Your browser doesn't support javascript.
loading
: 20 | 50 | 100
1 - 20 de 12.452
1.
Sci Rep ; 14(1): 10597, 2024 05 08.
Article En | MEDLINE | ID: mdl-38719924

Parotid lumps are a heterogeneous group of mainly benign but also malignant tumors. Preoperative imaging does not allow a differentiation between tumor types. Multispectral optoacoustic tomography (MSOT) may improve the preoperative diagnostics. In this first prospective pilot trial the ability of MSOT to discriminate between the two most frequent benign parotid tumors, pleomorphic adenoma (PA) and Warthin tumor (WT) as well as to normal parotid tissue was explored. Six wavelengths (700, 730, 760, 800, 850, 900 nm) and the parameters deoxygenated (HbR), oxygenated (HbO2), total hemoglobin (HbT), and saturation of hemoglobin (sO2) were analyzed. Ten patients with PA and fourteen with WT were included (12/12 female/male; median age: 51 years). For PA, the mean values for all measured wave lengths as well as for the hemoglobin parameters were different for the tumors compared to the healthy parotid (all p < 0.05). The mean MSOT parameters were all significantly higher (all p < 0.05) in the WT compared to healthy parotid gland except for HbT and sO2. Comparing both tumors directly, the mean values of MSOT parameters were not different between PA and WT (all p > 0.05). Differences were seen for the maximal MSOT parameters. The maximal tumor values for 900 nm, HbR, HbT, and sO2 were lower in PA than in WT (all p < 0.05). This preliminary MSOT parotid tumor imaging study showed clear differences for PA or WT compared to healthy parotid tissue. Some MSOT characteristics of PA and WT were different but needed to be explored in larger studies.


Parotid Neoplasms , Photoacoustic Techniques , Humans , Female , Parotid Neoplasms/diagnostic imaging , Parotid Neoplasms/pathology , Middle Aged , Male , Pilot Projects , Prospective Studies , Photoacoustic Techniques/methods , Adult , Aged , Hemoglobins/analysis , Hemoglobins/metabolism , Adenolymphoma/diagnostic imaging , Adenolymphoma/pathology , Adenoma, Pleomorphic/diagnostic imaging , Adenoma, Pleomorphic/pathology , Tomography/methods , Parotid Gland/diagnostic imaging , Parotid Gland/pathology
2.
Methods Cell Biol ; 187: 139-174, 2024.
Article En | MEDLINE | ID: mdl-38705623

Array tomography (AT) allows one to localize sub-cellular components within the structural context of cells in 3D through the imaging of serial sections. Using this technique, the z-resolution can be improved physically by cutting ultra-thin sections. Nevertheless, conventional immunofluorescence staining of those sections is time consuming and requires relatively large amounts of costly antibody solutions. Moreover, epitopes are only readily accessible at the section's surface, leaving the volume of the serial sections unlabeled. Localization of receptors at neuronal synapses in 3D in their native cellular ultrastructural context is important for understanding signaling processes. Here, we present in vivo labeling of receptors via fluorophore-coupled tags in combination with super-resolution AT. We present two workflows where we label receptors at the plasma membrane: first, in vivo labeling via microinjection with a setup consisting of readily available components and self-manufactured microscope table equipment and second, live receptor labeling by using a cell-permeable tag. To take advantage of a near-to-native preservation of tissues for subsequent scanning electron microscopy (SEM), we also apply high-pressure freezing and freeze substitution. The advantages and disadvantages of our workflows are discussed.


Synapses , Tomography , Animals , Synapses/metabolism , Synapses/ultrastructure , Tomography/methods , Imaging, Three-Dimensional/methods , Staining and Labeling/methods , Mice , Microscopy, Electron, Scanning/methods , Fluorescent Dyes/chemistry , Microinjections/methods , Neurons/metabolism , Rats
4.
Biosensors (Basel) ; 14(5)2024 Apr 26.
Article En | MEDLINE | ID: mdl-38785690

Magnetic Induction Tomography (MIT) is a non-invasive imaging technique used for dynamic monitoring and early screening of cerebral hemorrhage. Currently, there is a significant challenge in cerebral hemorrhage MIT due to weak detection signals, which seriously affects the accuracy of the detection results. To address this issue, a dual-plane enhanced coil was proposed by combining the target field method with consideration of the spatial magnetic field attenuation pattern within the imaging target region. Simulated detection models were constructed using the proposed coil and cylindrical coil as excitation coils, respectively, and simulation imaging tests were conducted using the detection results. The simulation results indicate that compared to the cylindrical coil, the proposed coil enhances the linearity of the magnetic field within the imaging target region by 60.43%. Additionally, it effectively enhances the detection voltage and phase values. The simulation results of hemorrhage detection show that the proposed coil improves the accuracy of hemorrhage detection by 18.26%. It provides more precise detection results, offering a more reliable solution for cerebral hemorrhage localization and detection.


