Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 2.558
Filter
1.
Radiat Oncol ; 19(1): 86, 2024 Jul 02.
Article in English | MEDLINE | ID: mdl-38956685

ABSTRACT

PURPOSE: To apply an independent GPU-accelerated Monte Carlo (MC) dose verification for CyberKnife M6 with Iris collimator and evaluate the dose calculation accuracy of RayTracing (TPS-RT) algorithm and Monte Carlo (TPS-MC) algorithm in the Precision treatment planning system (TPS). METHODS: GPU-accelerated MC algorithm (ArcherQA-CK) was integrated into a commercial dose verification system, ArcherQA, to implement the patient-specific quality assurance in the CyberKnife M6 system. 30 clinical cases (10 cases in head, and 10 cases in chest, and 10 cases in abdomen) were collected in this study. For each case, three different dose calculation methods (TPS-MC, TPS-RT and ArcherQA-CK) were implemented based on the same treatment plan and compared with each other. For evaluation, the 3D global gamma analysis and dose parameters of the target volume and organs at risk (OARs) were analyzed comparatively. RESULTS: For gamma pass rates at the criterion of 2%/2 mm, the results were over 98.0% for TPS-MC vs.TPS-RT, TPS-MC vs. ArcherQA-CK and TPS-RT vs. ArcherQA-CK in head cases, 84.9% for TPS-MC vs.TPS-RT, 98.0% for TPS-MC vs. ArcherQA-CK and 83.3% for TPS-RT vs. ArcherQA-CK in chest cases, 98.2% for TPS-MC vs.TPS-RT, 99.4% for TPS-MC vs. ArcherQA-CK and 94.5% for TPS-RT vs. ArcherQA-CK in abdomen cases. For dose parameters of planning target volume (PTV) in chest cases, the deviations of TPS-RT vs. TPS-MC and ArcherQA-CK vs. TPS-MC had significant difference (P < 0.01), and the deviations of TPS-RT vs. TPS-MC and TPS-RT vs. ArcherQA-CK were similar (P > 0.05). ArcherQA-CK had less calculation time compared with TPS-MC (1.66 min vs. 65.11 min). CONCLUSIONS: Our proposed MC dose engine (ArcherQA-CK) has a high degree of consistency with the Precision TPS-MC algorithm, which can quickly identify the calculation errors of TPS-RT algorithm for some chest cases. ArcherQA-CK can provide accurate patient-specific quality assurance in clinical practice.


Subject(s)
Algorithms , Monte Carlo Method , Organs at Risk , Radiosurgery , Radiotherapy Dosage , Radiotherapy Planning, Computer-Assisted , Humans , Radiosurgery/methods , Radiosurgery/instrumentation , Radiotherapy Planning, Computer-Assisted/methods , Organs at Risk/radiation effects , Neoplasms/surgery , Neoplasms/radiotherapy , Radiotherapy, Intensity-Modulated/methods , Computer Graphics
2.
Radiat Oncol ; 19(1): 87, 2024 Jul 02.
Article in English | MEDLINE | ID: mdl-38956690

ABSTRACT

BACKGROUND AND PURPOSE: Various deep learning auto-segmentation (DLAS) models have been proposed, some of which have been commercialized. However, the issue of performance degradation is notable when pretrained models are deployed in the clinic. This study aims to enhance precision of a popular commercial DLAS product in rectal cancer radiotherapy by localized fine-tuning, addressing challenges in practicality and generalizability in real-world clinical settings. MATERIALS AND METHODS: A total of 120 Stage II/III mid-low rectal cancer patients were retrospectively enrolled and divided into three datasets: training (n = 60), external validation (ExVal, n = 30), and generalizability evaluation (GenEva, n = 30) datasets respectively. The patients in the training and ExVal dataset were acquired on the same CT simulator, while those in GenEva were on a different CT simulator. The commercial DLAS software was first localized fine-tuned (LFT) for clinical target volume (CTV) and organs-at-risk (OAR) using the training data, and then validated on ExVal and GenEva respectively. Performance evaluation involved comparing the LFT model with the vendor-provided pretrained model (VPM) against ground truth contours, using metrics like Dice similarity coefficient (DSC), 95th Hausdorff distance (95HD), sensitivity and specificity. RESULTS: LFT significantly improved CTV delineation accuracy (p < 0.05) with LFT outperforming VPM in target volume, DSC, 95HD and specificity. Both models exhibited adequate accuracy for bladder and femoral heads, and LFT demonstrated significant enhancement in segmenting the more complex small intestine. We did not identify performance degradation when LFT and VPM models were applied in the GenEva dataset. CONCLUSIONS: The necessity and potential benefits of LFT DLAS towards institution-specific model adaption is underscored. The commercial DLAS software exhibits superior accuracy once localized fine-tuned, and is highly robust to imaging equipment changes.


Subject(s)
Deep Learning , Organs at Risk , Radiotherapy Planning, Computer-Assisted , Rectal Neoplasms , Humans , Rectal Neoplasms/radiotherapy , Rectal Neoplasms/pathology , Organs at Risk/radiation effects , Retrospective Studies , Radiotherapy Planning, Computer-Assisted/methods , Female , Male , Middle Aged , Aged , Radiotherapy Dosage , Tomography, X-Ray Computed , Adult , Radiotherapy, Intensity-Modulated/methods
3.
Biomed Phys Eng Express ; 10(4)2024 Jun 26.
Article in English | MEDLINE | ID: mdl-38923907

