintain attention so as not to miss significant findings. Deep convolutional neural networks can recognise relevant findings, possibly exceeding human performances and reducing the reading time of capsule endoscopy. Our primary aim was to assess the non-inferiority of artificial intelligence (AI)-assisted reading versus standard reading for potentially small bowel bleeding lesions (high P2, moderate P1; Saurin classification) at per-patient analysis. The mean reading time in both reading modalities was evaluated among the secondary endpoints. METHODS: Patients aged 18 years or older with suspected small bowel bleeding (with anaemia with or without melena or haematochezia, and negative bidirectional endoscopy) were prospectively enrolled at 14 European centres. Patients underwent small bowel capsule endoscopy with the Navicam SB system (Ankon, China), which is provided with a deep neural network-based AI system (ProScan) for automatic detection of lesions. Initial reading was performed in standard reading mode. Second blinded reading was performed with AI assistance (the AI operated a first-automated reading, and only AI-selected images were assessed by human readers). The primary endpoint was to assess the non-inferiority of AI-assisted reading versus standard reading in the detection (diagnostic yield) of potentially small bowel bleeding P1 and P2 lesions in a per-patient analysis. This study is registered with ClinicalTrials.gov, NCT04821349. FINDINGS: From Feb 17, 2021 to Dec 29, 2021, 137 patients were prospectively enrolled. 133 patients were included in the final analysis (73 [55%] female, mean age 66·5 years [SD 14·4]; 112 [84%] completed capsule endoscopy). At per-patient analysis, the diagnostic yield of P1 and P2 lesions in AI-assisted reading (98 [73·7%] of 133 lesions) was non-inferior (p<0·0001) and superior (p=0·0213) to standard reading (82 [62·4%] of 133; 95% CI 3·6-19·0). Mean small bowel reading time was 33·7 min (SD 22·9) in standard reading and 3·8 min (3·3) in AI-assisted reading (p<0·0001). INTERPRETATION: AI-assisted reading might provide more accurate and faster detection of clinically relevant small bowel bleeding lesions than standard reading. FUNDING: ANKON Technologies, China and AnX Robotica, USA provided the NaviCam SB system.


Subject(s)
Artificial Intelligence , Capsule Endoscopy , Gastrointestinal Hemorrhage , Intestine, Small , Humans , Capsule Endoscopy/methods , Gastrointestinal Hemorrhage/diagnosis , Prospective Studies , Female , Male , Middle Aged , Intestine, Small/diagnostic imaging , Intestine, Small/pathology , Aged , Adult , Aged, 80 and over , Neural Networks, Computer
14.
Clin Res Hepatol Gastroenterol ; 48(5): 102334, 2024 May.
Article in English | MEDLINE | ID: mdl-38582328

ABSTRACT

BACKGROUND: In order to overcome the challenges of lesion detection in capsule endoscopy (CE), we improved the YOLOv5-based deep learning algorithm and established the CE-YOLOv5 algorithm to identify small bowel lesions captured by CE. METHODS: A total of 124,678 typical abnormal images from 1,452 patients were enrolled to train the CE-YOLOv5 model. Then 298 patients with suspected small bowel lesions detected by CE were prospectively enrolled in the testing phase of the study. Small bowel images and videos from the above 298 patients were interpreted by the experts, non-experts and CE-YOLOv5, respectively. RESULTS: The sensitivity of CE-YOLOv5 in diagnosing vascular lesions, ulcerated/erosive lesions, protruding lesions, parasite, diverticulum, active bleeding and villous lesions based on CE videos was 91.9 %, 92.2 %, 91.4 %, 93.1 %, 93.3 %, 95.1 %, and 100 % respectively. Furthermore, CE-YOLOv5 achieved specificity and accuracy of more than 90 % for all lesions. Compared with experts, the CE-YOLOv5 showed comparable overall sensitivity, specificity and accuracy (all P > 0.05). Compared with non-experts, the CE-YOLOv5 showed significantly higher overall sensitivity (P < 0.0001) and overall accuracy (P < 0.0001), and a moderately higher overall specificity (P = 0.0351). Furthermore, the time for AI-reading (5.62 ± 2.81 min) was significantly shorter than that for the other two groups (both P < 0.0001). CONCLUSIONS: CE-YOLOv5 diagnosed small bowel lesions in CE videos with high sensitivity, specificity and accuracy, providing a reliable approach for automated lesion detection in real-world clinical practice.


