Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 2.635
Filter
1.
Tech Coloproctol ; 28(1): 77, 2024 Jul 02.
Article in English | MEDLINE | ID: mdl-38954131

ABSTRACT

BACKGROUND: Bladder drainage is systematically used in rectal cancer surgery; however, the optimal type of drainage, transurethral catheterization (TUC) or suprapubic catheterization (SPC), is still controversial. The aim was to compare the rates of urinary tract infection on the fourth postoperative day (POD4) between TUC and SPC, after rectal cancer surgery regardless of the day of removal of the urinary drain. METHODS: This randomized clinical trial in 19 expert colorectal surgery centers in France and Belgium was performed between October 2016 and October 2019 and included 240 men (with normal or subnormal voiding function) undergoing mesorectal excision with low anastomosis for rectal cancer. Patients were followed at postoperative days 4, 30, and 180. RESULTS: In 208 patients (median age 66 years [IQR 58-71]) randomized to TUC (n = 99) or SPC (n = 109), the rate of urinary infection at POD4 was not significantly different whatever the type of drainage (11/99 (11.1%) vs. 8/109 (7.3%), 95% CI, - 4.2% to 11.7%; p = 0.35). There was significantly more pyuria in the TUC group (79/99 (79.0%) vs. (60/109 (60.9%), 95% CI, 5.7-30.0%; p = 0.004). No difference in bacteriuria was observed between the groups. Patients in the TUC group had a shorter duration of catheterization (median 4 [2-5] vs. 4 [3-5] days; p = 0.002). Drainage complications were more frequent in the SPC group at all followup visits. CONCLUSIONS: TUC should be preferred over SPC in male patients undergoing surgery for mid and/or lower rectal cancers, owing to the lower rate of complications and shorter duration of catheterization. TRIAL REGISTRATION: ClinicalTrials.gov identifier NCT02922647.


Subject(s)
Drainage , Postoperative Complications , Rectal Neoplasms , Urinary Catheterization , Urinary Tract Infections , Humans , Male , Rectal Neoplasms/surgery , Middle Aged , Aged , Urinary Catheterization/methods , Urinary Catheterization/adverse effects , Drainage/methods , Urinary Tract Infections/etiology , Urinary Tract Infections/prevention & control , Urinary Tract Infections/epidemiology , Postoperative Complications/etiology , Postoperative Complications/epidemiology , Urinary Bladder/surgery , Belgium
2.
Sci Rep ; 14(1): 15035, 2024 07 01.
Article in English | MEDLINE | ID: mdl-38951580

ABSTRACT

Intermittent catheterization (IC) utilizing conventional eyelets catheters (CECs) for bladder drainage has long been the standard of care. However, when the tissue of the lower urinary tract comes in close proximity to the eyelets, mucosal suction often occurs, resulting in microtrauma. This study investigates the impact of replacing conventional eyelets with a drainage zone featuring multiple micro-holes, distributing pressure over a larger area. Lower pressures limit the suction of surrounding tissue into these micro-holes, significantly reducing tissue microtrauma. Using an ex vivo model replicating the intra-abdominal pressure conditions of the bladder, the intra-catheter pressure was measured during drainage. When mucosal suction occurred, intra-catheter images were recorded. Subsequently affected tissue samples were investigated histologically. The negative pressure peaks caused by mucosal suction were found to be very high for the CECs, leading to exfoliation of the bladder urothelium and breakage of the urothelial barrier. However, a micro-hole zone catheter (MHZC) with a multi-eyelet drainage zone showed significantly lower pressure peaks, with over 4 times lower peak intensity, thus inducing far less extensive microtraumas. Limiting or even eliminating mucosal suction and resulting tissue microtrauma may contribute to safer catheterizations in vivo and increased patient comfort and compliance.


Subject(s)
Urinary Bladder , Urinary Catheters , Urinary Catheters/adverse effects , Animals , Humans , Pressure , Mucous Membrane/injuries , Swine , Urinary Tract , Intermittent Urethral Catheterization , Suction , Urothelium , Urinary Catheterization/adverse effects , Urinary Catheterization/methods , Urinary Catheterization/instrumentation
3.
BMC Geriatr ; 24(1): 483, 2024 Jun 03.
Article in English | MEDLINE | ID: mdl-38831267

