Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 24.357
Filter
1.
Appl Ergon ; 120: 104342, 2024 Oct.
Article in English | MEDLINE | ID: mdl-38959633

ABSTRACT

This research sought to evaluate the thermal zones of the upper body and firefighter personal protective equipment (PPE) immediately following uncompensable heat stress (0.03 °C increase/min). We hypothesized that the frontal portion of the head and the inside of the firefighter helmet would be the hottest as measured by infrared thermography. This hypothesis was due to previous research demonstrating that the head accounts for ∼8-10% of the body surface area, but it accounts for ∼20% of the overall body heat dissipation during moderate exercise. Twenty participants performed a 21-min graded treadmill exercise protocol (Altered Modified Naughton) in an environmental chamber (35 °C, 50 % humidity) in firefighter PPE. The body areas analyzed were the frontal area of the head, chest, abdomen, arm, neck, upper back, and lower back. The areas of the PPE that were analyzed were the inside of the helmet and the jacket. The hottest areas of the body post-exercise were the frontal area of the head (mean: 37.3 ± 0.4 °C), chest (mean: 37.5 ± 0.3 °C), and upper back (mean: 37.3 ± 0.4 °C). The coldest area of the upper body was the abdomen (mean: 36.1 ± 0.4 °C). The peak temperature of the inside of the helmet increased (p < 0.001) by 9.8 °C from 27.7 ± 1.6 °C to 37.4 ± 0.7 °C, and the inside of the jacket increased (p < 0.001) by 7.3 °C from 29.2 ± 1.7 °C to 36.5 ± 0.4 °C. The results of this study are relevant for cooling strategies for firefighters.


Subject(s)
Firefighters , Heat Stress Disorders , Thermography , Humans , Thermography/methods , Male , Adult , Heat Stress Disorders/prevention & control , Heat Stress Disorders/etiology , Head Protective Devices , Body Temperature/physiology , Personal Protective Equipment , Infrared Rays , Head/physiology , Female , Young Adult , Exercise Test/methods , Body Temperature Regulation/physiology , Thorax/physiology , Abdomen/physiology , Hot Temperature
3.
J Infect Dev Ctries ; 18(6): 978-981, 2024 Jun 30.
Article in English | MEDLINE | ID: mdl-38990993

ABSTRACT

INTRODUCTION: Mycetoma is a chronic granulomatous inflammatory disease of the subcutaneous tissue, which affects deep structures and bone. Most cases of actinomycetoma are caused by members of the genus Nocardia. CASE PRESENTATION: Here we report the case of a 43-year-old male who presented a disseminated mycetoma on the forearm, chest and neck, characterized by enlarged and erythematous lesions through which seropurulent material drains, and numerous atrophic scars. Molecular identification was performed by 16S gene amplification and sequencing. Nocardia mexicana was identified with 100% identity. Trimethoprim-sulfamethoxazole, diaminodiphenyl sulfone and amikacin was a successful treatment after 6 months. CONCLUSIONS: Nocardia mexicana is a rare organism that causes mycetoma. We report a case of extensive mycetoma on the forearm with spread to the neck and thorax associated with manipulation of the mouth of a calf.


Subject(s)
Anti-Bacterial Agents , Forearm , Mycetoma , Neck , Nocardia Infections , Nocardia , RNA, Ribosomal, 16S , Thorax , Humans , Male , Adult , Nocardia/isolation & purification , Nocardia/genetics , Mycetoma/microbiology , Mycetoma/drug therapy , Mycetoma/diagnosis , Nocardia Infections/microbiology , Nocardia Infections/drug therapy , Nocardia Infections/diagnosis , Forearm/microbiology , Forearm/pathology , Thorax/diagnostic imaging , Thorax/microbiology , Neck/pathology , Anti-Bacterial Agents/therapeutic use , RNA, Ribosomal, 16S/genetics , Sequence Analysis, DNA , DNA, Bacterial/genetics , Treatment Outcome , Trimethoprim, Sulfamethoxazole Drug Combination/therapeutic use , Amikacin/therapeutic use , DNA, Ribosomal/genetics , DNA, Ribosomal/chemistry
4.
Zhongguo Dang Dai Er Ke Za Zhi ; 26(7): 730-735, 2024 Jul 15.
Article in Chinese | MEDLINE | ID: mdl-39014950

