1.
Crit Care Explor ; 6(7): e1113, 2024 Jul 01.
Article in English | MEDLINE | ID: mdl-38916647

ABSTRACT

CONTEXT: Amid the COVID-19 pandemic, this study delves into ventilator shortages, exploring simple split ventilation (SSV), simple differential ventilation (SDV), and differential multiventilation (DMV). The knowledge gap centers on understanding their performance and safety implications. HYPOTHESIS: Our hypothesis posits that SSV, SDV, and DMV offer solutions to the ventilator crisis. Rigorous testing was anticipated to unveil advantages and limitations, aiding the development of effective ventilation approaches. METHODS AND MODELS: Using a specialized test bed, SSV, SDV, and DMV were compared. Simulated lungs in a controlled setting facilitated measurements with sensors. Statistical analysis honed in on parameters like peak inspiratory pressure (PIP) and positive end-expiratory pressure. RESULTS: Setting target PIP at 15 cm H2O for lung 1 and 12.5 cm H2O for lung 2, SSV revealed a PIP of 15.67 ± 0.2 cm H2O for both lungs, with tidal volume (Vt) at 152.9 ± 9 mL. In SDV, lung 1 had a PIP of 25.69 ± 0.2 cm H2O, lung 2 at 24.73 ± 0.2 cm H2O, and Vts of 464.3 ± 0.9 mL and 453.1 ± 10 mL, respectively. DMV trials showed lung 1's PIP at 13.97 ± 0.06 cm H2O, lung 2 at 12.30 ± 0.04 cm H2O, with Vts of 125.8 ± 0.004 mL and 104.4 ± 0.003 mL, respectively. INTERPRETATION AND CONCLUSIONS: This study enriches understanding of ventilator sharing strategy, emphasizing the need for careful selection. DMV, offering individualization while maintaining circuit continuity, stands out. Findings lay the foundation for robust multiplexing strategies, enhancing ventilator management in crises.


Subject(s)
COVID-19 , Respiration, Artificial , Ventilators, Mechanical , Humans , Respiration, Artificial/methods , Respiration, Artificial/instrumentation , Tidal Volume , SARS-CoV-2 , Positive-Pressure Respiration/methods , Positive-Pressure Respiration/instrumentation
2.
J Spec Oper Med ; 24(2): 34-38, 2024 Jun 25.
Article in English | MEDLINE | ID: mdl-38837173

ABSTRACT

INTRODUCTION: Maximizing the capabilities of available lowflow oxygen is key to providing adequate oxygen to prevent/treat hypoxemia and conserve oxygen. We designed a closed-circuit system that allows rebreathing of gases while scrubbing carbon dioxide (CO2) in conjunction with portable mechanical ventilators in a bench model. METHODS: We evaluated the system using two portable mechanical ventilators currently deployed by the Department of Defense-Zoll 731 and AutoMedx SAVe II-over a range of ventilator settings and lung models, using 1 and 3L/min low-flow oxygen into a reservoir bag. We measured peak inspired oxygen concentration (FiO2), CO2-absorbent life, gas temperature and humidity, and the effect of airway suctioning and ventilator disconnection on FiO2 on ground and at altitude. RESULTS: FiO2 was =0.9 across all ventilator settings and altitudes using both oxygen flows. CO2-absorbent life was >7 hours. Airway humidity range was 87%-97%. Mean airway temperature was 25.4°C (SD 0.5°C). Ten-second suctioning reduced FiO2 22%-48%. Thirtysecond ventilator disconnect reduced FiO2 29%-63% depending on oxygen flow used. CONCLUSION: Use of a rebreathing system with mechanical ventilation has the potential for oxygen conservation but requires diligent monitoring of inspired FiO2 and CO2 to avoid negative consequences.


Subject(s)
Carbon Dioxide , Equipment Design , Oxygen , Ventilators, Mechanical , Humans , Carbon Dioxide/analysis , Oxygen/administration & dosage , Respiration, Artificial/instrumentation , Humidity , Temperature , Altitude
4.
Crit Care Explor ; 6(6): e1102, 2024 Jun 01.
Article in English | MEDLINE | ID: mdl-38842419

