Your browser doesn't support javascript.
loading
: 20 | 50 | 100
1 - 20 de 892
1.
Interv Cardiol Clin ; 13(3): 369-384, 2024 Jul.
Article En | MEDLINE | ID: mdl-38839170

Over the last 2 decades, experience with transcatheter pulmonary valve replacement (TPVR) has grown significantly and has become an effective and reliable way of treating pulmonary valve regurgitation, right ventricular outflow (RVOT) obstruction, and dysfunctional bioprosthetic valves and conduits. With the introduction of self-expanding valves and prestents, dilated native RVOT can be addressed with the transcatheter approach. In this article, the authors review the current practices, technical challenges, and outcomes of TPVR.


Cardiac Catheterization , Heart Defects, Congenital , Heart Valve Prosthesis Implantation , Heart Valve Prosthesis , Pulmonary Valve Insufficiency , Pulmonary Valve , Humans , Cardiac Catheterization/methods , Heart Valve Prosthesis Implantation/methods , Pulmonary Valve/surgery , Heart Defects, Congenital/surgery , Pulmonary Valve Insufficiency/surgery , Pulmonary Valve Insufficiency/diagnosis , Ventricular Outflow Obstruction/surgery , Prosthesis Design , Bioprosthesis
2.
BMC Cardiovasc Disord ; 24(1): 301, 2024 Jun 13.
Article En | MEDLINE | ID: mdl-38872098

BACKGROUND: Studies of transcatheter pulmonary valve replacement (TPVR) with the Melody valve have demonstrated good clinical and hemodynamic outcomes. Our study analyzes the midterm clinical and hemodynamic outcomes for patients who underwent Melody valve implantation in Southeast Asia. METHODS: Patients with circumferential conduits or bioprosthetic valves and experiencing post-operative right ventricular outflow tract (RVOT) dysfunction were recruited for Melody TPVR. RESULTS: Our cohort (n = 14) was evenly divided between pediatric and adult patients. The median age was 19 years (8-38 years), a male-to-female ratio of 6:1 with a median follow-up period of 48 months (16-79 months), and the smallest patient was an 8-year-old boy weighing 18 kg. All TPVR procedures were uneventful and successful with no immediate mortality or conduit rupture. The primary implant indication was combined stenosis and regurgitation. The average conduit diameter was 21 ± 2.3 mm. Concomitant pre-stenting was done in 71.4% of the patients without Melody valve stent fractures (MSFs). Implanted valve size included 22-mm (64.3%), 20-mm (14.3%), and 18-mm (21.4%). After TPVR, the mean gradient across the RVOT was significantly reduced from 41 mmHg (10-48 mmHg) to 16 mmHg (6-35 mmHg) at discharge, p < 0.01. Late follow-up infective endocarditis (IE) was diagnosed in 2 patients (14.3%). Overall freedom from IE was 86% at 79 months follow-up. Three patients (21.4%) developed progressive RVOT gradients. CONCLUSION: For patients in Southeast Asia with RVOT dysfunction, Melody TPVR outcomes are similar to those reported for patients in the US in terms of hemodynamic and clinical improvements. A pre-stenting strategy was adopted and no MSFs were observed. Post-implantation residual stenosis and progressive stenosis of the RVOT require long term monitoring and reintervention. Lastly, IE remained a concern despite vigorous prevention and peri-procedural bacterial endocarditis prophylaxis.


Cardiac Catheterization , Heart Valve Prosthesis Implantation , Heart Valve Prosthesis , Hemodynamics , Prosthesis Design , Pulmonary Valve , Recovery of Function , Humans , Male , Child , Female , Heart Valve Prosthesis Implantation/instrumentation , Heart Valve Prosthesis Implantation/adverse effects , Adolescent , Pulmonary Valve/surgery , Pulmonary Valve/physiopathology , Pulmonary Valve/diagnostic imaging , Treatment Outcome , Young Adult , Cardiac Catheterization/instrumentation , Cardiac Catheterization/adverse effects , Time Factors , Adult , Pulmonary Valve Insufficiency/surgery , Pulmonary Valve Insufficiency/physiopathology , Pulmonary Valve Insufficiency/etiology , Pulmonary Valve Insufficiency/diagnostic imaging , Bioprosthesis , Pulmonary Valve Stenosis/surgery , Pulmonary Valve Stenosis/physiopathology , Pulmonary Valve Stenosis/diagnostic imaging , Retrospective Studies , Risk Factors , Asia, Southeastern
4.
J Am Coll Cardiol ; 83(14): 1310-1321, 2024 Apr 09.
Article En | MEDLINE | ID: mdl-38569760