Cerebral Hemorrhage , Cerebral Hemorrhage/diagnostic imaging , Humans , Tomography , Computer Simulation
5.
Physiol Meas ; 45(5)2024 May 21.
Article En | MEDLINE | ID: mdl-38697210

Objective.Electrical impedance tomography (EIT) produces clinical useful visualization of the distribution of ventilation inside the lungs. The accuracy of EIT-derived parameters can be compromised by the cardiovascular signal. Removal of these artefacts is challenging due to spectral overlapping of the ventilatory and cardiovascular signal components and their time-varying frequencies. We designed and evaluated advanced filtering techniques and hypothesized that these would outperform traditional low-pass filters.Approach.Three filter techniques were developed and compared against traditional low-pass filtering: multiple digital notch filtering (MDN), empirical mode decomposition (EMD) and the maximal overlap discrete wavelet transform (MODWT). The performance of the filtering techniques was evaluated (1) in the time domain (2) in the frequency domain (3) by visual inspection. We evaluated the performance using simulated contaminated EIT data and data from 15 adult and neonatal intensive care unit patients.Main result.Each filter technique exhibited varying degrees of effectiveness and limitations. Quality measures in the time domain showed the best performance for MDN filtering. The signal to noise ratio was best for DLP, but at the cost of a high relative and removal error. MDN outbalanced the performance resulting in a good SNR with a low relative and removal error. MDN, EMD and MODWT performed similar in the frequency domain and were successful in removing the high frequency components of the data.Significance.Advanced filtering techniques have benefits compared to traditional filters but are not always better. MDN filtering outperformed EMD and MODWT regarding quality measures in the time domain. This study emphasizes the need for careful consideration when choosing a filtering approach, depending on the dataset and the clinical/research question.


Artifacts , Electric Impedance , Signal Processing, Computer-Assisted , Tomography , Humans , Tomography/methods , Signal-To-Noise Ratio , Adult , Wavelet Analysis , Cardiovascular System , Infant, Newborn
6.
J Contam Hydrol ; 264: 104368, 2024 May.
Article En | MEDLINE | ID: mdl-38776561

In this study, twenty-two water samples were collected from boreholes (BH), and streams to evaluate drinking water quality, its distribution, identification of contamination sources and apportionment for Moti village, northern Pakistan. An atomic absorption spectrophotometer (AAS) is utilized to determine the level of heavy metals in water such as arsenic (As), zinc (Zn), lead (Pb), copper (Cu), cadmium (Cd), manganese (Mn), and ferrous (Fe). Groundwater chemistry and its quantitative driving factors were further explored using multivariate statistical methods, Principal Component Analysis (PCA) and Positive Matrix Factorization (PMF) models. Finally, a total of eight electrical resistivity tomographs (ERTs) were acquired across i) the highly contaminated streams; ii) the villages far away from contaminated streams; and iii) across the freshwater stream. In the Moti village, the mean levels (mg/l) of heavy metals in water samples were 7.2465 (As), 0.4971 (Zn), 0.5056 (Pb), 0.0422 (Cu), 0.0279 (Cd), 0.1579 (Mn), and 0.9253 (Fe) that exceeded the permissible limit for drinking water (such as 0.010 for As and Pb, 3.0 for Zn, 0.003 for Cd and 0.3 for Fe) established by the World Health Organization (WHO, 2008). The average entropy weighted water quality index (EWQI) of 200, heavy metal pollution index (HPI) of 175, heavy metal evaluation index (HEI) of 1.6 values reveal inferior water quality in the study area. Human health risk assessment, consisting of hazard quotient (HQ) and hazard index (HI), exceeded the risk threshold (>1),indicating prevention of groundwater usage. Results obtained from the PCA and PMF models indicated anthropogenic sources (i.e. industrial and solid waste) responsible for the high concentration of heavy metals in the surface and groundwater. The ERTs imaged the subsurface down to about 40 m depths and show the least resistivity values (<11 Ωm) for subsurface layers that are highly contaminated. However, the ERTs revealed relatively high resistivity values for subsurface layers containing fresh or less contaminated water. Filtering and continuous monitoring of the quality of drinking water in the village are highly recommended.