ABSTRACT

OBJECTIVES: To study chest computed tomography (CT) manifestations in neonates with chronic granulomatous disease (CGD) to provide clues for early diagnosis of this disease. METHODS: A retrospective analysis was conducted on the clinical data and chest CT scan results of neonates diagnosed with CGD from January 2015 to December 2022 at Anhui Provincial Children's Hospital. RESULTS: Nine neonates with CGD were included, with eight presenting respiratory symptoms as the initial sign. Chest CT findings included: consolidation in all 9 cases; nodules in all 9 cases, characterized by multiple, variably sized scattered nodules in both lungs; masses in 4 cases; cavities in 3 cases; abscesses in 6 cases; bronchial stenosis in 2 cases; pleural effusion, interstitial changes, and mediastinal lymphadenopathy each in 1 case. CT enhancement scans showed nodules and masses with uneven or ring-shaped enhancement; no signs of pulmonary emphysema, lung calcification, halo signs, crescent signs, bronchiectasis, or scar lesions were observed. There was no evidence of rib or vertebral bone destruction. Fungal infections were present in 8 of the 9 cases, including 6 with Aspergillus infections; three of these involved mixed infections with Aspergillus, with masses most commonly associated with mixed Aspergillus infections (3/4). CONCLUSIONS: The primary manifestations of neonatal CGD on chest CT are consolidation, nodules, and/or masses, with Aspergillus as a common pathogen. These features can serve as early diagnostic clues for neonatal CGD.


Subject(s)
Granulomatous Disease, Chronic , Tomography, X-Ray Computed , Humans , Granulomatous Disease, Chronic/diagnostic imaging , Infant, Newborn , Male , Female , Retrospective Studies , Thorax/diagnostic imaging
5.
J Transl Med ; 22(1): 609, 2024 Jul 02.
Article in English | MEDLINE | ID: mdl-38956586

ABSTRACT

Sustained injury from factors such as hypoxia, infection, or physical damage may provoke improper tissue repair and the anomalous deposition of connective tissue that causes fibrosis. This phenomenon may take place in any organ, ultimately leading to their dysfunction and eventual failure. Tissue fibrosis has also been found to be central in both the process of carcinogenesis and cancer progression. Thus, its prompt diagnosis and regular monitoring is necessary for implementing effective disease-modifying interventions aiming to reduce mortality and improve overall quality of life. While significant research has been conducted on these subjects, a comprehensive understanding of how their relationship manifests through modern imaging techniques remains to be established. This work intends to provide a comprehensive overview of imaging technologies relevant to the detection of fibrosis affecting thoracic organs as well as to explore potential future advancements in this field.


Subject(s)
Fibrosis , Humans , Thorax/diagnostic imaging , Thorax/pathology
6.
BMC Vet Res ; 20(1): 299, 2024 Jul 06.
Article in English | MEDLINE | ID: mdl-38971722

ABSTRACT

BACKGROUND: Research on the effects of physical exercise on canine body composition is limited. The aim of this study was to investigate the effects of a physical exercise programme on bodyweight, body condition score (BCS) and chest, abdominal and thigh circumferences in dogs. Twenty-one healthy dogs of different breeds exercised together with their owners during an eight-week programme consisting of jogging and strength exercises. Standardised measurements were performed in triplicates with a measuring tape on standing dogs. Chest circumference was measured at three anatomical locations, abdomen at two and thigh at one. Data on bodyweight, BCS (9-point scale) and circumferences were analysed with mixed model repeated measures analyses to evaluate changes after the programme and effects of target distance. RESULTS: Seven dog owners choose a target distance of 2 km and 14 owners choose 5-10 km. Mean BCS decreased (P = 0.007) after the programme (5.1 ± 0.9 vs. 4.7 ± 0.6) but there was no effect of target distance. Almost all chest and abdominal circumference measurements decreased (P ≤ 0.007) with the 2 km group driving the reduction in chest circumference and the 5-10 km group driving the reduction in abdominal circumference. In contrast, thigh circumference (28.8 ± 0.4 vs. 30.2 ± 0.4) increased (P = 0.007) while bodyweight was maintained. There were positive correlations between BCS and abdominal/chest ratios before and after the programme (Pearson correlation; R square ≤ 0.43, P ≤ 0.0012) but the mean ratio remained constant. CONCLUSIONS: Results indicated a redistribution between total body fat and muscle mass in body composition of normal weight to slightly overweight dogs after the physical exercise programme. The use of bodyweight alone was not a reliable evaluation method to complement the BCS assessment. However, repeated measurements of chest, abdominal and thigh circumference might aid in the assessment of body composition in dogs performing physical exercise. Further research should include a control group and objective evaluations of total body fat and lean mass, in order to investigate the effectiveness of physical exercise as a freestanding method for decreasing BCS and increasing muscle mass in overweight dogs.