BACKGROUND: Transcatheter pulmonary valve replacement (TPVR) with the self-expanding Harmony valve (Medtronic) is an emerging treatment for patients with native or surgically repaired right ventricular outflow tract (RVOT) pulmonary regurgitation (PR). Limited data are available since U.S. Food and Drug Administration approval in 2021. OBJECTIVES: In this study, the authors sought to evaluate the safety and short-term effectiveness of self-expanding TPVR in a real-world experience. METHODS: This was a multicenter registry study of consecutive patients with native RVOT PR who underwent TPVR through April 30, 2022, at 11 U.S. CENTERS: The primary outcome was a composite of hemodynamic dysfunction (PR greater than mild and RVOT mean gradient >30 mm Hg) and RVOT reintervention. RESULTS: A total of 243 patients underwent TPVR at a median age of 31 years (Q1-Q3: 19-45 years). Cardiac diagnoses were tetralogy of Fallot (71%), valvular pulmonary stenosis (21%), and other (8%). Acute technical success was achieved in all but 1 case. Procedural serious adverse events occurred in 4% of cases, with no device embolization or death. Hospital length of stay was 1 day in 86% of patients. Ventricular arrhythmia prompting treatment occurred in 19% of cases. At a median follow-up of 13 months (Q1-Q3: 8-19 months), 98% of patients had acceptable hemodynamic function. Estimated freedom from the composite clinical outcome was 99% at 1 year and 96% at 2 years. Freedom from TPVR-related endocarditis was 98% at 1 year. Five patients died from COVID-19 (n = 1), unknown causes (n = 2), and bloodstream infection (n = 2). CONCLUSIONS: In this large multicenter real-world experience, short-term clinical and hemodynamic outcomes of self-expanding TPVR therapy were excellent. Ongoing follow-up of this cohort will provide important insights into long-term outcomes.


Heart Valve Prosthesis Implantation , Heart Valve Prosthesis , Pulmonary Valve Insufficiency , Pulmonary Valve , Humans , Adult , Pulmonary Valve/surgery , Heart Valve Prosthesis Implantation/adverse effects , Cardiac Catheterization/adverse effects , Treatment Outcome , Pulmonary Valve Insufficiency/surgery , Pulmonary Valve Insufficiency/etiology , Registries , Prosthesis Design , Retrospective Studies
6.
Catheter Cardiovasc Interv ; 103(6): 924-933, 2024 May.
Article En | MEDLINE | ID: mdl-38597297

BACKGROUND: Percutaneous pulmonary valve implantation (PPVI) is a non-surgical treatment for right ventricular outflow tract (RVOT) dysfunction. During PPVI, a stented valve, delivered via catheter, replaces the dysfunctional pulmonary valve. Stent oversizing allows valve anchoring within the RVOT, but overexpansion can intrude on the surrounding structures. Potentially dangerous outcomes include aortic valve insufficiency (AVI) from aortic root (AR) distortion and myocardial ischemia from coronary artery (CA) compression. Currently, risks are evaluated via balloon angioplasty/sizing before stent deployment. Patient-specific finite element (FE) analysis frameworks can improve pre-procedural risk assessment, but current methods require hundreds of hours of high-performance computation. METHODS: We created a simplified method to simulate the procedure using patient-specific FE models for accurate, efficient pre-procedural PPVI (using balloon expandable valves) risk assessment. The methodology was tested by retrospectively evaluating the clinical outcome of 12 PPVI candidates. RESULTS: Of 12 patients (median age 14.5 years) with dysfunctional RVOT, 7 had native RVOT and 5 had RV-PA conduits. Seven patients had undergone successful RVOT stent/valve placement, three had significant AVI on balloon testing, one had left CA compression, and one had both AVI and left CA compression. A model-calculated change of more than 20% in lumen diameter of the AR or coronary arteries correctly predicted aortic valve sufficiency and/or CA compression in all the patients. CONCLUSION: Agreement between FE results and clinical outcomes is excellent. Additionally, these models run in 2-6 min on a desktop computer, demonstrating potential use of FE analysis for pre-procedural risk assessment of PPVI in a clinically relevant timeframe.


Cardiac Catheterization , Finite Element Analysis , Heart Valve Prosthesis Implantation , Heart Valve Prosthesis , Models, Cardiovascular , Patient-Specific Modeling , Prosthesis Design , Pulmonary Valve , Humans , Pulmonary Valve/physiopathology , Pulmonary Valve/surgery , Pulmonary Valve/diagnostic imaging , Heart Valve Prosthesis Implantation/instrumentation , Heart Valve Prosthesis Implantation/adverse effects , Risk Assessment , Adolescent , Treatment Outcome , Risk Factors , Male , Child , Retrospective Studies , Female , Cardiac Catheterization/adverse effects , Cardiac Catheterization/instrumentation , Young Adult , Predictive Value of Tests , Hemodynamics , Stents , Pulmonary Valve Insufficiency/physiopathology , Pulmonary Valve Insufficiency/surgery , Pulmonary Valve Insufficiency/diagnostic imaging , Pulmonary Valve Insufficiency/etiology , Ventricular Outflow Obstruction/physiopathology , Ventricular Outflow Obstruction/etiology , Ventricular Outflow Obstruction/diagnostic imaging , Clinical Decision-Making , Adult
7.
Circ Cardiovasc Interv ; 17(5): e013889, 2024 May.
Article En | MEDLINE | ID: mdl-38606564

BACKGROUND: Anatomic selection for Harmony valve implant is determined with the aid of a screening report and perimeter plot (PP) that depicts the perimeter-derived radius along the right ventricular outflow tract (RVOT) and projects device oversizing. The PP provides an estimation of suitability for implant, but its sensitivity as a screening method is unknown. This study was performed to describe anatomic features and outcomes in patients who underwent Harmony TPV25 implant despite a PP that predicted inadequate oversizing. METHODS: We reviewed RVOT anatomic features and measurements in patients who underwent transcatheter pulmonary valve replacement with the Harmony TPV25 device despite a PP that predicted inadequate oversizing. RESULTS: This study included 22 patients. There were no unsuccessful implants or adverse valve-related events. Anatomic features varied, but all patients fit into 1 of 3 anatomic types characterized by differences in RVOT dimensions. Type 1 patients (n=9) had a long RVOT with a choke point and a wide main pulmonary artery. Type 2 patients (n=6) had a short RVOT that was pyramidal in shape, with no choke point, and extensive main pulmonary artery lengthening/expansion during systole. Type 3 patients (n=7) had a short, bulbous main pulmonary artery with a choke point and an open pulmonary artery bifurcation. CONCLUSIONS: Transcatheter pulmonary valve replacement with the Harmony valve is feasible in some patients whose PP fit analysis predicts inadequate oversizing. All cases in this series fit into 1 of 3 anatomic patterns, which are not identified in the screening report. Implanters must review cases individually to assess the feasibility of the implant.


