Your browser doesn't support javascript.
loading
Montrer: 20 | 50 | 100
Résultats 1 - 20 de 78
Filtrer
1.
Article de Anglais | MEDLINE | ID: mdl-38693866

RÉSUMÉ

AIMS: Evaluation of left and right ventricular longitudinal systolic function may enhance risk stratification following aortic valve replacement (AVR). The study objective was to evaluate the changes in left and right ventricular longitudinal systolic function and RV-pulmonary artery (RV-PA) coupling from baseline to 30-days and 1-year after aortic valve replacement (AVR). METHODS AND RESULTS: LV longitudinal strain (LS), tricuspid annulus plane systolic excursion (TAPSE), and RV-PA coupling were evaluated in patients from the PARTNER-2A surgical AVR (SAVR) arm (n=985) and from the PARTNER-2 SAPIEN-3 registry (n=719). TAPSE and RV-PA coupling decreased significantly following SAVR, but remained stable following TAVR. Lower LV LS, TAPSE, or RV-PA coupling at baseline were associated with increased risk of the composite of death, hospitalization, and stroke at 5-years (Adjusted-HRs for LV LS<15%: 1.24 95%CI 1.05-1.45, p=0.001; TAPSE<14mm: 1.44 95%CI 1.21-1.73, p<0.001; RV/PA coupling<0.55mm/mmHg: 1.32 95% CI 1.07-1.63, p=0.011). Reduced TAPSE at baseline was the most powerful predictor of the composite endpoint at 5-years. Patients with LV ejection fraction <50% at baseline had increased risk of the primary endpoint with SAVR (HR: 1.34, 95%CI 1.08-1.68, p=0.009) but not with TAVR (HR: 1.12, 95%CI 0.88-1.42). Lower RV-PA coupling at 30-days showed the strongest association with cardiac mortality. CONCLUSION: SAVR but not TAVR was associated with a marked deterioration in RV longitudinal systolic function and RV-PA coupling. Lower TAPSE and RV-PA coupling at 30-days were associated with inferior clinical outcomes at 5-years. In patients with LVEF<50%, TAVR was associated with superior 5-year outcomes.

2.
Article de Anglais | MEDLINE | ID: mdl-38795108

RÉSUMÉ

BACKGROUND: Functional mitral regurgitation induces adverse effects on the left ventricle and the left atrium. Left atrial (LA) dilatation and reduced LA strain are associated with poor outcomes in heart failure (HF). Transcatheter edge-to-edge repair (TEER) of the mitral valve reduces heart failure hospitalization (HFH) and all-cause death in selected HF patients. OBJECTIVES: The aim of this study was to evaluate the impact of LA strain improvement 6 months after TEER on the outcomes of patients enrolled in the COAPT (Cardiovascular Outcomes Assessment of the MitraClip Percutaneous Therapy for Heart Failure Patients With Functional Mitral Regurgitation) trial. METHODS: The difference in LA strain between baseline and the 6-month follow-up was calculated. Patients with at least a 15% improvement in LA strain were labeled as "LA strain improvers." All-cause death and HFH were assessed between the 6 and 24-month follow-up. RESULTS: Among 347 patients (mean age 71 ± 12 years, 63% male), 106 (30.5%) showed improvement of LA strain at the 6-month follow-up (64 [60.4%] from the TEER + guideline-directed medical therapy [GDMT] group and 42 [39.6%] from the GDMT alone group). An improvement in LA strain was significantly associated with a reduction in the composite of death or HFH between the 6-month and 24-month follow-up, with a similar risk reduction in both treatment arms (Pinteraction = 0.27). In multivariable analyses, LA strain improvement remained independently associated with a lower risk of the primary composite endpoint both as a continuous variable (adjusted HR: 0.94 [95% CI: 0.89-1.00]; P = 0.03) and as a dichotomous variable (adjusted HR: 0.49 [95% CI: 0.27-0.89]; P = 0.02). The best outcomes were observed in patients treated with TEER in whom LA strain improved. CONCLUSIONS: In symptomatic HF patients with severe mitral regurgitation, improved LA strain at the 6-month follow-up is associated with subsequently lower rates of the composite endpoint of all-cause mortality or HFH, both after TEER and GDMT alone. (Cardiovascular Outcomes Assessment of the MitraClip Percutaneous Therapy for Heart Failure Patients With Functional Mitral Regurgitation [COAPT]; NCT01626079).