Subject(s)
Body Composition , Body Weight , Physical Conditioning, Animal , Thorax , Animals , Dogs/physiology , Male , Female , Thorax/anatomy & histology , Abdomen/anatomy & histology , Thigh/anatomy & histology
7.
Physiol Meas ; 45(7)2024 Jul 12.
Article in English | MEDLINE | ID: mdl-38959902

ABSTRACT

Objective.Electrical impedance tomography (EIT) has been used to determine regional lung ventilation distribution in humans for decades, however, the effect of biological sex on the findings has hardly ever been examined. The aim of our study was to determine if the spatial distribution of ventilation assessed by EIT during quiet breathing was influenced by biological sex.Approach.219 adults with no known acute or chronic lung disease were examined in sitting position with the EIT electrodes placed around the lower chest (6th intercostal space). EIT data were recorded at 33 images/s during quiet breathing for 60 s. Regional tidal impedance variation was calculated in all EIT image pixels and the spatial distribution of the values was determined using the established EIT measures of centre of ventilation in ventrodorsal (CoVvd) and right-to-left direction (CoVrl), the dorsal and right fraction of ventilation, and ventilation defect score.Main results.After exclusion of one subject due to insufficient electrode contact, 218 data sets were analysed (120 men, 98 women) (age: 53 ± 18 vs 50 ± 16 yr (p= 0.2607), body mass index: 26.4 ± 4.0 vs 26.4 ± 6.6 kg m-2(p= 0.9158), mean ± SD). Highly significant differences in ventilation distribution were identified between men and women between the right and left chest sides (CoVrl: 47.0 ± 2.9 vs 48.8 ± 3.3% of chest diameter (p< 0.0001), right fraction of ventilation: 0.573 ± 0.067 vs 0.539 ± 0.071 (p= 0.0004)) and less significant in the ventrodorsal direction (CoVvd: 55.6 ± 4.2 vs 54.5 ± 3.6% of chest diameter (p= 0.0364), dorsal fraction of ventilation: 0.650 ± 0.121 vs 0.625 ± 0.104 (p= 0.1155)). Ventilation defect score higher than one was found in 42.5% of men but only in 16.6% of women.Significance.Biological sex needs to be considered when EIT findings acquired in upright subjects in a rather caudal examination plane are interpreted. Sex differences in chest anatomy and thoracoabdominal mechanics may explain the results.


Subject(s)
Electric Impedance , Sex Characteristics , Thorax , Tomography , Humans , Male , Female , Tomography/methods , Middle Aged , Thorax/diagnostic imaging , Adult
8.
Magn Reson Imaging Clin N Am ; 32(3): 553-571, 2024 Aug.
Article in English | MEDLINE | ID: mdl-38944440

ABSTRACT

Anomalies of the fetal chest require advanced imaging with ultrasound and MR imaging as well as expertise on the part of the interpreting pediatric radiologist. Congenital diaphragmatic hernia and congenital lung malformation are the most frequently seen, and in both conditions, the radiologist should provide both detailed anatomic description and measurement data for prognostication. This article provides a detailed approach to imaging the anatomy, in-depth explanation of available measurements and prognostic value, and keys to identifying candidates for fetal intervention. Less common congenital lung tumors and mediastinal and chest wall masses are also reviewed.


Subject(s)
Magnetic Resonance Imaging , Humans , Magnetic Resonance Imaging/methods , Thorax/diagnostic imaging , Prenatal Diagnosis/methods , Female , Pregnancy , Thoracic Diseases/diagnostic imaging , Lung/diagnostic imaging , Lung/abnormalities
9.
Bioinspir Biomim ; 19(4)2024 Jun 28.
Article in English | MEDLINE | ID: mdl-38866024