ABSTRACT

Objective: To summarize our institutional prostate stereotactic body radiation therapy (SBRT) experience using auto beam hold (ABH) technique for intrafractional prostate motion and assess ABH tolerance of 10-millimeter (mm) diameter.Approach: Thirty-two patients (160 fractions) treated using ABH technique between 01/2018 and 03/2021 were analyzed. During treatment, kV images were acquired every 20-degree gantry rotation to visualize 3-4 gold fiducials within prostate to track target motion. If the fiducial center fell outside the tolerance circle (diameter = 10 mm), beam was automatically turned off for reimaging and repositioning. Number of beam holds and couch translational movement magnitudes were recorded. Dosimetric differences from intrafractional motion were calculated by shifting planned isocenter.Main Results: Couch movement magnitude (mean ± SD) in vertical, longitudinal and lateral directions were -0.7 ± 2.5, 1.4 ± 2.9 and -0.1 ± 0.9 mm, respectively. For most fractions (77.5%), no correction was necessary. Number of fractions requiring one, two, or three corrections were 15.6%, 5.6% and 1.3%, respectively. Of the 49 corrections, couch shifts greater than 3 mm were seen primarily in the vertical (31%) and longitudinal (39%) directions; corresponding couch shifts greater than 5 mm occurred in 2% and 6% of cases. Dosimetrically, 100% coverage decreased less than 2% for clinical target volume (CTV) (-1 ± 2%) and less than 10% for PTV (-10 ± 6%). Dose to bladder, bowel and urethra tended to increase (Bladder: ΔD10%:184 ± 466 cGy, ΔD40%:139 ± 241 cGy, Bowel: ΔD1 cm3:54 ± 129 cGy; ΔD5 cm3:44 ± 116 cGy, Urethra: ΔD0.03 cm3:1 ± 1%). Doses to the rectum tended to decrease (Rectum: ΔD1 cm3:-206 ± 564 cGy, ΔD10%:-97 ± 426 cGy; ΔD20%:-50 ± 251 cGy).Significance: With the transition from conventionally fractionated intensity modulated radiation therapy to SBRT for localized prostate cancer treatment, it is imperative to ensure that dose delivery is spatially accurate for appropriate coverage to target volumes and limiting dose to surrounding organs. Intrafractional motion monitoring can be achieved using triggered imaging to image fiducial markers and ABH to allow for reimaging and repositioning for excessive motion.


Subject(s)
Movement , Prostate , Prostatic Neoplasms , Radiometry , Radiosurgery , Radiotherapy Dosage , Radiotherapy Planning, Computer-Assisted , Humans , Male , Prostatic Neoplasms/radiotherapy , Radiosurgery/methods , Prostate/radiation effects , Radiotherapy Planning, Computer-Assisted/methods , Radiometry/methods , Fiducial Markers , Motion , Dose Fractionation, Radiation , Radiotherapy, Intensity-Modulated/methods , Urinary Bladder , Rectum , Organs at Risk/radiation effects
4.
Sheng Wu Yi Xue Gong Cheng Xue Za Zhi ; 41(3): 627-634, 2024 Jun 25.
Article in Chinese | MEDLINE | ID: mdl-38932551

ABSTRACT

The simultaneous objectives of destroying tumor cells while protecting normal pelvic organs present a dual clinical and technical challenge within the realm of pelvic tumor radiotherapy. This article reviews the latest literatures, focusing on technological innovations in key aspects of radiotherapy such as positioning, planning, and delivery. These include positioning fixation techniques, organ-at-risk avoidance irradiation, non-coplanar irradiation techniques, as well as organ displacement protection and image-guided adaptive techniques. It summarizes and discusses the research progress made in the protection of critical organs during pelvic tumor radiotherapy. The paper emphasizes technological advancements in the protection of critical organs throughout the processes of radiotherapy positioning, planning, and implementation, aiming to provide references for further research on the protection of critical organs in the external irradiation treatment of pelvic tumors.


Subject(s)
Organs at Risk , Pelvic Neoplasms , Humans , Pelvic Neoplasms/radiotherapy , Organs at Risk/radiation effects , Radiotherapy Planning, Computer-Assisted/methods , Patient Positioning , Pelvis/radiation effects , Radiotherapy/methods , Radiotherapy/adverse effects , Radiation Protection/methods , Radiation Injuries/prevention & control
5.
Radiat Oncol ; 19(1): 80, 2024 Jun 25.
Article in English | MEDLINE | ID: mdl-38918828

ABSTRACT

INTRODUCTION: Magnetic resonance guided radiotherapy (MRgRT) allows daily adaptation of treatment plans to compensate for positional changes of target volumes and organs at risk (OARs). However, current adaptation times are relatively long and organ movement occurring during the adaptation process might offset the benefit gained by adaptation. The aim of this study was to evaluate the dosimetric impact of these intrafractional changes. Additionally, a method to predict the extent of organ movement before the first treatment was evaluated in order to have the possibility to compensate for them, for example by adding additional margins to OARs. MATERIALS & METHODS: Twenty patients receiving adaptive MRgRT for treatment of abdominal lesions were retrospectively analyzed. Magnetic resonance (MR) images acquired at the start of adaptation and immediately before irradiation were used to calculate adapted and pre-irradiation dose in OARs directly next to the planning target volume. The extent of organ movement was determined on MR images acquired during simulation sessions and adaptive treatments, and their agreement was evaluated. Correlation between the magnitude of organ movement during simulation and the duration of simulation session was analyzed in order to assess whether organ movement might be relevant even if the adaptation process could be accelerated in the future. RESULTS: A significant increase in dose constraint violations was observed from adapted (6.9%) to pre-irradiation (30.2%) dose distributions. Overall, OAR dose increased significantly by 4.3% due to intrafractional organ movement. Median changes in organ position of 7.5 mm (range 1.5-10.5 mm) were detected within a median time of 17.1 min (range 1.6-28.7 min). Good agreement was found between the range of organ movement during simulation and adaptation (66.8%), especially if simulation sessions were longer and multiple MR images were acquired. No correlation was determined between duration of simulation sessions and magnitude of organ movement. CONCLUSION: Intrafractional organ movement can impact dose distributions and lead to violations of OAR tolerance doses, which impairs the benefit of daily on-table plan adaptation. By application of simulation images, the extent of intrafractional organ movement can be predicted, which possibly allows to compensate for them.