ABSTRACT

BACKGROUND: Postoperative urinary retention (POUR) among older patients with hip fractures is common and may result in delayed ambulation, prolonged hospital stays, and urinary tract infections. Although preoperative urinary catheter indwelling and early postoperative removal can prevent perioperative urinary retention, this condition may occur in some patients after catheter removal, which requires urinary catheter re-indwelling or intermittent catheterization. Therefore, this study aims to identify risk factors and develop a screening tool for postoperative urinary retention in patients who have undergone operative treatment for fragility hip fractures subsequent to urinary catheter removal. METHODS: A prospective cohort study of 145 fragility hip fracture in older patients who were operatively treated between September 2020 and May 2022 was conducted. All patients were evaluated for urine retention after urinary catheter removal using a bladder scan. In addition, factors related to urinary retention were collected and utilized for screening tool development. RESULTS: Of the included patients, 22 (15.2%) were diagnosed with POUR. A multivariable logistic regression model using a stepwise backward elimination algorithm identified the current use of drugs with anticholinergic effect (OR = 11.9, p = 0.012), international prostate symptom score (IPSS) ≥ 8 (OR = 9.3, p < 0.001), and inability to independently get out of bed within 24 h postoperatively (OR = 6.5, p = 0.051) as risk factors of POUR. The screening tool that has been developed revealed an excellent performance (AuROC = 0.85, 95%CI 0.75 to 0.91) with good calibration and minimal optimism. CONCLUSIONS: Current use of drugs with anticholinergic effects, IPSS ≥ 8, and inability to independently get out of bed within 24 h postoperatively are significant variables of POUR. For additional external validation, a proposed scoring system for POUR screening was developed. TRIAL REGISTRATION: The study protocol was retrospectively registered in The Thai Clinical Trials Registry (TCTR20220502001: 2 May 2022).


Subject(s)
Hip Fractures , Postoperative Complications , Urinary Retention , Humans , Urinary Retention/etiology , Urinary Retention/epidemiology , Male , Female , Prospective Studies , Risk Factors , Hip Fractures/surgery , Postoperative Complications/diagnosis , Postoperative Complications/etiology , Postoperative Complications/epidemiology , Postoperative Complications/prevention & control , Aged, 80 and over , Aged , Urinary Catheterization/adverse effects , Urinary Catheterization/methods
4.
Sci Rep ; 14(1): 13273, 2024 06 10.
Article in English | MEDLINE | ID: mdl-38858470

ABSTRACT

In this study, we conducted a numerical analysis on catheter sizes using computational fluid dynamics to assess urinary flow rates during intermittent catheterization (IC). The results revealed that the fluid (urine) movement within a catheter is driven by intravesical pressure, with friction against the catheter walls being the main hindrance to fluid movement. Higher-viscosity fluids experienced increased friction with increasing intravesical pressure, resulting in reduced fluid velocity, whereas lower-viscosity fluids experienced reduced friction under similar pressure, leading to increased fluid velocity. Regarding urine characteristics, the results indicated that bacteriuria, with lower viscosity, exhibited higher flow rates, whereas glucosuria exhibited the lowest flow rates. Additionally, velocity gradients decreased with increasing catheter diameters, reducing friction and enhancing fluid speed, while the friction increased with decreasing diameters, reducing fluid velocity. These findings confirm that flow rates increased with larger catheter sizes. Furthermore, in terms of specific gravity, the results showed that a 12Fr catheter did not meet the ISO-suggested average flow rate (50 cc/min). The significance of this study lies in its application of fluid dynamics to nursing, examining urinary flow characteristics in catheterization. It is expected to aid nurses in selecting appropriate catheters for intermittent catheterization based on urinary test results.


Subject(s)
Hydrodynamics , Humans , Urinary Catheters , Viscosity , Urinary Catheterization/instrumentation , Urinary Catheterization/methods , Urine/chemistry , Catheters , Friction
5.
Spinal Cord Ser Cases ; 10(1): 42, 2024 Jun 12.
Article in English | MEDLINE | ID: mdl-38866780

