Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 545
Filter
1.
Dentomaxillofac Radiol ; 53(7): 478-487, 2024 Oct 01.
Article in English | MEDLINE | ID: mdl-38991840

ABSTRACT

OBJECTIVES: Verify whether hypervigilance to pain (HP) and sleep quality (SQ) are confounding variables in the infrared thermography (IT) examination of the temporomandibular joint and temporal and masseter muscles. METHODS: A cross-sectional and analytical study was conducted, collecting HP and SQ data from 80 participants without temporomandibular disorders (TMD), performing their IT and another 40 participants with TMD. For the selection of participants with and without TMD, the TMD Pain Screener questionnaire and axis I of the Diagnostic Criteria for Temporomandibular Disorders were applied. SQ was verified using the Pittsburgh Sleep Quality Index (PSQI) questionnaire. For the HP assessment the Pain Vigilance and Awareness Questionnaire (PVAQ) was applied. And the IT was performed through a FLIR infrared sensor camera, model T650 Infrared. RESULTS: No significant correlations were found between SQ and the temperatures of the areas of interest (P > .05), and regarding HP, a statistically significant positive correlation was found with the dimensionless (ρ = 0.289) and non-dimensionless (ρ = 0.223) asymmetries of temporal muscle temperatures. In the temperature comparisons between the participants without TMD and the participants with TMD, significant differences were found (P < .05), also when the group without TMD was controlled according to both HP and SQ (P < .05), with higher temperatures found in the TMD group. CONCLUSIONS: HP and SQ can be considered confounding variables in IT examination of the temporomandibular region.


Subject(s)
Masseter Muscle , Temporomandibular Joint Disorders , Thermography , Humans , Thermography/methods , Female , Male , Cross-Sectional Studies , Masseter Muscle/physiopathology , Masseter Muscle/diagnostic imaging , Adult , Temporomandibular Joint Disorders/physiopathology , Temporomandibular Joint Disorders/diagnostic imaging , Facial Pain/physiopathology , Infrared Rays , Surveys and Questionnaires , Pain Measurement , Temporal Muscle/physiopathology , Temporal Muscle/diagnostic imaging , Temporomandibular Joint/physiopathology , Temporomandibular Joint/diagnostic imaging , Middle Aged , Anxiety/physiopathology , Sleep/physiology
2.
Physiol Rep ; 12(14): e16155, 2024 Jul.
Article in English | MEDLINE | ID: mdl-39039617

ABSTRACT

Numerous body locations have been utilized to obtain an accurate body temperature. While some are commonly used, their accuracy, response time, invasiveness varies greatly, and determines their potential clinical and/or research use. This review discusses human body temperature locations, their accuracy, ease of use, advantages, and drawbacks. We explain the concept of core body temperature and which of the locations achieve the best correlation to this temperature. The body locations include axilla, oral cavity, rectum, digestive and urinary tracts, skin, tympanic, nasopharynx, esophagus, and pulmonary artery. The review also discusses the latest temperature technologies, heat-flux technology and telemetric ingestible temperature pills, and the body locations used to validate these devices. Rectal and esophageal measurements are the most frequently used.


Subject(s)
Body Temperature , Humans , Body Temperature/physiology , Thermography/methods , Thermography/instrumentation , Thermometry/methods , Thermometry/instrumentation
3.
Int J Numer Method Biomed Eng ; 40(8): e3843, 2024 Aug.
Article in English | MEDLINE | ID: mdl-38963037

ABSTRACT

Infrared thermography is gaining relevance in breast cancer assessment. For this purpose, breast segmentation in thermograms is an important task for performing automatic image analysis and detecting possible temperature changes that indicate the presence of malignancy. However, it is not a simple task since the breast limit borders, especially the top borders, often have low contrast, making it difficult to isolate the breast area. Several algorithms have been proposed for breast segmentation, but these highly depend on the contrast at the lower breast borders and on filtering algorithms to remove false edges. This work focuses on taking advantage of the distinctive inframammary shape to simplify the definition of the lower breast border, regardless of the contrast level, which indeed also provides a strong anatomical reference to support the definition of the poorly marked upper boundary of the breasts, which has been one of the major challenges in the literature. In order to demonstrate viability of the proposed technique for an automatic breast segmentation, we applied it to a database with 180 thermograms and compared their results with those reported by others in the literature. We found that our approach achieved a high performance, in terms of Intersection over Union of 0.934, even higher than that reported by artificial intelligence algorithms. The performance is invariant to breast sizes and thermal contrast of the images.


