Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 95
Filter
1.
Pediatr Transplant ; 28(5): e14828, 2024 Aug.
Article in English | MEDLINE | ID: mdl-39030991

ABSTRACT

BACKGROUND: Pulmonary vein stenosis (PVS) is a rare condition in which neointimal proliferation leads to venous and arterial hypertension. Little is known about PVS after heart transplant (HTx) in children. We sought to describe the characteristics and outcomes of children who develop PVS after HTx. METHODS: We performed a retrospective review of patients ≤18 years old who underwent HTx at two HTx centers between April 2012 and October 2023. Patients with PVS were identified via database queries. Cardiac diagnosis, PVS location and extent, and outcomes were recorded. RESULTS: Over 11.5 years, 422 patients underwent HTx across both centers. Nineteen patients with PVS (10 male) were identified, 15 with de novo PVS. Sixteen had underlying congenital heart disease (CHD), two with anomalous pulmonary venous return. PVS was diagnosed at a median of 2 months (range 2 weeks to 14 years) after HTx. At time of initial diagnosis, 13 patients had one-vessel PVS. At final follow-up, 7/19 (37%) had increases in the number of vessels involved. Six patients underwent surgery, and nine patients had stent or balloon angioplasty. Two patients were treated for pulmonary hypertension following PVS diagnosis. Three patients died from right heart failure secondary to PVS. CONCLUSIONS: This is the largest study to describe the characteristics of post-HTx PVS in children. PVS occurs in 4.5% of HTx, and underlying CHD is a strong risk factor. Multiple vessels can be involved and may require catheter-based or surgical intervention. Clinicians must be vigilant in monitoring the development of PVS in this population.


Subject(s)
Heart Transplantation , Postoperative Complications , Stenosis, Pulmonary Vein , Humans , Retrospective Studies , Male , Heart Transplantation/adverse effects , Female , Child , Child, Preschool , Stenosis, Pulmonary Vein/etiology , Infant , Adolescent , Postoperative Complications/etiology , Postoperative Complications/epidemiology , Infant, Newborn , Disease Progression , Heart Defects, Congenital/surgery , Heart Defects, Congenital/complications , Follow-Up Studies
2.
BMC Cardiovasc Disord ; 24(1): 315, 2024 Jun 22.
Article in English | MEDLINE | ID: mdl-38909188

ABSTRACT

INTRODUCTION: Fibrosing mediastinitis (FM) is a rare disease characterized by excessive proliferation of fibrous tissue in the mediastinum and can cause bronchial stenosis, superior vena cava obstruction, pulmonary artery and vein stenosis, etc. CASE PRESENTATION: An aging patient with intermittent chest tightness and shortness of breath was diagnosed with FM associated pulmonary hypertension (FM-PH) by echocardiography and enhanced CT of the chest, and CT pulmonary artery (PA)/ pulmonary vein (PV) imaging revealed PA and PV stenosis. Selective angiography revealed complete occlusion of the right upper PV, and we performed endovascular intervention of the total occluded PV. After failure of the antegrade approach, the angiogram revealed well-developed collaterals of the occluded RSPV-V2b, so we chose to proceed via the retrograde approach. We successfully opened the occluded right upper PV and implanted a stent. CONCLUSIONS: This report may provide new management ideas for the interventional treatment of PV occlusion.


Subject(s)
Pulmonary Veins , Stents , Humans , Treatment Outcome , Pulmonary Veins/diagnostic imaging , Pulmonary Veins/physiopathology , Pulmonary Veins/surgery , Chronic Disease , Pulmonary Veno-Occlusive Disease/therapy , Pulmonary Veno-Occlusive Disease/diagnostic imaging , Pulmonary Veno-Occlusive Disease/physiopathology , Pulmonary Veno-Occlusive Disease/etiology , Stenosis, Pulmonary Vein/diagnostic imaging , Stenosis, Pulmonary Vein/therapy , Stenosis, Pulmonary Vein/physiopathology , Stenosis, Pulmonary Vein/etiology , Mediastinitis/diagnosis , Mediastinitis/therapy , Male , Phlebography , Angioplasty, Balloon/instrumentation , Aged , Hypertension, Pulmonary/physiopathology , Hypertension, Pulmonary/therapy , Hypertension, Pulmonary/etiology , Hypertension, Pulmonary/diagnostic imaging , Fibrosis , Collateral Circulation , Pulmonary Circulation , Female
3.
Article in English | MEDLINE | ID: mdl-38522879