Environmental Monitoring , Groundwater , Metals, Heavy , Water Pollutants, Chemical , Water Quality , Pakistan , Metals, Heavy/analysis , Water Pollutants, Chemical/analysis , Environmental Monitoring/methods , Groundwater/chemistry , Groundwater/analysis , Entropy , Tomography/methods , Principal Component Analysis , Drinking Water/chemistry , Drinking Water/analysis
7.
PLoS One ; 19(5): e0302476, 2024.
Article En | MEDLINE | ID: mdl-38709742

BACKGROUND: The Incentive Spirometer (IS) increases lung volume and improves gas exchange by visually stimulating patients to take slow, deep breaths. It prevents respiratory complications and treats postoperative atelectasis in patients undergoing abdominal, thoracic, and neurosurgical procedures. Its effectiveness has been validated in studies that support improved lung capacities and volumes in individuals with respiratory complications, postoperative thoracic surgery, upper abdominal surgery, and bariatric surgery. The modified Pachón incentive spirometer (MPIS) is a cost-effective alternative to branded IS. It is crucial to validate whether the MPIS distributes ventilation as effectively as commercial devices do. Ventilation distribution will be measured using electrical impedance tomography. OBJECTIVE: The aim is to compare the distribution of pulmonary ventilation between the MPIS and another commercial IS in healthy adults using electrical impedance tomography. METHODS: A crossover clinical trial is proposed to evaluate the measurement of pulmonary ventilation distribution using EIT in a sample of healthy adults. All participants will use a commercial flow IS and the MPIS, with the order of assignment randomized. This research will use electrical impedance tomography to validate the operation of the MPIS. CONCLUSIONS: This study protocol will compare two incentive spirometers' impact on pulmonary ventilation, potentially endorsing the adoption of a cost-effective device to enhance accessibility for targeted populations. TRIAL REGISTRATION: The study was registered in ClinicalTrials.gov (NTC05532748).


Electric Impedance , Pulmonary Ventilation , Spirometry , Tomography , Humans , Adult , Spirometry/methods , Spirometry/instrumentation , Tomography/methods , Pulmonary Ventilation/physiology , Male , Female , Healthy Volunteers , Cross-Over Studies , Lung/physiology , Middle Aged , Young Adult
8.
Physiol Meas ; 45(6)2024 Jun 05.
Article En | MEDLINE | ID: mdl-38772395

Objective.Noisy measurements frequently cause noisy and inaccurate images in impedance imaging. No post-processing technique exists to calculate the propagation of measurement noise and use this to suppress noise in the image. The objectives of this work were (1) to develop a post-processing method for noise-based correction (NBC) in impedance tomography, (2) to test whether NBC improves image quality in electrical impedance tomography (EIT), (3) to determine whether it is preferable to use correlated or uncorrelated noise for NBC, (4) to test whether NBC works within vivodata and (5) to test whether NBC is stable across model and perturbation geometries.Approach.EIT was performedin silicoin a 2D homogeneous circular domain and an anatomically realistic, heterogeneous 3D human head domain for four perturbations and 25 noise levels in each case. This was validated by performing EIT for four perturbations in a circular, saline tank in 2D as well as a human head-shaped saline tank with a realistic skull-like layer in 3D. Images were assessed on the error in the weighted spatial variance (WSV) with respect to the true, target image. The effect of NBC was also tested forin vivoEIT data of lung ventilation in a human thorax and cortical activity in a rat brain.Main results.On visual inspection, NBC maintained or increased image quality for all perturbations and noise levels in 2D and 3D, both experimentally andin silico. Analysis of the WSV showed that NBC significantly improved the WSV in nearly all cases. When the WSV was inferior with NBC, this was either visually imperceptible or a transformation between noisy reconstructions. Forin vivodata, NBC improved image quality in all cases and preserved the expected shape of the reconstructed perturbation.Significance.In practice, uncorrelated NBC performed better than correlated NBC and is recommended as a general-use post-processing technique in EIT.