Subject(s)
Magnetic Resonance Imaging , Organs at Risk , Radiotherapy Dosage , Radiotherapy Planning, Computer-Assisted , Radiotherapy, Image-Guided , Humans , Radiotherapy, Image-Guided/methods , Radiotherapy Planning, Computer-Assisted/methods , Retrospective Studies , Organs at Risk/radiation effects , Magnetic Resonance Imaging/methods , Abdominal Neoplasms/radiotherapy , Abdominal Neoplasms/diagnostic imaging , Female , Male , Middle Aged , Aged , Radiotherapy, Intensity-Modulated/methods , Movement , Dose Fractionation, Radiation
6.
Acta Oncol ; 63: 448-455, 2024 Jun 20.
Article in English | MEDLINE | ID: mdl-38899392

ABSTRACT

BACKGROUND: Robust optimization has been suggested as an approach to reduce the irradiated volume in lung Stereotactic Body Radiation Therapy (SBRT). We performed a retrospective planning study to investigate the potential benefits over Planning Target Volume (PTV)-based planning. MATERIAL AND METHODS: Thirty-nine patients had additional plans using robust optimization with 5-mm isocenter shifts of the Gross Tumor Volume (GTV) created in addition to the PTV-based plan used for treatment. The optimization included the mid-position phase and the extreme breathing phases of the 4D-CT planning scan. The plans were compared for tumor coverage, isodose volumes, and doses to Organs At Risk (OAR). Additionally, we evaluated both plans with respect to observed tumor motion using the peak tumor motion seen on the planning scan and cone-beam CTs. RESULTS: Statistically significant reductions in irradiated isodose volumes and doses to OAR were achieved with robust optimization, while preserving tumor dose. The reductions were largest for the low-dose volumes and reductions up to 188 ccm was observed. The robust evaluation based on observed peak tumor motion showed comparable target doses between the two planning methods. Accumulated mean GTV-dose was increased by a median of 4.46 Gy and a non-significant increase of 100 Monitor Units (MU) was seen in the robust optimized plans. INTERPRETATION: The robust plans required more time to prepare, and while it might not be a feasible planning strategy for all lung SBRT patients, we suggest it might be useful for selected patients.


Subject(s)
Four-Dimensional Computed Tomography , Lung Neoplasms , Organs at Risk , Radiosurgery , Radiotherapy Dosage , Radiotherapy Planning, Computer-Assisted , Tumor Burden , Humans , Radiosurgery/methods , Lung Neoplasms/radiotherapy , Lung Neoplasms/pathology , Lung Neoplasms/surgery , Lung Neoplasms/diagnostic imaging , Radiotherapy Planning, Computer-Assisted/methods , Retrospective Studies , Organs at Risk/radiation effects , Four-Dimensional Computed Tomography/methods , Cone-Beam Computed Tomography , Male , Photons/therapeutic use , Female , Aged
7.
Acta Oncol ; 63: 477-481, 2024 Jun 20.
Article in English | MEDLINE | ID: mdl-38899395

ABSTRACT

BACKGROUND: Deep learning (DL) models for auto-segmentation in radiotherapy have been extensively studied in retrospective and pilot settings. However, these studies might not reflect the clinical setting. This study compares the use of a clinically implemented in-house trained DL segmentation model for breast cancer to a previously performed pilot study to assess possible differences in performance or acceptability. MATERIAL AND METHODS: Sixty patients with whole breast radiotherapy, with or without an indication for locoregional radiotherapy were included. Structures were qualitatively scored by radiotherapy technologists and radiation oncologists. Quantitative evaluation was performed using dice-similarity coefficient (DSC), 95th percentile of Hausdorff Distance (95%HD) and surface DSC (sDSC), and time needed for generating, checking, and correcting structures was measured. RESULTS: Ninety-three percent of all contours in clinic were scored as clinically acceptable or usable as a starting point, comparable to 92% achieved in the pilot study. Compared to the pilot study, no significant changes in time reduction were achieved for organs at risks (OARs). For target volumes, significantly more time was needed compared to the pilot study for patients including lymph node levels 1-4, although time reduction was still 33% compared to manual segmentation. Almost all contours have better DSC and 95%HD than inter-observer variations. Only CTVn4 scored worse for both metrics, and the thyroid had a higher 95%HD value. INTERPRETATION: The use of the DL model in clinical practice is comparable to the pilot study, showing high acceptability rates and time reduction.