Cardiac Catheterization , Heart Valve Prosthesis Implantation , Heart Valve Prosthesis , Prosthesis Design , Pulmonary Valve , Humans , Pulmonary Valve/surgery , Pulmonary Valve/diagnostic imaging , Pulmonary Valve/physiopathology , Heart Valve Prosthesis Implantation/instrumentation , Heart Valve Prosthesis Implantation/adverse effects , Cardiac Catheterization/instrumentation , Cardiac Catheterization/adverse effects , Treatment Outcome , Male , Female , Adolescent , Young Adult , Child , Adult , Retrospective Studies , Predictive Value of Tests , Pulmonary Valve Insufficiency/surgery , Pulmonary Valve Insufficiency/physiopathology , Pulmonary Valve Insufficiency/diagnostic imaging , Patient Selection , Clinical Decision-Making , Recovery of Function , Hemodynamics
8.
Int J Cardiovasc Imaging ; 40(5): 1135-1147, 2024 May.
Article En | MEDLINE | ID: mdl-38668927

Repaired Tetralogy of Fallot (rTOF) patients suffer from pulmonary regurgitation and may require pulmonary valve replacement (PVR). Cardiac magnetic resonance imaging (cMRI) guides therapy, but conventional measurements do not quantify the intracardiac flow effects from pulmonary regurgitation or PVR. This study investigates intracardiac flow parameters of the right ventricle (RV) of rTOF by computational fluid dynamics (CFD). cMRI of rTOF patients and controls were retrospectively included. Feature-tracking captured RV endocardial contours from long-axis/short-axis cine. Ventricular motion was reconstructed via diffeomorphic mapping, serving as domain boundary for CFD simulations. Vorticity (1/s), viscous energy loss (ELoss, mJ/L) and turbulent kinetic energy (TKE, mJ/L) were quantified in RV outflow tract (RVOT) and RV inflow. These parameters were normalized against total RV kinetic energy (KE) and RV inflow vorticity to derive dimensionless metrics. Vorticity contours by Q-criterion were qualitatively compared. rTOF patients (n = 15) had mean regurgitant fraction 38 ± 12% and RV size 162 ± 35 mL/m2. Compared to controls (n = 12), rTOF had increased RVOT vorticity (142.6 ± 75.6/s vs. 40.4 ± 11.8/s, p < 0.0001), Eloss (55.6 ± 42.5 vs. 5.2 ± 4.4 mJ/L, p = 0.0004), and TKE (5.7 ± 5.9 vs. 0.84 ± 0.46 mJ/L, p = 0.0003). After PVR, there was decrease in normalized RVOT Eloss/TKE (p = 0.0009, p = 0.029) and increase in normalized tricuspid inflow vorticity/KE (p = 0.0136, p = 0.043), corresponding to reorganization of the "donut"-shaped tricuspid ring-vortex. The intracardiac flow in rTOF patients can be simulated to determine the impact of PVR and improve the clinical indications guided by cardiac imaging.


Hemodynamics , Hydrodynamics , Magnetic Resonance Imaging, Cine , Models, Cardiovascular , Predictive Value of Tests , Pulmonary Valve Insufficiency , Tetralogy of Fallot , Ventricular Function, Right , Humans , Tetralogy of Fallot/surgery , Tetralogy of Fallot/physiopathology , Tetralogy of Fallot/diagnostic imaging , Female , Male , Pulmonary Valve Insufficiency/physiopathology , Pulmonary Valve Insufficiency/diagnostic imaging , Pulmonary Valve Insufficiency/surgery , Pulmonary Valve Insufficiency/etiology , Retrospective Studies , Kinetics , Adult , Young Adult , Blood Flow Velocity , Heart Ventricles/physiopathology , Heart Ventricles/diagnostic imaging , Patient-Specific Modeling , Adolescent
9.
Echocardiography ; 41(2): e15765, 2024 Feb.
Article En | MEDLINE | ID: mdl-38341768