ABSTRACT

The diversity in butterfly morphology has attracted many people around the world since ancient times. Despite morphological diversity, the wing and body kinematics of butterflies have several common features. In the present study, we constructed a bottom-up butterfly model, whose morphology and kinematics are simplified while preserving the important features of butterflies. The present bottom-up butterfly model is composed of two trapezoidal wings and a rod-shaped body with a thorax and abdomen. Its wings are flapped downward in the downstroke and backward in the upstroke by changing the geometric angle of attack (AOA). The geometric AOA is determined by the thorax-pitch and wing-pitch angles. The thorax-pitch angle is actively controlled by abdominal undulation, and the wing-pitch angle is passively determined because of a rotary spring representing the basalar and subalar muscles connecting the wings and thorax. We investigated the effectiveness of abdominal undulation for thorax-pitch control and how wing-pitch flexibility affects aerodynamic-force generation and thorax-pitch control, through numerical simulations using the immersed boundary-lattice Boltzmann method. As a result, the thorax-pitch angle perfectly follows the desired angle through abdominal undulation. In addition, there is an optimal wing-pitch flexibility that maximizes the flying speed in both the forward and upward directions, but the effect of wing-pitch flexibility on thorax-pitch control is not significant. Finally, we compared the flight behavior of the present bottom-up butterfly model with that of an actual butterfly. It was found that the present model does not reproduce reasonable body kinematics but can provide reasonable aerodynamics in butterfly flights.


Subject(s)
Butterflies , Computer Simulation , Flight, Animal , Models, Biological , Thorax , Wings, Animal , Wings, Animal/physiology , Wings, Animal/anatomy & histology , Animals , Butterflies/physiology , Butterflies/anatomy & histology , Flight, Animal/physiology , Thorax/physiology , Biomechanical Phenomena
10.
Rheumatol Int ; 44(8): 1481-1486, 2024 Aug.
Article in English | MEDLINE | ID: mdl-38914771

ABSTRACT

INTRODUCTION: Ankylosing spondylitis is chronic progressive disease, which decrease functions of musculoskeletal system including chest area. Those changes influences respiratory mechanics, worsen conditions of proper ventilation of lungs. OBJECTIVES: Rating of functional and respiratory parameters and dependence between them at patients with ankylosing spondylitis. MATERIALS & METHODS: The study included 45 patients with diagnosed ankylosing spondylitis. Chest and upper limbs mobility, resting spinal curvature alignment were assessed, and respiratory parameters were measured in a plethysmographic chamber JAGGER MasterScreen Body. RESULTS: Ankylosing spondylitis patients had lower respiratory parameters especially sReff, and FRC. Restriction of chest and upper limbs mobility was also demonstrated. Forward head extension was observed based on the occipital wall test. Correlations between functional parameters and correlations between functional and respiratory parameters were shown, in particular MIP, MEP, sReff, Rtot, TLC, ERV. CONCLUSIONS: The study confirmed a decrease in functional and respiratory parameters in the examined patients with ankylosing spondylitis compared to the applicable standards. A significant relationship was found between functional parameters in the upper body and respiratory parameters, which worsen with increasing thoracic dysfunction. The obtained results indicate the directions of therapy that should be taken into account to improve respiratory parameters and reduce respiratory dysfunction in these patients. Chest-focused physiotherapy appears to be an important element in improving function in patients with ankylosing spondylitis.


Subject(s)
Shoulder Joint , Spondylitis, Ankylosing , Humans , Spondylitis, Ankylosing/physiopathology , Male , Adult , Female , Middle Aged , Shoulder Joint/physiopathology , Spine/physiopathology , Spine/diagnostic imaging , Thorax/physiopathology , Thorax/diagnostic imaging , Range of Motion, Articular , Respiratory Mechanics/physiology , Respiratory Function Tests , Young Adult
11.
Sheng Wu Yi Xue Gong Cheng Xue Za Zhi ; 41(3): 439-446, 2024 Jun 25.
Article in Chinese | MEDLINE | ID: mdl-38932528

ABSTRACT

Electrical impedance tomography (EIT) is a non-radiation, non-invasive visual diagnostic technique. In order to improve the imaging resolution and the removing artifacts capability of the reconstruction algorithms for electrical impedance imaging in human-chest models, the HMANN algorithm was proposed using the Hadamard product to optimize multilayer artificial neural networks (MANN). The reconstructed images of the HMANN algorithm were compared with those of the generalized vector sampled pattern matching (GVSPM) algorithm, truncated singular value decomposition (TSVD) algorithm, backpropagation (BP) neural network algorithm, and traditional MANN algorithm. The simulation results showed that the correlation coefficient of the reconstructed images obtained by the HMANN algorithm was increased by 17.30% in the circular cross-section models compared with the MANN algorithm. It was increased by 13.98% in the lung cross-section models. In the lung cross-section models, some of the correlation coefficients obtained by the HMANN algorithm would decrease. Nevertheless, the HMANN algorithm retained the image information of the MANN algorithm in all models, and the HMANN algorithm had fewer artifacts in the reconstructed images. The distinguishability between the objects and the background was better compared with the traditional MANN algorithm. The algorithm could improve the correlation coefficient of the reconstructed images, and effectively remove the artifacts, which provides a new direction to effectively improve the quality of the reconstructed images for EIT.