ABSTRACT

STUDY DESIGN: Retrospective chart audit. OBJECTIVES: To evaluate the safety of ultrasound-guided percutaneous suprapubic catheter (SPC) insertion in patients with spinal cord injury/disease (SCI/D) and to attempt to identify risk factors for complications. SETTING: Specialized German centre for spinal cord injuries. METHODS: This retrospective chart analysis evaluated demographic, neurologic, and neuro-urologic data and the incidence and type of complications within the first 30 days after suprapubic bladder catheter insertion in SCI/D patients in the period between January 1st, 2013, and December 31st, 2022. RESULTS: The data of 721 SCI/D patients (244 women and 477 men, 386 tetraplegics and 355 paraplegics) were analysed. There were 44 complications (6.5%), of which 11 (1.5%) were major complications according to Clavien-Dindo ≥ 3. Among these were one small bowel injury and one peritoneal injury each, but no fatal complications. Regarding major complications (according to Clavien-Dindo ≥3), only patient age was identified as a risk factor (p = 0.0145). Gender, SCI/D level, neurological completeness, and severity of SCI/D or type of neurogenic lower urinary tract dysfunction (Odds ratio [95% CI] 1.6423 [0.4961;5.4361], 1.0421 [0.3152;3.4459], 0.3453 [0.0741;1.6101], 2.8379 [0.8567;9.4004] and 2.8095 [0.8097;9.7481] respectively) did not show any association with the frequency of major complications. CONCLUSIONS: Mild complications, especially temporary hematuria or infectious complications, are not uncommon after SPC insertion in SCI/D patients. Major complications occur only rarely, and no risk factor other than age could be detected. On this basis, pre-intervention education on informed consent for SCI/D patients can be provided on an evidence-based approach.


Subject(s)
Spinal Cord Injuries , Ultrasonography, Interventional , Urinary Catheterization , Humans , Spinal Cord Injuries/complications , Female , Male , Middle Aged , Adult , Retrospective Studies , Aged , Urinary Catheterization/methods , Urinary Catheterization/adverse effects , Ultrasonography, Interventional/methods , Risk Factors , Young Adult , Aged, 80 and over , Adolescent
6.
Arch Ital Urol Androl ; 96(2): 12395, 2024 May 09.
Article in English | MEDLINE | ID: mdl-38722152

ABSTRACT

OBJECTIVE: To analyze the static and dynamic urodynamic parameters of reservoirs and continent conduits in continent cutaneous urinary diversion with catheterizable stoma. MATERIALS AND METHODS: 76 patients had augmented ileocystoplasty or continent urinary diversion with catheterizable urinary stoma based on Mitrofanoff principle and Yang-Monti procedure using subserous tunnel as continence mechanism. They were followed up for at least 6 months post-operatively for continence through stoma and divided into two groups (continents vs non-continent) according to stomal continence. Both groups had urodynamic assessment performed via the stoma to assess reservoir capacity, pressure and contractions, efferent limb functional length, reservoir overactivity, static and dynamic maximal closure pressures and leak point pressure. RESULTS: Continence rate was 87%. Continent group included 66 patients and incontinent group included 10 patients. In both groups at rest, the reservoir pressure after filling did not exceed 25 cm H2O. During peristaltic contraction, the pressure did not exceed 30 cm H2O and the duct remained continent. After Valsalva maneuver, the reservoir pressure increased up to 34 (+ 7.4) cm H2O and leakage occur in 10 patients (13%). Reservoir (wall) overactivity was recorded in 54 patients, with insignificant rise in intraluminal pressure during the contractions. In both groups, the efferent tract closing pressure was always higher than the reservoir pressure. The mean of maximal closing pressure at Valsalva was 82.5 (+ 4.18) cm H2O in the continent group and 61.66 (+ 8.16) cm H2O in the incontinent group. The mean functional length of the conduit was 4.95 + 1.62 in the continent group and 2.80 + 1.50 cm in the incontinent group. CONCLUSIONS: Urodynamic evaluation of continent catheterizable cutaneous stoma after Yang-Monti procedure has a practical significance. Functional length of the conduit seems to be the most influential factor for continence reflecting static & dynamic maximal closure pressure. Higher conduit closing pressure is associated with better continence. Contractions of the pouch and peristaltic contraction of the conduit has no effect on continence mechanism.


Subject(s)
Urinary Incontinence , Urinary Reservoirs, Continent , Urodynamics , Humans , Male , Female , Middle Aged , Urinary Incontinence/physiopathology , Urinary Incontinence/surgery , Aged , Urinary Catheterization/methods , Urinary Diversion/methods , Follow-Up Studies , Postoperative Complications , Adult , Surgical Stomas
7.
Midwifery ; 135: 104026, 2024 Aug.
Article in English | MEDLINE | ID: mdl-38781793