Subject(s)
Breast Neoplasms , Deep Learning , Organs at Risk , Radiotherapy Planning, Computer-Assisted , Humans , Breast Neoplasms/radiotherapy , Breast Neoplasms/pathology , Female , Pilot Projects , Radiotherapy Planning, Computer-Assisted/methods , Organs at Risk/radiation effects , Retrospective Studies , Middle Aged
8.
Radiat Oncol ; 19(1): 75, 2024 Jun 17.
Article in English | MEDLINE | ID: mdl-38886727

ABSTRACT

BACKGROUND AND PURPOSE: Rare but severe toxicities of the optic apparatus have been observed after treatment of intracranial tumours with proton therapy. Some adverse events have occurred at unusually low dose levels and are thus difficult to understand considering dose metrics only. When transitioning from double scattering to pencil beam scanning, little consideration was given to increased dose rates observed with the latter delivery paradigm. We explored if dose rate related metrics could provide additional predicting factors for the development of late visual toxicities. MATERIALS AND METHODS: Radiation-induced intracranial visual pathway lesions were delineated on MRI for all index cases. Voxel-wise maximum dose rate (MDR) was calculated for 2 patients with observed optic nerve toxicities (CTCAE grade 3 and 4), and 6 similar control cases. Additionally, linear energy transfer (LET) related dose enhancing metrics were investigated. RESULTS: For the index cases, which developed toxicities at low dose levels (mean, 50 GyRBE), some dose was delivered at higher instantaneous dose rates. While optic structures of non-toxicity cases were exposed to dose rates of up to 1 to 3.2 GyRBE/s, the pre-chiasmatic optic nerves of the 2 toxicity cases were exposed to dose rates above 3.7 GyRBE/s. LET-related metrics were not substantially different between the index and non-toxicity cases. CONCLUSIONS: Our observations reveal large variations in instantaneous dose rates experienced by different volumes within our patient cohort, even when considering the same indications and beam arrangement. High dose rate regions are spatially overlapping with the radiation induced toxicity areas in the follow up images. At this point, it is not feasible to establish causality between exposure to high dose rates and the development of late optic apparatus toxicities due to the low incidence of injury.


Subject(s)
Brain Neoplasms , Proton Therapy , Radiation Injuries , Radiotherapy Dosage , Humans , Proton Therapy/adverse effects , Proton Therapy/methods , Brain Neoplasms/radiotherapy , Female , Male , Middle Aged , Adult , Radiation Injuries/etiology , Aged , Optic Nerve/radiation effects , Organs at Risk/radiation effects , Radiotherapy Planning, Computer-Assisted/methods , Dose-Response Relationship, Radiation
9.
Technol Cancer Res Treat ; 23: 15330338241259633, 2024.
Article in English | MEDLINE | ID: mdl-38887092

ABSTRACT

PURPOSE: We report a dosimetric study in whole breast irradiation (WBI) of plan robustness evaluation against position error with two radiation techniques: tangential intensity-modulated radiotherapy (T-IMRT) and multi-angle IMRT (M-IMRT). METHODS: Ten left-sided patients underwent WBI were selected. The dosimetric characteristics, biological evaluation and plan robustness were evaluated. The plan robustness quantification was performed by calculating the dose differences (Δ) of the original plan and perturbed plans, which were recalculated by introducing a 3-, 5-, and 10-mm shift in 18 directions. RESULTS: M-IMRT showed better sparing of high-dose volume of organs at risk (OARs), but performed a larger low-dose irradiation volume of normal tissue. The greater shift worsened plan robustness. For a 10-mm perturbation, greater dose differences were observed in T-IMRT plans in nearly all directions, with higher ΔD98%, ΔD95%, and ΔDmean of CTV Boost and CTV. A 10-mm shift in inferior (I) direction induced CTV Boost in T-IMRT plans a 1.1 (ΔD98%), 1.1 (ΔD95%), and 1.7 (ΔDmean) times dose differences greater than dose differences in M-IMRT plans. For CTV Boost, shifts in the right (R) and I directions generated greater dose differences in T-IMRT plans, while shifts in left (L) and superior (S) directions generated larger dose differences in M-IMRT plans. For CTV, T-IMRT plans showed higher sensitivity to a shift in the R direction. M-IMRT plans showed higher sensitivity to shifts in L, S, and I directions. For OARs, negligible dose differences were found in V20 of the lungs and heart. Greater ΔDmax of the left anterior descending artery (LAD) was seen in M-IMRT plans. CONCLUSION: We proposed a plan robustness evaluation method to determine the beam angle against position uncertainty accompanied by optimal dose distribution and OAR sparing.


Subject(s)
Organs at Risk , Radiotherapy Dosage , Radiotherapy Planning, Computer-Assisted , Radiotherapy, Intensity-Modulated , Unilateral Breast Neoplasms , Humans , Radiotherapy, Intensity-Modulated/methods , Radiotherapy Planning, Computer-Assisted/methods , Female , Organs at Risk/radiation effects , Unilateral Breast Neoplasms/radiotherapy , Breast Neoplasms/radiotherapy , Radiometry/methods , Middle Aged
10.
Radiat Prot Dosimetry ; 200(9): 842-847, 2024 Jun 18.
Article in English | MEDLINE | ID: mdl-38828501

ABSTRACT

Imaging parameters, frequencies and resulting patient organ doses in treatments of prostate cancer were assessed in Finnish radiotherapy centres. Based on a questionnaire to the clinics, Monte Carlo method was used to estimate organ doses in International Commission on Radiological Protection standard phantom for prostate, bladder, rectum and femoral head. The results show that doses from cone beam computed tomography imaging have reduced compared to earlier studies and are between 3.6 and 34.5 mGy per image for the above-mentioned organs and for normal sized patients. There still is room for further optimization of the patient exposure, as many centres use the default imaging parameters, and the length of the imaged region may not be optimal for the purpose.