ABSTRACT

Pulmonary vein stenosis (PVS) remains a clinical challenge, with progressive restenosis being common. In the past five years, we have seen an exponential increase in both clinical and scientific publication related to PVS. Central to progress in PVS clinical care is the paradigm shift towards collaborative, multidisciplinary care that utilizes a multimodality approach to treatment. This manuscript will discuss recent conceptual gains in PVS treatment and research while highlighting important outstanding questions and barriers.


Subject(s)
Angioplasty, Balloon , Stenosis, Pulmonary Vein , Humans , Stenosis, Pulmonary Vein/etiology , Stenosis, Pulmonary Vein/therapy , Treatment Outcome , Constriction, Pathologic/etiology
4.
Circ J ; 88(7): 1099-1106, 2024 Jun 25.
Article in English | MEDLINE | ID: mdl-38494711

ABSTRACT

BACKGROUND: Pulmonary vein (PV) stenosis (PVS) is a serious complication of atrial fibrillation (AF) ablation. The objective of this study was to describe interventional treatments for PVS after AF ablation and long-term outcomes in Japanese patients.Methods and Results: This multicenter retrospective observational study enrolled 30 patients (26 [87%] male; median age 55 years) with 56 severe PVS lesions from 43 PV interventional procedures. Twenty-seven (90%) patients had symptomatic PVS and 19 (63%) had a history of a single AF ablation. Of the 56 lesions, 41 (73%) were de novo lesions and 15 (27%) were retreated. Thirty-three (59%) lesions were treated with bare metal stents, 14 (25%) were treated with plain balloons, and 9 (16%) were treated with drug-coated balloons. All lesions were successfully treated without any systemic embolic event. Over a median follow-up of 584 days (interquartile range 265-1,165 days), restenosis rates at 1 and 2 years were 35% and 47%, respectively. Multivariate Cox regression analysis revealed devices <7 mm in diameter (hazard ratio [HR] 2.52; 95% confidence interval [CI] 1.04-6.0; P=0.040) and totally occluded lesions (HR 3.33; 95% CI 1.21-9.15; P=0.020) were independent risk factors for restenosis. CONCLUSIONS: All PVS lesions were successfully enlarged by the PV intervention; however, restenosis developed in approximately half the lesions within 2 years.


Subject(s)
Atrial Fibrillation , Catheter Ablation , Stenosis, Pulmonary Vein , Humans , Atrial Fibrillation/surgery , Male , Middle Aged , Female , Retrospective Studies , Stenosis, Pulmonary Vein/etiology , Stenosis, Pulmonary Vein/surgery , Catheter Ablation/adverse effects , Catheter Ablation/methods , Aged , Pulmonary Veins/surgery , Stents , Follow-Up Studies , Adult
5.
Heart Vessels ; 39(7): 616-625, 2024 Jul.
Article in English | MEDLINE | ID: mdl-38526754

ABSTRACT

Accurate measurement of the pulmonary vein dimension (PVD) is important for determining stenosis and efficacy following pulmonary vein isolation (PVI). Little is known about the quantitative evaluation of the impact of the cardiac cycle on pulmonary vein (PV) morphology before and after PVI. This study aims to investigate variations in the ostial size of the PV during the cardiac cycle before and after PVI and the effect of the cardiac cycle on PV stenosis and reduction rate using cardiac computed tomography (CT). Sixty-eight patients with atrial fibrillation who underwent cardiac CT before and after PVI at our institution between 23 January 2021 and 5 February 2022 were retrospectively analyzed. The maximum and minimum PVD were measured at each segment before and after the PV. Each PV was evaluated according to the PVD reduction rate (ΔPVD), calculated as follows: (1 - post-PVD/pre-PVD) × 100 (%). The average dimension of all PVs at the end-diastolic frame was significantly reduced compared to that at the end-systolic frame before PVI. The average dimensions of the right superior and right inferior PV at the end-diastolic frame were significantly reduced compared with those at the end-systolic frame following PVI. The average reduction rate of dimension-classified stenosis of PVs, except for the left inferior PV at the end-diastolic frame, was significantly reduced compared with that at the end-systolic frame. The cardiac cycle affects PVD assessment, including PV stenosis, after PVI. PVD measurement is recommended to be unified to the end-systolic frame of the cardiac cycle to avoid underestimating PV stenosis before and after PVI, ensuring appropriate management and follow-up.