BACKGROUND: Mixed pulmonary disease with pulmonary regurgitation (PR) and stenosis (PS) in repaired tetralogy of Fallot (rTOF) can negatively impact ventricular health. Myocardial strain has been shown to be more sensitive at detecting occult ventricular dysfunction compared to right ventricular ejection fraction (RV EF). We hypothesize that rTOF patients with predominant PS will have lower RV global longitudinal strain (RV GLS) prior to and post-transcatheter pulmonary valve replacement (TPVR). METHODS: A retrospective cohort of rTOF patients who underwent cardiac magnetic resonance (CMR) and cardiac catheterization for right ventricular pressure (RVSP) measurement were analyzed at three time points: before valve implantation, at discharge and within 18 months post-TPVR. Patients were dichotomized into three groups based on RVSP: 0%-49%, 50%-74%, and >75%. RV GLS and left ventricular (LV) GLS by speckle tracking echocardiography (STE) were obtained from the apical 4-chamber using TomTec software (TOMTEC IS, Germany). RESULTS: Forty-eight patients were included. Every 14.3% increase in preimplantation RVSP above 28% was associated with an absolute magnitude 1% lower RV GLS (p = .001). Preimplantation RVSP when 75% or higher had 3.36% worse RV GLS than the lowest bin (p = .014). Overall, average RV strain magnitude was higher when preimplantation RVSP was less than 50% and had greater improvement over the three time points. Higher post implantation RVSP correlated with lower strain magnitude. CONCLUSION: Patients with significant PS (>50%) may benefit from earlier PVR and not depend solely on RV size and EF. Myocardial strain may be a more sensitive marker of function; however, larger, prospective studies are needed.


Pulmonary Valve Insufficiency , Pulmonary Valve Stenosis , Pulmonary Valve , Tetralogy of Fallot , Ventricular Dysfunction, Right , Humans , Tetralogy of Fallot/complications , Tetralogy of Fallot/surgery , Global Longitudinal Strain , Pulmonary Valve/diagnostic imaging , Pulmonary Valve/surgery , Stroke Volume , Retrospective Studies , Ventricular Function, Right , Pulmonary Valve Stenosis/complications , Pulmonary Valve Stenosis/surgery , Pulmonary Valve Insufficiency/complications , Pulmonary Valve Insufficiency/diagnostic imaging , Pulmonary Valve Insufficiency/surgery , Ventricular Dysfunction, Right/complications , Ventricular Dysfunction, Right/diagnostic imaging
10.
Catheter Cardiovasc Interv ; 103(4): 612-617, 2024 03.
Article En | MEDLINE | ID: mdl-38419395

While newer self-expanding pulmonic valves were primarily designed for larger right ventricular outflow tracks, there are instances where even larger anatomies cannot accommodate these devices. In this report, we describe the successful implantation of two Harmony™ valves in bilateral branch pulmonary arteries after exhausting other options.


Heart Valve Prosthesis Implantation , Pulmonary Valve Insufficiency , Humans , Heart Valve Prosthesis Implantation/adverse effects , Pulmonary Artery/diagnostic imaging , Pulmonary Valve Insufficiency/diagnostic imaging , Pulmonary Valve Insufficiency/etiology , Pulmonary Valve Insufficiency/surgery , Treatment Outcome , Cardiac Catheterization
11.
J Cardiothorac Surg ; 19(1): 98, 2024 Feb 16.
Article En | MEDLINE | ID: mdl-38365717

BACKGROUND: Recently, improvements in the repair of tetralogy of Fallot have increased the need for reoperation in adulthood, and it's not rare that these reoperation candidates suffer from biventricular failure. However, there are no firm treatment guidelines, and each country, and even each facility, treats each case individually. CASE PRESENTATION: We report the successful staged treatment of pulmonary regurgitation and pacemaker-induced cardiomyopathy with biventricular failure in adulthood in a case of complete atrioventricular block after tetralogy of Fallot repair in childhood. We planned a staged therapeutic strategy with preoperative left ventricular volume reduction with medication, following surgical pulmonary valve replacement concomitant epicardial lead implantation on the lateral basal wall, placed just beneath the generator pocket through 3rd intercostal space. in addition to postoperative intervention with a defibrillator to adjust cardiac resynchronization therapy, resulted in improvement of symptoms. CONCLUSION: In a patient with biventricular failure after TOF repair, a staged treatment strategy involving medication, PVR, and CRT with a combination of epicardial and intravenous leads could be a useful treatment worth trying before heart transplantation.


Cardiomyopathies , Pacemaker, Artificial , Pulmonary Valve Insufficiency , Tetralogy of Fallot , Humans , Cardiomyopathies/etiology , Cardiomyopathies/surgery , Heart Failure/surgery , Pacemaker, Artificial/adverse effects , Pulmonary Valve Insufficiency/surgery , Tetralogy of Fallot/surgery , Treatment Outcome , Adult
12.
Catheter Cardiovasc Interv ; 103(4): 587-596, 2024 03.
Article En | MEDLINE | ID: mdl-38341624

BACKGROUND: Pulsta valve is increasingly used for percutaneous pulmonary valve implantation (PPVI) in patients with a large native right ventricular outflow tract (RVOT). This study aims to elucidate the outcomes of Pulsta valve implantation within the native RVOT and assess its adaptability to various native main pulmonary artery (PA) anatomies. METHODS: A multicenter retrospective study included 182 patients with moderate to severe pulmonary regurgitation in the native RVOT who underwent PPVI with Pulsta valves® between February 2016 and August 2023 at five Korean and Taiwanese tertiary referral centers. RESULTS: Pulsta valve implantation was successful in 179 out of 182 patients (98.4%) with an average age of 26.7 ± 11.0 years. The median follow-up duration was 29 months. Baseline assessments revealed enlarged right ventricle (RV) volume (mean indexed RV end-diastolic volume: 163.1 (interquartile range, IQR: 152.0-180.3 mL/m²), which significantly decreased to 123.6(IQR: 106.6-137.5 mL/m2  after 1 year. The main PA types were classified as pyramidal (3.8%), straight (38.5%), reverse pyramidal (13.2%), convex (26.4%), and concave (18.1%) shapes. Pulsta valve placement was adapted, with distal main PA for pyramidal shapes and proximal or mid-PA for reverse pyramidal shapes. Two patients experienced Pulsta valve embolization to RV, requiring surgical removal, and one patient encountered valve migration to the distal main PA, necessitating surgical fixation. CONCLUSIONS: Customized valve insertion sites are pivotal in self-expandable PPVI considering diverse native RVOT shape. The rather soft and compact structure of the Pulsta valve has characteristics to are adaptable to diverse native RVOT geometries.