Subject(s)
Capsule Endoscopy , Deep Learning , Intestine, Small , Capsule Endoscopy/methods , Humans , Intestine, Small/diagnostic imaging , Intestine, Small/pathology , Female , Male , Middle Aged , Prospective Studies , Adult , Intestinal Diseases/diagnostic imaging , Intestinal Diseases/diagnosis , Aged , Sensitivity and Specificity , Algorithms
15.
J Neuroendocrinol ; 36(5): e13391, 2024 05.
Article in English | MEDLINE | ID: mdl-38590270

ABSTRACT

Metastases outside the liver and abdominal/retroperitoneal lymph nodes are nowadays detected frequently in patients with neuroendocrine tumours (NETs), owing to the high sensitivity of positron emission tomography (PET) with Gallium-68-DOTA-somatostatin analogues (68Ga-SSA) and concomitant diagnostic computed tomography (CT). Our aim was to determine the prevalence of extra-abdominal metastases on 68Ga-DOTATOC-PET/CT in a cohort of patients with small intestinal (Si-NET) and pancreatic NET (Pan-NET), as well as that of pancreatic metastasis in patients with Si-NET. Among 2090 patients examined by 68Ga-DOTATOC-PET/CT at two tertiary referral centres, a total of 1177 patients with a history of Si- or Pan-NET, were identified. The most recent 68Ga-DOTATOC-PET/CT report for each patient was reviewed, and the location and number of metastases of interest were recorded. Lesions outside the liver and abdominal nodes were found in 26% of patients (n = 310/1177), of whom 21.5% (255/1177) were diagnosed with Si-NET and 4.5% (55/1177) Pan-NET. Bone metastases were found in 18.4% (215/1177), metastases to Virchow's lymph node in 7.1% (83/1177), and lung/pleura in 4.8% (56/1177). In the subset of 255 Si-NET patients, 5.4% (41/255) manifested lesions in the pancreas, 1.5% in the breast (18/255), 1.3% in the heart (15/255) and 1% in the orbita (12/255). In Si-NET patients, the Ki-67 proliferation index was higher in those with ≥2 metastatic sites of interest, than with 1 metastatic site, (p <0.001). Overall, extra-abdominal or pancreatic metastases were more often found in patients with Si-NET (34%) than in those with Pan-NET (13%) (p <0.001). Bone metastases were 2.6 times more frequent in patients with Si-NET compared to Pan-NET patients (p <0.001). Lesions to the breast and orbita were encountered in almost only Si-NET patients. In conclusion, lesions outside the liver and abdominal nodes were detected in as many as 26% of the patients, with different prevalence and metastatic patterns in patients with Si-NET compared to Pan-NET. The impact of such metastases on overall survival and clinical decision-making needs further evaluation.


Subject(s)
Intestinal Neoplasms , Lymphatic Metastasis , Neuroendocrine Tumors , Octreotide , Organometallic Compounds , Pancreatic Neoplasms , Positron Emission Tomography Computed Tomography , Adult , Aged , Aged, 80 and over , Female , Humans , Male , Middle Aged , Intestinal Neoplasms/epidemiology , Intestinal Neoplasms/pathology , Intestinal Neoplasms/diagnostic imaging , Intestine, Small/diagnostic imaging , Intestine, Small/pathology , Lymph Nodes/pathology , Lymph Nodes/diagnostic imaging , Lymphatic Metastasis/diagnostic imaging , Lymphatic Metastasis/pathology , Neuroendocrine Tumors/pathology , Neuroendocrine Tumors/epidemiology , Neuroendocrine Tumors/diagnostic imaging , Octreotide/analogs & derivatives , Pancreatic Neoplasms/pathology , Pancreatic Neoplasms/epidemiology , Pancreatic Neoplasms/diagnostic imaging , Prevalence , Retrospective Studies
16.
Am J Case Rep ; 25: e942838, 2024 Apr 08.
Article in English | MEDLINE | ID: mdl-38584385