ABSTRACT

OBJECTIVE: Assess the outcome of induction of labour (IOL) with a Foley catheter in pregnancies at 41 weeks in midwifery-led care setting compared to consultant-led care setting. DESIGN: Mixed-methods cohort study at a midwifery - hospital partnership in Amsterdam, the Netherlands. SETTING AND PARTICIPANTS: Prospectively, women undergoing IOL in midwifery-led care were recruited at a secondary hospital. This group was compared to a retrospective cohort, in which IOL was exclusively performed under consultant-led care. MEASUREMENTS AND FINDINGS: We compared 320 women whose induction started in midwifery-led care to a historical cohort of 320 women induced for the same reason under consultant-led care. Both groups exhibited similar rates of spontaneous vaginal births (64.2 %vs62.5 %). Caesarean section and assisted vaginal birth rates did not significantly differ. Maternal adverse outcomes were comparable, while neonatal adverse outcomes were significantly higher in the midwifery-led care group (8.1 %vs3.8 %; OR 2.27, 95 % CI 1.12-4.58). The use of pain relief was significantly lower in midwife-led care (65.3 %vs75.3 %; OR 0.62, 95 % CI 0.44-0.87). 20.6 % of births occurred in midwife-led care. KEY CONCLUSIONS AND IMPLICATIONS FOR PRACTICE: In this single-centre study, spontaneous vaginal birth rates following IOL with a Foley catheter were similar between midwife- and consultant-led care. However, the midwife-led group showed a higher risk of adverse neonatal outcomes, mainly early onset neonatal sepsis, with a minority eventually delivering under midwife-led care. Implications highlight the need for broader research, validation across diverse settings and exploration of patient and healthcare worker perspectives to refine the evolving midwifery-led care model.


Subject(s)
Labor, Induced , Midwifery , Humans , Female , Labor, Induced/statistics & numerical data , Labor, Induced/methods , Pregnancy , Netherlands , Adult , Midwifery/methods , Midwifery/statistics & numerical data , Retrospective Studies , Cohort Studies , Prospective Studies , Pregnancy Outcome/epidemiology , Urinary Catheterization/statistics & numerical data , Urinary Catheterization/methods , Urinary Catheterization/adverse effects , Urinary Catheterization/instrumentation
8.
Br J Nurs ; 33(9): S4-S8, 2024 May 09.
Article in English | MEDLINE | ID: mdl-38722016

ABSTRACT

Clean intermittent self-catheterisation (CISC) is considered the preferred option to an indwelling catheter for emptying the bladder in people with a range of voiding dysfunctions. CISC has a lower risk of complications and urinary tract infections. This narrative review of previous qualitative research explores the quality-of-life impacts and highlights the challenges that men face. It will provide nurses who teach CISC with some useful insights into the male experience and the issues of concordance and adherence. This will help to better inform and guide clinical practice in this specialist area of nursing practice.


Subject(s)
Intermittent Urethral Catheterization , Quality of Life , Self Care , Humans , Male , Urinary Catheterization/nursing , Urinary Catheterization/methods , Qualitative Research
9.
Br J Nurs ; 33(9): S10-S15, 2024 May 09.
Article in English | MEDLINE | ID: mdl-38722003

ABSTRACT

Clean intermittent self-catheterisation is a common procedure undertaken by people with bladder dysfunction. However, it is not without its complications, the main one being urinary tract infection. The most common causes of urinary tract infections are poor hygiene, technique and adherence, excessive post-void residual urine and bladder trauma. A catheter with new Micro-hole Zone Technology has been developed, which can potentially improve bladder emptying and minimise these complications. A case study is used to illustrate its effects in practice.


Subject(s)
Self Care , Humans , Intermittent Urethral Catheterization/instrumentation , Urinary Catheterization/methods , Urinary Catheterization/instrumentation , Urinary Tract Infections/prevention & control , Equipment Design , Urinary Catheters , Female , Male
10.
Crit Care ; 28(1): 162, 2024 05 13.
Article in English | MEDLINE | ID: mdl-38741134

ABSTRACT

BACKGROUND: The effect of the periurethral cleansing range on catheter-associated urinary tract infection (CAUTI) occurrence remains unknown. The purpose of this study was to evaluate the efficacy of expanded periurethral cleansing for reducing CAUTI in comatose patients. METHODS: In this randomized controlled trial, eligible patients in our hospital were enrolled and allocated randomly to the experimental group (expanded periurethral cleansing protocol; n = 225) or the control group (usual periurethral cleansing protocol; n = 221). The incidence of CAUTI on days 3, 7, and 10 after catheter insertion were compared, and the pathogen results and influencing factors were analyzed. RESULTS: The incidences of CAUTI in the experimental and control groups on days 3, 7, and 10 were (5/225, 2.22% vs. 7/221, 3.17%, P = 0.54), (12/225, 5.33% vs. 18/221, 8.14%, P = 0.24), and (23/225, 10.22% vs. 47/221, 21.27%, P = 0.001), respectively; Escherichia coli and Candida albicans were the most common species in the two groups. The incidences of bacterial CAUTI and fungal CAUTI in the two groups were 11/225, 4.89% vs. 24/221, 10.86%, P = 0.02) and (10/225, 4.44% vs. 14/221, 6.33%, P = 0.38), respectively. The incidences of polymicrobial CAUTI in the two groups were 2/225 (0.89%) and 9/221 (4.07%), respectively (P = 0.03). The percentages of CAUTI-positive females in the two groups were 9.85% (13/132) and 29.52% (31/105), respectively (P < 0.05). The proportion of CAUTI-positive patients with diabetes in the experimental and control groups was 17.72% (14/79), which was lower than the 40.85% (29/71) in the control group (P < 0.05). CONCLUSION: Expanded periurethral cleansing could reduce the incidence of CAUTI, especially those caused by bacteria and multiple pathogens, in comatose patients with short-term catheterization (≤ 10 days). Female patients and patients with diabetes benefit more from the expanded periurethral cleansing protocol for reducing CAUTI.