Electric Impedance , Signal-To-Noise Ratio , Tomography , Tomography/methods , Humans , Animals , Rats , Image Processing, Computer-Assisted/methods , Head/diagnostic imaging
9.
Nat Commun ; 15(1): 4228, 2024 May 18.
Article En | MEDLINE | ID: mdl-38762498

Cross-modal analysis of the same whole brain is an ideal strategy to uncover brain function and dysfunction. However, it remains challenging due to the slow speed and destructiveness of traditional whole-brain optical imaging techniques. Here we develop a new platform, termed Photoacoustic Tomography with Temporal Encoding Reconstruction (PATTERN), for non-destructive, high-speed, 3D imaging of ex vivo rodent, ferret, and non-human primate brains. Using an optimally designed image acquisition scheme and an accompanying machine-learning algorithm, PATTERN extracts signals of genetically-encoded probes from photobleaching-based temporal modulation and enables reliable visualization of neural projection in the whole central nervous system with 3D isotropic resolution. Without structural and biological perturbation to the sample, PATTERN can be combined with other whole-brain imaging modalities to acquire the whole-brain image with both high resolution and morphological fidelity. Furthermore, cross-modal transcriptome analysis of an individual brain is achieved by PATTERN imaging. Together, PATTERN provides a compatible and versatile strategy for brain-wide cross-modal analysis at the individual level.


Brain , Ferrets , Imaging, Three-Dimensional , Photoacoustic Techniques , Animals , Brain/diagnostic imaging , Photoacoustic Techniques/methods , Imaging, Three-Dimensional/methods , Mice , Algorithms , Machine Learning , Tomography/methods , Image Processing, Computer-Assisted/methods , Rats , Male
10.
J Gastrointest Surg ; 28(4): 375-380, 2024 Apr.
Article En | MEDLINE | ID: mdl-38583886

PURPOSE: This study aimed to investigate the correlation between sarcopenia and adverse events (AEs) of postoperative imatinib therapy through computed tomography (CT) quantitative body composition for intermediate- and high-risk gastrointestinal stromal tumors (GISTs). METHODS: The study retrospectively analyzed the clinical data of 208 patients with intermediate- and high-risk GIST treated surgically and treated with imatinib afterward at the First Affiliated Hospital of Wenzhou Medical University between October 2011 and October 2021. Images of preoperative CT scans within 1 month were used to determine the body composition of the patients. On the basis of the L3 skeletal muscle index, patients were classified into sarcopenia and nonsarcopenia groups. In 2 groups, AEs related to imatinib were analyzed. RESULTS: The proportion of AEs related to imatinib in the sarcopenia group was higher, and this disparity had a significant statistical significance (P = .013). Sarcopenia was significantly associated with hemoglobin reduction compared with nonsarcopenia (P = .015). There was a significant difference between the sarcopenia group and the nonsarcopenia group in the ratio of severe AEs (grades 3-4). Hemoglobin content (odds ratio [OR], 0.981; 95% CI, 0.963-1.000; P = .045), sex (OR, 0.416; 95% CI, 0.192-0.904; P = .027), and sarcopenia (OR, 5.631; 95% CI, 2.262-14.014; P < .001) were the influential factors of imatinib severe AEs in patients with intermediate- and high-risk GIST within 1 year after imatinib treatment. CONCLUSION: Patients with preoperative sarcopenia have a higher incidence and severity of AEs during adjuvant imatinib therapy.


Antineoplastic Agents , Gastrointestinal Stromal Tumors , Sarcopenia , Humans , Imatinib Mesylate/adverse effects , Gastrointestinal Stromal Tumors/diagnostic imaging , Gastrointestinal Stromal Tumors/drug therapy , Gastrointestinal Stromal Tumors/surgery , Retrospective Studies , Sarcopenia/chemically induced , Sarcopenia/diagnostic imaging , Chemotherapy, Adjuvant , Hemoglobins , Tomography , Antineoplastic Agents/adverse effects
11.
Urolithiasis ; 52(1): 65, 2024 Apr 17.
Article En | MEDLINE | ID: mdl-38630281