ABSTRACT

BACKGROUND: Tracheostomy-related acquired pressure injuries (TRPIs) are one of the hospital-acquired conditions. We hypothesize that an uneven ventilator circuit load, leading to non-neutral tracheostomy tube positioning in the immediate post-tracheostomy period, leads to an increased incidence of TRPIs. Does switching the ventilator circuit load daily, in addition to standard post-tracheostomy care, lead to a decreased incidence of TRPIs? METHODS: This is a prospective quality improvement study. Study was conducted at two academic hospital sites within tertiary care hospitals at Emory University in different ICUs. Consecutive patients undergoing bedside percutaneous tracheostomy by the interventional pulmonary service were included. The flip the ventilator circuit (FLIC) protocol was designed and implemented in selected ICUs, with other ICUs as controls. RESULTS: Incidence of TRPI in intervention and control group were recorded at post-tracheostomy day 5. A total of 99 patients were included from October 22, 2019, to May 22, 2020. Overall, the total incidence of any TRPI was 23% at post-tracheostomy day 5. Incidence of stage I, stage II, and stages III-IV TRPIs at postoperative day 5 was 11%, 12%, and 0%, respectively. There was a decrease in the rate of skin breakdown in patients following the FLIC protocol when compared with standard of care (13% vs. 36%; p = 0.01). In a multivariable analysis, interventional group had decreased odds of developing TRPI (odds ratio, 0.32; 95% CI, 0.11-0.92; p = 0.03) after adjusting for age, albumin, body mass index, diabetes mellitus, and days in hospital before tracheostomy. CONCLUSIONS: The incidence of TRPIs within the first week following percutaneous tracheostomy is high. Switching the side of the ventilator circuit to evenly distribute load, in addition to standard bundled tracheostomy care, may decrease the overall incidence of TRPIs.


Subject(s)
Pressure Ulcer , Tracheostomy , Humans , Tracheostomy/adverse effects , Tracheostomy/methods , Tracheostomy/instrumentation , Male , Female , Prospective Studies , Middle Aged , Aged , Pressure Ulcer/prevention & control , Pressure Ulcer/etiology , Pressure Ulcer/epidemiology , Incidence , Respiration, Artificial/adverse effects , Quality Improvement , Intensive Care Units , Ventilators, Mechanical/adverse effects
7.
Respir Care ; 69(7): 790-798, 2024 Jun 28.
Article in English | MEDLINE | ID: mdl-38744474

ABSTRACT

BACKGROUND: During invasive ventilation, external flow jet nebulization results in increases in displayed exhaled tidal volumes (VT). We hypothesized that the magnitude of the increase is inaccurate. An ASL 5000 simulator measured ventilatory parameters over a wide range of adult settings: actual VT, peak inspiratory pressure (PIP), and time to minimum pressure. METHODS: Ventilators with internal and external flow sensors were tested by using a variety of volume and pressure control modes (the target VT was 420 mL). Patient conditions (normal, COPD, ARDS) defined on the ASL 5000 were assessed at baseline and with 3.5 or 8 L/min of added external flow. Patient-triggering was assessed by reducing muscle effort to the level that resulted in backup ventilation and by changing ventilator sensitivity to the point of auto-triggering. RESULTS: Results are reported as percentage change from baseline after addition of 3.5 or 8 L/min external flow. For ventilators with internal flow sensors, changes in displayed exhaled VT ranged from 10% to 118%, however, when using volume control, actual increases in actual VT and PIP were only 4%-21% (P = .063, .031) and 6%-24% (P = .25, .031), respectively. Changes in actual VT correlated closely with changes in PIP (P < .001; R2 = 0.68). For pressure control, actual VT decreased by 3%-5% (P = .031) and 4%-9% (P = .031) with 3.5 and 8 L/min respectively, PIP was unchanged. With external flow sensors at the distal Y-piece junction, volume and pressure changes were statistically insignificant. The time to minimum pressure increased at most by 8% (P = .02) across all modes and ventilators. The effects on muscle pressure were minimal (∼1 cm H2O), and ventilator sensitivity effects were nearly undetectable. CONCLUSIONS: External flow jet nebulization resulted in much smaller changes in volume than indicated by the ventilator display. Statistically significant effects were confined primarily to machines with internal flow sensors. Differences approached the manufacturer-reported variation in ventilator baseline performance. During nebulizer therapy, effects on VT can be estimated at the bedside by monitoring PIP.