Subject(s)
Catheter-Related Infections , Coma , Urinary Tract Infections , Humans , Female , Urinary Tract Infections/prevention & control , Urinary Tract Infections/epidemiology , Male , Middle Aged , Catheter-Related Infections/prevention & control , Catheter-Related Infections/epidemiology , Adult , Aged , Urinary Catheterization/adverse effects , Urinary Catheterization/methods , Urethra
11.
BMC Pregnancy Childbirth ; 24(1): 401, 2024 May 31.
Article in English | MEDLINE | ID: mdl-38822253

ABSTRACT

BACKGROUND: Previous studies had found that the mechanical methods were as effective as pharmacological methods in achieving vaginal delivery. However, whether balloon catheter induction is suitable for women with severe cervical immaturity and whether it will increase the related risks still need to be further explored. RESEARCH AIM: To evaluate the efficacy and safety of Foley catheter balloon for labor induction at term in primiparas with different cervical scores. METHODS: A total of 688 primiparas who received cervical ripening with a Foley catheter balloon were recruited in this study. They were divided into 2 groups: Group 1 (Bishop score ≤ 3) and Group 2 (3 < Bishop score < 7). Detailed medical data before and after using of balloon were faithfully recorded. RESULTS: The cervical Bishop scores of the two groups after catheter placement were all significantly higher than those before (Group 1: 5.49 ± 1.31 VS 2.83 ± 0.39, P<0.05; Group 2: 6.09 ± 1.00 VS 4.45 ± 0.59, P<0.05). The success rate of labor induction in group 2 was higher than that in group 1 (P<0.05). The incidence of intrauterine infection in Group 1 was higher than that in Group 2 (18.3% VS 11.3%, P<0.05). CONCLUSION: The success rates of induction of labor by Foley catheter balloon were different in primiparas with different cervical conditions, the failure rate of induction of labor and the incidence of intrauterine infection were higher in primiparas with severe cervical immaturity.


Subject(s)
Cervical Ripening , Cervix Uteri , Labor, Induced , Humans , Labor, Induced/methods , Female , Pregnancy , Retrospective Studies , Adult , Parity , Catheterization/methods , Term Birth , Young Adult , Urinary Catheterization/methods , Urinary Catheterization/instrumentation , Catheters
12.
Urologie ; 63(6): 578-584, 2024 Jun.
Article in German | MEDLINE | ID: mdl-38639783

ABSTRACT

BACKGROUND: Urinary bladder tamponade is a urological emergency that is part of the clinical routine of every urologist and requires immediate and adequate diagnosis and therapy. OBJECTIVES: Presentation of the clinical picture of urinary bladder tamponade including etiology, diagnostics, and therapy as well as formulation of recommendations for action for clinical routine. MATERIALS AND METHODS: Structured presentation of the diagnosis and therapy of urinary bladder tamponade with practical recommendations for action based on a current literature search and a clinical case study. RESULTS: Urinary bladder tamponade is a usually painful filling of the urinary bladder with blood clots as part of gross hematuria. The central pillars of diagnostics are anamnesis, targeted physical examination, and sonography. Therapy involves the rapid insertion of a flushing catheter with manual evacuation of the tamponade. A flushing catheter with at least 20 French should be used here. CONCLUSION: Timely diagnosis and prompt treatment are crucial. This usually includes transurethral catheter insertion with manual evacuation. If the tamponade is unsuccessfully removed, further measures such as endoscopic evacuation or, as a last resort, sectio alta or radical cystectomy are available.