3.
Ann Thorac Surg ; 117(6): 1164-1171, 2024 Jun.
Article de Anglais | MEDLINE | ID: mdl-38316377

RÉSUMÉ

BACKGROUND: Our objective was to compare the impact of patient-prosthesis mismatch (PPM) for 2 years after surgical aortic valve replacement within the prospective, randomized Placement of Aortic Transcatheter Valves (PARTNER) trials. METHODS: Surgical aortic valve replacement patients from the PARTNER 1, 2, and 3 trials were included. PPM was classified as moderate (indexed effective orifice area ≤0.85 cm2/m2) or severe (indexed effective orifice area ≤0.65 cm2/m2). The primary endpoint was the composite of all-cause death and heart failure rehospitalization at 2 years. RESULTS: By the predicted PPM method (PPMP), 59.1% had no PPM, 38.8% moderate PPM, and 2.1% severe PPM; whereas by the measured PPM method (PPMM), 42.4% had no PPM, 36.0% moderate, and 21.6% severe. Patients with no PPMP (23.6%) had a lower rate of the primary endpoint compared with patients with moderate (28.2%, P = .03) or severe PPMP (38.8%, P = .02). Using the PPMM method, there was no difference between the no (17.7%) and moderate PPMM groups (21.1%) in the primary outcome (P = .16). However, those with no PPMM or moderate PPMM were improved compared with severe PPMM (27.4%, P < .001 and P = .02, respectively). CONCLUSIONS: Severe PPM analyzed by PPMP was only 2.1% for surgical aortic valve replacement patients. The PPMM method overestimated the incidence of severe PPM relative to PPMP, but was also associated with worse outcome. There was higher all-cause mortality in patients with severe PPM, thus surgical techniques to minimize PPM remain critical.


Sujet(s)
Sténose aortique , Prothèse valvulaire cardiaque , Humains , Femelle , Mâle , Sujet âgé , Sténose aortique/chirurgie , Études prospectives , Remplacement valvulaire aortique par cathéter/méthodes , Remplacement valvulaire aortique par cathéter/effets indésirables , Valve aortique/chirurgie , Complications postopératoires/épidémiologie , Implantation de valve prothétique cardiaque/méthodes , Implantation de valve prothétique cardiaque/effets indésirables , Conception de prothèse , Sujet âgé de 80 ans ou plus , Résultat thérapeutique , Essayage de prothèse
4.
Struct Heart ; 8(1): 100225, 2024 Jan.
Article de Anglais | MEDLINE | ID: mdl-38283566

RÉSUMÉ

Background: Baseline left ventricular diastolic dysfunction (LVDD) is associated with poor health status in patients with severe aortic stenosis undergoing transcatheter aortic valve replacement (TAVR), but health status improvement after TAVR appears similar across all grades of LVDD. Here, we aim to examine the relationship between changes in LVDD severity and health status outcomes following TAVR. Methods: Patients who underwent TAVR and had evaluable LVDD at both baseline and 1 year in the PARTNER (Placement of Aortic Transcatheter Valves) 2 SAPIEN 3 registries and PARTNER 3 trial were analyzed. LVDD grade was evaluated using echocardiography core lab data and an adapted definition of American Society of Echocardiography guidelines. Health status was assessed using the Kansas City Cardiomyopathy Questionnaire Overall Summary (KCCQ-OS) score. The association between ΔLVDD severity and ΔKCCQ-OS was examined using linear regression models adjusted for baseline KCCQ-OS. Results: Of 1100 patients, 724 (65.8%), 283 (25.7%), and 93 (8.5%) had grade 0/1, 2, and 3 LVDD at baseline, respectively. At 1 year, LVDD severity was unchanged in 790 (71.8%) patients, improved in 189 (17.2%), and worsened in 121 (11.0%). Among 376 patients with baseline grade 2 or 3 LVDD, 50.3% had improvement in LVDD. In the overall cohort, KCCQ-OS score improved by 21.9 points at 1 year. There was a statistically significant association between change in LVDD severity (improved, unchanged, and worsened) and ΔKCCQ-OS at 1 year (p = 0.007). Conclusions: Change in LVDD grade was associated with change in health status 1 year following TAVR.