Subject(s)
Cone-Beam Computed Tomography , Monte Carlo Method , Patient Positioning , Prostatic Neoplasms , Radiotherapy Dosage , Humans , Male , Cone-Beam Computed Tomography/methods , Prostatic Neoplasms/radiotherapy , Prostatic Neoplasms/diagnostic imaging , Finland , Radiation Dosage , Phantoms, Imaging , Radiotherapy Planning, Computer-Assisted/methods , Organs at Risk/radiation effects , Rectum/radiation effects , Urinary Bladder/radiation effects , Urinary Bladder/diagnostic imaging , Femur Head/radiation effects , Prostate/radiation effects , Prostate/diagnostic imaging
11.
Sci Rep ; 14(1): 14347, 2024 06 21.
Article in English | MEDLINE | ID: mdl-38907042

ABSTRACT

In breast cancer radiation therapy, minimizing radiation-related risks and toxicity is vital for improving life expectancy. Tailoring radiotherapy techniques and treatment positions can reduce radiation doses to normal organs and mitigate treatment-related toxicity. This study entailed a dosimetric comparison of six different external beam whole-breast irradiation techniques in both supine and prone positions. We selected fourteen breast cancer patients, generating six treatment plans in both positions per patient. We assessed target coverage and organs at risk (OAR) doses to evaluate the impact of treatment techniques and positions. Excess absolute risk was calculated to estimate potential secondary cancer risk in the contralateral breast, ipsilateral lung, and contralateral lung. Additionally, we analyzed the distance between the target volume and OARs (heart and ipsilateral lung) while considering the treatment position. The results indicate that prone positioning lowers lung exposure in X-ray radiotherapy. However, particle beam therapies (PBTs) significantly reduce the dose to the heart and ipsilateral lung regardless of the patient's position. Notably, negligible differences were observed between arc-delivery and static-delivery PBTs in terms of target conformity and OAR sparing. This study provides critical dosimetric evidence to facilitate informed decision-making regarding treatment techniques and positions.


Subject(s)
Breast Neoplasms , Organs at Risk , Radiotherapy Dosage , Humans , Female , Breast Neoplasms/radiotherapy , Prone Position , Supine Position , Organs at Risk/radiation effects , Radiotherapy Planning, Computer-Assisted/methods , Radiometry/methods , Patient Positioning/methods , Lung/radiation effects , Middle Aged , Radiotherapy, Intensity-Modulated/methods , Radiotherapy, Intensity-Modulated/adverse effects , Heart/radiation effects
12.
J Egypt Natl Canc Inst ; 36(1): 22, 2024 Jun 24.
Article in English | MEDLINE | ID: mdl-38910202

ABSTRACT

BACKGROUND: Innovations in cancer treatment have contributed to the improved survival rate of cancer patients. The cancer survival rates have been growing and nearly two third of those survivors have been exposed to clinical radiation during their treatment. The study of long-term radiation effects, especially secondary cancer induction, has become increasingly important. An accurate assessment of out-of-field/peripheral dose (PDs) is necessary to estimate the risk of second cancer after radiotherapy and the damage to the organs at risk surrounding the planning target volume. This study was designed to measure the PDs as a function of dose, distances, and depths from Telecobalt-60 (Co-60) beam in water phantom using thermoluminescent dosimeter-100 (TLD-100). METHODS: The PDs were measured for Co-60 beam at specified depths of 0 cm (surface), 5 cm, 10 cm, and 15 cm outside the radiation beam at distances of 5, 10, and 13 cm away from the radiation field edge using TLD-100 (G1 cards) as detectors. These calibrated cards were placed on the acrylic disc in circular tracks. The radiation dose of 2000 mGy of Co-60 beam was applied inside 10 × 10 cm2 field size at constant source to surface distance (SSD) of 80 cm. RESULTS: The results showed maximum and minimum PDs at surface and 5 cm depth respectively at all distances from the radiation field edge. Dose distributions out of the field edge with respect to distance were isotropic. The decrease in PDs at 5 cm depth was due to dominant forward scattering of Co-60 gamma rays. The increase in PDs beyond 5 cm depth was due to increase in the irradiated volume, increase in penumbra, increase in source to axis distance (SAD), and increase in field size due to inverse square factor. CONCLUSION: It is concluded that the PDs depends upon depth and distance from the radiation field edge. All the measurements show PDs in the homogenous medium (water); therefore, it estimates absorbed dose to the organ at risk (OAR) adjacent to cancer tissues/planning target volume (PTV). It is suggested that PDs can be minimized by using the SAD technique, as this technique controls sources of scattered radiation like inverse square factor and effect of penumbra up-to some extent.


Subject(s)
Cobalt Radioisotopes , Phantoms, Imaging , Radiotherapy Dosage , Thermoluminescent Dosimetry , Humans , Thermoluminescent Dosimetry/methods , Water , Radiotherapy Planning, Computer-Assisted/methods , Neoplasms/radiotherapy , Radiation Dosage , Organs at Risk/radiation effects
13.
Technol Cancer Res Treat ; 23: 15330338241252622, 2024.
Article in English | MEDLINE | ID: mdl-38845139

ABSTRACT

Purpose: The aim of this matched-pair cohort study was to evaluate the potential of intensity-modulated proton therapy (IMPT) for sparring of the pelvic bone marrow and thus reduction of hematotoxicity compared to intensity-modulated photon radiotherapy (IMRT) in the setting of postoperative irradiation of gynaecological malignancies. Secondary endpoint was the assessment of predictive parameters for the occurrence of sacral insufficiency fractures (SIF) when applying IMPT. Materials and Methods: Two cohorts were analyzed consisting of 25 patients each. Patients were treated with IMPT compared with IMRT and had uterine cervical (n = 8) or endometrial cancer (n = 17). Dose prescription, patient age, and diagnosis were matched. Dosimetric parameters delivered to the whole pelvic skeleton and subsites (ilium, lumbosacral, sacral, and lower pelvis) and hematological toxicity were evaluated. MRI follow-up for evaluation of SIF was only available for the IMPT group. Results: In the IMPT group, integral dose to the pelvic skeleton was significantly lower (23.4GyRBE vs 34.3Gy; p < 0.001), the average V5Gy, V10Gy, and V20Gy were reduced by 40%, 41%, and 28%, respectively, compared to the IMRT group (p < 0.001). In particular, for subsites ilium and lower pelvis, the low dose volume was significantly lower. Hematotoxicity was significantly more common in the IMRT group (80% vs 32%; p = 0009), especially hematotoxicity ≥ CTCAE II (36% vs 8%; p = 0.037). No patient in the IMPT group experienced hematotoxicity > CTCAE II. In the IMPT cohort, 32% of patients experienced SIF. Overall SIF occurred more frequently with a total dose of 50.4 GyRBE (37.5%) compared to 45 GyRBE (22%). No significant predictive dose parameters regarding SIF could be detected aside from a trend regarding V50Gy to the lumbosacral subsite. Conclusion: Low-dose exposure to the pelvic skeleton and thus hematotoxicity can be significantly reduced by using IMPT compared to a matched photon cohort. Sacral insufficiency fracture rates appear similar to reported rates for IMRT in the literature.