Subject(s)
Algorithms , Electric Impedance , Image Processing, Computer-Assisted , Neural Networks, Computer , Thorax , Tomography , Humans , Tomography/methods , Thorax/diagnostic imaging , Image Processing, Computer-Assisted/methods , Lung/diagnostic imaging , Lung/physiology
12.
Sci Rep ; 14(1): 13897, 2024 06 17.
Article in English | MEDLINE | ID: mdl-38886358

ABSTRACT

Digital health technologies (DHTs) are increasingly being adopted in clinical trials, as they enable objective evaluations of health parameters in free-living environments. Although lumbar accelerometers notably provide reliable gait parameters, embedding accelerometers in chest devices, already used for vital signs monitoring, could capture a more comprehensive picture of participants' wellbeing, while reducing the burden of multiple devices. Here we assess the validity of gait parameters measured from a chest accelerometer. Twenty healthy adults (13 females, mean ± sd age: 33.9 ± 9.1 years) instrumented with lumbar and chest accelerometers underwent in-lab and outside-lab walking tasks, while monitored with reference devices (an instrumented mat, and a 6-accelerometers set). Gait parameters were extracted from chest and lumbar accelerometers using our open-source Scikit Digital Health gait (SKDH-gait) algorithm, and compared against reference values via Bland-Altman plots, Pearson's correlation, and intraclass correlation coefficient. Mixed effects regression models were performed to investigate the effect of device, task, and their interaction. Gait parameters derived from chest and lumbar accelerometers showed no significant difference and excellent agreement across all tasks, as well as good-to-excellent agreement and strong correlation against reference values, thus supporting the deployment of a single multimodal chest device in clinical trials, to simultaneously measure gait and vital signs.Trial Registration: The study was reviewed and approved by the Advarra IRB (protocol number: Pro00043100).


Subject(s)
Accelerometry , Gait , Thorax , Humans , Female , Male , Adult , Accelerometry/instrumentation , Accelerometry/methods , Gait/physiology , Healthy Volunteers , Walking/physiology , Wearable Electronic Devices , Algorithms , Young Adult
13.
Brachytherapy ; 23(4): 478-488, 2024.
Article in English | MEDLINE | ID: mdl-38811274

ABSTRACT

PURPOSE: To develop and validate risk models incorporating clinical and/or imaging parameters based on three-dimensional treatment-planning systems (3D-TPS) to predict the occurrence of 125I seed migration and the number of migrated seeds <2/≥2 to the chest after brachytherapy for patients with malignant hepatic tumors. METHODS AND MATERIALS: A total of 480 patients diagnosed with malignant liver tumors receiving 125I seed brachytherapy from July 2010 to May 2020 were retrospectively enrolled. Variables included 3D-TPS-based CT parameters, that is, the distance from the seed to the inferior vena cava (DSI), the distance from the seed to the second hepatic portal (DSP) and the angle from the seed to the second hepatic portal (ASP), and patients' clinical characteristics, that is, the number of seed implantation procedures (NSP), the maximum number of implanted seeds one time (MAX) and laboratory parameters within 1 week before treatment. Two sets of logistic regression models incorporating clinical and/or imaging variables were developed to predict the occurrence of seed migration and the number of migrated seeds <2/≥2. Model performance was assessed by ROC analysis and decision curve analysis. RESULTS: Compared with the clinical models, the combined model showed a higher discriminative ability for both the prediction of migration occurrence and number of migrated seeds ≥ 2/<2 to the chest (AUC, 0.879 vs. 0.668, p < 0.05; 0.895 vs. 0.701, p < 0.05). The decision curve analysis results indicated higher net benefits of combined models than clinical models. Variables, including DSI, NSP and pretreatment lymphocyte-to-neutrophil ratio, acted as the most important predictors in combined models. CONCLUSIONS: The proposed combined models based on 3D-TPS improved discriminative abilities for predicting 125I seed migration and number of migrated seeds <2/≥2 to the chest after hepatic brachytherapy, being promising to aid clinical decision-making.