Subject(s)
Atrial Fibrillation , Catheter Ablation , Pulmonary Veins , Humans , Pulmonary Veins/surgery , Pulmonary Veins/diagnostic imaging , Pulmonary Veins/physiopathology , Male , Atrial Fibrillation/surgery , Atrial Fibrillation/physiopathology , Atrial Fibrillation/diagnosis , Female , Retrospective Studies , Middle Aged , Catheter Ablation/methods , Aged , Stenosis, Pulmonary Vein/physiopathology , Stenosis, Pulmonary Vein/etiology , Stenosis, Pulmonary Vein/diagnosis , Stenosis, Pulmonary Vein/surgery , Treatment Outcome , Follow-Up Studies , Heart Rate/physiology
6.
BMC Cardiovasc Disord ; 24(1): 131, 2024 Feb 29.
Article in English | MEDLINE | ID: mdl-38424483

ABSTRACT

This umbrella review synthesizes data from 17 meta-analyses investigating the comparative outcomes of catheter ablation (CA) and medical treatment (MT) for atrial fibrillation (AF). Outcomes assessed were mortality, risk of hospitalization, AF recurrence, cardiovascular events, pulmonary vein stenosis, major bleeding, and changes in left ventricular ejection fraction (LVEF) and MLHFQ score. The findings indicate that CA significantly reduces overall mortality and cardiovascular hospitalization with high strength of evidence. The risk of AF recurrence was notably lower with CA, with moderate strength of evidence. Two associations reported an increased risk of pulmonary vein stenosis and major bleeding with CA, supported by high strength of evidence. Improved LVEF and a positive change in MLHFQ were also associated with CA. Among patients with AF and heart failure, CA appears superior to MT for reducing mortality, improving LVEF, and reducing cardiovascular rehospitalizations. In nonspecific populations, CA reduced mortality and improved LVEF but had higher complication rates. Our findings suggest that CA might offer significant benefits in managing AF, particularly in patients with heart failure. However, the risk of complications, including pulmonary vein stenosis and major bleeding, is notable. Further research in understudied populations may help refine these conclusions.


Subject(s)
Atrial Fibrillation , Catheter Ablation , Heart Failure , Stenosis, Pulmonary Vein , Humans , Atrial Fibrillation/diagnosis , Atrial Fibrillation/drug therapy , Catheter Ablation/adverse effects , Heart Failure/diagnosis , Heart Failure/therapy , Hemorrhage/chemically induced , Randomized Controlled Trials as Topic , Stenosis, Pulmonary Vein/etiology , Stroke Volume , Treatment Outcome , Ventricular Function, Left , Meta-Analysis as Topic
7.
Europace ; 26(2)2024 Feb 01.
Article in English | MEDLINE | ID: mdl-38305503