Subject(s)
Algorithms , Breast , Thermography , Humans , Thermography/methods , Female , Breast/diagnostic imaging , Breast Neoplasms/diagnostic imaging , Infrared Rays , Image Processing, Computer-Assisted/methods
4.
BMC Res Notes ; 17(1): 197, 2024 Jul 17.
Article in English | MEDLINE | ID: mdl-39020384

ABSTRACT

OBJECTIVE: Conical orthopedic drill bits may have the potential to improve the stabilization of orthopedic screws. During perforations, heat energy is released, and elevated temperatures could be related to thermal osteonecrosis. This study was designed to evaluate the thermal behavior of an experimental conical drill bit, when compared to the conventional cylindrical drill, using polyurethane blocks perforations. RESULTS: The sample was divided into two groups, according to the method of drilling, including 25 polyurethane blocks in each: In Group 1, perforations were performed with a conventional orthopedic cylindrical drill; while in Group 2, an experimental conical drill was used. No statistically significant difference was observed in relation to the maximum temperature (MT) during the entire drilling in the groups, however the perforation time (PT) was slightly longer in Group 2. Each drill bit perforated five times and number of perforations was not correlated with a temperature increase, when evaluated universally or isolated by groups. The PT had no correlation with an increase in temperature when evaluating the perforations universally (n = 50) and in Group 1 alone; however, Group 2 showed an inversely proportional correlation for these variables, indicating that, for the conical drill bit, drillings with longer PT had lower MT.


Subject(s)
Polyurethanes , Thermography , Polyurethanes/chemistry , Thermography/methods , Temperature , Orthopedic Procedures/methods , Orthopedic Procedures/instrumentation , Orthopedic Procedures/adverse effects , Equipment Design , Bone Screws
5.
Yale J Biol Med ; 97(2): 225-238, 2024 Jun.
Article in English | MEDLINE | ID: mdl-38947102

ABSTRACT

Joint hypermobility syndromes, particularly chronic pain associated with this condition, including Hypermobile Ehlers-Danlos Syndrome (hEDS) and Hypermobility Spectrum Disorders (HSD), present diagnostic challenges due to their multifactorial origins and remain poorly understood from biomechanical and genomic-molecular perspectives. Recent diagnostic guidelines have differentiated hEDS, HSD, and benign joint hypermobility, providing a more objective diagnostic framework. However, incorrect diagnoses and underdiagnoses persist, leading to prolonged journeys for affected individuals. Musculoskeletal manifestations, chronic pain, dysautonomia, and gastrointestinal symptoms illustrate the multifactorial impact of these conditions, affecting both the physical and emotional well-being of affected individuals. Infrared thermography (IRT) emerges as a promising tool for joint assessment, especially in detecting inflammatory processes. Thermal distribution patterns offer valuable insights into joint dysfunctions, although the direct correlation between pain and inflammation remains challenging. The prevalence of neuropathies among hypermobile individuals accentuates the discordance between pain perception and thermographic findings, further complicating diagnosis and management. Despite its potential, the clinical integration of IRT faces challenges, with conflicting evidence hindering its adoption. However, studies demonstrate objective temperature disparities between healthy and diseased joints, especially under dynamic thermography, suggesting its potential utility in clinical practice. Future research focused on refining diagnostic criteria and elucidating the underlying mechanisms of hypermobility syndromes will be essential to improve diagnostic accuracy and enhance patient care in this complex and multidimensional context.


Subject(s)
Chronic Pain , Joint Instability , Thermography , Humans , Thermography/methods , Joint Instability/diagnosis , Joint Instability/physiopathology , Chronic Pain/diagnosis , Chronic Pain/physiopathology , Ehlers-Danlos Syndrome/diagnosis , Ehlers-Danlos Syndrome/physiopathology , Inflammation/diagnosis , Infrared Rays
6.
Arch Dermatol Res ; 316(7): 404, 2024 Jun 15.
Article in English | MEDLINE | ID: mdl-38878184

ABSTRACT

The aim of this study was to assess, through a systematic review, the status of infrared thermography (IRT) as a diagnostic tool for skin neoplasms of the head and neck region and in order to validate its effectiveness in differentiating benign and malignant lesions. A search was carried out in the LILACS, PubMed/MEDLINE, SCOPUS, Web of Science and EMBASE databases including studies published between 2004 and 2024, written in the Latin-Roman alphabet. Accuracy studies with patients aged 18 years or over presenting benign and malignant lesions in the head and neck region that evaluated the performance of IRT in differentiating these lesions were included. Lesions of mesenchymal origin and studies that did not mention histopathological diagnosis were excluded. The systematic review protocol was registered in the PROSPERO database (CRD42023416079). Reviewers independently analyzed titles, abstracts, and full-texts. After extracting data, the risk of bias of the selected studies was assessed using the QUADAS - 2 tool. Results were narratively synthesized and the certainty of evidence was measured using the GRADE approach. The search resulted in 1,587 records and three studies were included. Only one of the assessed studies used static IRT, while the other two studies used cold thermal stress. All studies had an uncertain risk of bias. In general, studies have shown wide variation in the accuracy of IRT for differentiating between malignant and benign lesions, with a low level of certainty in the evidence for both specificity and sensitivity.