Subject(s)
Brachytherapy , Iodine Radioisotopes , Liver Neoplasms , Humans , Brachytherapy/adverse effects , Iodine Radioisotopes/therapeutic use , Female , Male , Liver Neoplasms/radiotherapy , Liver Neoplasms/diagnostic imaging , Middle Aged , Retrospective Studies , Aged , Radiotherapy Planning, Computer-Assisted/methods , Foreign-Body Migration/diagnostic imaging , Tomography, X-Ray Computed , Imaging, Three-Dimensional , Adult , Thorax/diagnostic imaging , Thorax/radiation effects , Aged, 80 and over
14.
F1000Res ; 13: 274, 2024.
Article in English | MEDLINE | ID: mdl-38725640

ABSTRACT

Background: The most recent advances in Computed Tomography (CT) image reconstruction technology are Deep learning image reconstruction (DLIR) algorithms. Due to drawbacks in Iterative reconstruction (IR) techniques such as negative image texture and nonlinear spatial resolutions, DLIRs are gradually replacing them. However, the potential use of DLIR in Head and Chest CT has to be examined further. Hence, the purpose of the study is to review the influence of DLIR on Radiation dose (RD), Image noise (IN), and outcomes of the studies compared with IR and FBP in Head and Chest CT examinations. Methods: We performed a detailed search in PubMed, Scopus, Web of Science, Cochrane Library, and Embase to find the articles reported using DLIR for Head and Chest CT examinations between 2017 to 2023. Data were retrieved from the short-listed studies using Preferred Reporting Items for Systematic Reviews and Meta-analysis (PRISMA) guidelines. Results: Out of 196 articles searched, 15 articles were included. A total of 1292 sample size was included. 14 articles were rated as high and 1 article as moderate quality. All studies compared DLIR to IR techniques. 5 studies compared DLIR with IR and FBP. The review showed that DLIR improved IQ, and reduced RD and IN for CT Head and Chest examinations. Conclusions: DLIR algorithm have demonstrated a noted enhancement in IQ with reduced IN for CT Head and Chest examinations at lower dose compared with IR and FBP. DLIR showed potential for enhancing patient care by reducing radiation risks and increasing diagnostic accuracy.


Subject(s)
Algorithms , Deep Learning , Head , Radiation Dosage , Tomography, X-Ray Computed , Humans , Tomography, X-Ray Computed/methods , Head/diagnostic imaging , Image Processing, Computer-Assisted/methods , Thorax/diagnostic imaging , Radiography, Thoracic/methods , Signal-To-Noise Ratio
15.
J Morphol ; 285(6): e21712, 2024 Jun.
Article in English | MEDLINE | ID: mdl-38798246

ABSTRACT

Although the monophyly of Paraneoptera (=hemipteroid orders or Acercaria, composed of Psocodea, Thysanoptera and Hemiptera) has been widely accepted morphologically, the results from molecular phylogenetic and phylogenomic analyses contradict this hypothesis. In particular, phylogenomic analyses provide strong bootstrap support for the sister group relationship between Psocodea and Holometabola, that is, paraphyly of Paraneoptera. Here, we examined the pterothoracic musculature of Paraneoptera, as well as a wide range of other neopterous insect orders, and analysed its phylogenetic implication. By using the synchrotron microcomputed tomography (µCT) and parsimony-based ancestral state reconstruction, several apomorphic conditions suggesting the monophyly of Paraneoptera, such as the absence of the II/IIItpm7, IIscm3, IIIspm2 and IIIscm3 muscles, were identified. In contrast, no characters supporting Psocodea + Holometabola were recovered from the thoracic muscles. These results provide additional support for the monophyly of Paraneoptera, together with the previously detected morphological apomorphies of the head, wing base, and abdomen.


Subject(s)
Neoptera , Phylogeny , X-Ray Microtomography , Animals , Neoptera/anatomy & histology , Neoptera/genetics , Neoptera/classification , Muscles/anatomy & histology , Thorax/anatomy & histology
16.
J Bodyw Mov Ther ; 38: 18-23, 2024 Apr.
Article in English | MEDLINE | ID: mdl-38763560

