1 - 20 de 2.770
1.
J. optom. (Internet) ; 17(2): [100502], Abr-Jun, 2024. graf
Article En | IBECS | ID: ibc-231625

Background: Silicone oil is used as endotamponade following vitreoretinal surgery to maintain the retina reattached when indicated. This study investigates the hypothesis that silicone oil causes insulation effects on the retina by affecting its response to light. Methods: Electrophysiological responses to a flash stimulus were recorded using full-field electroretinography (ERG) and visual evoked potentials (VEP). Recordings were performed in 9 patients who underwent surgery for retinal detachment, before (1–2 days) and after (2–3 weeks) silicone oil removal (SOR) in both the study and the control eye. Flash ERG and VEP recordings were performed according to the ISCEV standard protocol. Results: Statistically significant differences were found in the study eye in the amplitudes of the ERG responses and their corresponding ratios, i.e. the amplitude after SOR over the amplitude before SOR, in all conditions tested. No differences were observed in the control eye. The mean ratio of photopic ERG response was 3.4 ± 2.4 for the study and 1.0 ± 0.3 for the control eye (p<0.001). The mean ratio of ERG flicker response was 3.1 ± 2.4 and 1.0 ± 0.3, respectively (p = 0.003). Scotopic flash ERG ratio was 5.0 ± 4.4 for the study and 1.3 ± 0.6 for the control eye (p = 0.012). No differences were observed for the amplitude and latency of flash VEP response after SOR. Conclusions: Silicone oil causes a reduction in flash ERG responses; no effect was found on flash VEP responses. ERGs in eyes filled with silicone oil should not be considered representative of retinal functionality, in contrast to VEPs, which are not affected by silicone oil presence.(AU)


Humans , Male , Female , Retinal Detachment/surgery , Silicone Oils/administration & dosage , Silicone Oils/adverse effects , Electroretinography , Vitreoretinal Surgery , Optometry , Vision, Ocular , Retina/surgery , Evoked Potentials, Visual
2.
Farm Hosp ; 48(3): T133-T140, 2024.
Article En, Es | MEDLINE | ID: mdl-38705829

OBJECTIVE: The off-label use in clinical practice of non-approved syringes for intravitreal drug administration has resulted in the detection of silicone oil drops in the vitreous of some patients. This situation derives from the lack of approved syringes for intraocular use in the Spanish market. The aim of this work is to review the use of syringes for intraocular administration, as well as to search for alternatives that meet the legal requirements for these unmet needs. METHOD: A systematic review was performed following the PRISMA 2020 guidelines by searching PubMed with the descriptors: (silicone) AND (syringes) AND ((intraocular) OR (intravitreal)) and filtering all existing publications from January 2006 to December 2023, including all those articles dealing with silicone oil release in intravitreal injections and analysing the possible consequences. RESULTS: Sixty-eight results were found, 23 of which were excluded because they did not deal with the subject under study, leaving a total of 45 articles for the systematic review. These were classified according to the conclusions obtained in 4 groups: the adverse reactions produced by silicone; the administration technique; the physicochemical aspects of silicone release; and the characteristics of the medical device. After reviewing the current manufacturers and technical data sheets of commercialised syringes, the existing syringes for this use have been collected, finding 2 that will probably be commercialised in Spain at the beginning of 2024: Zero Residual™ 0.2 ml SiO-free and VitreJect® Ophthalmic. CONCLUSIONS: From the results obtained, it can be interpreted that the use of syringes and needles with silicone for intravitreal use is a concern for health professionals due to the implications and consequences that may arise in patients, the most important being adverse reactions, so it is necessary to have silicone-free syringes on the market that are specific for intraocular use. Safety and legality in the use of intraocular syringes and needles is essential to guarantee ocular integrity and patient health.