Subject(s)
Head and Neck Neoplasms , Skin Neoplasms , Thermography , Humans , Thermography/methods , Skin Neoplasms/diagnosis , Diagnosis, Differential , Head and Neck Neoplasms/diagnosis , Sensitivity and Specificity , Skin/pathology , Neck
7.
Dentomaxillofac Radiol ; 53(6): 417-422, 2024 Sep 01.
Article in English | MEDLINE | ID: mdl-38810138

ABSTRACT

OBJECTIVES: To assess the influence of two conventional and one adapted cheek and lip retractors and three emissivity setting values on intraoral infrared thermography (IT) temperature values. METHODS: The sample was composed by 50 volunteers. Three cheek and lip retractors were tested: Group 1-flex retractor (FR); Group 2-FR adapted with Styrofoam; Group 3-U-type retractor (UR) for cheek and lip. All thermograms were acquired using FLIR T650 infrared camera. A set of three thermograms in frontal norm were acquired for each lip and cheek retractor at 0.91, 0.96, and 0.98ε, with an interval of 15 min between each set of images to avoid thermal interference. All images were assessed by two observers. The ROIs' mean temperature of the four upper incisors was recorded. Two-way ANOVA and Sidak post-test were used for data assessment with a significance level of 5%. RESULTS: Group 3 showed higher mean temperature than Groups 1 and 2 at all emissivity settings for all assessed teeth (P < .05). 0.91ε showed higher temperature than 0.96ε and 0.98ε for all assessed variables (P < .01). Contralateral teeth assessed using Group 3 at 0.91ε showed statistical differences between each other (P < .05). No statistical difference was observed between contralateral teeth assessed using Groups 1 and 2 at 0.96ε and 0.98ε (P > .05). CONCLUSIONS: The choice of cheek and lip retractor and emissivity setting can interfere on intraoral IT temperature values. U-type cheek and lip retractor and 0.91ε setting should not be used for IT image acquisition when assessing dental tissues.


Subject(s)
Cheek , Infrared Rays , Lip , Thermography , Humans , Thermography/methods , Thermography/instrumentation , Lip/diagnostic imaging , Cheek/diagnostic imaging , Male , Female , Adult , Equipment Design , Young Adult
8.
Gac Med Mex ; 160(1): 23-31, 2024.
Article in English | MEDLINE | ID: mdl-38753572

ABSTRACT

BACKGROUND: Endothelial dysfunction (ED) suspicion will allow to prevent accelerated atherosclerosis and premature death. OBJECTIVE: To establish the usefulness of thermography for endothelial function screening in adults with cardiovascular risk factors. MATERIAL AND METHODS: Cross-sectional, analytical diagnostic test. A brachial arterial diameter (BAD) increase < 11% at one-minute post-ischemia meant probable ED and was confirmed if BAD was ≥ 11% post-sublingual nitroglycerin. Thermographic photographs of the palmar region were obtained at one minute. Descriptive statistics, ROC curve, Mann-Whitney's U-test, chi-square test, or Fisher's exact test were used. RESULTS: Thirty-eight subjects with a median age of 50 years, and with 624 thermographic measurements were included. Nine had ED (flow-mediated vasodilation [FMV]: 2.5%). The best cutoff point for normal endothelial function in subjects with cardiovascular risk factors was ≥ 36 °C at one minute of ischemia, with 85% sensitivity, 70% specificity, positive and negative predictive values of 78 and 77%, area under the curve of 0.796, LR+ 2.82, LR- 0.22. CONCLUSION: An infrared thermography-measured temperature in the palmar region greater than or equal to 36 °C after one minute of ischemia is practical, non-invasive, and inexpensive for normal endothelial function screening in adults with cardiovascular risk factors.


ANTECEDENTES: La sospecha de disfunción endotelial (DE) permitirá prevenir la aterosclerosis acelerada y la muerte prematura. OBJETIVO: Establecer la utilidad de la termografía en el cribado de la función endotelial en adultos con factores de riesgo cardiovascular. MATERIAL Y MÉTODOS: Estudio transversal analítico de prueba diagnóstica. El incremento del diámetro de la arteria braquial < 11 % a un minuto posisquemia significó probable DE, confirmada si el diámetro fue ≥ 11 % posnitroglicerina sublingual. Se obtuvieron fotografías termográficas al minuto de la región palmar. Se aplicó estadística descriptiva, curva ROC, pruebas U de Mann-Whitney, chi cuadrada o exacta de Fisher. RESULTADOS: Se incluyeron 38 sujetos, mediana de edad de 50 años, con 624 mediciones termográficas; nueve presentaron DE (vasodilatación mediada por flujo de 2.5 %). El mejor punto de corte para la función endotelial normal en sujetos con factores de riesgo cardiovascular fue ≥ 36 °C al minuto de isquemia, con sensibilidad de 85%, especificidad de 70%, valores predictivos positivo y negativo de 78 y 77%, área bajo la curva de 0.796, razón de verisimilitud positiva de 2.82 y razón de verisimilitud negativa de 0.22. CONCLUSIÓN: La medición de la temperatura en la región palmar mediante termografía infrarroja ≥ 36 °C tras un minuto de isquemia es práctica, no invasiva y económica para el cribado de la función endotelial normal en adultos con factores de riesgo cardiovascular.