ABSTRACT

BACKGROUND: Poor posture and sedentary lifestyle cause Forward Head Posture (FHP). To correct this, a Posture Correction Band (PCB) is commonly used. However, the efficacy of PCB vs. McKenzie's Exercises on pulmonary function and chest expansion in asymptomatic individuals with FHP was not known. OBJECTIVE: This study aimed to determine the efficacy of PCB vs. McKenzie's Exercises on the Pulmonary function and chest expansion in asymptomatic population with FHP. METHODOLOGY: A Randomized control trial was conducted on forty-two subjects with FHP. Subjects were divided in two groups. G1 group was educated as per McKenzie's exercises to perform once daily for a month. The Pulmonary function test and chest expansion of this group was performed before and after the McKenzie exercises. G2 group wore PCB for 2 h daily for a month and their PFT and chest expansion was recorded before and after the trial. FVC, FEV1, FEV1/FVC ratio, PEFR and Chest expansion were measured. RESULTS: The P-value of FVC, FEV1, FEV1/FVC ratio and PEFR between the groups (treatment group) was significant as 0.000, 0.000, 0.000 and 0.02 respectively. The chest expansion was non-significant between the groups (treatment group) with P-value as 0.553, 0.493 and 0.699 at axillary, 4th intercostal and xiphisternum level respectively. The P-value of FVC, FEV1, FEV1/FVC ratio and PEFR between the groups (control group) was non-significant as 0.682, 0.149, 0.424 and 0.414 respectively. The chest expansion was also non-significant between the groups (control group) with P-value as 0.853, 0.651 and 0.763 at axillary, 4th intercostal and xiphisternum level. CONCLUSION: The study concluded that there were significant effects of both Posture Correction Band and Mc'Kenzie exercises on pulmonary function with greater difference seen with PCB and non-significant effects on chest expansion in terms of P-values in treatment group.


Subject(s)
Posture , Respiratory Function Tests , Humans , Posture/physiology , Male , Female , Adult , Respiratory Function Tests/methods , Exercise Therapy/methods , Thorax/physiology , Lung/physiology , Head/physiology , Young Adult , Middle Aged
17.
J Appl Clin Med Phys ; 25(7): e14389, 2024 Jul.
Article in English | MEDLINE | ID: mdl-38778565

ABSTRACT

PURPOSE: The aim of this study was to compare the organ doses assessed through a digital phantom-based and a patient specific-based dosimetric tool in adult routine thorax computed tomography (CT) examinations with reference to physical dose measurements performed in anthropomorphic phantoms. METHODS: Two Monte Carlo based dose calculation tools were used to assess organ doses in routine adult thorax CT examinations. These were a digital phantom-based dosimetry tool (NCICT, National Cancer Institute, USA) and a patient-specific individualized dosimetry tool (ImpactMC, CT Imaging GmbH, Germany). Digital phantoms and patients were classified in four groups according to their water equivalent diameter (Dw). Normalized to volume computed tomography dose index (CTDIvol), organ dose was assessed for lungs, esophagus, heart, breast, active bone marrow, and skin. Organ doses were compared to measurements performed using thermoluminescent detectors (TLDs) in two physical anthropomorphic phantoms that simulate the average adult individual as a male (Alderson Research Labs, USA) and as a female (ATOM Phantoms, USA). RESULTS: The average percent difference of NCICT to TLD and ImpactMC to TLD dose measurements across all organs in both sexes was 13% and 6%, respectively. The average ± 1 standard deviation in dose values across all organs with NCICT, ImpactMC, and TLDs was ± 0.06 (mGy/mGy), ± 0.19 (mGy/mGy), and ± 0.13 (mGy/mGy), respectively. Organ doses decreased with increasing Dw in both NCICT and ImpactMC. CONCLUSION: Organ doses estimated with ImpactMC were in closer agreement to TLDs compared to NCICT. This may be attributed to the inherent property of ImpactMC methodology to generate phantoms that resemble the realistic anatomy of the examined patient as opposed to NCICT methodology that incorporates an anatomical discrepancy between phantoms and patients.


Subject(s)
Monte Carlo Method , Organs at Risk , Phantoms, Imaging , Radiation Dosage , Radiography, Thoracic , Tomography, X-Ray Computed , Humans , Tomography, X-Ray Computed/methods , Male , Female , Adult , Organs at Risk/radiation effects , Radiography, Thoracic/methods , Radiometry/methods , Thorax/diagnostic imaging , Thorax/radiation effects , Image Processing, Computer-Assisted/methods , Radiotherapy Planning, Computer-Assisted/methods
18.
Appl Ergon ; 119: 104311, 2024 Sep.
Article in English | MEDLINE | ID: mdl-38763088