Intravitreal Injections , Silicone Oils , Syringes , Humans , Off-Label Use , Spain
4.
J Indian Soc Pedod Prev Dent ; 42(1): 28-36, 2024 Jan 01.
Article En | MEDLINE | ID: mdl-38616424

BACKGROUND: Chemomechanical debridement is insufficient to disinfect all bacteria from the root canals of primary teeth, and obturation of canals with an appropriate material thus acquires excellent importance and remains a critical step in the ultimate success of pulpectomy. AIM: The aim of the study was to compare and evaluate Endoflas, Metapex, and a mixture of calcium hydroxide (CH) and zinc oxide (ZnO) as obturating materials (OMs) in primary mandibular second molars. MATERIALS AND METHODS: Seventy-five mandibular second primary molars requiring pulpectomies were identified in children aged 4-8 years. They were randomly allocated to the three treatment groups according to the type of OM received using the block randomization technique. After the completion of chemomechanical debridement, the canals were filled with Endoflas, Metapex, and CH-ZnO mixture, respectively. The intergroup clinical and radiographic comparison was made based on Coll and Sadrian criteria to decipher their clinical performance at 1, 3, and 6 months. RESULTS: No statistically significant differences between the groups were observed at any evaluation time interval (P > 0.05). At 6 months, the clinical success rates were 95.2% in Endoflas, 96% in Metapex, and 95.8% in the CH and ZnO mixture groups, respectively. The materials, however, behaved differently in different clinical situations. CONCLUSION: Based on the observations, all three OMs showed similar clinical success in maintaining tooth functioning, but their use can be restricted to indications. However, prospective studies with longer follow-ups with more stringent eligibility criteria are required to reach more definitive conclusions.


Pulpectomy , Silicone Oils , Zinc Oxide , Child , Humans , Prospective Studies , Zinc Oxide/therapeutic use , Calcium Hydroxide/therapeutic use
5.
Int Ophthalmol ; 44(1): 167, 2024 Apr 02.
Article En | MEDLINE | ID: mdl-38565753

PURPOSE: To detect and analyze the influence of the duration of tamponade with silicone oil on the foveal and parafoveal thickness in cases of rhegmatogenous retinal detachment. METHODS: This is a retrospective cohort study of 64 eyes with rhegmatogenous retinal detachment in one eye who underwent pars plana vitrectomy (PPV) with silicone oil injection during the period between January 2019 and December 2021. The patients were divided into 2 groups. Group A with early removal of the silicone oil after 3-4 months and Group B with late removal of the silicone oil (SOR) after 6-8 months. The 2 groups were compared as regards the central foveal (CFT) and parafoveal (PFT) thickness changes from baseline, just before SOR, and after SOR. Changes in best corrected visual acuity (BCVA), relative risk of severe thinning. It was conducted at Kasr Alainy Hospital. RESULTS: 64 eyes were enrolled in the study. Group A included 36 eyes, and group B included 28 eyes. The mean CFT changed insignificantly from 253 ± 52 µm to 252 ± 48 µm after SOR in group A; while it changed significantly from 211 ± 52 µm to 202 ± 46 µm after SOR in group B. The mean PFT decreased insignificantly from 299 ± 39 µm to 297 ± 40 µm in group A, while it decreased significantly from 284 ± 46 µm to 273 ± 44 µm in group B. Lines of improvement of BCVA were 4.11 ± 1.88 in group A, and 2.00 ± 1.24 in group B. Relative risk of severe foveal thinning after SOR was 14.3, and severe parafoveal thinning was 15.43, in group B compared to group A. CONCLUSION: Longer period of silicone oil tamponade may carry a higher risk for severe foveal and parafoveal thinning after silicone oil removal. TRIAL REGISTRATION: The study was registered at clinical trial.gov under the title of (Duration of silicone oil tamponade on foveal and parafoveal thickness in Rhegmatogenous Retinal Detachment) with an ID NCT05817630 at April 2023 "retrospectively registered".