Subject(s)
Endothelium, Vascular , Thermography , Humans , Thermography/methods , Middle Aged , Male , Female , Cross-Sectional Studies , Endothelium, Vascular/physiopathology , Adult , Aged , Heart Disease Risk Factors , Sensitivity and Specificity , Infrared Rays , Brachial Artery/physiology , Cardiovascular Diseases/diagnosis , Cardiovascular Diseases/physiopathology , Vasodilation/physiology , Predictive Value of Tests
9.
J Med Primatol ; 53(3): e12711, 2024 Jun.
Article in English | MEDLINE | ID: mdl-38790083

ABSTRACT

BACKGROUND: This study used infrared thermography (IRT) for mapping the facial and ocular temperatures of howler monkeys, to determine parameters for the diagnosis of febrile processes. There are no published IRT study in this species. METHODS: Were evaluated images of a group of monkeys kept under human care at Sorocaba Zoo (São Paulo, Brazil). The images were recorded during 1 year, in all seasons. Face and eye temperatures were evaluated. RESULTS: There are statistically significant differences in face and eye temperatures. Mean values and standard deviations for facial and ocular temperature were respectively: 33.0°C (2.1) and 36.5°C (1.9) in the summer; 31.5°C (4.5) and 35.3°C (3.6) in the autumn; 30.0°C (4.3) and 35.6°C (3.9) in the winter; 30.8°C (2.9) and 35.5°C (2.1) in the spring. CONCLUSIONS: The IRT was effective to establish a parameter for facial and ocular temperatures of black-and-gold howler monkeys kept under human care.


Subject(s)
Alouatta , Body Temperature , Eye , Face , Infrared Rays , Thermography , Animals , Thermography/veterinary , Thermography/methods , Alouatta/physiology , Male , Seasons , Female , Fever/veterinary , Fever/diagnosis , Animals, Zoo
10.
Codas ; 36(2): e20220323, 2024.
Article in Portuguese, English | MEDLINE | ID: mdl-38629647

ABSTRACT

PURPOSE: To present a method for analyzing breathing modes with infrared thermography. METHODS: This exploratory cross-sectional study used 38 thermal images of inspiration and expiration with nasal breathing and simulated mouth breathing in four nasal breathers without respiratory complaints. Three different data selection forms (line, rectangle, and ellipse) were used to extract the minimum, mean, and maximum temperatures of the regions of interest (nose and mouth) using the FLIR Tools® software. RESULTS: Among the three selection forms, there was greater temperature variability obtained with the line, revealing limitations in this measurement. There were no differences between the rectangle and ellipse values, showing that both selection forms present similar temperature extraction results. The comparison results between nose and mouth temperatures during inspiration and expiration indicated a statistically significant difference between all measurements, except for mean inspiration temperatures with the rectangle and ellipse. The breathing mode can be distinguished in both inspiration and expiration when using mean mouth temperatures with the rectangle and ellipse. CONCLUSION: Breathing modes should be assessed based on mean mouth temperatures during inspiration, using the ellipse.


OBJETIVO: Apresentar um método de análise do modo respiratório por meio da termografia infravermelha. MÉTODO: Estudo transversal exploratório de 38 imagens térmicas que representavam o momento da inspiração e da expiração durante a respiração nasal e durante a simulação da respiração oral de quatro voluntárias respiradoras nasais sem queixas respiratórias. Para a extração da temperatura das regiões de interesse (nariz e boca) foram utilizadas três formas de seleção distintas de dados (linha, retângulo e elipse) e três medidas de temperatura (mínima, média e máxima) por meio do software FLIR Tools®. RESULTADOS: Dentre as três formas de seleção houve maior variabilidade nas medidas obtidas pela linha, revelando limitações nessa medida. Não houve diferenças entre as medidas do retângulo e elipse, mostrando que ambas as formas de seleção apresentam resultados semelhantes para a extração das temperaturas. Na comparação entre as temperaturas do nariz e da boca na inspiração e expiração, os resultados indicaram que houve diferença com relevância estatística em todas as medidas realizadas, exceto para as medidas de temperatura média da inspiração, usando o retângulo e a elipse. Percebe-se diferenciação do modo respiratório tanto na inspiração quanto na expiração quando utilizada a temperatura média da boca com o retângulo e a elipse. CONCLUSÃO: Sugere-se para avaliação do modo respiratório a avaliação da boca, por meio da elipse, com análise da temperatura média durante a inspiração.