Subject(s)
Nebulizers and Vaporizers , Tidal Volume , Ventilators, Mechanical , Humans , Equipment Design , Pulmonary Disease, Chronic Obstructive/physiopathology , Pulmonary Disease, Chronic Obstructive/therapy , Respiratory Distress Syndrome/therapy , Respiratory Distress Syndrome/physiopathology , Maximal Respiratory Pressures , High-Frequency Jet Ventilation/instrumentation , High-Frequency Jet Ventilation/methods , Adult
8.
PLoS One ; 19(5): e0303443, 2024.
Article in English | MEDLINE | ID: mdl-38753734

ABSTRACT

INTRODUCTION: During the COVID-19 pandemic, ventilator shortages necessitated the development of new, low-cost ventilator designs. The fundamental requirements of a ventilator include precise gas delivery, rapid adjustments, durability, and user-friendliness, often achieved through solenoid valves. However, few solenoid-valve assisted low-cost ventilator (LCV) designs have been published, and gas exchange evaluation during LCV testing is lacking. This study describes the development and performance evaluation of a solenoid-valve assisted low-cost ventilator (SV-LCV) in vitro and in vivo, focusing on gas exchange and respiratory mechanics. METHODS: The SV-LCV, a fully open ventilator device, was developed with comprehensive hardware and design documentation, utilizing solenoid valves for gas delivery regulation. Lung simulator testing calibrated tidal volumes at specified inspiratory and expiratory times, followed by in vivo testing in a porcine model to compare SV-LCV performance with a conventional ventilator. RESULTS: The SV-LCV closely matched the control ventilator's respiratory profile and gas exchange across all test cycles. Lung simulator testing revealed direct effects of compliance and resistance changes on peak pressures and tidal volumes, with no significant changes in respiratory rate. In vivo testing demonstrated comparable gas exchange parameters between SV-LCV and conventional ventilator across all cycles. Specifically, in cycle 1, the SV-LCV showed arterial blood gas (ABG) results of pH 7.54, PCO2 34.5 mmHg, and PO2 91.7 mmHg, compared to the control ventilator's ABG of pH 7.53, PCO2 37.1 mmHg, and PO2 134 mmHg. Cycle 2 exhibited ABG results of pH 7.53, PCO2 33.6 mmHg, and PO2 84.3 mmHg for SV-LCV, and pH 7.5, PCO2 34.2 mmHg, and PO2 93.5 mmHg for the control ventilator. Similarly, cycle 3 showed ABG results of pH 7.53, PCO2 32.1 mmHg, and PO2 127 mmHg for SV-LCV, and pH 7.5, PCO2 35.5 mmHg, and PO2 91.3 mmHg for the control ventilator. CONCLUSION: The SV-LCV provides similar gas exchange and respiratory mechanic profiles compared to a conventional ventilator. With a streamlined design and performance akin to commercially available ventilators, the SV-LCV presents a viable, readily available, and reliable short-term solution for overcoming ventilator supply shortages during crises.


Subject(s)
COVID-19 , Pulmonary Gas Exchange , Respiratory Mechanics , Ventilators, Mechanical , Animals , Swine , Equipment Design , Respiration, Artificial/instrumentation , Respiration, Artificial/methods , SARS-CoV-2 , Tidal Volume
9.
PLoS One ; 19(5): e0297880, 2024.
Article in English | MEDLINE | ID: mdl-38768181

ABSTRACT

INTRODUCTION: Hyperinflation is a common procedure to clear secretion, increase lung compliance and enhance oxygenation in mechanically ventilated patients. Hyperinflation can be provided as manual hyperinflation (MHI) or ventilator hyperinflation (VHI), where outcomes depend upon the methods of application. Hence it is crucial to assess the application of techniques employed in Sri Lanka due to observed variations from recommended practices. OBJECTIVE: This study is aimed to evaluate the application and parameters used for MHI and VHI by physiotherapists in intensive care units (ICUs) in Sri Lanka. METHODOLOGY: An online survey was conducted among physiotherapists who are working in ICUs in Sri Lanka using WhatsApp groups and other social media platforms. RESULTS: A total of 96 physiotherapists responded. The survey comprised of three sections to obtain information about socio-demographic data, MHI practices and VHI practices. Most of the respondents (47%) worked in general hospitals and 74% of participants had a bachelor's degree in physiotherapy; 31.3% had 3-6 years of experience; 93.8% used hyperinflation, and 78.9% used MHI. MHI was performed routinely and as needed to treat low oxygen levels, abnormal breath sounds, and per physician orders while avoiding contraindications. Self-inflation bags are frequently used for MHI (40.6%). Only a few participants (26%) used a manometer or tracked PIP. In addition to the supine position, some participants (37.5%) used the side-lying position. Most physiotherapists followed the recommended MHI technique: slow squeeze (57.3%), inspiratory pause (45.8%), and quick release (70.8%). VHI was practised by 19.8%, with medical approval and it was frequently performed by medical staff compared to physiotherapists. Treatment time, number of breaths, and patient positioning varied, and parameters were not well-defined. CONCLUSION: The study found that MHI was not applied with the recommended PIP, and VHI parameters were not identified. The study indicates a need to educate physiotherapists about current VHI and MHI practice guidelines.