Heart Valve Prosthesis Implantation , Heart Valve Prosthesis , Pulmonary Valve Insufficiency , Pulmonary Valve , Humans , Adolescent , Young Adult , Adult , Pulmonary Valve/diagnostic imaging , Pulmonary Valve/surgery , Heart Valve Prosthesis Implantation/adverse effects , Heart Ventricles , Retrospective Studies , Pulmonary Artery/diagnostic imaging , Pulmonary Artery/surgery , Treatment Outcome , Pulmonary Valve Insufficiency/diagnostic imaging , Pulmonary Valve Insufficiency/etiology , Pulmonary Valve Insufficiency/surgery , Cardiac Catheterization
13.
Int J Cardiovasc Imaging ; 40(3): 655-664, 2024 Mar.
Article En | MEDLINE | ID: mdl-38363435

In patients with repaired tetralogy of Fallot (rTOF), the regurgitant fraction (RF) in left pulmonary artery (LPA) and right pulmonary artery (RPA) is usually unequal. The morphometrics may play a crucial role in this RF discrepancy. Cardiovascular MR of 79 rTOF patients and 20 healthy controls were retrospectively enrolled. Forty-four from the 79 patients were matched in age, sex and body surface area to the 20 controls and were investigated for: (1) phase-contrast flow of main pulmonary artery (MPA), LPA, and RPA; (2) vascular angles: the angles between the thoracic anterior-posterior line (TAPL) with MPA (θM-AP), MPA with RPA (θM-R), and MPA with LPA (θM-L); (3) cardiac angle, the angle between TAPL and the interventricular septum; (4) area ratio of bilateral lung and hemithorax regions. Compared with the 20 controls, the 44 rTOF patients exhibited wider θM-AP, sharper θM-L angle, and a smaller θM-L/θM-R ratio. In the 79 rTOF patients, LPA showed lower forward, backward, and net flow, and greater RF as compared with RPA. Multivariate analysis showed that the RF of LPA was negatively associated with the θM-L/θM-R ratio and the age at surgery (R2 = 0.255). Conversely, the RF of RPA was negatively associated with the left lung/left hemithorax area ratio and cross-sectional area (CSA) of LPA, and positively associated with CSA of RPA and MPA (R2 = 0.366). In rTOF patients, the RF of LPA is more severe than that of RPA, which may be related to the vascular morphometrics. Different morphometric parameters are independently associated with the RF of LPA or RPA, which may offer potential insights for surgical strategies.


Pulmonary Valve Insufficiency , Tetralogy of Fallot , Ventricular Septum , Humans , Pulmonary Artery/diagnostic imaging , Pulmonary Artery/surgery , Tetralogy of Fallot/diagnostic imaging , Tetralogy of Fallot/surgery , Retrospective Studies , Pulmonary Valve Insufficiency/diagnostic imaging , Pulmonary Valve Insufficiency/etiology , Pulmonary Valve Insufficiency/surgery , Predictive Value of Tests
14.
Heart Vessels ; 39(6): 556-562, 2024 Jun.
Article En | MEDLINE | ID: mdl-38368576

Cardiac magnetic resonance imaging (CMR) often shows discrepancies between right ventricular outflow tract (RVOT) flow and left ventricular outflow tract flow in patients with late-stage repaired tetralogy of Fallot (rTOF), leading to potential errors in pulmonary regurgitation fraction (PRF) assessment. This study aimed to identify the conditions under which RVOT flow can be acutely evaluated using four-dimensional (4D) flow CMR. Twenty-seven consecutive patients with rTOF underwent both two-dimensional phase-contrast (2D PC) and 4D flow CMR between 2016 and 2018, excluding those with peripheral pulmonary artery stenosis, RVOT conduit replacement, unknown surgical method, and an aortic valve regurgitation greater than 20%. Seven healthy controls also underwent only 4D Flow CMR. All healthy controls and fifteen patients with rTOF showed laminar RVOT flow, while seven patients exhibited helical, and four patients exhibited vortical RVOT flow in 4D flow CMR visualization. Flow-volume concordance between the pulmonary artery and aortic flow was significantly lower in patients with rTOF and PRF > 40% in 2D PC CMR. This concordance rate in the suprapulmonary valve was high in both the TOF and control groups, comparing at five RVOT locations in 4D flow CMR. Regarding RVOT flow regurgitation in 4D flow, the whole bulk evaluation exhibited greater variation depending on the flow type compared to the whole pixel-wise evaluation. The study confirmed the flow volume at the upper section of the pulmonary valve as the most accurate correlate of aortic flow volume. Furthermore, the 4D flow CMR using the pixel-wise method demonstrated superior accuracy compared to the traditional bulk flow method.