Retinal Detachment , Humans , Retinal Detachment/diagnosis , Retinal Detachment/surgery , Silicone Oils/pharmacology , Retrospective Studies , Visual Acuity , Fovea Centralis , Vitrectomy
6.
BMC Ophthalmol ; 24(1): 184, 2024 Apr 22.
Article En | MEDLINE | ID: mdl-38649837

BACKGROUND: To compare the outcome of eyes with a macula-on giant retinal tear (GRT) detachment treated with pars-plana-vitrectomy (PPV) depending on the used endotamponade. METHODS: All consecutive cases with a macula-on GRT-associated rhegmatogenous retinal detachment (RRD) managed with PPV between 2007 and 2022 were retrospectively assessed depending on the selected endotamponade. By reviewing medical charts and surgical protocols the pre- and intraoperative parameters were analysed in detail. The number of vitreoretinal (VR) procedures needed for reattachment, the redetachment rate and the functional outcome were evaluated. Eyes treated with primary silicone oil (SO) tamponade were compared to eyes with primary gas tamponade. Cases with pre-existing conditions affecting outcome e.g. macula-off situation, history of trauma, status after complicated cataract surgery, former VR surgery or proliferative vitreoretinopathy grade C or higher were excluded. RESULTS: Overall, 51 eyes of 45 patients with a macula-on GRT detachment were treated with PPV and SO (n = 32; 63%) or gas (n = 19; 37%) endotamponade in the observed period. Eyes with primary SO tamponade underwent on average 2.3 (SD 0.8) VR procedures and had a redetachment rate of 13% (n = 4). Eyes with gas tamponade showed a higher redetachment rate of 32% (n = 6) with a mean number of 1.6 (SD 1.0) PPV procedures. Postoperative best-corrected visual acuity (BCVA) was significantly better in eyes with primary gas tamponade (mean logMAR BCVA 0.32; SD 0.30) compared to eyes with SO (mean logMAR BCVA 0.60; SD 0.42; p = 0.008). CONCLUSIONS: Surgical management of GRT-associated RRDs is complex. In clinical routine often SO is used as endotamponade. Because of known disadvantages (second procedure necessary for SO removal, unexplained SO-related visual loss, secondary glaucoma, SO emulsification) some VR surgeons prefer a gas tamponade. In our cohort, eyes with a gas compared to SO tamponade showed higher redetachment rates. However, the final postoperative BCVA was significantly better in eyes with gas compared to SO tamponade. TRIAL REGISTRATION: The trial protocol was approved by the local ethics committee on 25th of November 2022 (Ethikkommission der Universität Regensburg, Votum 22-3166-104).


Endotamponade , Retinal Detachment , Retinal Perforations , Silicone Oils , Visual Acuity , Vitrectomy , Humans , Vitrectomy/methods , Silicone Oils/administration & dosage , Male , Retinal Detachment/surgery , Female , Middle Aged , Retrospective Studies , Endotamponade/methods , Visual Acuity/physiology , Aged , Retinal Perforations/surgery , Retinal Perforations/diagnosis , Adult , Macula Lutea , Treatment Outcome
7.
Klin Monbl Augenheilkd ; 241(4): 472-476, 2024 Apr.
Article En | MEDLINE | ID: mdl-38653297

BACKGROUND: Uncomplicated rhegmatogenous retinal detachment (RRD) is mainly treated with vitrectomy and gas tamponade or, alternatively, scleral buckling surgery. However, gas tamponade inflates at high altitudes, causing significant complications. Silicone oil (SO) tamponade volume is unaffected by atmospheric pressure and may be used in patients who live or must undertake travel at high altitudes. PURPOSE: To determine the anatomical and functional outcomes after pars plana vitrectomy (PPV) with SO tamponade in primary uncomplicated RRD. METHODS: Twenty-eight consecutive cases of patients operated between January 2017 and December 2022 in Jules-Gonin University Eye Hospital in Lausanne were included in this retrospective study. All patients had a follow-up of at least 3 months after SO removal. RESULTS: Primary reattachment was achieved in all 28 eyes. Mean follow-up was 17.2 months (range: 3 - 51 months) after SO removal. Mean age at the time of intervention was 60 years (range: 21 - 80 years). Vision was stabilized or improved in 27 eyes (96%). One patient demonstrated a slight visual acuity decrease due to cataract formation at the last follow-up. In all patients, SO was removed 2 to 5 months after primary repair. In 14 of the 21 phakic patients, concomitant cataract surgery was performed. No surgical complications were encountered. Postoperatively, 5 (18%) patients had ocular hypertension, presumably steroid related, that was successfully controlled with topical treatment. CONCLUSION: PPV with SO injection seems to be a safe and efficient surgical approach in the treatment of primary uncomplicated RRD in patients living at high altitudes and was associated with good anatomical and functional outcome in our series. However, the need for a follow-up surgery to remove SO should be weighed in these cases.