ABSTRACT

To optimise soldier protection within body armour systems, knowledge of the boundaries of essential thoraco-abdominal organs is necessary to inform coverage requirements. However, existing methods of organ boundary identification are costly and time consuming, limiting widespread adoption for use on soldier populations. The aim of this study was to evaluate a novel method of using 3D organ models to identify essential organ boundaries from low dose planar X-rays and 3D external surface scans of the human torso. The results revealed that, while possible to reconstruct 3D organs using template 3D organ models placed over X-ray images, the boundary data (relating to the size and position of each organ) obtained from the reconstructed organs differed significantly from MRI organ data. The magnitude of difference varied between organs. The most accurate anatomical boundaries were the left, right, and inferior boundaries of the heart, and lateral boundaries for the liver and spleen. Visual inspection of the data demonstrated that 11 of 18 organ models were successfully integrated within the 3D space of the participant's surface scan. These results suggest that, if this method is further refined and evaluated, it has potential to be used as a tool for estimating body armour coverage requirements.


Subject(s)
Abdomen , Anthropometry , Imaging, Three-Dimensional , Liver , Magnetic Resonance Imaging , Humans , Anthropometry/methods , Male , Liver/diagnostic imaging , Liver/anatomy & histology , Adult , Abdomen/diagnostic imaging , Abdomen/anatomy & histology , Thorax/diagnostic imaging , Thorax/anatomy & histology , Spleen/diagnostic imaging , Spleen/anatomy & histology , Protective Clothing , Torso/diagnostic imaging , Military Personnel , Heart/diagnostic imaging , Heart/anatomy & histology , Young Adult , Female
19.
Radiat Prot Dosimetry ; 200(8): 802-807, 2024 Jun 03.
Article in English | MEDLINE | ID: mdl-38773775

ABSTRACT

Interventional cardiology is characterized by high radiation exposure for both the patient and the operator. Adequate shielding and monitoring of the operator are fundamental to comply with radiation protection principles. In a previous work, the effect on the dose of the dosemeter position on the chest was studied. In this paper, the investigation has been completed, employing an anthropomorphic thorax phantom, equipped with arms. Although there are differences between the Monte Carlo simulations and the measurements, similar trends are observed, showing that the reduction in dose, due to the arms, is between 20 and 60%, compared with the situation without arms. For that reason, considering a dosemeter placed on the chest, the upper position, which is the least affected by the arms, should be preferred while the extreme lateral position, near the armpit, should be avoided.


Subject(s)
Computer Simulation , Monte Carlo Method , Occupational Exposure , Phantoms, Imaging , Protective Clothing , Radiation Dosage , Radiation Monitoring , Radiation Protection , Humans , Occupational Exposure/analysis , Occupational Exposure/prevention & control , Radiation Protection/methods , Radiation Monitoring/methods , Cardiology/methods , Medical Staff , Thorax/radiation effects
20.
J Cardiothorac Surg ; 19(1): 166, 2024 Apr 01.
Article in English | MEDLINE | ID: mdl-38561747

ABSTRACT

BACKGROUND: Rosai-Dorfman Disease (RDD) is a rare self-limiting histiocytosis, more prevalent in children and young adults. It typically manifests as painless bilateral massive cervical lymphadenopathy but may also extend to extra-nodal sites, with intrathoracic RDD noted in 2% of cases. Distinguishing mediastinal RDD from thymoma on imaging poses challenges, underscoring the reliance on pathological features and immunohistochemical staining for diagnosis. CASE PRESENTATION: Patient, male, 33 years old, underwent lung a CT revealing an enlarged round soft tissue shadow in the anterior superior mediastinum, compared to a year ago. Surgical resection removed the entire mass, thymus, and part of the pericardium, confirming RDD on pathology. Genetic testing using second-generation testing technology identified a KRAS gene point mutation. CONCLUSIONS: No established treatment protocol currently exists for this disease. However, as genetic mutation research progresses, a novel therapeutic avenue is emerging: targeted therapy integrated with surgical interventions.


Subject(s)
Histiocytosis, Sinus , Adult , Humans , Male , Histiocytosis, Sinus/diagnosis , Histiocytosis, Sinus/genetics , Histiocytosis, Sinus/surgery , Mediastinum/pathology , Mutation , Proto-Oncogene Proteins p21(ras)/genetics , Proto-Oncogene Proteins p21(ras)/therapeutic use , Thorax/pathology
SELECTION OF CITATIONS
SEARCH DETAIL