Extracorporeal shock wave lithotripsy (ESWL) is a safe and efficient treatment option for urinary stone disease. The overall stone-free rate (SFR) varies significantly. This study aimed to assess the influence of stone size, location, stone density, and skin-to-stone distance (SSD), on the outcome of ESWL. We assessed whether pre-treatment non-contrast-enhanced CT scan (NCCT) confers significant advantages compared to kidney-ureter-bladder film (KUB) only. We reviewed the medical records of 307 cases (165 men, 142 women) with renal and ureteral stones treated consecutively at our institution with ESWL between 2020 and 2023. 44 of these underwent a NCCT. The outcome of ESWL was defined in two ways: visible stone fragmentation on KUB, and the need for further treatment. Overall success of fragmentation was 85% (261 patients). 61% of patients (n = 184) didn't need any further treatment. Stone size and location correlated significantly with treatment outcomes regarding the need for further treatment (p = 0.004) and stone fragmentation (p = 0.016), respectively. Unlike mean SSD (p = 0.462), the mean attenuation value (MAV) significantly correlated with the need for retreatment (p = 0.016). MAV seems to be a better predictor of treatment success (AUC of the ROC curve: 0.729), compared to stone size (AUC: 0.613). The difference between groups (with and without NCCT) in both treatment outcomes did not reach statistical significance. During decision-making, information regarding SSD and MAV can be useful in more dubious scenarios. However, it appears that their inclusion doesn't provide substantial advantages when compared to relying solely on KUB.


Lithotripsy , Ureteral Calculi , Male , Humans , Female , Retrospective Studies , Ureteral Calculi/diagnostic imaging , Ureteral Calculi/therapy , Kidney , Computers , Tomography
12.
Physiol Meas ; 45(4)2024 Apr 18.
Article En | MEDLINE | ID: mdl-38565126

Objective.The objective of this study was to propose a novel data-driven method for solving ill-posed inverse problems, particularly in certain conditions such as time-difference electrical impedance tomography for detecting the location and size of bubbles inside a pipe.Approach.We introduced a new layer architecture composed of three paths: spatial, spectral, and truncated spectral paths. The spatial path processes information locally, whereas the spectral and truncated spectral paths provide the network with a global receptive field. This unique architecture helps eliminate the ill-posedness and nonlinearity inherent in the inverse problem. The three paths were designed to be interconnected, allowing for an exchange of information on different receptive fields with varied learning abilities. Our network has a bottleneck architecture that enables it to recover signal information from noisy redundant measurements. We named our proposed model truncated spatial-spectral convolutional neural network (TSS-ConvNet).Main results.Our model demonstrated superior accuracy with relatively high resolution on both simulation and experimental data. This indicates that our approach offers significant potential for addressing ill-posed inverse problems in complex conditions effectively and accurately.Significance.The TSS-ConvNet overcomes the receptive field limitation found in most existing models that only utilize local information in Euclidean space. We trained the network on a large dataset covering various configurations with random parameters to ensure generalization over the training samples.


Tomography, X-Ray Computed , Tomography , Tomography/methods , Electric Impedance , Neural Networks, Computer , Image Processing, Computer-Assisted/methods
13.
Physiol Meas ; 45(4)2024 Apr 16.
Article En | MEDLINE | ID: mdl-38624240

Objective.Electrical impedance tomography (EIT) is a noninvasive imaging method whereby electrical measurements on the periphery of a heterogeneous conductor are inverted to map its internal conductivity. The EIT method proposed here aims to improve computational speed and noise tolerance by introducing sensitivity volume as a figure-of-merit for comparing EIT measurement protocols.Approach.Each measurement is shown to correspond to a sensitivity vector in model space, such that the set of measurements, in turn, corresponds to a set of vectors that subtend a sensitivity volume in model space. A maximal sensitivity volume identifies the measurement protocol with the greatest sensitivity and greatest mutual orthogonality. A distinguishability criterion is generalized to quantify the increased noise tolerance of high sensitivity measurements.Main result.The sensitivity volume method allows the model space dimension to be minimized to match that of the data space, and the data importance to be increased within an expanded space of measurements defined by an increased number of contacts.Significance.The reduction in model space dimension is shown to increasecomputational efficiency, accelerating tomographic inversion by several orders of magnitude, while the enhanced sensitivitytolerates higher noiselevels up to several orders of magnitude larger than standard methods.