Subject(s)
Physical Therapists , Respiration, Artificial , Humans , Sri Lanka , Surveys and Questionnaires , Respiration, Artificial/methods , Male , Female , Adult , Intensive Care Units , Critical Care/methods , Ventilators, Mechanical/statistics & numerical data
11.
Cardiol Clin ; 42(2): 253-271, 2024 05.
Article in English | MEDLINE | ID: mdl-38631793

ABSTRACT

This review aims to enhance the comprehension and management of cardiopulmonary interactions in critically ill patients with cardiovascular disease undergoing mechanical ventilation. Highlighting the significance of maintaining a delicate balance, this article emphasizes the crucial role of adjusting ventilation parameters based on both invasive and noninvasive monitoring. It provides recommendations for the induction and liberation from mechanical ventilation. Special attention is given to the identification of auto-PEEP (positive end-expiratory pressure) and other situations that may impact hemodynamics and patients' outcomes.


Subject(s)
Emergencies , Respiration, Artificial , Humans , Positive-Pressure Respiration , Ventilators, Mechanical , Lung
12.
J Clin Monit Comput ; 38(3): 679-690, 2024 Jun.
Article in English | MEDLINE | ID: mdl-38557919

ABSTRACT

This study aims to resolve the unmet need for ventilator surge capacity by developing a prototype device that can alter patient-specific flow in a shared ventilator setup. The device is designed to deliver a predictable tidal volume (VT), requiring minimal additional monitoring and workload. The prototyped device was tested in an in vitro bench setup for its performance against the intended use and design criteria. The ventilation parameters: VT and airway pressures, and ventilation profiles: pressure, flow and volume were measured for different ventilator and device settings for a healthy and ARDS simulated lung pathology. We obtained VTs with a linear correlation with valve openings from 10 to 100% across set inspiratory pressures (IPs) of 20 to 30 cmH2O. Airway pressure varied with valve opening and lung elastance but did not exceed set IPs. Performance was consistent in both healthy and ARDS-simulated lung conditions. The ventilation profile diverged from traditional pressure-controlled profiles. We present the design a flow modulator to titrate VTs in a shared ventilator setup. Application of the flow modulator resulted in a characteristic flow profile that differs from pressure- or volume controlled ventilation. The development of the flow modulator enables further validation of the Individualized Shared Ventilation (ISV) technology with individualization of delivered VTs and the development of a clinical protocol facilitating its clinical use during a ventilator surge capacity problem.


Subject(s)
Equipment Design , Lung , Respiration, Artificial , Respiratory Distress Syndrome , Tidal Volume , Ventilators, Mechanical , Humans , Respiration, Artificial/instrumentation , Respiration, Artificial/methods , Respiratory Distress Syndrome/therapy , Respiratory Distress Syndrome/physiopathology , Lung/physiopathology , Pressure
13.
Crit Care Med ; 52(7): 1021-1031, 2024 Jul 01.
Article in English | MEDLINE | ID: mdl-38563609

ABSTRACT

OBJECTIVES: Nonconventional ventilators (NCVs), defined here as transport ventilators and certain noninvasive positive pressure devices, were used extensively as crisis-time ventilators for intubated patients with COVID-19. We assessed whether there was an association between the use of NCV and higher mortality, independent of other factors. DESIGN: This is a multicenter retrospective observational study. SETTING: The sample was recruited from a single healthcare system in New York. The recruitment period spanned from March 1, 2020, to April 30, 2020. PATIENTS: The sample includes patients who were intubated for COVID-19 acute respiratory distress syndrome (ARDS). INTERVENTIONS: None. MEASUREMENTS AND MAIN RESULTS: The primary outcome was 28-day in-hospital mortality. Multivariable logistic regression was used to derive the odds of mortality among patients managed exclusively with NCV throughout their ventilation period compared with the remainder of the sample while adjusting for other factors. A secondary analysis was also done, in which the mortality of a subset of the sample exclusively ventilated with NCV was compared with that of a propensity score-matched subset of the control group. Exclusive use of NCV was associated with a higher 28-day in-hospital mortality while adjusting for confounders in the regression analysis (odds ratio, 1.41; 95% CI [1.07-1.86]). In the propensity score matching analysis, the mortality of patients exclusively ventilated with NCV was 68.9%, and that of the control was 60.7% ( p = 0.02). CONCLUSIONS: Use of NCV was associated with increased mortality among patients with COVID-19 ARDS. More lives may be saved during future ventilator shortages if more full-feature ICU ventilators, rather than NCVs, are reserved in national and local stockpiles.