Subject(s)
Bone Marrow , Genital Neoplasms, Female , Proton Therapy , Radiotherapy Dosage , Radiotherapy, Intensity-Modulated , Humans , Female , Radiotherapy, Intensity-Modulated/adverse effects , Radiotherapy, Intensity-Modulated/methods , Proton Therapy/adverse effects , Proton Therapy/methods , Bone Marrow/radiation effects , Bone Marrow/pathology , Middle Aged , Aged , Genital Neoplasms, Female/radiotherapy , Adult , Radiotherapy Planning, Computer-Assisted , Organs at Risk/radiation effects , Organ Sparing Treatments/methods
14.
World J Surg Oncol ; 22(1): 147, 2024 Jun 03.
Article in English | MEDLINE | ID: mdl-38831328

ABSTRACT

BACKGROUND: Radio(chemo)therapy is often required in pelvic malignancies (cancer of the anus, rectum, cervix). Direct irradiation adversely affects ovarian and endometrial function, compromising the fertility of women. While ovarian transposition is an established method to move the ovaries away from the radiation field, surgical procedures to displace the uterus are investigational. This study demonstrates the surgical options for uterine displacement in relation to the radiation dose received.  METHODS: The uterine displacement techniques were carried out sequentially in a human female cadaver to demonstrate each procedure step by step and assess the uterine positions with dosimetric CT scans in a hybrid operating room. Two treatment plans (anal and rectal cancer) were simulated on each of the four dosimetric scans (1. anatomical position, 2. uterine suspension of the round ligaments to the abdominal wall 3. ventrofixation of the uterine fundus at the umbilical level, 4. uterine transposition). Treatments were planned on Eclipse® System (Varian Medical Systems®,USA) using Volumetric Modulated Arc Therapy. Data about maximum (Dmax) and mean (Dmean) radiation dose received and the volume receiving 14 Gy (V14Gy) were collected. RESULTS: All procedures were completed without technical complications. In the rectal cancer simulation with delivery of 50 Gy to the tumor, Dmax, Dmean and V14Gy to the uterus were respectively 52,8 Gy, 34,3 Gy and 30,5cc (1), 31,8 Gy, 20,2 Gy and 22.0cc (2), 24,4 Gy, 6,8 Gy and 5,5cc (3), 1,8 Gy, 0,6 Gy and 0,0cc (4). For anal cancer, delivering 64 Gy to the tumor respectively 46,7 Gy, 34,8 Gy and 31,3cc (1), 34,3 Gy, 20,0 Gy and 21,5cc (2), 21,8 Gy, 5,9 Gy and 2,6cc (3), 1,4 Gy, 0,7 Gy and 0,0cc (4). CONCLUSIONS: The feasibility of several uterine displacement procedures was safely demonstrated. Increasing distance to the radiation field requires more complex surgical interventions to minimize radiation exposure. Surgical strategy needs to be tailored to the multidisciplinary treatment plan, and uterine transposition is the most technically complex with the least dose received.


Subject(s)
Cadaver , Fertility Preservation , Pelvic Neoplasms , Radiotherapy Dosage , Radiotherapy Planning, Computer-Assisted , Radiotherapy, Intensity-Modulated , Uterus , Humans , Female , Radiotherapy Planning, Computer-Assisted/methods , Fertility Preservation/methods , Uterus/radiation effects , Uterus/surgery , Uterus/pathology , Pelvic Neoplasms/radiotherapy , Pelvic Neoplasms/surgery , Pelvic Neoplasms/pathology , Radiotherapy, Intensity-Modulated/methods , Organ Sparing Treatments/methods , Organs at Risk/radiation effects , Prognosis , Radiometry/methods
15.
Technol Cancer Res Treat ; 23: 15330338241260646, 2024.
Article in English | MEDLINE | ID: mdl-38841792

ABSTRACT

OBJECTIVE: The purpose of this research was to compare two treatment techniques for oropharyngeal cancers: conventional linac-based static intensity-modulated radiotherapy (sIMRT) and helical tomotherapy (HT). The study examined several parameters, including target coverage, organs at risk, integral dose, and beam on time. Additionally, the study evaluated the doses to the parotid, temporomandibular joint, and pharyngeal constrictor muscles, which are important for swallowing. METHOD: The present study retrospectively analyzed the data of 13 patients with oropharyngeal cancer who underwent radiotherapy between 2019 and 2021. The treatment plans for each patient were regenerated using both sIMRT and HT treatment planning systems with the sequential boost method. The techniques were evaluated and compared based on dose-volume histogram, homogeneity index, and conformity index parameters. The target coverage and organs at risk were statistically compared for two techniques. Additionally, the doses received by the healthy tissue volume were obtained for integral dose evaluation. The beam on time for each technique was assessed. RESULTS: When considering planning target volume evaluation, there was no difference in Dmeans between the two techniques and sIMRT demonstrated higher D2% values compared to the HT. The HT technique had better results for all organs at risk, such as the parotid, temporomandibular joint, and pharyngeal constrictor muscle. As for integral dose, it has been shown that the sIMRT technique provides better protection compared to HT. In addition, the beam on time was also longer with the HT technique. CONCLUSION: Both techniques may provide optimal target coverage for patients with oropharyngeal cancer. HT conferred notable advantages, especially with regard to critical structures implicated in swallowing, such as the parotid, temporomandibular joint, and pharyngeal constrictor muscle, in comparison to sIMRT.