ABSTRACT

BACKGROUND Maldevelopment of the fetal bowel can result in the rare condition of intestinal atresia, which results in congenital bowel obstruction. This report describes a case of prenatal diagnosis of fetal ileal atresia at 22 weeks' gestation. CASE REPORT Here, we present a 24-year old woman who was 22 weeks into her first pregnancy when she underwent routine fetal ultrasound. She was diagnosed with gestational diabetes mellitus. Her body mass index was normal and she had normal weight gain. The ultrasonographic examination performed revealed a hyperechoic bowel and a small dilatation of the bowel. The couple was counselled for possible intestinal atresia and its postnatal implications. At 33 weeks of gestation, polyhydramnios appeared, and the intestinal distension was much more pronounced, with hyperechoic debris in the intestinal lumen (succus-entericus). After birth, surgery was performed and we concluded the patient had type II atresia, which was surgically treated. CONCLUSIONS This report has highlighted the importance of antenatal ultrasound in detecting fetal abnormalities, and has shown that rare conditions such as intestinal atresia can be accurately diagnosed and successfully managed. Surgical correction, if implemented promptly after stabilizing the general condition, can have a relatively good prognosis. Coexisting fetal ileal atresia and gestational diabetes mellitus are rare occurrences, which can make each condition even more difficult to treat.


Subject(s)
Diabetes, Gestational , Intestinal Atresia , Intestine, Small/abnormalities , Humans , Female , Pregnancy , Young Adult , Adult , Diabetes, Gestational/diagnosis , Intestinal Atresia/diagnostic imaging , Intestinal Atresia/surgery , Intestine, Small/diagnostic imaging , Prenatal Diagnosis , Ultrasonography, Prenatal/methods
17.
Abdom Radiol (NY) ; 49(6): 2083-2097, 2024 Jun.
Article in English | MEDLINE | ID: mdl-38441632

ABSTRACT

Patients with Crohn's disease (CD) are at increased risk of developing small bowel cancer, since chronic inflammation may trigger the histopathological sequence that begins from low-grade dysplasia of the intestinal epithelium and may eventually lead to malignant transformation. Owing to their location in a portion of the gastrointestinal tract which is not easily accessible to conventional endoscopic techniques, the detection of CD-related small bowel cancers is still a clinical challenge. The radiological features of CD-related small bowel adenocarcinoma (SBA) in patients with CD have been described in some previous studies, including its appearance in both CT and MRI examinations. Radiological signs of active or fibrostenotic CD may be intermixed with those suggesting the presence of CD-related SBA. In CT studies, the most relevant findings consistent with malignant transformation are the presence of a stricture with irregular asymmetric thickening of small bowel walls, loss of mural stratification, and moderate enhancement after intravenous administration of iodinated contrast media, in association with enlarged adjacent mesenteric lymph nodes. Many of the CD-related SBA features that can be observed on CT imaging are similar to those detectable by MRI. This latter modality provides the additional value of the functional characterization of small bowel strictures, thereby helping to distinguish between inflammatory, fibrotic, and malignant stenosis in the setting of active CD. Positron Emission Tomography (PET)/CT enables the metabolic assessment of enlarged mesenteric lymph nodes, and PET/MRI fusion imaging can incorporate morphological, functional and metabolic information into a single set of imaging data, thus overcoming the limitations of the separate assessment of each individual modality. Owing to the low incidence and prevalence of this long-term complication of CD, we believe that a detailed multimodality pictorial essay on this topic, also including the PET-CT and fusion imaging documentation of some cases, would be useful to the medical literature.