Algorithms , Tomography, X-Ray Computed , Electric Impedance , Tomography/methods , Electric Conductivity
14.
Zhonghua Yi Xue Za Zhi ; 104(15): 1247-1252, 2024 Apr 16.
Article Zh | MEDLINE | ID: mdl-38637164

Acute respiratory distress syndrome (ARDS) is a common and critical clinical condition characterized by diffuse damage to the lung interstitium, alveoli, and increased permeability of pulmonary blood vessels. CT can be used to assess the imaging features, severity, and prediction of ARDS, but it requires patient transportation to the CT room and is only a static examination. Electrical impedance tomography (EIT) is an increasingly widely used monitoring tool in clinical applications in recent years. It enables continuous real-time assessment of lung ventilation distribution at the bedside and has high clinical value in optimizing mechanical ventilation parameters for critically ill patients. This article introduces the basic principles of EIT and how to better utilize EIT technology to guide mechanical ventilation treatment for ARDS patients.


Respiration, Artificial , Respiratory Distress Syndrome , Humans , Respiration, Artificial/methods , Electric Impedance , Tomography/methods , Respiratory Distress Syndrome/therapy , Tomography, X-Ray Computed/methods , Lung
15.
Gen Dent ; 72(3): 50-55, 2024.
Article En | MEDLINE | ID: mdl-38640006

The objective of this retrospective study was to assess the bone quality of healing mandibular fracture sites by measuring the Hounsfield units (HU) on computed tomographic (CT) images obtained presurgery and postsurgery in patients treated with rigid internal fixation (RIF). The HU values of healing fracture sites were compared to those of corresponding nonfractured (control) sites on the opposing side and cervical vertebrae sites in the same patients. In total, 31 patients with 45 mandibular fractures treated with RIF underwent presurgical and postsurgical CT examinations. The scans performed after surgery (1, 3, 6, 12, or 18 months) were taken only when there was a need for radiographic evaluation due to a complaint of discomfort from the patient or when the surgeon needed to verify the postsurgical outcome, and each patient underwent only a single postsurgical CT. At the presurgical CT examination, the HU values were lower in the fracture sites than in the control sites. At 3 months postsurgery, the HU values in the fracture sites had increased as the mandibular bone healed. At 6 months postsurgery, the HU values in the fracture sites were higher than those of the control sites. At 12 and 18 months postsurgery, the HU values of both sites were similar. The HU values of the cervical vertebrae remained constant with time. These results suggest that, in patients who have been treated with RIF for mandibular bone fracture, HU values measured by CT vary across time, expressing the physiologic bone healing process.


Bone Density , Mandibular Fractures , Humans , Retrospective Studies , Bone Density/physiology , Mandibular Fractures/diagnostic imaging , Mandibular Fractures/surgery , Tomography, X-Ray Computed/methods , Tomography
16.
BMC Complement Med Ther ; 24(1): 143, 2024 Apr 04.
Article En | MEDLINE | ID: mdl-38575891

BACKGROUND: This study aimed to determine the therapeutic efficacy of curcumin nanoemulsion (CUR-NE) in mice infected with Echinococcus granulosus sensu stricto protoscoleces. METHODS: Forty-two inbred BALB/c mice were divided into seven groups of six animals each. Six groups were inoculated intra-peritoneally with 1500 viable E. granulosus protoscoleces, followed for six months and used as infected groups. The infected groups were named as: CEI1 to CEI6 accordingly. The 7th group was not inoculated and was named cystic echinococcosis noninfected group (CENI7). CEI1 and CEI2 groups received 40 mg/kg/day and 20 mg/kg/day curcumin nanoemulsion (CUR-NE), respectively. CEI3 received nanoemulsion without curcumin (NE-no CUR), CEI4 received curcumin suspension (CUR-S) 40 mg/kg/day, CEI5 received albendazole 150 mg/kg/day and CEI6 received sterile phosphate-buffered saline (PBS). CENI7 group received CUR-NE 40 mg/kg/day. Drugs administration was started after six months post-inoculations of protoscoleces and continued for 60 days in all groups. The secondary CE cyst area was evaluated by computed tomography (CT) scan for each mouse before treatment and on the days 30 and 60 post-treatment. The CT scan measurement results were compared before and after treatment. After the euthanasia of the mice on the 60th day, the cyst area was also measured after autopsy and, the histopathological changes of the secondary cysts for each group were observed. The therapeutic efficacy of CUR-NE in infected groups was evaluated by two methods: CT scan and autopsied cyst measurements. RESULTS: Septal calcification in three groups of infected mice (CEI1, CEI2, and CEI4) was revealed by CT scan. The therapeutic efficacy of CUR-NE 40 mg/kg/day (CEI1 group) was 24.6 ± 26.89% by CT scan measurement and 55.16 ± 32.37% by autopsied cysts measurements. The extensive destructive effects of CUR-NE 40 mg/kg/day (CEI1 group) on the wall layers of secondary CE cysts were confirmed by histopathology. CONCLUSION: The current study demonstrated a significant therapeutic effect of CUR-NE (40 mg/kg/day) on secondary CE cysts in BALB/c mice. An apparent septal calcification of several cysts revealed by CT scan and the destructive effect on CE cysts observed in histopathology are two critical key factors that suggest curcumin nanoemulsion could be a potential treatment for cystic echinococcosis.