Altitude , Retinal Detachment , Silicone Oils , Visual Acuity , Vitrectomy , Humans , Retinal Detachment/surgery , Silicone Oils/administration & dosage , Middle Aged , Male , Female , Adult , Aged , Retrospective Studies , Vitrectomy/methods , Aged, 80 and over , Young Adult , Treatment Outcome , Endotamponade/methods , Follow-Up Studies
8.
Arq Bras Oftalmol ; 87(4): e2022, 2024.
Article En | MEDLINE | ID: mdl-38656020

PURPOSE: To clarify the postoperative incidence of macular edema in patients undergoing surgery to repair rhegmatogenous retinal detachment and identify the associated risk factors. METHODS: In this prospective, observational study, 79 patients who underwent surgery to correct rhegmatogenous retinal detachment using pars plana vitrectomy with silicone oil injection were analyzed. Patients were followed up postoperatively at 7, 30, 90, 180, and 365 days. At each visit, optical coherence tomography was performed to assess the presence or absence of macular edema. were analyzed as possible risk factors for macular edema: age, sex, macular status (attached or detached), presence of vitreoretinal proliferation, history of previous intraocular surgery, reported time of symptoms suggestive of rhegmatogenous retinal detachment up to the date of surgery, and the surgical modality performed. RESULTS: The 1-year macular edema prevalence rate was 26.6%. In the adjusted analysis, older patients had a higher risk of macular edema, and each 1-year increase in age increased the risk of macular edema by 6% (95% confidence interval = 1.00-1.12). The macular status, vitreoretinal proliferation, the surgical technique used, prior intraocular surgery, and the intraocular lens status were not identified as risk factors. However, the incidence of macular edema increased up to 180 days after surgery, peaking at 10.6%, and then decreased until 365 days after surgery. CONCLUSION: Macular edema was a common complication after surgery to treat rhegmatogenous retinal detachment, with its incidence peaking between 30 and 180 days after surgery. Age was an important risk factor for macular edema in this cohort.


Macular Edema , Retinal Detachment , Tomography, Optical Coherence , Vitrectomy , Humans , Retinal Detachment/surgery , Retinal Detachment/etiology , Male , Female , Macular Edema/etiology , Macular Edema/epidemiology , Middle Aged , Risk Factors , Prospective Studies , Vitrectomy/adverse effects , Vitrectomy/methods , Incidence , Adult , Follow-Up Studies , Tomography, Optical Coherence/methods , Aged , Postoperative Complications/epidemiology , Postoperative Complications/etiology , Visual Acuity , Silicone Oils/adverse effects , Silicone Oils/administration & dosage , Time Factors , Age Factors , Young Adult
9.
Indian J Ophthalmol ; 72(5): 765, 2024 May 01.
Article En | MEDLINE | ID: mdl-38661275

BACKGROUND: A 7-year-old male child was brought by his parents with a complaint of low vision in both eyes for 2 months. The child had low vision in both the eyes for 1.5 years, but the parents noticed when it worsened further 2 months back, leading to profound vision loss. On ophthalmic evaluation, the child did not perceive light in the right eye. Furthermore, anterior segment examination showed complicated cataract and open funnel retinal detachment with intra-retinal cysts in ultrasound (USG) B scan. In the left eye, he could appreciate light but with poor fixation. Fundus evaluation of the left eye showed total retinal detachment on indirect ophthalmoscopy, which was confirmed on USG B scan. Since the right eye had poor visual potential, no intervention was done. The left eye underwent pars plana vitrectomy with silicone oil tamponade, which led to successful anatomical outcomes. The immediate and late postoperative periods were uneventful, and the child was kept under follow-up and was observed closely. PURPOSE: To educate regarding the surgical management of giant retinal tears in a pediatric patient. SYNOPSIS: To inform regarding the surgical challenges faced and steps adopted to manage such cases. HIGHLIGHTS: Through this case, we want to highlight the challenges faced, such as delayed presentation, difficult preoperative evaluation, intraoperative difficulties such as mobile retina, absence of posterior vitreous detachment, and tenacious vitreous gel. We also want to emphasize on the steps taken to overcome the challenges. CONCLUSION: In such challenging situations, effective planning, careful manipulation, and persistence are essential for success. VIDEO LINK: https://youtu.be/T0Gy6Wj13zI.