Subject(s)
Respiration , Thermography , Humans , Pilot Projects , Cross-Sectional Studies , Nose , Mouth Breathing
11.
J Wound Care ; 33(Sup4a): cxviii-cxxix, 2024 Apr 02.
Article in English | MEDLINE | ID: mdl-38588060

ABSTRACT

OBJECTIVE: Accurate assessment of burn depth and burn wound healing potential is essential to determine early treatments. Infrared thermography (IRT) is a non-invasive and objective tool to do this. This systematic review evaluated the accuracy of IRT to determine burn wound healing potential. METHOD: This systematic review and meta-analysis used MEDLINE, EMBASE, CINAHL, PEDro, DiTA and CENTRAL databases. IRT data were extracted from primary studies and categorised into four cells (i.e., true positives, false positives, true negatives and false negatives). Subgroup analysis was performed according to methods used to capture thermal images. RESULTS: The search strategy identified 2727 publications; however, 15 articles were selected for review and 11 for meta-analysis. In our meta-analysis, the accuracy of IRT was 84.8% (63% sensitivity and 81.9% specificity). CONCLUSION: IRT is a moderately accurate tool to identify burn depth and healing potential. Thus, IRT should be used carefully for evaluating burn wounds.


Subject(s)
Burns , Thermography , Humans , Thermography/methods , Wound Healing , Burns/diagnosis , Burns/therapy , Acetophenones
12.
Reprod Domest Anim ; 59(4): e14556, 2024 Apr.
Article in English | MEDLINE | ID: mdl-38566398

ABSTRACT

Scrotal surface thermography is a non-invasive method for assessing testicular thermoregulation in stallions; however, few studies have explored the application of this technique concerning the thermal physiology of equine reproductive systems. This study aimed to evaluate the consistency of testicular thermoregulation in stallions over a year using thermography to measure the scrotal surface temperature (SST). Moreover, we assessed the best region for measuring the surface body temperature compared with the SST. Ten light-breed stallions were used in the experiment. Thermographic images of the scrotal and body surfaces (neck and abdomen) were captured. Fresh, cooled and frozen-thawed semen samples were evaluated to verify the impact of thermoregulation on semen quality. Testicular thermoregulation was maintained throughout the year in stallions amidst changes in the external temperature, as evidenced by the weak correlation between the SST and ambient temperature. A lower correlation was observed between the environmental temperature and body surface temperature (BTS) obtained from the abdomen (BTS-A; R = .4772; p < .0001) than with that obtained from the neck (BTS-N; R = .7259; p < .0001). Moreover, both BTS-A and SST were simultaneously captured in a single image. The consistent quality of the fresh, cooled and frozen semen suggests efficient thermoregulation in stallions throughout the year.


Subject(s)
Semen Analysis , Thermography , Animals , Horses , Male , Temperature , Thermography/veterinary , Thermography/methods , Semen Analysis/veterinary , Scrotum/physiology , Testis/physiology , Semen/physiology
13.
Clin Physiol Funct Imaging ; 44(4): 324-331, 2024 Jul.
Article in English | MEDLINE | ID: mdl-38544320

ABSTRACT

OBJECTIVE: To compare the thermographic pattern of regions of interest (ROI) of respiratory muscles in young asthmatics with and without bronchospasm induced by eucapnic voluntary hyperpnea (EVH). MATERIALS AND METHODS: Cross-sectional study carried out with 55 young (55% male and 45% females) aged 12.5 ± 3.3 years, divided in nine nonasthmatics, 22 asthmatics without exercise-induced bronchospasm compatible response (EIB-cr) and 24 asthmatics with EIB-cr. The diagnosis of EIB was given to subjects with a fall in forced expiratory volume in the first second (FEV1) ≥ 10% compared to baseline. Thermographic recordings of respiratory muscles were delimited in ROI of the sternocleidomastoid (SCM), pectoral, and rectus abdominis intention area. Thermal captures and FEV1 were taken before and 5, 10, 15 and 30 min after EVH. RESULTS: Twenty-four (52.1%) of asthmatics had EIB-cr. There was a decrease in temperature at 10 min after EVH test in the SCM, pectoral and rectus abdominis ROIs in all groups (both with p < 0.05). There was a decrease in temperature (% basal) in asthmatic with EIB-cr compared to nonasthmatics in the rectus abdominis area (p < 0.05). CONCLUSION: There was a decrease in temperature in the ROIs of different muscle groups, especially in asthmatics. The greater drop in FEV1 observed in individuals with EIB-cr was initially associated with a decrease in skin temperature, with a difference between the nonasthmatics in the abdominal muscle area. It is likely that this decrease in temperature occurred due to a temporary displacement of blood flow to the most used muscle groups, with a decrease in the region of the skin evaluated in the thermography.