Curcumin , Cysts , Echinococcosis , Animals , Mice , Curcumin/pharmacology , Curcumin/therapeutic use , Mice, Inbred BALB C , Echinococcosis/diagnostic imaging , Echinococcosis/drug therapy , Tomography
17.
Sci Rep ; 14(1): 9669, 2024 04 27.
Article En | MEDLINE | ID: mdl-38671072

Serious blunt chest trauma usually induces hemothorax, pneumothorax, and rib fractures. More studies have claimed that early video-assisted thoracoscopic surgery with surgical stabilization of rib fractures (SSRF) results in a good prognosis in patients with major trauma. This study aimed to verify the outcomes in patients with chest trauma whether SSRF was performed. Consecutive patients who were treated in a medical center in Taiwan, for traumatic events between January 2015 and June 2020, were retrospectively reviewed. This study focused on patients with major trauma and thoracic injuries, and they were divided into groups based on whether they received SSRF. We used electrical impedance tomography (EIT) to evaluate the change of ventilation conditions. Different scores used for the evaluation of trauma severity were also compared in this study. Among the 8396 patients who were included, 1529 (18.21%) had major trauma with injury severity score > 16 and were admitted to the intensive care unit initially. A total of 596 patients with chest trauma were admitted, of whom 519 (87%) survived. Younger age and a lower trauma score (including injury severity scale, new injury severity score, trauma and injury severity score, and revised trauma score) account for better survival rates. Moreover, 74 patients received SSRF. They had a shorter intensive care unit (ICU) stay (5.24, p = 0.045) and better performance in electrical impedance tomography (23.46, p < 0.001). In patients with major thoracic injury, older age and higher injury survival scale account for higher mortality rate. Effective surgical stabilization of rib fractures shortened the ICU stay and helped achieve better performance in EIT. Thoracoscope-assisted rib fixation is suggested in severe trauma cases.


Electric Impedance , Rib Fractures , Thoracic Injuries , Humans , Rib Fractures/surgery , Rib Fractures/diagnostic imaging , Female , Male , Middle Aged , Thoracic Injuries/surgery , Thoracic Injuries/diagnostic imaging , Adult , Retrospective Studies , Aged , Treatment Outcome , Thoracic Surgery, Video-Assisted/methods , Injury Severity Score , Tomography/methods
18.
Medicina (B Aires) ; 84(2): 359-363, 2024.
Article En | MEDLINE | ID: mdl-38683525

The apnea test, employed for brain death assessment, aims to demonstrate the absence of respiratory drive due to hypercapnia. The tracheal oxygen insufflation apnea test mode (I-AT) involves disconnecting the patient from invasive mechanical ventilation (iMV) for approximately 8 minutes while maintaining oxygenation. This test supports the diagnosis of brain death based on a specified increase in PaCO2. Common complications include hypoxemia and hemodynamic instability, and lung collapse-induced reduction in end-expiratory lung volume (EELV). In our case series utilizing electrical impedance tomography (EIT), we observed that continuous positive airway pressure during the apnea test (CPAP-AT) effectively mitigated lung collapse. This resulted in improved pulmonary strain compared to the disconnection of iMV. These findings suggest the potential benefits of routine CPAP-AT, particularly for potential lung donors, emphasizing the relevance of our study in providing quantitative insights into EELV loss and its association with pulmonary strain and potential lung injury.