Subject(s)
COVID-19 , Hospital Mortality , Respiratory Distress Syndrome , Ventilators, Mechanical , Humans , COVID-19/therapy , COVID-19/mortality , Male , Female , Retrospective Studies , Middle Aged , Aged , Respiratory Distress Syndrome/therapy , Respiratory Distress Syndrome/mortality , Ventilators, Mechanical/supply & distribution , Ventilators, Mechanical/statistics & numerical data , New York/epidemiology , Respiration, Artificial/statistics & numerical data
14.
Crit Care ; 28(1): 107, 2024 04 02.
Article in English | MEDLINE | ID: mdl-38566126

ABSTRACT

BACKGROUND: Pre-clinical studies suggest that dyssynchronous diaphragm contractions during mechanical ventilation may cause acute diaphragm dysfunction. We aimed to describe the variability in diaphragm contractile loading conditions during mechanical ventilation and to establish whether dyssynchronous diaphragm contractions are associated with the development of impaired diaphragm dysfunction. METHODS: In patients receiving invasive mechanical ventilation for pneumonia, septic shock, acute respiratory distress syndrome, or acute brain injury, airway flow and pressure and diaphragm electrical activity (Edi) were recorded hourly around the clock for up to 7 days. Dyssynchronous post-inspiratory diaphragm loading was defined based on the duration of neural inspiration after expiratory cycling of the ventilator. Diaphragm function was assessed on a daily basis by neuromuscular coupling (NMC, the ratio of transdiaphragmatic pressure to diaphragm electrical activity). RESULTS: A total of 4508 hourly recordings were collected in 45 patients. Edi was low or absent (≤ 5 µV) in 51% of study hours (median 71 h per patient, interquartile range 39-101 h). Dyssynchronous post-inspiratory loading was present in 13% of study hours (median 7 h per patient, interquartile range 2-22 h). The probability of dyssynchronous post-inspiratory loading was increased with reverse triggering (odds ratio 15, 95% CI 8-35) and premature cycling (odds ratio 8, 95% CI 6-10). The duration and magnitude of dyssynchronous post-inspiratory loading were associated with a progressive decline in diaphragm NMC (p < 0.01 for interaction with time). CONCLUSIONS: Dyssynchronous diaphragm contractions may impair diaphragm function during mechanical ventilation. TRIAL REGISTRATION: MYOTRAUMA, ClinicalTrials.gov NCT03108118. Registered 04 April 2017 (retrospectively registered).


Subject(s)
Respiration, Artificial , Respiratory Distress Syndrome , Humans , Diaphragm , Respiration, Artificial/adverse effects , Thorax , Ventilators, Mechanical
16.
Respir Care ; 69(7): 773-781, 2024 Jun 28.
Article in English | MEDLINE | ID: mdl-38653558