Subject(s)
Organs at Risk , Oropharyngeal Neoplasms , Parotid Gland , Pharyngeal Muscles , Radiotherapy Dosage , Radiotherapy Planning, Computer-Assisted , Radiotherapy, Intensity-Modulated , Temporomandibular Joint , Humans , Oropharyngeal Neoplasms/radiotherapy , Parotid Gland/radiation effects , Organs at Risk/radiation effects , Radiotherapy Planning, Computer-Assisted/methods , Radiotherapy, Intensity-Modulated/methods , Temporomandibular Joint/radiation effects , Male , Retrospective Studies , Pharyngeal Muscles/radiation effects , Female , Aged , Middle Aged
16.
Cancer Radiother ; 28(3): 282-289, 2024 Jun.
Article in English | MEDLINE | ID: mdl-38906800

ABSTRACT

Orbital radiotherapy for Graves' ophthalmopathy is an example of non-oncological radiotherapy. First introduced in the 1930s, this treatment has become widely used since the 1980s with several studies showing proof of both effectiveness and safety: a decrease of soft tissue involvement in 70 to 80% of patients and an improvement of ocular mobility in 30 to 80% of patients. Nowadays, it's one of the second line treatment options recognized by the European Group on Graves' orbitopathy in the management of a moderate to severe and active disease after failure of glucocorticoids. In that setting, orbital radiotherapy should be combined with glucocorticoids. To our knowledge, there are no practical recommendations on how orbital radiotherapy should be planned and conducted for Graves' ophthalmopathy. Optimal dose is not defined however the most frequent regimen consists of 20Gy in ten fractions of 2Gy, though other options may yield better results. Lastly, the use of modern technique of radiotherapy such as intensity-modulated radiation therapy may allow a better sparing of organs at risk compared to three-dimensional radiotherapy using lateral opposing fields.


Subject(s)
Glucocorticoids , Graves Ophthalmopathy , Humans , Graves Ophthalmopathy/radiotherapy , Glucocorticoids/therapeutic use , Radiotherapy, Intensity-Modulated/methods , Radiotherapy Dosage , Dose Fractionation, Radiation , Organs at Risk/radiation effects
17.
Medicine (Baltimore) ; 103(26): e38529, 2024 Jun 28.
Article in English | MEDLINE | ID: mdl-38941415

ABSTRACT

PURPOSE: The current review aims to summarize the international experience of the impact of adaptive radiotherapy on dosimetry and clinical and toxicity outcomes. Additionally, it might trigger Radiation Oncologists to use ART and evaluate whether ART improves target volume coverage and/or normal tissue sparing and, consequently, therapeutic results. MATERIALS AND METHODS: We conducted an electronic literature search of PubMed/MEDLINE and ScienceDirect from January 2007 to January 2023. The search adhered to the PRISMA guidelines and employed keywords such as ART, HNC, parotid gland, and target volume. Furthermore, we examined the reference lists for studies pertinent to the present review. This study included both retrospective and prospective studies that were considered for inclusion. CONCLUSION: ART replanning appears to be a sustainable strategy to minimize toxicity by improving normal tissue sparing. Furthermore, it can enhance target volume coverage by correctly determining the specific dose to be delivered to the tumor. In conclusion, this review confirmed that ART benefits dosimetric, clinical/therapeutic, and toxicity outcomes.


Subject(s)
Head and Neck Neoplasms , Radiotherapy Dosage , Humans , Head and Neck Neoplasms/radiotherapy , Organs at Risk/radiation effects , Radiotherapy Planning, Computer-Assisted/methods
18.
Radiography (Lond) ; 30(4): 1201-1209, 2024 Jul.
Article in English | MEDLINE | ID: mdl-38905764

ABSTRACT

INTRODUCTION: Evidence suggests the bladder trigone to be a potential organ at risk (OAR) in predicting acute and late genitourinary (GU) side effects when treating prostate cancer with radiotherapy. METHODS: A search of MEDLINE, Cinahl, EMBASE, PubMed, the Cochrane Database of Systematic Reviews and OpenGrey was conducted and no current or underway systematic reviews or scoping reviews on the topic were identified. A systematic literature review was carried out assessing the quality of this evidence. All evidence that prospectively or retrospectively reviewed radiotherapy or modelled radiotherapy dose to the bladder trigone were included. The search was conducted on the 8th July 2021 with 32 studies included in this review. This was repeated 10th June 2023 and two additional studies were identified. Any evidence published since this date have not been included and are a limitation of this review. RESULTS: MRI imaging is recommended to assist in delineating the trigone which has been shown to have a high amount of inter-observer variability and the use of specific training may reduce this. Across all radiotherapy treatment modalities, trigone dose contributed to GU acute and late toxicity symptoms. Trigone motion is relative to prostate motion but further research is required to confirm if the prostate can be used as a reliable surrogate for trigone position. The dose tolerance given for specific trigone related toxicities is debated within the literature, and on analysis the authors of this review suggest bladder trigone dose limits: Dmean < 45.8 Gy, V61.0Gy < 40%, V59.8Gy < 25%, V42.5Gy-V41.0Gy < 91% and V47.4Gy-V43.2Gy < 91% with α/ß of 3 Gy to reduce acute and late GU toxicities. CONCLUSION: There is evidence to support further research into bladder trigone sparing radiotherapy to improve patient outcomes. IMPLICATION FOR PRACTICE: Using the bladder trigone as an organ at risk is possible and the authors are currently seeking funding for a feasibility trial to further investigate this.