5.
Eur Heart J ; 44(43): 4508-4532, 2023 11 14.
Article de Anglais | MEDLINE | ID: mdl-37793121

RÉSUMÉ

Interest in the pathophysiology, etiology, management, and outcomes of patients with tricuspid regurgitation (TR) has grown in the wake of multiple natural history studies showing progressively worse outcomes associated with increasing TR severity, even after adjusting for multiple comorbidities. Historically, isolated tricuspid valve surgery has been associated with high in-hospital mortality rates, leading to the development of transcatheter treatment options. The aim of this first Tricuspid Valve Academic Research Consortium document is to standardize definitions of disease etiology and severity, as well as endpoints for trials that aim to address the gaps in our knowledge related to identification and management of patients with TR. Standardizing endpoints for trials should provide consistency and enable meaningful comparisons between clinical trials. A second Tricuspid Valve Academic Research Consortium document will focus on further defining trial endpoints and will discuss trial design options.


Sujet(s)
Implantation de valve prothétique cardiaque , Insuffisance tricuspide , Humains , Insuffisance tricuspide/diagnostic , Insuffisance tricuspide/chirurgie , Insuffisance tricuspide/étiologie , Valve atrioventriculaire droite/chirurgie , Implantation de valve prothétique cardiaque/effets indésirables , Cathétérisme cardiaque/effets indésirables , Résultat thérapeutique , Indice de gravité de la maladie
6.
Ann Thorac Surg ; 116(5): 908-932, 2023 11.
Article de Anglais | MEDLINE | ID: mdl-37804270

RÉSUMÉ

Interest in the pathophysiology, etiology, management, and outcomes of patients with tricuspid regurgitation (TR) has grown in the wake of multiple natural history studies showing progressively worse outcomes associated with increasing TR severity, even after adjusting for multiple comorbidities. Historically, isolated tricuspid valve surgery has been associated with high in-hospital mortality rates, leading to the development of transcatheter treatment options. The aim of this first Tricuspid Valve Academic Research Consortium document is to standardize definitions of disease etiology and severity, as well as endpoints for trials that aim to address the gaps in our knowledge related to identification and management of patients with TR. Standardizing endpoints for trials should provide consistency and enable meaningful comparisons between clinical trials. A second Tricuspid Valve Academic Research Consortium document will focus on further defining trial endpoints and will discuss trial design options.


Sujet(s)
Implantation de valve prothétique cardiaque , Insuffisance tricuspide , Humains , Insuffisance tricuspide/diagnostic , Insuffisance tricuspide/chirurgie , Insuffisance tricuspide/étiologie , Valve atrioventriculaire droite/chirurgie , Implantation de valve prothétique cardiaque/effets indésirables , Résultat thérapeutique , Comorbidité , Cathétérisme cardiaque/effets indésirables , Indice de gravité de la maladie
7.
J Am Coll Cardiol ; 82(17): 1711-1735, 2023 10 24.
Article de Anglais | MEDLINE | ID: mdl-37804294

RÉSUMÉ

Interest in the pathophysiology, etiology, management, and outcomes of patients with tricuspid regurgitation (TR) has grown in the wake of multiple natural history studies showing progressively worse outcomes associated with increasing TR severity, even after adjusting for multiple comorbidities. Historically, isolated tricuspid valve surgery has been associated with high in-hospital mortality rates, leading to the development of transcatheter treatment options. The aim of this first Tricuspid Valve Academic Research Consortium document is to standardize definitions of disease etiology and severity, as well as endpoints for trials that aim to address the gaps in our knowledge related to identification and management of patients with TR. Standardizing endpoints for trials should provide consistency and enable meaningful comparisons between clinical trials. A second Tricuspid Valve Academic Research Consortium document will focus on further defining trial endpoints and will discuss trial design options.