Subject(s)
Urinary Catheterization , Aged, 80 and over , Humans , Male , Emergencies , Hematuria/etiology , Hematuria/therapy , Hematuria/diagnosis , Urinary Bladder Diseases/therapy , Urinary Bladder Diseases/diagnosis , Urinary Catheterization/methods
13.
J Minim Invasive Gynecol ; 31(6): 533-540, 2024 Jun.
Article in English | MEDLINE | ID: mdl-38582258

ABSTRACT

STUDY OBJECTIVE: Temporary urinary retention after midurethral sling (MUS) surgery requiring indwelling catheter or self-catheterization usage is common. Different methods for assessment of immediate postoperative urinary retention have been described. This study aimed to compare postoperative voiding trial (VT) success after active vs passive VT in women undergoing MUS surgery. DESIGN: Comparative retrospective cohort study. SETTING: Female pelvic medicine and reconstructive surgery practice at a university-affiliated tertiary medical center. PATIENTS: Patients with stress urinary incontinence who underwent surgical treatment during the study period were eligible for inclusion. Excluded were patients younger than the age of 18 years, combined cases with other surgical services, planned laparotomy, and a history of urinary retention and patients for whom their VT was performed on postoperative day 1. The cohort was divided into 2 groups: (1) patients who underwent an active retrofill of their bladder using a Foley catheter and (2) patients who were allowed to have a spontaneous void. INTERVENTIONS: None. MEASUREMENTS AND MAIN RESULTS: A total of 285 patients met the inclusion criteria for the study. Of these subjects, 94 underwent an active VT and 191 underwent a passive VT. There were no statistically significant differences in immediate postoperative urinary retention (30.8% vs 29.3%; p = .79) or time from surgery end to VT (233.0 ± 167.6 minutes vs 203.1 ± 147.8 minutes; p = .13) between groups. Urinary retention, as defined by a failed VT, increased from 10% to 29.3% when MUS placement was accompanied by concomitant prolapse repair procedure. Multivariate logistic regression analysis revealed that undergoing a combined anterior and posterior colporrhaphy (odds ratio [OR], 5.13; p <.001) and undergoing an apical prolapse procedure (OR, 2.75; p = .004) were independently associated with immediate postoperative urinary retention whereas increased body mass index (OR, 0.89; p <.001) lowered likelihood of retention. CONCLUSION: The method used to assess immediate postoperative urinary retention did not affect VT success. Concomitant combined anterior and posterior colporrhaphy and apical suspension were correlated with greater likelihood of VT failure whereas increased body mass index decreased odds of retention.


Subject(s)
Postoperative Complications , Suburethral Slings , Urinary Incontinence, Stress , Urinary Retention , Humans , Female , Retrospective Studies , Urinary Retention/etiology , Middle Aged , Urinary Incontinence, Stress/surgery , Postoperative Complications/etiology , Postoperative Complications/epidemiology , Aged , Urinary Catheterization/methods , Urination/physiology , Adult
15.
Infect Dis Clin North Am ; 38(2): 343-360, 2024 Jun.
Article in English | MEDLINE | ID: mdl-38599895

ABSTRACT

This narrative review explores the use of external urinary catheters. These devices are available in various types and materials for male and female patients. The indications for the use of external urinary catheters include managing incontinence linked to overactive bladder and neurogenic lower urinary tract dysfunction. Contraindications to the use of external urinary catheters include urinary obstruction. Proper skin care and proactive infection control measures are necessary to prevent complications. The collection of a urine specimen for culture requires a standardized technique to prevent contamination. Clinician-led patient education on catheter management plays a important role in ensuring patient comfort and safety.


Subject(s)
Catheter-Related Infections , Urinary Catheters , Urinary Tract Infections , Humans , Urinary Catheters/adverse effects , Urinary Tract Infections/prevention & control , Urinary Tract Infections/therapy , Catheter-Related Infections/prevention & control , Urinary Catheterization/adverse effects , Urinary Catheterization/methods , Urinary Catheterization/instrumentation , Male , Female , Infection Control/methods
16.
Sci Rep ; 14(1): 9406, 2024 04 24.
Article in English | MEDLINE | ID: mdl-38658695