ABSTRACT

BACKGROUND: The interpretation of ventilator waveforms is essential for effective and safe mechanical ventilation but requires specialized training and expertise. This study aimed to investigate the ability of ICU professionals to interpret ventilator waveforms, identify areas requiring further education and training, and explore the factors influencing their interpretation skills. METHODS: We conducted an international online anonymous survey of ICU professionals (physicians, nurses, and respiratory therapists [RTs]), with ≥ 1 y of experience working in the ICU. The survey consisted of demographic information and 15 multiple-choice questions related to ventilator waveforms. Results were compared between professions using descriptive statistics, and logistic regression (expressed as odds ratios [ORs; 95% CI]) was performed to identify factors associated with high performance, which was defined by a threshold of 60% correct answers. RESULTS: A total of 1,832 professionals from 31 countries or regions completed the survey; 53% of respondents answered ≥ 60% of the questions correctly. The 3 questions with the most correct responses were related to waveforms that demonstrated condensation (90%), pressure overshoot (79%), and bronchospasm (75%). Conversely, the 3 questions with the fewest correct responses were waveforms that demonstrated early cycle leading to double trigger (43%), severe under assistance (flow starvation) (37%), and early/reverse trigger (31%). Factors significantly associated with ≥ 60% correct answers included years of ICU working experience (≥ 10 y, OR 1.6 [1.2-2.0], P < .001), profession (RT, OR 2.8 [2.1-3.7], P < .001), highest degree earned (graduate, OR 1.7 [1.3-2.2], P < .001), workplace (teaching hospital, OR 1.4 [1.1-1.7], P = .008), and prior ventilator waveforms training (OR 1.7 [1.3-2.2], P < .001). CONCLUSIONS: Slightly over half respondents correctly identified ≥ 60% of waveforms demonstrating patient-ventilator discordance. High performance was associated with ≥ 10 years of ICU working experience, RT profession, graduate degree, working in a teaching hospital, and prior ventilator waveforms training. Some discordances were poorly recognized across all groups of surveyed professionals.


Subject(s)
Intensive Care Units , Respiration, Artificial , Ventilators, Mechanical , Humans , Intensive Care Units/statistics & numerical data , Surveys and Questionnaires , Respiration, Artificial/statistics & numerical data , Ventilators, Mechanical/statistics & numerical data , Male , Female , Clinical Competence/statistics & numerical data , Adult , Respiratory Therapy , Middle Aged , Logistic Models
17.
Disaster Med Public Health Prep ; 18: e65, 2024 Apr 12.
Article in English | MEDLINE | ID: mdl-38606429

ABSTRACT

OBJECTIVES: Future pandemics may cause more severe respiratory illness in younger age groups than COVID-19, requiring many more mechanical ventilators. This publication synthesizes the experiences of diverse contributors to Medtronic's mechanical ventilator supply chain during the pandemic, serving as a record of what worked and what didn't, while identifying key factors affecting production ramp-up in this healthcare crisis. METHOD: In-depth, one-on-one interviews (n = 17) were held with key Medtronic personnel and suppliers. Template analysis was used, and interview content was analyzed for signals, initiatives, actions, and outcomes, as well as influencing forces. RESULTS: Key findings revealed many factors limiting ventilator production ramp-up. Supply chain strengths and weaknesses were identified. Political factors played a role in allocating ventilators and also supported production. Commercial considerations were not priority, but economic awareness was essential to support suppliers. Workers were motivated and flexible. Component shortages, space, production processes, and logistics were challenges. Legally based pressures were reported e.g., import and export restrictions. CONCLUSION: Crisis response alone is not enough; preparation is essential. Coordinated international strategies are more effective than individual country responses. Supply chain resilience based on visibility and flexibility is key. This research can help public health planners and the medical device industry prepare for future healthcare crises.


Subject(s)
COVID-19 , Humans , COVID-19/epidemiology , Pandemics/prevention & control , Pandemic Preparedness , Public Health , Ventilators, Mechanical
18.
Nursing ; 54(5): 17-25, 2024 May 01.
Article in English | MEDLINE | ID: mdl-38640027

ABSTRACT

ABSTRACT: Mechanical ventilation is rarely a simple matter. Skill and knowledge are required to operate the ventilator modes, choose the optimal settings, and understand many monitored variables. Supporting the patient safely and effectively is the top priority in providing mechanical ventilation. This article discusses mechanical ventilation in adults.


Subject(s)
Respiration, Artificial , Ventilators, Mechanical , Adult , Humans
20.
Clin Plast Surg ; 51(2): 221-232, 2024 Apr.
Article in English | MEDLINE | ID: mdl-38429045

ABSTRACT

Sustaining an inhalation injury increases the risk of severe complications and mortality. Current evidential support to guide treatment of the injury or subsequent complications is lacking, as studies either exclude inhalation injury or design limit inferences that can be made. Conventional ventilator modes are most commonly used, but there is no consensus on optimal strategies. Settings should be customized to patient tolerance and response. Data for pharmacotherapy adjunctive treatments are limited.


Subject(s)
Burns , Respiratory Insufficiency , Humans , Ventilators, Mechanical , Consensus , Critical Care , Respiratory Insufficiency/etiology , Respiratory Insufficiency/therapy
SELECTION OF CITATIONS
SEARCH DETAIL
...