ABSTRACT

AIMS: When it occurs, pulmonary vein (PV) stenosis after atrial fibrillation (AF) ablation is associated with significant morbidity. Even mild-to-moderate PV narrowing may have long-term implications. Unlike thermal ablation energies, such as radiofrequency (RF) or cryothermy, pulsed field ablation (PFA) is a non-thermal modality associated with less fibrotic proliferation. Herein, we compared the effects of PFA vs. thermal ablation on PV narrowing after AF ablation. METHODS AND RESULTS: ADVENT was a multi-centre, randomized, single-blind study comparing PFA (pentaspline catheter) with thermal ablation-force-sensing RF or cryoballoon (CB)-to treat drug-refractory paroxysmal AF. Pulmonary vein diameter and aggregate cross-sectional area were obtained by baseline and 3-month imaging. The pre-specified, formally tested, secondary safety endpoint compared a measure of PV narrowing between PFA vs. thermal groups, with superiority defined by posterior probability > 0.975. Among subjects randomized to PFA (n = 305) or thermal ablation (n = 302), 259 PFA and 255 thermal ablation (137 RF and 118 CB) subjects had complete baseline and 3-month PV imaging. No subject had significant (≥70%) PV stenosis. Change in aggregate PV cross-sectional area was less with PFA (-0.9%) than thermal ablation (-12%, posterior probability > 0.999)-primarily driven by the RF sub-cohort (-19.5%) vs. CB sub-cohort (-3.3%). Almost half of all PFA PV diameters did not decrease, but the majority (80%) of RF PVs decreased, regardless of PV anatomic location. CONCLUSION: In this first randomized comparison of PFA vs. thermal ablation, PFA resulted in less PV narrowing-thereby underscoring the qualitatively differential and favourable impact of PFA on PV tissue.


Subject(s)
Atrial Fibrillation , Catheter Ablation , Pulmonary Veins , Stenosis, Pulmonary Vein , Humans , Pulmonary Veins/surgery , Constriction, Pathologic/complications , Constriction, Pathologic/surgery , Single-Blind Method , Treatment Outcome , Atrial Fibrillation/diagnosis , Atrial Fibrillation/surgery , Atrial Fibrillation/complications , Catheter Ablation/adverse effects , Catheter Ablation/methods , Stenosis, Pulmonary Vein/diagnostic imaging , Stenosis, Pulmonary Vein/etiology
11.
Pediatr Cardiol ; 44(8): 1778-1787, 2023 Dec.
Article in English | MEDLINE | ID: mdl-37422845

ABSTRACT

Pulmonary vein stenosis (PVS) in children is a challenging condition with poor outcomes. Post-operative stenosis can occur after repair of anomalous pulmonary venous return (APVR) or stenosis within native veins. There is limited data on the outcomes of post-operative PVS. Our objective was to review our experience and assess surgical and transcatheter outcomes. Single-center retrospective study was performed including patients < 18 years who developed restenosis after baseline pulmonary vein surgery that required additional intervention(s) from 1/2005 to 1/2020. Non-invasive imaging, catheterization and surgical data were reviewed. We identified 46 patients with post-operative PVS with 11 (23.9%) patient deaths. Median age at index procedure was 7.2 months (range 1 month-10 years), and median follow-up was 10.8 months (range 1 day-13 years). Index procedure was surgical in 36 (78.3%) and transcatheter in 10 (21.7%). Twenty-three (50%) patients developed vein atresia. Mortality was not associated with number of affected veins, vein atresia, or procedure type. Single ventricle physiology, complex congenital heart disease (CCHD), and genetic disorders were associated with mortality. Survival rate was higher in APVR patients (p = 0.03). Patients with three or more interventions had a higher survival rate compared to patients with 1-2 interventions (p = 0.02). Male gender, necrotizing enterocolitis, and diffuse hypoplasia were associated with vein atresia. In post-operative PVS, mortality is associated with CCHD, single ventricle physiology, and genetic disorders. Vein atresia is associated with male gender, necrotizing enterocolitis, and diffuse hypoplasia. Multiple repeated interventions may offer a patient survival benefit; however, larger prospective studies are necessary to elucidate this relationship further.