Subject(s)
Predictive Value of Tests , Respiratory Muscles , Thermography , Humans , Male , Female , Cross-Sectional Studies , Child , Adolescent , Respiratory Muscles/physiopathology , Forced Expiratory Volume , Thermography/methods , Case-Control Studies , Time Factors , Asthma, Exercise-Induced/physiopathology , Asthma, Exercise-Induced/diagnosis , Lung/physiopathology , Age Factors , Asthma/physiopathology , Asthma/complications , Asthma/diagnosis , Hyperventilation/physiopathology , Bronchial Spasm/physiopathology , Bronchial Spasm/etiology
14.
Meat Sci ; 213: 109483, 2024 Jul.
Article in English | MEDLINE | ID: mdl-38484580

ABSTRACT

This study investigated the use of infrared thermography (IRT) to identify the dark, firm, and dry (DFD) phenomenon in Brazilian beef, which is a significant concern for the industry because of its inferior quality and reduced shelf life. This study examined 113 Nellore bulls and analyzed their minimum and maximum ocular temperatures using IRT. The results highlight the efficacy of thermal images (IRTmax) as a significant predictor, with R2 values ranging from 0.84 to 0.88 for calibration models. The inclusion of parameters such as glucose and lactate further enhanced prediction accuracy. The models also revealed that the combination of features, such as lightness (L*), redness (a*), and yellowness (b*), contributed to the precise prediction of pHu, with an R2 of 0.88. In model validation, RMSEP ranged from 0.104 to 0.158, indicating good generalization capability. The RPD, ranging from 1.7 to 2.6, suggests satisfactory quantitative prediction. The statistical significance of all models, evidenced by P-values <0.001, strengthens the reliability of the results. In conclusion, the models support the use of IRT as a tool for identifying pHu alterations in carcasses. When combined with blood parameters, they may exhibit even greater efficiency in predicting pHu in Nelore cattle carcasses, highlighting the potential applicability of these methods in the beef industry.


Subject(s)
Red Meat , Thermography , Animals , Cattle , Thermography/veterinary , Thermography/methods , Hydrogen-Ion Concentration , Red Meat/analysis , Male , Color , Infrared Rays , Food Quality , Reproducibility of Results , Brazil
15.
Vet Res Commun ; 48(3): 1935-1939, 2024 Jun.
Article in English | MEDLINE | ID: mdl-38470524

ABSTRACT

In the present study we aimed to investigate superficial skin temperature of racehorses' distal limbs after training in a racetrack. Male and female Thoroughbred racehorses were investigated in summer, after light training, and in the winter, after light and intense training. Horses were exercised (Exercise group, EG) under trainers' protocol while others were maintained inside their stalls (Control group, CG). Thermographic images were obtained from the front (fetlock, cannon, and carpus) and hindlimbs (fetlock, cannon, and tarsus), before exercise and 45, 60, 120 and 180 min after exercising. Images were analyzed using the Flir Tools® program. Temperatures of different moments of each group were compared using Anova for repeated measures and each moment of EG versus CG using Student t test. Horses of the CG maintained steady temperature in the winter, but in summer temperature increased at M45 until M180 (P < 0,01). EG increased temperatures after exercises that remained higher than M0 even at 180 min post-exercise (P < 0,0001), for most of the regions in winter and summer. EG temperatures were higher than CG at most of the time points after exercise. There was positive correlation between all regions' temperature and the atmospheric temperature for the CG during the summer (P = 0,003, r2 = 0,9622), observed for the front fetlock and carpal regions for the EG (P = 0.035, r2 = 0,8166). This pilot study demonstrates that, after race exercising under natural conditions skin temperature might take more than 180 min to return to basal values.


Subject(s)
Physical Conditioning, Animal , Seasons , Skin Temperature , Animals , Horses/physiology , Physical Conditioning, Animal/physiology , Female , Male , Hindlimb/physiology , Forelimb/physiology , Thermography/veterinary
16.
J Therm Biol ; 119: 103782, 2024 Jan.
Article in English | MEDLINE | ID: mdl-38176292

ABSTRACT

Enhanced vascular permeability at the site of injury is a prominent feature in acute inflammatory pain models, commonly assessed through the Evans Blue test. However, this invasive test requires euthanasia, thereby precluding further investigations on the same animal. Due to these limitations, the integration of non-invasive tools such as IRT has been sought. Here, we aimed to evaluate the use of thermography in a common orofacial pain model that employs formalin as a chemical irritant to induce local orofacial inflammation. Male Hannover rats (290-300 g, N = 43) were used. In the first approach, radiometric images were taken before and after formalin administration, assessing temperature changes and extravasated Evans Blue. The second approach included capturing pre- and post-formalin test radiometric images, followed by cytokine measurements in excised vibrissae tissue. Rats were anesthetized for vibrissae tissue collection, allowing correlations between thermographic patterns, nocifensive behavior duration, and cytokine levels in this area. Our findings revealed a positive correlation between local temperature, measured via thermography, and vascular permeability in the contralateral (r2 = 0.3483) and ipsilateral (r2 = 0.4502) side, measured using spectrophotometry. The obtained data supports the notion that thermography-based temperature assessment can effectively evaluate vascular permeability in the orofacial region.