Endotamponade , Ophthalmoscopy , Retinal Detachment , Retinal Perforations , Visual Acuity , Vitrectomy , Humans , Male , Retinal Detachment/surgery , Retinal Detachment/diagnosis , Retinal Detachment/etiology , Child , Vitrectomy/methods , Retinal Perforations/surgery , Retinal Perforations/diagnosis , Retinal Perforations/etiology , Visual Acuity/physiology , Endotamponade/methods , Silicone Oils/administration & dosage , Tomography, Optical Coherence/methods , Retina/surgery
10.
Biofouling ; 40(2): 209-222, 2024 Feb.
Article En | MEDLINE | ID: mdl-38500010

This study explores the potential of geranium essential oil as a natural solution for combating marine biofouling, addressing the environmental concerns associated with commercial antifouling coatings. Compounds with bactericidal activities were identified by 13Carbon nuclear magnetic resonance (13C NMR). Thermogravimetric analysis (TGA) revealed minimal impact on film thermal stability, maintaining suitability for antifouling applications. The addition of essential oil induced changes in the morphology of the film and Fourier transform infrared spectroscopy (FTIR) analysis indicated that oil remained within the film. Optical microscopy showed an increase in coating porosity after immersion in a marine environment. A total of 18 bacterial colonies were isolated, with Psychrobacter adeliensis and Shewanella algidipiscicola being the predominant biofilm-forming species. The geranium essential oil-based coating demonstrated the ability to reduce the formation of Psychrobacter adeliensis biofilms and effectively inhibit macrofouling adhesion for a duration of 11 months.


Biofouling , Geranium , Oils, Volatile , Psychrobacter , Biofilms , Biofouling/prevention & control , Oils, Volatile/pharmacology , Silicone Oils/pharmacology , Silicones
11.
J Biomater Sci Polym Ed ; 35(9): 1359-1378, 2024 Jun.
Article En | MEDLINE | ID: mdl-38490948

Indwelling medical catheters are frequently utilized in medical procedures, but they are highly susceptible to infection, posing a vital challenge for both health workers and patients. In this study, the superhydrophobic micro-nanostructure surface was constructed on the surface of thermoplastic polyurethane (TPU) membrane using heavy calcium carbonate (CaCO3) template. To decrease the surface free energy, hydroxyl silicone oil was grafted onto the surface, forming a super-hydrophobic surface. The water contact angle (WCA) increased from 91.1° to 143 ± 3° when the concentration of heavy calcium CaCO3 was 20% (weight-to-volume (w/v)). However, the increased WCA was unstable and tended to decrease over time. After grafting hydroxyl silicone oil, the WCA rose to 152.05 ± 1.62° and remained consistently high for a period of 30 min. Attenuated total reflection infrared spectroscopy (ATR-FTIR) analysis revealed a chemical crosslinking between silicone oil and the surface of TPU. Furthermore, Scanning electron microscope (SEM) image showed the presence of numerous nanoparticles on the micro surface. Atomic force microscope (AFM) testing indicated a significant improvement in surface roughness. This method of creating a hydrophobic surface demonstrated several advantages, including resistance to cell, bacterial, protein, and platelet adhesion and good biosecurity. Therefore, it holds promising potential for application in the development of TPU-based medical catheters with antibacterial properties.