ABSTRACT

This retrospective study evaluated the safety and efficacy of fluoroscopy-guided urethral catheterization in patients who failed blind or cystoscopy-assisted urethral catheterization. We utilized our institutional database between January 2011 and March 2023, and patients with failed blind or cystoscopy-assisted urethral catheterization and subsequent fluoroscopy-guided urethral catheterization were included. A 5-Fr catheter was inserted into the urethral orifice, and the retrograde urethrography (RGU) was acquired. Subsequently, the operator attempted to pass a hydrophilic guidewire to the urethra. If the guidewire and guiding catheter could be successfully passed into the bladder, but the urethral catheter failed pass due to urethral stricture, the operator determined either attempted again with a reduced catheter diameter or performed balloon dilation according to their preference. Finally, an appropriately sized urethral catheter was selected, and an endhole was created using an 18-gauge needle. The catheter was then inserted over the wire to position the tip in the bladder lumen and ballooned to secure it. We reviewed patients' medical histories, the presence of hematuria, and RGU to determine urethral abnormalities. Procedure-related data were assessed. Study enrolled a total of 179 fluoroscopy-guided urethral catheterizations from 149 patients (all males; mean age, 73.3 ± 13.3 years). A total of 225 urethral strictures were confirmed in 141 patients, while eight patients had no strictures. Urethral rupture was confirmed in 62 patients, and hematuria occurred in 34 patients after blind or cystoscopy-assisted urethral catheterization failed. Technical and clinical success rates were 100%, and procedure-related complications were observed in four patients (2.2%). The mean time from request to urethral catheter insertion was 129.7 ± 127.8 min. The mean total fluoroscopy time was 3.5 ± 2.5 min and the mean total DAP was 25.4 ± 25.1 Gy cm2. Balloon dilation was performed in 77 patients. Total procedure time was 9.2 ± 7.6 min, and the mean procedure time without balloon dilation was 7.1 ± 5.7 min. Fluoroscopy-guided urethral catheterization is a safe and efficient alternative in patients where blind or cystoscopy-assisted urethral catheterization has failed or when cystoscopy-urethral catheterization cannot be performed.


Subject(s)
Cystoscopy , Urethral Stricture , Urinary Catheterization , Humans , Fluoroscopy/methods , Cystoscopy/methods , Cystoscopy/adverse effects , Male , Aged , Retrospective Studies , Middle Aged , Urethral Stricture/therapy , Urethral Stricture/diagnostic imaging , Urinary Catheterization/methods , Urinary Catheterization/adverse effects , Aged, 80 and over , Urethra/diagnostic imaging , Urethra/surgery
18.
Am J Obstet Gynecol MFM ; 6(4): 101349, 2024 Apr.
Article in English | MEDLINE | ID: mdl-38490333

ABSTRACT

BACKGROUND: Foley catheter insertion is frequently used for cervical ripening during the induction of labor. However, the insertion failure, safety, maternal side effects, complications, and satisfaction of digital compared with speculum-guided Foley catheter placement have not been evaluated in a large trial involving primigravida. OBJECTIVE: The study aimed to compare the insertion failure rate of digital and speculum-based transcervical Foley catheter placement in primigravida. The co-primary outcome was insertion-associated pain. The secondary outcomes were the time required for successful insertion, maternal satisfaction, and maternal complications within 24 hours of Foley insertion. STUDY DESIGN: This randomized, open-label, parallel-arm, noninferiority clinical trial was performed in a large tertiary care university hospital. Primigravida aged >18 years with term gestation (≥37 weeks) were included in this study. Additional inclusion criteria for enrollment in this study were singleton pregnancy with a cephalic presentation, intact membrane, a Bishop score of ≤5, and reassuring preinduction fetal heart rate tracing. All women planned for cervical ripening were assessed for eligibility and were randomized into digital or speculum arms. Foley catheter insertion was performed in a supine lithotomy position. Vaginal and cervical cleaning were performed before insertion. A 22-French Foley balloon catheter was guided digitally or via speculum to position the bulb at the level of the internal os using water-soluble lubricant. Insertion-associated pain was measured using a visual numeric rating scale, and maternal satisfaction was assessed using a set of questions. RESULTS: Four hundred and sixty-nine pregnant women were assessed for eligibility, and 446 patients were enrolled and randomized. The median age of the parturients was 24 (19-40) and 24 (18-38) years, respectively. The body mass index, gestational age at randomization, the incidence of postdated pregnancy, and prerandomization Bishop scores were comparable. Insertion failure was observed in 24 (10.8%) and 17 (7.6%) women in digital and speculum arms, respectively (relative risk=1.41 [95% confidence interval, 0.78-2.55]; P=.25). Requirements of >1 attempt (5.4% vs 3.6%) followed by the change in hands (3.6% vs 2.7%) were the most common reasons for insertion failure. The median (interquartile range) visual numeric rating scale was comparable (6 [2-9] vs 5 [2-10]; P=.15). The time taken for successful insertion was similar (58 [12-241] vs 54 [10-281]; P=.30). 9.4% and 10.8% of women required additional methods of cervical ripening. More women in the speculum group (41.7% vs 33.2%; P=.06) felt a medium level of discomfort than the digital group. CONCLUSION: Insertion failure and insertion-related pain in the digital approach were comparable to the speculum-guided approach for transcervical Foley catheter insertion in primigravida for cervical ripening. Nevertheless, maternal satisfaction was higher in the digital group because of a lesser level of discomfort.