Subject(s)
Prostatic Neoplasms , Urinary Bladder , Humans , Male , Prostatic Neoplasms/radiotherapy , Prostatic Neoplasms/diagnostic imaging , Urinary Bladder/radiation effects , Urinary Bladder/diagnostic imaging , Organs at Risk/radiation effects , Radiotherapy Dosage , Magnetic Resonance Imaging , Organ Sparing Treatments/methods , Radiation Injuries/prevention & control
19.
Phys Med Biol ; 69(14)2024 Jul 03.
Article in English | MEDLINE | ID: mdl-38876112

ABSTRACT

Objective. To fabricate and validate a novel focused collimator designed to spare normal tissue in a murine hemithoracic irradiation model using 250 MeV protons delivered at ultra-high dose rates (UHDRs) for preclinical FLASH radiation therapy (FLASH-RT) studies.Approach. A brass collimator was developed to shape 250 MeV UHDR protons from our Varian ProBeam. Six 13 mm apertures, of equivalent size to kV x-ray fields historically used to perform hemithorax irradiations, were precisely machined to match beam divergence, allowing concurrent hemithoracic irradiation of six mice while sparing the contralateral lung and abdominal organs. The collimated field profiles were characterized by film dosimetry, and a radiation survey of neutron activation was performed to ensure the safety of staff positioning animals.Main results. The brass collimator produced 1.2 mm penumbrae radiation fields comparable to kV x-rays used in preclinical studies. The penumbrae in the six apertures are similar, with full-width half-maxima of 13.3 mm and 13.5 mm for the central and peripheral apertures, respectively. The collimator delivered a similar dose at an average rate of 52 Gy s-1for all apertures. While neutron activation produces a high (0.2 mSv h-1) initial ambient equivalent dose rate, a parallel work-flow in which imaging and setup are performed without the collimator ensures safety to staff.Significance. Scanned protons have the greatest potential for future translation of FLASH-RT in clinical treatments due to their ability to treat deep-seated tumors with high conformality. However, the Gaussian distribution of dose in proton spots produces wider lateral penumbrae compared to other modalities. This presents a challenge in small animal pre-clinical studies, where millimeter-scale penumbrae are required to precisely target the intended volume. Offering high-throughput irradiation of mice with sharp penumbrae, our novel collimator-based platform serves as an important benchmark for enabling large-scale, cost-effective radiobiological studies of the FLASH effect in murine models.


Subject(s)
Proton Therapy , Animals , Mice , Proton Therapy/instrumentation , Proton Therapy/methods , Organs at Risk/radiation effects , Radiotherapy Dosage
20.
Radiat Oncol ; 19(1): 69, 2024 May 31.
Article in English | MEDLINE | ID: mdl-38822385

ABSTRACT

BACKGROUND: Multiple artificial intelligence (AI)-based autocontouring solutions have become available, each promising high accuracy and time savings compared with manual contouring. Before implementing AI-driven autocontouring into clinical practice, three commercially available CT-based solutions were evaluated. MATERIALS AND METHODS: The following solutions were evaluated in this work: MIM-ProtégéAI+ (MIM), Radformation-AutoContour (RAD), and Siemens-DirectORGANS (SIE). Sixteen organs were identified that could be contoured by all solutions. For each organ, ten patients that had manually generated contours approved by the treating physician (AP) were identified, totaling forty-seven different patients. CT scans in the supine position were acquired using a Siemens-SOMATOMgo 64-slice helical scanner and used to generate autocontours. Physician scoring of contour accuracy was performed by at least three physicians using a five-point Likert scale. Dice similarity coefficient (DSC), Hausdorff distance (HD) and mean distance to agreement (MDA) were calculated comparing AI contours to "ground truth" AP contours. RESULTS: The average physician score ranged from 1.00, indicating that all physicians reviewed the contour as clinically acceptable with no modifications necessary, to 3.70, indicating changes are required and that the time taken to modify the structures would likely take as long or longer than manually generating the contour. When averaged across all sixteen structures, the AP contours had a physician score of 2.02, MIM 2.07, RAD 1.96 and SIE 1.99. DSC ranged from 0.37 to 0.98, with 41/48 (85.4%) contours having an average DSC ≥ 0.7. Average HD ranged from 2.9 to 43.3 mm. Average MDA ranged from 0.6 to 26.1 mm. CONCLUSIONS: The results of our comparison demonstrate that each vendor's AI contouring solution exhibited capabilities similar to those of manual contouring. There were a small number of cases where unusual anatomy led to poor scores with one or more of the solutions. The consistency and comparable performance of all three vendors' solutions suggest that radiation oncology centers can confidently choose any of the evaluated solutions based on individual preferences, resource availability, and compatibility with their existing clinical workflows. Although AI-based contouring may result in high-quality contours for the majority of patients, a minority of patients require manual contouring and more in-depth physician review.


Subject(s)
Artificial Intelligence , Radiotherapy Planning, Computer-Assisted , Tomography, X-Ray Computed , Humans , Radiotherapy Planning, Computer-Assisted/methods , Organs at Risk/radiation effects , Algorithms , Image Processing, Computer-Assisted/methods
SELECTION OF CITATIONS
SEARCH DETAIL
...