Magnetic Resonance Imaging, Cine , Tetralogy of Fallot , Humans , Tetralogy of Fallot/surgery , Tetralogy of Fallot/physiopathology , Male , Female , Adult , Magnetic Resonance Imaging, Cine/methods , Blood Flow Velocity/physiology , Adolescent , Cardiac Surgical Procedures/methods , Young Adult , Heart Ventricles/physiopathology , Heart Ventricles/diagnostic imaging , Ventricular Function, Right/physiology , Retrospective Studies , Pulmonary Valve Insufficiency/physiopathology , Pulmonary Valve Insufficiency/surgery , Pulmonary Valve Insufficiency/etiology , Pulmonary Valve Insufficiency/diagnosis , Pulmonary Valve Insufficiency/diagnostic imaging , Child , Ventricular Outflow Obstruction/physiopathology , Ventricular Outflow Obstruction/etiology , Ventricular Outflow Obstruction/surgery , Ventricular Outflow Obstruction/diagnostic imaging
15.
Catheter Cardiovasc Interv ; 103(3): 455-463, 2024 02.
Article En | MEDLINE | ID: mdl-38204358

This manuscript describes the feasibility and approach to the assessment and performance of transcatheter pulmonary valve replacement (tPVR) in patients with surgically-created "double-barrel" right ventricular outflow tracts (RVOT). Patients with tetralogy of Fallot may have coronary anomalies which prohibit the performance of traditional tetralogy of Fallot repair. In certain cases, this may necessitate the placement of a right ventricle to pulmonary artery conduit in addition to the native RVOT, which is left in situ, creating so-called "double-barrel" RVOTs. When these patients develop RVOT dysfunction later in life, they would typically be referred for reoperation due to concerns for risk of coronary compression associated with a transcatheter approach. However, whether a transcatheter approach with valve replacement in the native RVOT is feasible or safe is unknown. This was a retrospective review of patients with a surgically created "double-barrel" RVOTs who underwent cardiac catheterization for assessment of tPVR at Boston Children's Hospital. From July 2012 to July 2022, there were four patients with "double-barrel" RVOTs who underwent assessment for tPVR. The age at catheterization ranged between 22 and 39 years. In three out of four patients, coronary compression testing was negative. These three patients had successful tPVR in the native RVOT. At follow up, all three patients were free of greater than mild regurgitation by echocardiogram and had a maximum instantaneous gradient across the RVOT ranging between 20 and 33 mmHg. Performance of tPVR in patients with surgically created "double-barrel" RVOTs is feasible. The safety of this procedure depends crucially on coronary artery assessment at all stages.


Heart Valve Prosthesis Implantation , Heart Valve Prosthesis , Pulmonary Valve Insufficiency , Pulmonary Valve , Tetralogy of Fallot , Child , Humans , Young Adult , Adult , Heart Valve Prosthesis Implantation/adverse effects , Heart Valve Prosthesis Implantation/methods , Pulmonary Valve/diagnostic imaging , Pulmonary Valve/surgery , Tetralogy of Fallot/diagnostic imaging , Tetralogy of Fallot/surgery , Heart Ventricles/surgery , Treatment Outcome , Cardiac Catheterization/adverse effects , Cardiac Catheterization/methods , Retrospective Studies , Pulmonary Valve Insufficiency/diagnostic imaging , Pulmonary Valve Insufficiency/etiology , Pulmonary Valve Insufficiency/surgery
16.
J Cardiovasc Magn Reson ; 26(1): 100002, 2024.
Article En | MEDLINE | ID: mdl-38211659

BACKGROUND: Many patients with repaired tetralogy of Fallot require pulmonary valve replacement (PVR) due to significant pulmonary regurgitation (PR). Transcatheter PVR (TPVR) is an equally effective and less invasive alternative to surgical PVR but many native right ventricular outflow tracts (RVOTs) are too large for TPVR at time of referral. Understanding the rate of growth of the RVOT may help optimize timing of referral. This study aims to examine the longitudinal growth of the native RVOT over time in repaired tetralogy of Fallot (TOF). METHODS: A retrospective review of serial cardiac MRI cardiovascular magnetic resonance (CMR) data from 121 patients with repaired TOF and a native RVOT (median age at first CMR 14.7 years, average interval between the first and last CMR of 8.1 years) was performed to measure serial changes in RVOT diameter, cross-sectional area, perimeter-derived diameter, and length. RESULTS: All parameters of RVOT size continued to grow with increasing age but growth was more rapid in the decade after TOF repair (for minimum systolic diameter, mean increase of 5.7 mm per 10 years up to year 12, subsequently 2.3 mm per 10 years). The RVOT was larger with a transannular patch and in patients without pulmonary stenosis (p < 0.001 for both), but this was not associated with rate of growth. More rapid RVOT enlargement was noted in patients with larger right ventricular end-diastolic volume (RVEDV), higher PR fraction, and greater rates of increases in RVEDV and PR (p < 0.001 for all) CONCLUSIONS: in patients with repaired TOF, using serial CMR data, we found that RVOT size increased progressively at all ages, but the rate was more rapid in the first decade after repair. More rapid RVOT enlargement was noted in patients with a larger RV, more PR, and greater rates of increases in RV size and PR severity. These results may be important in considering timing of referral for transcatheter pulmonary valves, in planning transcatheter and surgical valve replacement, and in designing future valves for the native RVOT.