La prueba de apnea es una técnica diagnóstica ampliamente utilizada para la evaluación de la muerte cerebral, con el objetivo de demostrar la ausencia de impulso respiratorio debido a la hipercapnia. La variante de la prueba de apnea con insuflación de oxígeno traqueal (I-AT) implica desconectar al paciente de la ventilación mecánica invasiva (iVM) durante aproximadamente 8 minutos, manteniendo la oxigenación mediante un catéter de insuflación. Esta prueba respalda el diagnóstico de muerte cerebral cuando se determina un aumento de la PaCO 2 superior a 20 mmHg en comparación con el valor inicial o un nivel de PaCO 2 superior a 60 mmHg al final de la prueba. En nuestra serie de casos, la implementación de la tomografía de impedancia eléctrica (EIT) reveló que la prueba de apnea con presión positiva continua (CPAPAT) mitiga eficazmente el colapso pulmonar. Este enfoque resulta en una mejora en la tensión pulmonar en comparación con la desconexión de iMV, demostrando su relevancia en el contexto de potenciales donantes de pulmones.


Electric Impedance , Lung Volume Measurements , Humans , Male , Female , Lung Volume Measurements/methods , Middle Aged , Apnea/physiopathology , Brain Death/physiopathology , Brain Death/diagnosis , Brain Death/diagnostic imaging , Adult , Tomography/methods , Continuous Positive Airway Pressure , Lung/diagnostic imaging , Lung/physiopathology , Aged
19.
Eur Respir J ; 63(4)2024 Apr.
Article En | MEDLINE | ID: mdl-38636970

BACKGROUND: Up to 50% of those attending for low-dose computed tomography screening for lung cancer continue to smoke and co-delivery of smoking cessation services alongside screening may maximise clinical benefit. Here we present data from an opt-out co-located smoking cessation service delivered alongside the Yorkshire Lung Screening Trial (YLST). METHODS: Eligible YLST participants were offered an immediate consultation with a smoking cessation practitioner (SCP) at their screening visit with ongoing smoking cessation support over subsequent weeks. RESULTS: Of 2150 eligible participants, 1905 (89%) accepted the offer of an SCP consultation during their initial visit, with 1609 (75%) receiving ongoing smoking cessation support over subsequent weeks. Uptake of ongoing support was not associated with age, ethnicity, deprivation or educational level in multivariable analyses, although men were less likely to engage (adjusted OR (ORadj) 0.71, 95% CI 0.56-0.89). Uptake was higher in those with higher nicotine dependency, motivation to stop smoking and self-efficacy for quitting. Overall, 323 participants self-reported quitting at 4 weeks (15.0% of the eligible population); 266 were validated by exhaled carbon monoxide (12.4%). Multivariable analyses of eligible smokers suggested 4-week quitting was more likely in men (ORadj 1.43, 95% CI 1.11-1.84), those with higher motivation to quit and previous quit attempts, while those with a stronger smoking habit in terms of cigarettes per day were less likely to quit. CONCLUSIONS: There was high uptake for co-located opt-out smoking cessation support across a wide range of participant demographics. Protected funding for integrated smoking cessation services should be considered to maximise programme equity and benefit.


Smoking Cessation , Tobacco Use Disorder , Male , Humans , Smoking Cessation/methods , Community Health Services , Lung , Tomography
20.
Waste Manag ; 182: 215-224, 2024 Jun 15.
Article En | MEDLINE | ID: mdl-38670005

Incidents of waste and biofuel fires are common at all stages of the waste recycling chain and have grave implications for business, employees, firefighters, society, and environment. An early detection of waste and biofuel fires in the smouldering stage could save precious lives, resources, and our environment. Existing fire detection methodologies e.g. handheld temperature sensors, IR cameras, gas sensors, and video and satellite-based monitoring techniques have inherent limitations to efficiently detect smouldering fires. An attempt was made to explore the potential of electrical resistivity tomography (ERT) as an alternate tool to address the problem. In the experiments an externally powered resistive wire was employed to initiate the smouldering fire inside the test material (wood pellets, wood shavings, wood fines). Time series of ERT that followed the initiation and development of smouldering were recorded using an automated monitoring instrument setup. The actual geometry of the experimental sample container and electrode setup was integrated in the 3D finite element method (FEM) model grid to perform inverse numerical modelling (inversion) and to develop resistivity tomographic images. The study shows a sharp increase in ratio of resistivity (R/Ro ≥ 50 %) in the test material in the region of smouldering hotspot and demonstrates the potential use of ERT technique for the detection of smouldering hotspots in silos and pile storage of organic material such as wood-based fuels, wood waste, coal, municipal solid waste (MSW), recyclables etc. More research is however required for enabling the use of this technique at the practical scale for different storage conditions.


Wood , Fires , Recycling/methods , Tomography/methods , Refuse Disposal/methods , Biofuels/analysis
...