Subject(s)
Enterocolitis, Necrotizing , Pulmonary Veins , Scimitar Syndrome , Stenosis, Pulmonary Vein , Univentricular Heart , Child , Humans , Infant, Newborn , Male , Infant , Stenosis, Pulmonary Vein/etiology , Stenosis, Pulmonary Vein/surgery , Constriction, Pathologic , Retrospective Studies , Prospective Studies , Pulmonary Veins/surgery , Pulmonary Veins/abnormalities , Risk Factors , Scimitar Syndrome/surgery , Treatment Outcome
13.
J Am Coll Cardiol ; 81(24): 2361-2373, 2023 06 20.
Article in English | MEDLINE | ID: mdl-37316116

ABSTRACT

Pulmonary vein stenosis (PVS) can arise from several etiologies, including congenital, acquired, and iatrogenic sources. PVS presents insidiously, leading to significant delays in diagnosis. A high index of suspicion and dedicated noninvasive evaluation are key to diagnosis. Once diagnosed, both noninvasive and invasive evaluation may afford further insights into the relative contribution of PVS to symptoms. Treatment of underlying reversible pathologies coupled with transcatheter balloon angioplasty and stenting for persistent severe stenoses are established approaches. Ongoing refinements in diagnostic modalities, interventional approaches, postintervention monitoring, and medical therapies hold promise to further improve patient outcomes.


Subject(s)
Angioplasty, Balloon , Stenosis, Pulmonary Vein , Humans , Stenosis, Pulmonary Vein/diagnosis , Stenosis, Pulmonary Vein/etiology , Stenosis, Pulmonary Vein/therapy , Constriction, Pathologic/diagnosis , Constriction, Pathologic/etiology , Constriction, Pathologic/therapy , Stents
14.
Circ J ; 87(12): 1711-1719, 2023 11 24.
Article in English | MEDLINE | ID: mdl-37258224

ABSTRACT

BACKGROUND: Pulmonary vein stenosis (PVS) after PV isolation (PVI) for atrial fibrillation (AF) is a severe complication that requires angioplasty. This study aimed to compare the reduction of the cross-sectional PV area (PVA) and the incidence of PVS after cryoballoon (CB)-PVI, hot balloon (HB)-PVI, or laser balloon (LB)-PVI.Methods and Results: A total of 320 patients who underwent an initial catheter ablation procedure for AF using a CB, HB, or LB in 2 hospitals were included. They underwent contrast-enhanced multidetector CT before and 3 months after the procedure. In all 4 PVs, the reduction in PVA was more significant in the LB group than in the CB or HB groups, respectively. Moderate (50-75%) and severe (>75%) PVS were observed in 5.3% and 0.5% of the PVs, respectively. Although moderate PVS was more frequently observed in the LB group than in the CB or HB groups (8.2%, 3.8%, and 5.0%; P=0.03), the incidence of severe PVS was similar in the LB, CB, and HB groups (0.3%, 0.5%, and 1.0%; P=0.46). Symptomatic PVS requiring intervention occurred in 1 (0.3%) patient. CONCLUSIONS: Although the reduction in cross-sectional PVA and the incidence of moderate PVS after LB-PVI was more significant than after CB-PVI or HB-PVI, it rarely led to severe PVS. Symptomatic PVS requiring intervention was rare after the balloon ablation of AF.


Subject(s)
Atrial Fibrillation , Catheter Ablation , Cryosurgery , Pulmonary Veins , Stenosis, Pulmonary Vein , Humans , Stenosis, Pulmonary Vein/diagnostic imaging , Stenosis, Pulmonary Vein/etiology , Cross-Sectional Studies , Pulmonary Veins/diagnostic imaging , Pulmonary Veins/surgery , Cryosurgery/adverse effects , Cryosurgery/methods , Treatment Outcome , Catheter Ablation/adverse effects , Catheter Ablation/methods , Lasers
15.
Circ Arrhythm Electrophysiol ; 16(3): e011780, 2023 03.
Article in English | MEDLINE | ID: mdl-36735937