Subject(s)
Formaldehyde , Thermography , Rats , Male , Animals , Formaldehyde/adverse effects , Thermography/methods , Capillary Permeability , Evans Blue/adverse effects , Facial Pain/chemically induced , Cytokines
17.
Int. j. morphol ; 41(6): 1824-1832, dic. 2023. ilus, tab
Article in Spanish | LILACS | ID: biblio-1528780

ABSTRACT

La termografía por infrarrojo (TI) permite evaluar la temperatura corporal, medir los cambios en la disipación del calor corporal en superficie y relacionarlos con las características de composición corporal e índices antropométricos. Aumentar el número de registros de zonas corporales evaluadas con TI y establecer las relaciones de estas temperaturas (32 áreas corporales) con variables de composición corporal e índices antropométricos, como el índice de masa corporal (IMC), índice cintura cadera, índice cintura estatura, en hombres adultos divididos según su estado ponderal. Participaron 60 hombres, adultos sanos, divididos en 2 grupos: grupo 1 (n=30), con IMC ≤ 24,9, edad 23,2 ± 3,9 años, masa corporal 66,5 ± 6,5 kg, y talla 170,5 ± 7,4 cm; y, grupo 2 (n= 30), con IMC > 24,9, edad 29,4 ± 9,9 años, masa corporal 84,5 ± 11,9 kg, y talla 172,0 ± 7,18 cm. Se realizaron evaluaciones antropométricas y de TI. Sujetos con IMC ≤ 24,9 kg/ m2 presentaron valores mayores de temperatura superficial, en todas las zonas estudiadas, a diferencia de los sujetos con niveles de IMC > 24,9 kg/m2, donde la disipación del calor corporal fue menor. Existe una estrecha relación entre la temperatura superficial de la piel y el IMC, donde sujetos con un IMC normal mostraron una disipación de calor y valores de temperatura superficial mayores, en todas las zonas evaluadas, a diferencia de los sujetos con un IMC que se encontraba por encima del límite de normalidad.


SUMMARY: Infrared thermography (IT) makes it possible to assess body temperature, measure changes in body heat dissipation on the surface, and relate them to body composition characteristics and anthropometric indices. The objective of this study was to increase the number of records of body areas evaluated with IT and establish the relationships of these temperatures (32 body areas) with body composition variables and anthropometric indices, such as body mass index (BMI), waist-hip ratio, waist-height ratio, in adult men divided according to their weight status. A total of 60 healthy adult men participated, divided into 2 groups: group 1 (n=30), with a body mass index (BMI) ≤ 24.9, age 23.2 ± 3.9 years, body mass 66.5 ± 6.5 kg, and height 170.5 ± 7.4 cm; and, group 2 (n = 30), with BMI > 24.9, age 29.4 ± 9.9 years, body mass 84.5 ± 11.9 kg, and height 172.0 ± 7.18 cm. Anthropometric and IT assessments were performed. Subjects with BMI ≤ 24.9 kg/ m2 presented higher values of surface temperature in all areas studied, unlike subjects with BMI levels > 24.9 kg/m2, where body heat dissipation was lower. There is a close relationship between skin surface temperature and BMI, where subjects with a normal BMI showed higher heat dissipation and surface temperature values, in all evaluated areas, unlike subjects with a BMI that was above the normal limit.


Subject(s)
Humans , Male , Adult , Young Adult , Body Composition , Body Temperature , Anthropometry , Skinfold Thickness , Thermography , Body Mass Index , Waist-Hip Ratio , Overweight , Waist-Height Ratio , Obesity
18.
Clin Oral Investig ; 27(12): 7705-7714, 2023 Dec.
Article in English | MEDLINE | ID: mdl-37924357