Sujet(s)
Implantation de valve prothétique cardiaque , Insuffisance tricuspide , Humains , Insuffisance tricuspide/diagnostic , Insuffisance tricuspide/chirurgie , Insuffisance tricuspide/étiologie , Valve atrioventriculaire droite/chirurgie , Implantation de valve prothétique cardiaque/effets indésirables , Cathétérisme cardiaque/effets indésirables , Résultat thérapeutique , Indice de gravité de la maladie
8.
J Am Heart Assoc ; 12(17): e029956, 2023 09 05.
Article de Anglais | MEDLINE | ID: mdl-37646214

RÉSUMÉ

Background Left ventricular (LV) global longitudinal strain (GLS) provides incremental prognostic information over LV ejection fraction in patients with heart failure (HF) and secondary mitral regurgitation. We examined the prognostic impact of LV GLS improvement in this population. Methods and Results The COAPT (Cardiovascular Outcomes Assessment of the MitraClip Percutaneous Therapy for Heart Failure Patients With Functional Mitral Regurgitation) trial randomized symptomatic patients with HF with severe (3+/4+) mitral regurgitation to transcatheter edge-to-edge repair with the MitraClip device plus maximally tolerated guideline-directed medical therapy (GDMT) versus GDMT alone. LV GLS was measured at baseline and 6-month follow-up. The relationship between the improvement in LV GLS from baseline to 6 months and the composite of all-cause death or HF hospitalization between 6- and 24-month follow-up were assessed. Among 383 patients, 174 (45.4%) had improved LV GLS at 6-month follow-up (83/195 [42.6%] with transcatheter edge-to-edge repair+GDMT and 91/188 [48.4%] with GDMT alone; P=0.25). Improvement in LV GLS was strongly associated with reduced death or HF hospitalization between 6 and 24 months (P<0.009), with similar risk reduction in both treatment arms (Pinteraction=0.40). By multivariable analysis, LV GLS improvement at 6 months was independently associated with a lower risk of death or HF hospitalization (hazard ratio [HR], 0.55 [95% CI, 0.36-0.83]; P=0.009), death (HR, 0.48 [95% CI, 0.29-0.81]; P=0.006), and HF hospitalization (HR, 0.50 [95% CI, 0.31-0.81]; P=0.005) between 6 and 24 months. Conclusions Among patients with HF and severe mitral regurgitation in the COAPT trial, improvement in LV GLS at 6-month follow-up was associated with improved outcomes after both transcatheter edge-to-edge repair and GDMT alone between 6 and 24 months. Registration URL: https://www.clinicaltrials.gov; Unique identifier: NCT01626079.


Sujet(s)
Défaillance cardiaque , Insuffisance mitrale , Humains , Strain global longitudinal , Défaillance cardiaque/thérapie , Hospitalisation , Insuffisance mitrale/imagerie diagnostique , Insuffisance mitrale/étiologie , Insuffisance mitrale/chirurgie ,
9.
J Am Coll Cardiol ; 82(2): 109-123, 2023 07 11.
Article de Anglais | MEDLINE | ID: mdl-37407110

RÉSUMÉ

BACKGROUND: Previous studies demonstrated transcatheter aortic valve replacement (TAVR) with an earlier generation balloon-expandable valve to be noninferior to surgical aortic valve replacement (SAVR) for death and disabling stroke in intermediate-risk patients with symptomatic, severe aortic stenosis at 5 years. However, limited long-term data are available with the more contemporary SAPIEN 3 (S3) bioprosthesis. OBJECTIVES: The aim of this study was to compare 5-year risk-adjusted outcomes in intermediate-risk patients undergoing S3 TAVR vs SAVR. METHODS: Propensity score matching was performed to account for baseline differences in intermediate-risk patients undergoing S3 TAVR in the PARTNER 2 (Placement of Aortic Transcatheter Valves) S3 single-arm study and SAVR in the PARTNER 2A randomized clinical trial. The primary composite endpoint consisted of 5-year all-cause death and disabling stroke. RESULTS: A total of 783 matched pairs of intermediate-risk patients with severe aortic stenosis were studied. There were no differences in the primary endpoint between S3 TAVR and SAVR at 5 years (40.2% vs 42.7%; HR: 0.87; 95% CI: 0.74-1.03; P = 0.10). The incidence of mild or greater paravalvular regurgitation was more common after S3 TAVR. There were no differences in structural valve deterioration-related stage 2 and 3 hemodynamic valve deterioration or bioprosthetic valve failure. CONCLUSIONS: In this propensity-matched analysis of intermediate-risk patients, 5-year rates of death and disabling stroke were similar between S3 TAVR and SAVR. Rates of structural valve deterioration-related hemodynamic valve deterioration were similar, but paravalvular regurgitation was more common after S3 TAVR. Longer-term follow-up is needed to further evaluate differences in late adverse clinical events and bioprosthetic valve durability. (PII S3i [PARTNER II Trial: Placement of Aortic Transcatheter Valves II - S3 Intermediate], NCT03222128; PII A (PARTNER II Trial: Placement of Aortic Transcatheter Valves II - XT Intermediate and High Risk], NCT01314313).