ABSTRACT

BACKGROUND: The inspIRE study (Study for Treatment of Paroxysmal Atrial Fibrillation [PAF] by Pulsed Field Ablation [PFA] System With Irreversible Electroporation [IRE]) evaluated safety and effectiveness of a fully integrated biphasic pulsed field ablation (PFA) system with a variable-loop circular catheter for the treatment of drug-refractory paroxysmal atrial fibrillation. METHODS: Subjects underwent pulmonary vein (PV) isolation with the PFA system, using at least 12 applications per vein; adenosine/isoproterenol was administered to confirm entrance block. Wave I assessed initial safety, including for esophageal lesions, silent cerebral lesions, and PV stenosis. Wave II (pivotal phase) tested (1) primary safety, incidence of early-onset primary adverse events, and (2) primary effectiveness, confirmed PV isolation with freedom from documented atrial arrhythmia at 12 months. The study design specified an interim analysis to determine early success once 30 subjects reached the 12-month follow-up and all subjects reached 3-month follow-up. RESULTS: Across 13 centers in Europe/Canada, 226 subjects were enrolled, met criteria for safety and effectiveness evaluations, and received PFA (Wave I, 40; Wave II, 186). Wave I demonstrated no esophageal thermal lesions or PV stenosis. Among 39 subjects with cerebral magnetic resonance imaging, silent cerebral lesions were detected in 4 of the first 6 subjects, after which workflow enhancements, including a 10-second pause between PFA applications, were implemented; subsequently, only 4 of 33 subjects had silent cerebral lesions. In the Wave II phase, no primary adverse events were reported. Upon declaring early success, 83 subjects reached 12-month follow-up. With 100% entrance block, PV isolation without acute reconnection was achieved in 97.1% of targeted veins. For Wave II, the primary effectiveness end point per Kaplan-Meier at the time of interim analysis was 70.9%; 12-month freedom from symptomatic atrial fibrillation/atrial flutter/atrial tachycardia recurrence and repeat ablation was 78.9% and 92.3%, respectively. Total procedure and transpired PFA times were 70.1±27.7 and 26.7±14.0 minutes, respectively. CONCLUSIONS: The inspIRE trial confirmed the safety and effectiveness of the novel mapping-integrated PFA system. REGISTRATION: URL: https://www. CLINICALTRIALS: gov; unique identifier: NCT04524364.


Subject(s)
Atrial Fibrillation , Catheter Ablation , Pulmonary Veins , Stenosis, Pulmonary Vein , Humans , Atrial Fibrillation/diagnosis , Atrial Fibrillation/surgery , Atrial Fibrillation/etiology , Constriction, Pathologic/etiology , Constriction, Pathologic/surgery , Treatment Outcome , Catheters , Europe , Pulmonary Veins/surgery , Stenosis, Pulmonary Vein/etiology , Catheter Ablation/adverse effects , Catheter Ablation/methods , Recurrence
16.
Cardiol Young ; 33(3): 490-492, 2023 Mar.
Article in English | MEDLINE | ID: mdl-35791267

ABSTRACT

Transcatheter intervention on the pulmonary vein often requires performing transseptal puncture, which is a risky procedure. We describe a rare association of a partially unroofed coronary sinus with pulmonary vein stenosis causing desaturation in a young infant where the presence of the unroofed coronary sinus allowed for a novel interventional approach to the stenotic left pulmonary vein, avoiding the high risk of transseptal puncture.


Subject(s)
Coronary Sinus , Coronary Vessel Anomalies , Heart Septal Defects, Atrial , Stenosis, Pulmonary Vein , Vascular Malformations , Humans , Infant , Stenosis, Pulmonary Vein/diagnostic imaging , Stenosis, Pulmonary Vein/etiology , Coronary Sinus/diagnostic imaging , Coronary Sinus/surgery , Coronary Vessel Anomalies/complications , Vascular Malformations/complications , Heart Septal Defects, Atrial/complications
18.
J Cardiovasc Magn Reson ; 24(1): 70, 2022 Dec 12.
Article in English | MEDLINE | ID: mdl-36503589