Subject(s)
Cervical Ripening , Gravidity , Labor, Induced , Humans , Female , Pregnancy , Cervical Ripening/physiology , Adult , Labor, Induced/methods , Labor, Induced/instrumentation , Urinary Catheterization/methods , Urinary Catheterization/instrumentation , Surgical Instruments , Patient Satisfaction , Young Adult
19.
Int J Nurs Stud ; 154: 104742, 2024 Jun.
Article in English | MEDLINE | ID: mdl-38531196

ABSTRACT

BACKGROUND: Improper urethral catheterization may lead to complications such as urethral injury, catheter entanglement and urinary tract infection. Most of the related literature has focused on aseptic surgical technique, but there are no guidelines on the optimal insertion length for neonatal urinary catheterization. OBJECTIVE: To explore the external anatomical landmarks for urethral catheter positioning in male newborns. METHODS: This research is based on an observational study in Beijing Children's Hospital, China. Hospitalized male neonates who required Foley balloon catheters were prospectively enrolled in this study. The actual insertion length of the urethral catheter for male neonates and the anticipated insertion length based on anatomical landmarks were measured and compared. RESULTS: A total of 67 male neonates were enrolled. The mean body length was 50.66 ±â€¯2.93 cm, and the mean body weight was 3.33 ±â€¯0.70 kg. The mean actual insertion length of catheter was 8.77 ±â€¯0.94 cm, while the anticipated length was 10.89 ±â€¯0.95 cm. All the anticipated lengths exceeded the actual insertion length by 0.5-4.6 cm, which was deemed suitable for the procedure. CONCLUSIONS: Estimating the insertion length of urethral catheters based on external anatomical landmarks is clinically feasible. Selecting an anatomical landmark is a safe method for nurses or doctors to ensure the correct positioning of a urethral catheter. TWEETABLE ABSTRACT: The data of 67 male neonates shows that external anatomical landmarks for urethral catheter positioning in male newborns are possible.


Subject(s)
Urinary Catheterization , Urinary Catheters , Humans , Male , Infant, Newborn , Prospective Studies , Urinary Catheterization/methods , Urethra/anatomy & histology , Anatomic Landmarks
20.
J Gynecol Obstet Hum Reprod ; 53(5): 102770, 2024 May.
Article in English | MEDLINE | ID: mdl-38503382

ABSTRACT

OBJECTIVE: To compare Foley catheter insertion by digital blind method to its placement with a sterile speculum in women with unripe cervix for induction of labor. METHODS: A systematic search was conducted in Cochrane Library, PubMed, Web of Science, and Scopus databases for randomized clinical trials (RCTs) from inception to July 2023. Included studies compared digital to speculum placement of the Foley catheter for labor induction. Data from the included studies were extracted and pooled using RevMan software for meta-analysis. The primary outcome was pain score during the procedure measured by the Visual Analog Scale (VAS). Secondary outcomes included Foley catheter insertion duration, cesarean delivery rate, induction to delivery interval, Bishop score, need for other cervical ripening methods, maternal satisfaction, and maternal fever. RESULTS: Four RCTs involving a total of 600 patients met the inclusion criteria. Pain during the procedure and Foley catheter insertion duration were significantly reduced in the digital insertion group compared to the speculum-guided group (p < 0.05). The Bishop score showed a significant improvement in the digital Foley catheter placement group. However, there were no statistically significant differences in the cesarean delivery rate or the requirement for additional cervical ripening methods between the two groups. Maternal satisfaction with the delivery process was significantly improved in the digital insertion group (p < 0.001). Induction to delivery interval and maternal fever were comparable between both groups. CONCLUSIONS: Digital placement of Foley catheter can be considered as an alternative to the sterile speculum method for pre-induction cervical ripening. More trials are required to confirm our findings.


Subject(s)
Labor, Induced , Randomized Controlled Trials as Topic , Humans , Labor, Induced/methods , Labor, Induced/instrumentation , Female , Pregnancy , Cervical Ripening , Surgical Instruments , Cesarean Section/methods , Urinary Catheterization/methods , Urinary Catheterization/instrumentation
SELECTION OF CITATIONS
SEARCH DETAIL
...