Cardiac Surgical Procedures , Predictive Value of Tests , Pulmonary Valve Insufficiency , Tetralogy of Fallot , Ventricular Function, Right , Humans , Tetralogy of Fallot/surgery , Tetralogy of Fallot/diagnostic imaging , Tetralogy of Fallot/physiopathology , Retrospective Studies , Adolescent , Time Factors , Child , Young Adult , Male , Female , Cardiac Surgical Procedures/adverse effects , Treatment Outcome , Adult , Pulmonary Valve Insufficiency/physiopathology , Pulmonary Valve Insufficiency/diagnostic imaging , Pulmonary Valve Insufficiency/surgery , Pulmonary Valve Insufficiency/etiology , Longitudinal Studies , Child, Preschool , Magnetic Resonance Imaging, Cine , Age Factors , Pulmonary Valve/diagnostic imaging , Pulmonary Valve/surgery , Pulmonary Valve/physiopathology , Infant , Heart Ventricles/diagnostic imaging , Heart Ventricles/physiopathology , Heart Ventricles/surgery , Magnetic Resonance Imaging , Middle Aged
17.
Pediatr Cardiol ; 45(3): 570-579, 2024 Mar.
Article En | MEDLINE | ID: mdl-38296854

Transcatheter pulmonary valve implantation (TPVI) is a surgical alternative for correcting dysfunctional right ventricular outflow tract in previously operated patients. MyVal transcatheter heart valve (THV) (Meril Life Sciences, India), a new transcatheter valve designed for aortic position has recently been reported to be implanted in pulmonary position. Myval transcatheter valve were implanted in patients with stenosed dysfunctional conduits, severe regurgitation from transannular patch or dysfunctional surgical pulmonary valves (Bioprosthesis). Procedural details and post-TPVI follow-up were analysed. Myval TPVI was used in Fifty three patients with median age of 15 years (IQR 12-19.5 years). Almost sixty percent of the patients were male, with a median weight of 50 kg (31-63 kg). Prestenting was used in more than 80 percent of patients (n = 45 patients), while 6 patients had a prior surgical valve implantation. After Myval TPVI implantation, the peak instantaneous gradient across the RVOT decreased from a median of 23.5 mmHg (IQR 10-53 mmHg) pre-procedure to 10 mmHg (IQR 5-16 mmHg) post-procedure. The median fluoroscopy time for the procedure was 35 min (IQR 23.5-44 min). The large sizes-mainly the 29-mm and 32 mm Myval (Navigator, Meril Life Sciences Pvt Ltd, India), were the most used size in 40% (n = 22) of the cases each. The median contrast volume used during the procedure was 247 mL (IQR 120-300 mL). Patients were followed for a median period of 360 days (IQR 164-525 days). At the last clinic follow-up, there was no tricuspid valve regurgitation. Moderate neo-pulmonary valve regurgitation was reported in three cases. Early experience of TPVI with MyVal is encouraging with procedural success in all patients and acceptable mid-term outcomes.


Heart Valve Prosthesis Implantation , Heart Valve Prosthesis , Pulmonary Valve Insufficiency , Pulmonary Valve , Humans , Male , Child , Adolescent , Young Adult , Adult , Female , Pulmonary Valve/surgery , Heart Valve Prosthesis Implantation/methods , Treatment Outcome , Pulmonary Valve Insufficiency/surgery , Pulmonary Valve Insufficiency/etiology , Prosthesis Design , Cardiac Catheterization/methods
18.
BMC Cardiovasc Disord ; 24(1): 15, 2024 01 03.
Article En | MEDLINE | ID: mdl-38172687

BACKGROUND: Patients with repaired Tetralogy of Fallot (rTOF) often develop pulmonary regurgitation (PR) and right ventricle (RV) dysfunction, experiencing increased mortality and morbidity rates in adulthood. Pulmonary valve replacement (PVR) timing to address PR is controversial. Cardiac Magnetic Resonance (CMR) is the gold standard for morpho-functional evaluation of complex cardiopathies. This study aims to identify CMR parameters predictive of adverse outcomes to help defining the best therapeutic management of rTOF patients. METHODS: 130 rTOF patients who underwent CMR (2006-2019) were enrolled in this retrospective single-center study. CMR, clinical, ECG and exercise data were analyzed. Univariate and multivariate analyses identified clinical and CMR parameters predictive of adverse outcomes both individually (e.g., death, arrhythmias, heart failure (HF), pharmacological therapy, QRS ≥ 160ms) and as composite outcome. RESULTS: Univariate analysis confirmed RV volumes and RV ejection fraction corrected for PR as adverse outcome predictors and identified interesting correlations: pulmonary artery bifurcation geometry and abnormal interventricular septum (IVS) motion with arrhythmias (p < .001; p = .037), HF (p = .049; p = .005), composite outcome (p = .039; p = .009); right atrium (RA) dimensions with the composite outcome and the outcomes individually (p < .001). The best predictive models by multivariate analysis included sex (male), RV and RA dilation for QRS ≥ 160ms, time form repair to CMR, age at TOF repair and IVS fibrosis for pharmacological therapy. CONCLUSIONS: Besides RV volumes, new adverse prognostic factors could guide rTOF therapeutic management: pulmonary arteries morphology, abnormal IVS motion, RV dysfunction, RA dilation. Perspective multicentric evaluation is needed to specify their effective role.