ABSTRACT

OBJECTIVES: To evaluate the clinical and thermographic aspects of the gingival phenotype (GP) in healthy subjects. MATERIALS AND METHODS: The study sample examined 264 teeth, upper and lower incisors, comprising 132 central incisors (CI) and 132 lateral incisors (LI), in 33 healthy volunteers. Four periodontal parameters were recorded systematically: ratio of width to length of the dental crown (CW/CL), height of the gingival attachment (KGW), probing depth (PD), and gingival transparency (GT). The temperatures of the attached gingiva (KGW temp) and the free gingival margin (FGM Temp) were also recorded by way of infrared thermography (IRT). RESULTS: The average age of the sample was 30.70 ± 7.65 years. Of the 264 teeth evaluated, 76.1% had a thin GP. There was a significant association between CW/CL (p < 0.001), KGW (p < 0.001), PD (p < 0.007), and FGM Temp (p < 0.006) with the tooth groups. The results show a significant and inversely proportional correlation between clinical parameters and gingival temperature (p < 0.05). A significant association was found between CW/CL (p < 0.026); KGW (p < 0.001); and GP. CONCLUSION: CW/CL, KGW, PD, and FGM Temp vary according to tooth group. The majority of the sample presented with the thin GP, which was more prevalent in the lower LIs and CIs. No significant association could be observed between thermographic parameters and GP. CLINICAL RELEVANCE: Knowledge of the temperature of the gingival tissues can be useful in helping to diagnose and plan periodontal treatments. Moreover, our findings will help future studies evaluate the use of IR as an auxiliary diagnostic method in dentistry, eliminating GP as a confounding factor, since it does not seem to influence the temperature of the gingival tissues.


Subject(s)
Gingiva , Gingival Diseases , Humans , Young Adult , Adult , Gingiva/anatomy & histology , Thermography , Incisor/anatomy & histology , Phenotype
19.
Trop Anim Health Prod ; 55(6): 373, 2023 Oct 24.
Article in English | MEDLINE | ID: mdl-37874396

ABSTRACT

This study evaluated the welfare of Saanen, Moxoto, and Anglo-Nubian goats kept in collective or individual pens for a feedlot system, evaluated with infrared thermography. A total of twenty-four goats were used, eight for each breed. Animals were distributed in a completely randomized design, with a 2 × 3 factorial with two fixed effects: housing type (collective or individual pens) and breed (Moxoto, Saanen, and Anglo-Nubian). The surface temperature was evaluated using an infrared thermographic camera, and behavioral analysis was based on the qualitative behavior assessment using a fixed list of descriptors. The breed was not different for all behavior evaluations and surface temperature (p>0.05). There was a difference between the housing types, where the collective pens showed goats more agitated, frustrated, and sociable (p<0.05). There was an influence of agitated, apathetic, frustrated, attentive, and curious behaviors on surface temperatures, in which feet and body temperatures decreased in these goats. (p<0.05). Moxoto, Anglo-Nubian, and Saanen goats showed similar behavior even when kept in collective or individual pens. Individual pens can restrict the goats' social relationships but reduce negative behaviors such as irritation and frustration. The lower foot temperatures of feedlot goats are related to the attention behavior in 86.75% of the observations.


Subject(s)
Goats , Thermography , Animals , Temperature , Thermography/veterinary
20.
Article in English | MEDLINE | ID: mdl-37835137

ABSTRACT

(1) Infrared thermography of the inner canthus of the eye has emerged as a promising tool for temperature screening and fever diagnosis. Its non-invasive nature lends itself well to mass screening in diverse settings such as schools, public transport, and healthcare facilities. Swift and accurate temperature assessment plays a pivotal role in the early identification of potential fever cases, facilitating timely isolation, testing, and treatment, thereby mitigating the risk of disease transmission. Nonetheless, the reliability of this approach in the pediatric population, especially when compared to conventional thermometry methods, remains unexplored. This preliminary study aimed to evaluate the concordance between the temperature of the inner canthus of the eye (Tic,eye), referred to as the brain-eyelid thermal tunnel (BTT°), with axillary and tympanic methods in afebrile children. (2) Methods: A cohort of 36 children, matched in a 1:1 ratio for gender and age, underwent comprehensive assessments encompassing anthropometric data, blood pressure evaluations, axillary (Tax) and tympanic (Tty) temperature measurements, as well as BTT° infrared thermography. (3) Results: The findings revealed a high level of concordance among the tympanic, axillary, and BTT° measurement methods. Bland-Altman plots showed that the bias was minimal, and no statistically significant differences were observed when comparing BTT° with axillary (p = 0.136) and tympanic (p = 0.268) measurements. Passing-Bablok regression scatter plots further confirmed the agreement, aligning the fitted regression line closely with the identity line for both axillary versus BTT° and tympanic (Tty) versus BTT° comparisons. (4) Conclusions: This study holds significant implications for public health, especially in the context of infectious disease outbreaks such as COVID-19. BTT° infrared thermography of the inner canthus of the eye (Tic,eye) reliably measures body temperature in afebrile children in controlled settings; nevertheless, its practical application necessitates the adaptation of biothermodynamic parameters to accommodate diverse environmental conditions.


Subject(s)
Body Temperature , Thermometers , Humans , Child , Body Temperature/physiology , Reproducibility of Results , Fever/diagnosis , Thermography/methods , Brain , Eyelids
SELECTION OF CITATIONS