Hydrophobic and Hydrophilic Interactions , Polyurethanes , Silicone Oils , Surface Properties , Polyurethanes/chemistry , Silicone Oils/chemistry , Calcium Carbonate/chemistry , Animals , Biocompatible Materials/chemistry , Biocompatible Materials/pharmacology , Mice , Water/chemistry , Temperature , Staphylococcus aureus/drug effects , Materials Testing
12.
BMC Ophthalmol ; 24(1): 119, 2024 Mar 14.
Article En | MEDLINE | ID: mdl-38486220

PURPOSE: To analyze structural changes in the macular retinal layers and sub-foveal choroidal thickness (SFCT) in eyes after macula-on rhegmatogenous retinal detachment (RRD) repair by pars plana vitrectomy with either silicone oil (SO) or gas tamponade, and the effect of these changes on visual acuity. PATIENTS AND METHODS: Retrospective study which included 26 eyes in the SO Group and 32 in the Gas Group. Optical coherence tomography (OCT) scans of the affected eyes were obtained before surgery, and 3 months after PPV in the Gas Group, and during silicone oil in situ and 3 months after SO removal, in the SO Group. Qualitative assessment of photoreceptor layer and foveal contour, along with quantitative assessment of macular retinal thickness and SFCT was performed. Postoperative OCT macular microstructural changes were recorded and correlated to corrected distance visual acuity (CDVA). Intraocular pressure (IOP) was measured preoperative and at 3 months post operative. RESULTS: There was a 2-line loss (from 20/28 preoperatively to 20/40 at final follow-up) of CDVA in the SO Group (p=0.051), while there was no statistically significant change in CDVA in the Gas Group (p=0.786). There was no significant correlation between CDVA loss and duration of silicon tamponade (r=-0.031, p=0.893). There was a statistically significant increase in IOP from its baseline to final follow-up of 0.7 mmHg in the SO Group (p=0.023) while there was no statistically significant change in IOP in the Gas Group. During silicone oil tamponade, there was approximately 11% and 5% of retinal and sub-foveal choroidal thinning respectively, which was moderately resolved following silicone oil removal. 20% (5/24) of eyes in the SO Group had qualitative flattening of foveal contour during SO tamponade that resolved after SO removal. CONCLUSION: Thinning of the macula was noticed after macula-on RRD repair with SO tamponade. Such thinning was only partially reversible after the removal of SO.


Macula Lutea , Retinal Detachment , Humans , Retinal Detachment/surgery , Silicone Oils , Vitrectomy/methods , Retrospective Studies
13.
Farm Hosp ; 48(3): 133-140, 2024.
Article En, Es | MEDLINE | ID: mdl-38556370

OBJECTIVE: The off-label use in clinical practice of non-approved syringes for intravitreal drug administration has resulted in the detection of silicone oil drops in the vitreous of some patients. This situation derives from the lack of approved syringes for intraocular use in the Spanish market. The aim of this work is to review the use of syringes for intraocular administration, as well as to search for alternatives that meet the legal requirements for these unmet needs. METHOD: A systematic review was performed following the PRISMA 2020 Guidelines by searching PubMed with the descriptors: "silicone" AND "syringes" AND ("intraocular" OR "intravitreal") and filtering all existing publications from January 2006 to December 2023, including all those articles dealing with silicone oil release in intravitreal injections and analysing the possible consequences. RESULTS: Sixty-eight results were found, 23 of which were excluded because they did not deal with the subject under study, leaving a total of 45 articles for the systematic review. These were classified according to the conclusions obtained in 4 groups: the adverse reactions produced by silicone, the administration technique, the physicochemical aspects of silicone release, and the characteristics of the medical device. After reviewing the current manufacturers and technical data sheets of commercialized syringes, the existing syringes for this use have been collected, finding two that will probably be commercialized in Spain at the beginning of 2024: Zero Residual™ 0.2 ml SiO-free and VitreJect® Ophthalmic. CONCLUSIONS: From the results obtained, it can be interpreted that the use of syringes and needles with silicone for intravitreal use is a concern for health professionals due to the implications and consequences that may arise in patients, the most important being adverse reactions, so it is necessary to have silicone-free syringes on the market that are specific for intraocular use. Safety and legality in the use of intraocular syringes and needles is essential to guarantee ocular integrity and patient health.