Heart Failure , Pulmonary Valve Insufficiency , Tetralogy of Fallot , Ventricular Dysfunction, Right , Humans , Male , Tetralogy of Fallot/diagnostic imaging , Tetralogy of Fallot/surgery , Retrospective Studies , Magnetic Resonance Imaging , Pulmonary Valve Insufficiency/diagnostic imaging , Pulmonary Valve Insufficiency/etiology , Pulmonary Valve Insufficiency/surgery , Magnetic Resonance Spectroscopy , Ventricular Function, Right , Ventricular Dysfunction, Right/diagnostic imaging , Ventricular Dysfunction, Right/etiology
19.
Ann Thorac Surg ; 117(3): 535-541, 2024 Mar.
Article En | MEDLINE | ID: mdl-37666352

BACKGROUND: In 2016 we reported promising midterm outcomes of bicuspid pulmonary valve replacement using 0.1-mm polytetrafluoroethylene (PTFE) membrane. This follow-up study analyzes long-term outcomes and risk factors for reintervention and structural valve deterioration (SVD). METHODS: We performed a retrospective review of the original 119 patients who underwent PTFE bicuspid pulmonary valve replacement. Median patient age was 16.9 years (range, 0.4-57.1). Reintervention was defined as any surgical or percutaneous catheter procedure on the PTFE valve. SVD was defined as development of a peak pressure gradient ≥ 50 mm Hg or at least a moderate amount of pulmonary regurgitation on follow-up echocardiography. RESULTS: The median follow-up duration was 9.5 years. The survival rate was 96.5% at 5 and 10 years, with 2 early and 2 late mortalities. Freedom from reintervention was 90.0% at 5 years and 63.3% at 10 years. Freedom from SVD was 92.8% at 5 years and 51.1% at 10 years, with regurgitation the predominant mode (64.6%). Freedom from both reintervention and SVD at 5 and 10 years were 89.1% and 49.5%, respectively. Multivariable analysis identified smaller valve diameter (hazard ratio, 0.82; P < .001) and more than trivial pulmonary regurgitation at discharge (hazard ratio, 5.81; P < .001) as risk factors for reintervention or SVD. CONCLUSIONS: Long-term results of the PTFE bicuspid pulmonary valve replacement were acceptable. However, improvements may be needed to reduce technical error and improve durability. Smaller valve diameter and more than trivial pulmonary regurgitation at discharge were risk factors for reintervention or SVD, warranting careful follow-up for timely reintervention.


Heart Valve Prosthesis Implantation , Heart Valve Prosthesis , Pulmonary Valve Insufficiency , Pulmonary Valve , Humans , Infant , Child, Preschool , Child , Adolescent , Young Adult , Adult , Middle Aged , Pulmonary Valve/surgery , Follow-Up Studies , Pulmonary Valve Insufficiency/surgery , Polytetrafluoroethylene , Heart Valve Prosthesis Implantation/methods , Retrospective Studies , Treatment Outcome , Aortic Valve/surgery
20.
Catheter Cardiovasc Interv ; 103(2): 359-366, 2024 02.
Article En | MEDLINE | ID: mdl-38054354

BACKGROUND: Percutaneous pulmonary valve implantation (PPVI) with the self-expandable Venus P-valve system is a promising treatment for patients with pulmonary regurgitation (PR) and a native right ventricular outflow tract (RVOT). However, limited data is available regarding its midterm outcomes. This study assessed the midterm clinical and echocardiographic outcomes following Venus P-valve implantation. METHODS: From 2013 to 2018, 55 patients with moderate or severe PR after surgical RVOT repair with a transannular or RVOT patch were consecutively enrolled from six hospitals in China. Five-year clinical and echocardiographic outcomes were collected and evaluated. The primary endpoint was a freedom from all-cause mortality and reintervention. RESULTS: At 5 years, the primary endpoint was met for 96% of patients, corresponding to a freedom from all-cause mortality of 96% (95% confidence interval [CI]: 86%-99%) and freedom from reintervention of 98% (95% CI: 87%-100%). Endocarditis was reported in five patients (four patients within 1 year and one patient at 5 years) following PPVI. Transpulmonary gradient and stent orifice diameter remained stable compared to at discharge (p>0.05). No paravalvular leak was reported while only 1 patient gradually increased to moderate PR during follow-up. Significant improvement of RV diameter and LVEF (p<0.001) sustained over the 5-year follow-up, in consistent with remarked improved New York Heart Association(NYHA) functional class (p<0.001). CONCLUSION: The 5-year results of the China VenusP Study demonstrated the midterm benefits of Venus P-valve implantation in the management of patients with severe PR with an enlarged native RVOT by providing sustained symptomatic and hemodynamic improvement.


Heart Valve Prosthesis Implantation , Heart Valve Prosthesis , Pulmonary Valve Insufficiency , Pulmonary Valve , Ventricular Outflow Obstruction , Humans , Pulmonary Valve Insufficiency/diagnostic imaging , Pulmonary Valve Insufficiency/etiology , Pulmonary Valve Insufficiency/surgery , Pulmonary Valve/diagnostic imaging , Pulmonary Valve/surgery , Heart Valve Prosthesis Implantation/adverse effects , Heart Valve Prosthesis Implantation/methods , Follow-Up Studies , Heart Valve Prosthesis/adverse effects , Treatment Outcome , Prosthesis Design , Cardiac Catheterization/adverse effects , Cardiac Catheterization/methods , Ventricular Outflow Obstruction/diagnostic imaging , Ventricular Outflow Obstruction/etiology , Ventricular Outflow Obstruction/surgery
...