Subject(s)
Crohn Disease , Intestinal Neoplasms , Intestine, Small , Multimodal Imaging , Humans , Crohn Disease/diagnostic imaging , Crohn Disease/complications , Multimodal Imaging/methods , Intestine, Small/diagnostic imaging , Intestinal Neoplasms/diagnostic imaging , Magnetic Resonance Imaging/methods , Adenocarcinoma/diagnostic imaging
18.
J Biophotonics ; 17(6): e202300438, 2024 Jun.
Article in English | MEDLINE | ID: mdl-38468556

ABSTRACT

The near-infrared spectroscopy is often used to distinguish small bowel necrosis due to necrotizing enterocolitis (NEC). The characteristic bands of small bowel necrosis, as an important basis for evaluating the confidence of the differentiation results, are challenging to identify quickly. In this study, we proposed to identify characteristic bands of lesion samples based on hyperspectral imaging (HSI) and cellwise outlier detection. Rabbits were used as an animal model to simulate the clinical symptoms of NEC. The rabbits were detected at intervals of 10, 30, 60, and 90 min. The characteristic bands were identified within the same rabbit, between different rabbits and at different times. The result showed the bands near 763 nm, corresponding to the absorption peak of deoxyhemoglobin, were the characteristic bands separating samples with NEC. The identification result was plausible because hypoxia was the main cause of NEC. The method was easy to perform.


Subject(s)
Algorithms , Enterocolitis, Necrotizing , Intestine, Small , Necrosis , Spectroscopy, Near-Infrared , Animals , Rabbits , Intestine, Small/pathology , Intestine, Small/diagnostic imaging , Enterocolitis, Necrotizing/pathology , Enterocolitis, Necrotizing/diagnostic imaging , Hyperspectral Imaging
20.
Vet Radiol Ultrasound ; 65(3): 264-274, 2024 May.
Article in English | MEDLINE | ID: mdl-38436052

ABSTRACT

Small intestinal obstruction in rabbits, although demonstrated to be common, is still poorly characterized. The objective of this study was to report features of small intestinal obstruction caused by trichobezoars in rabbits upon CT and their clinical outcomes. Rabbits with a diagnosis of intestinal obstruction that underwent CT scanning were included in this study. From each CT scan, obstruction location, appearance, Hounsfield units, size (mm), volume (mm3), distance from the stomach, and diameter of the small intestine proximal and distal to it, were extracted. Nine rabbits were included in the study. All rabbits presented for anorexia and had a distended or enlarged stomach (7) or abdomen (2). CT scan showed a non-contrast-enhancing, ovoid, smoothly marginated structure with a hyperattenuating rim, heterogeneous center, and variable amount of centrally located gas, in the duodenum (5), the jejunum (2), or the ileum (2). The density of the trichobezoars ranged from -156 to 58 HU (median, -44 HU) and volume ranged from 86.1 to 633.8 mm3 (median, 320.6 mm3). Three rabbits underwent medical management. Two of them survived, and one of them died. Six rabbits underwent surgery, of which three were successfully discharged from the hospital. CT proved to be a valuable imaging modality in rabbits with a suspected intestinal obstruction to provide the exact location of the obstruction and the characteristics of the obstructive material. The location and size of the trichobezoar may have relevant clinical implications.


Subject(s)
Bezoars , Intestinal Obstruction , Intestine, Small , Tomography, X-Ray Computed , Animals , Rabbits , Intestinal Obstruction/veterinary , Intestinal Obstruction/diagnostic imaging , Intestinal Obstruction/etiology , Intestinal Obstruction/surgery , Bezoars/veterinary , Bezoars/diagnostic imaging , Bezoars/complications , Tomography, X-Ray Computed/veterinary , Female , Intestine, Small/diagnostic imaging , Male
SELECTION OF CITATIONS
SEARCH DETAIL
...