Intravitreal Injections , Silicone Oils , Syringes , Humans , Off-Label Use , Spain
14.
Transl Vis Sci Technol ; 13(3): 4, 2024 Mar 01.
Article En | MEDLINE | ID: mdl-38466299

Purpose: The purpose of this study was to search for contaminants in silicone oil tamponades removed from eyes treated for retinal detachment, and to correlate chemical results with some clinical/functional parameters of the considered eyes. Methods: We examined a sequential cohort of eyes grouped according to the tamponade received: (1) Siluron2000 (S2), (2) RS-OIL ECS5000 (S5), and (3) Densiron Xtra (DX). Samples were collected at the beginning of the scheduled removal and analyzed by untargeted headspace gas-chromatography mass spectrometry (HS-GC-MS). Visual acuity and optic coherence tomography assessments were obtained before and after the tamponade removal. Results: Forty-one samples were analyzed: 22 belonging to the DX group, 13 to the S2 group, and 6 to the S5 group. For each group, a mixture of uninjected commercial preparation was analyzed as the reference. Different siloxanes and fluorinated compounds including perfluorodecalin (PFCL) were the most prevalent chemicals, found in 55% to 100% of the intraocular samples of the 3 groups. Some siloxanes were present also in the control matrices, whereas PFCL was only in the extracted tamponades. In the DX group, the concentration of hexamethylcyclotrisiloxane showed an inverse correlation trend with the duration of its permanence inside the eye (P = 0.054). Different alkanes, propanol, and acetaldehyde were identified only in the control matrices. Conclusions: Several contaminants including siloxanes were identified in the intraocular samples and in the control matrices. A time-related ocular uptake of some of these is conceivable. PFCL was also highly present but only in intraocular samples. Translational Relevance: After intraocular permanence silicone oils (SOs) have various unlabeled contaminants with some relevant differences with the commercial formulation chemical profile.


Fluorocarbons , Retinal Detachment , Humans , Retinal Detachment/surgery , Silicone Oils , Siloxanes , Eye
15.
Int Ophthalmol ; 44(1): 107, 2024 Feb 22.
Article En | MEDLINE | ID: mdl-38386180

PURPOSE: The current study utilizes microperimetry and optical coherence tomography angiography (OCTA) to assess the optic nerve head vasculature, retinal microvasculature, and retinal sensitivity before and after silicone oil (SO) removal. METHODS: This prospective observational case series study involved 30 eyes subjected to silicone oil endotamponade. Microperimetry and OCTA were utilized to assess the vascular density (VD) of the macula and optic nerve head, as well as the retinal sensitivity (RS), of the participants preoperatively and 1 month following SO removal. The correlation between the various parameters of OCTA and microperimetry was evaluated. RESULTS: There was a significant improvement in the postoperative best-corrected visual acuity (BCVA) (p-value < 0.001) and the postoperative total RS, which was 6.38 ± 2.34 dB as compared to a mean preoperative total RS of 5.04 ± 2.06 dB (p-value < 0.001) and showing a significant increase in all rings. However, there was no significant difference in the pre and postoperative macular VD. On the other hand, there was a significant increase in the postoperative VD of the whole disk and the peripapillary capillary plexus, p-values < 0.001 and 0.002, respectively. CONCLUSION: The removal of SO resulted in significant improvements in retinal sensitivity, vision, and optic nerve perfusion. However, no significant change was observed in macular VD. CLINICAL TRIALS: gov Identifier: NCT04928196.


Macula Lutea , Retinal Detachment , Humans , Silicone Oils , Retinal Detachment/diagnosis , Retinal Detachment/surgery , Tomography, Optical Coherence , Visual Field Tests , Perfusion , Angiography
18.
J Oleo Sci ; 73(2): 177-186, 2024.
Article En | MEDLINE | ID: mdl-38311408

Moisturization causes physiological changes that improve the barrier function of human skin and mechanical changes, including skin friction characteristics. This study evaluated petrolatum- or silicone oil-treated human skin to determine the effect of moisturizing on the friction dynamics. The friction force on the human skin was measured using a contact probe with a sinusoidal motion. The contact probe was used to rub the skin of the upper arm of 20 subjects. The water content of the stratum corneum, softness, and barrier function of the skin were measured using a corneometer, cutometer, and tewameter, respectively. Both oils reduce the frictional force on the human skin. Simultaneously, silicone oil also reduced the delay time δ, which is the standardized time difference between the frictional force response to contact probe movement. Three typical friction patterns were also discovered, which were significantly changed by the treatment with oil. These changes were attributed to the lubrication effect and elimination of adhesion at the true contact point between the skin and the contact probe.