ABSTRACT

BACKGROUND: Pulmonary vein (PV) stenosis represents a rare but serious complication following radiofrequency ablation of atrial fibrillation with a comprehensive diagnosis including morphological stenosis grading together with the assessment of its functional consequences being imperative within the relatively narrow window for therapeutic intervention. The present study determined the clinical utility of a combined, single-session cardiovascular magnetic resonance (CMR) imaging protocol integrating pulmonary perfusion and PV angiographic assessment for pre-procedural planning and follow-up of patients referred for interventional PV stenosis treatment. METHODS: CMR examinations (cine imaging, dynamic pulmonary perfusion, three-dimensional PV angiography) were performed in 32 consecutive patients prior to interventional treatment of PV stenosis and at 1-day and 3-months follow-up. Degree of PV stenosis was visually determined on CMR angiography; visual and quantitative analysis of pulmonary perfusion imaging was done for all five lung lobes. RESULTS: Interventional treatment of PV stenosis achieved an acute procedural success rate of 90%. Agreement between visually evaluated pulmonary perfusion imaging and the presence or absence of a ≥ 70% PV stenosis was nearly perfect (Cohen's kappa, 0.96). ROC analysis demonstrated high discriminatory power of quantitative pulmonary perfusion measurements for the detection of ≥ 70% PV stenosis (AUC for time-to-peak enhancement, 0.96; wash-in rate, 0.93; maximum enhancement, 0.90). Quantitative pulmonary perfusion analysis proved a very large treatment effect attributable to successful PV revascularization already after 1 day. CONCLUSION: Integration of CMR pulmonary perfusion imaging into the clinical work-up of patients with PV stenosis allowed for efficient peri-procedural stratification and follow-up evaluation of revascularization success.


Subject(s)
Atrial Fibrillation , Catheter Ablation , Pulmonary Veins , Stenosis, Pulmonary Vein , Humans , Stenosis, Pulmonary Vein/diagnostic imaging , Stenosis, Pulmonary Vein/etiology , Stenosis, Pulmonary Vein/therapy , Pulmonary Veins/diagnostic imaging , Pulmonary Veins/surgery , Catheter Ablation/adverse effects , Constriction, Pathologic/etiology , Constriction, Pathologic/pathology , Constriction, Pathologic/surgery , Predictive Value of Tests , Atrial Fibrillation/diagnostic imaging , Atrial Fibrillation/surgery , Lung/diagnostic imaging , Magnetic Resonance Spectroscopy
19.
JACC Clin Electrophysiol ; 8(10): 1323-1333, 2022 10.
Article in English | MEDLINE | ID: mdl-36117046

ABSTRACT

Pulmonary vein stenosis (PVS) may arise from a variety of conditions and result in major morbidity and mortality. In some patients, pharmacologic therapy may help, but more often in advanced stages, mechanical treatment must be considered. Transcatheter approaches, both balloon angioplasty (BA) and stent implantation, have been applied. Although both are effective, they continue to be limited by restenosis. In this systematic review and meta-analysis, Ovid MEDLINE, Ovid Embase, Ovid Cochrane Central Register of Controlled Trials, Ovid Cochrane Database of Systematic Reviews, and Scopus were searched for English-language studies in humans published between January 1, 2010, and August 2, 2021. Two independent reviewers screened for studies in which BA or stenting was performed for PVS with reporting of restenosis outcomes, and data were independently extracted. A systematic review was performed, and overall restenosis rates were reported across all 34 included studies. Meta-analysis was then performed using RevMan version 5.4, assessing rates of restenosis and restenosis requiring reintervention in those studies with available data reported. For restenosis rates, 4 studies treated a total of 340 patients with 579 pulmonary vein interventions (225 with BA and 354 with stenting, mean follow-up 13-69 months). Restenosis requiring repeat intervention was reported in 3 studies, including 301 patients with 495 pulmonary vein interventions (157 with BA and 338 with stenting). Compared with BA, stenting was associated with both a lower risk for restenosis (risk ratio: 0.36; 95% CI: 0.18-0.73; P = 0.005) and a lower risk for restenosis requiring reintervention (RR: 0.36; 95% CI: 0.15-0.86; P = 0.02). For PVS intervention, restenosis and reintervention rates may be improved by stent implantation compared with BA.


Subject(s)
Angioplasty, Balloon , Pulmonary Veins , Stenosis, Pulmonary Vein , Humans , Stenosis, Pulmonary Vein/surgery , Stenosis, Pulmonary Vein/etiology , Angioplasty, Balloon/adverse effects , Stents/adverse effects , Pulmonary Veins/surgery , Constriction, Pathologic/surgery
SELECTION OF CITATIONS