Silicone Oils , Skin , Humans , Friction , Oils , Epidermis
19.
J Glaucoma ; 33(5): 310-316, 2024 May 01.
Article En | MEDLINE | ID: mdl-38194266

PRCIS: Longer-term studies with a larger sample size are needed to demonstrate the superiority or equivalence of these procedures. OBJECTIVE: To evaluate the outcomes of the PAUL glaucoma implant (PGI) and Ahmed glaucoma valve (AGV) in patients with secondary glaucoma caused due to silicone oil emulsification. PATIENTS AND METHODS: A retrospective examination was conducted using the medical records of 36 patients who developed secondary glaucoma due to silicone oil emulsification after vitreoretinal surgery and then underwent PGI and AGV implantation surgery. The main outcome measures in the PGI and AGV groups were intraocular pressure (IOP) and its change, the number of antiglaucoma medications, and postoperative complications during the 12-month follow-up period. IOP of <6 mm Hg is used to define hypotonia. RESULTS: There was no statistically significant difference among the patients who underwent PGI and AGV surgeries in terms of IOP averages, both preoperatively and postoperatively on day 1, week 1, month 1, month 3, month 6, and month 12 ( P > 0.05). Before PGI and AGV implantation, the mean IOP was 40 ± 13 mm Hg and 39.3 ± 10 mm Hg, and the mean number of medications was 3.8 ± 0.4 and 4 ± 0, respectively. At the end of the 12-month follow-up period, the mean IOP was 13.5 ± 2.2 ( P < 0.001) mm Hg and 14.9 ± 4.2 ( P < 0.001) mm Hg, whereas the mean number of glaucoma medications decreased to 1.7 ± 1.3 ( P < 0.001) and 1.9 ± 1.8 ( P < 0.001) in the PGI and AGV groups, respectively. Surgical success was achieved in 17 of 18 eyes (94%) in the PGI group and 16 of 18 eyes (89%) in the AGV group. CONCLUSIONS: Although the outcomes were similar in both the PGI and AGV groups, complications requiring medical and surgical intervention were less common in the PGI group. Longer-term studies with a larger sample size are needed to demonstrate the superiority or equivalence of these procedures.


Glaucoma Drainage Implants , Intraocular Pressure , Silicone Oils , Tonometry, Ocular , Visual Acuity , Humans , Intraocular Pressure/physiology , Retrospective Studies , Female , Male , Silicone Oils/administration & dosage , Middle Aged , Visual Acuity/physiology , Adult , Treatment Outcome , Glaucoma/surgery , Glaucoma/physiopathology , Prosthesis Implantation , Follow-Up Studies , Aged , Antihypertensive Agents/administration & dosage , Antihypertensive Agents/therapeutic use , Postoperative Complications , Vitreoretinal Surgery
20.
J Pharm Sci ; 113(5): 1401-1414, 2024 May.
Article En | MEDLINE | ID: mdl-38220088

Silicone oil is a commonly used lubricant in pre-filled syringes (PFSs) and can migrate over time into solution in the form of silicone oil particles (SiOPs). The presence of these SiOPs can result in elevated subvisible particle counts in PFS drug products compared to other drug presentations such as vials or cartridges. Their presence in products presents analytical challenges as they complicate quantitation and characterization of other types of subvisible particles in solution. Previous studies have suggested that they can potentially act as adjuvant resulting in potential safety risks for patients. In this paper we present several analytical case studies describing the impact of the presence of SiOPs in biotherapeutics on the analysis of the drug as well as clinical case studies examining the effect of SiOPs on patient safety. The analytical case studies demonstrate that orthogonal techniques, especially flow imaging, can help differentiate SiOPs from other types of particulate matter. The clinical case studies showed no difference in the observed patient safety profile across multiple drugs, patient populations, and routes of administration, indicating that the presence of SiOPs does not impact patient safety.


Biological Products , Silicone Oils , Humans , Silicone Oils/analysis , Particle Size , Pharmaceutical Preparations , Particulate Matter , Syringes
...