Sujet(s)
Sténose aortique , Implantation de valve prothétique cardiaque , Prothèse valvulaire cardiaque , Accident vasculaire cérébral , Remplacement valvulaire aortique par cathéter , Humains , Remplacement valvulaire aortique par cathéter/effets indésirables , Implantation de valve prothétique cardiaque/effets indésirables , Sténose aortique/chirurgie , Sténose aortique/étiologie , Résultat thérapeutique , Instruments chirurgicaux , Accident vasculaire cérébral/épidémiologie , Accident vasculaire cérébral/étiologie , Accident vasculaire cérébral/chirurgie
10.
JACC Cardiovasc Interv ; 16(12): 1437-1447, 2023 06 26.
Article de Anglais | MEDLINE | ID: mdl-37380225

RÉSUMÉ

Mitral regurgitation is the most common valvular disease and is estimated to affect over 5 million Americans. Real-world data collection contributes to safety and effectiveness evidence for the U.S. Food and Drug Administration, quality evaluation for the Centers for Medicare and Medicaid Services and hospitals, and clinical best practice research. We aimed to establish a minimum core data set in mitral interventions to promote efficient, reusable real-world data collection for all of these purposes. Two expert task forces separately evaluated and reconciled a list of candidate elements derived from: 1) 2 ongoing transcatheter mitral trials; and 2) a systemic literature review of high-impact mitral trials and U.S multicenter, multidevice registries. From 703 unique data elements considered, unanimous consensus agreement was achieved on 127 "core" data elements, with the most common reasons for exclusion from the minimum core data set being burden or difficulty in accurate assessment (41.2%), duplicative information (25.0%), and low likelihood of affecting outcomes (19.6%). After a systematic review and extensive discussions, a multilateral group of academicians, industry representatives, and regulators established and implemented into the national Society of Thoracic Surgery/American College of Cardiology Transcatheter Valve Therapies Registry 127 interoperable, reusable core data elements to support more efficient, consistent, and informative transcatheter mitral device evidence for regulatory submissions, safety surveillance, best practice development, and hospital quality assessments.


Sujet(s)
Cardiologie , Medicare (USA) , Sujet âgé , Humains , États-Unis , Résultat thérapeutique , Cathéters , , Études multicentriques comme sujet
11.
JACC Cardiovasc Interv ; 16(10): 1160-1172, 2023 05 22.
Article de Anglais | MEDLINE | ID: mdl-37225286

RÉSUMÉ

BACKGROUND: The relationship between left ventricular (LV) remodeling and clinical outcomes after treatment of severe mitral regurgitation (MR) in heart failure (HF) has not been examined. OBJECTIVES: The aim of this study was to evaluate the association between LV reverse remodeling and subsequent outcomes and assess whether transcatheter edge-to-edge repair (TEER) and residual MR are associated with LV remodeling in the COAPT (Cardiovascular Outcomes Assessment of the MitraClip Percutaneous Therapy for Heart Failure Patients With Functional Mitral Regurgitation) trial. METHODS: Patients with HF and severe MR who remained symptomatic on guideline-directed medical therapy (GDMT) were randomized to TEER plus GDMT or GDMT alone. Baseline and 6-month core laboratory measurements of LV end-diastolic volume index and LV end-systolic volume index were examined. Change in LV volumes from baseline to 6 months and clinical outcomes from 6 months to 2 years were evaluated using multivariable regression. RESULTS: The analytical cohort comprised 348 patients (190 treated with TEER, 158 treated with GDMT alone). A decrease in LV end-diastolic volume index at 6 months was associated with reduced cardiovascular death between 6 months and 2 years (adjusted HR: 0.90 per 10 mL/m2 decrease; 95% CI: 0.81-1.00; P = 0.04), with consistent results in both treatment groups (Pinteraction = 0.26). Directionally similar but nonsignificant relationships were present for all-cause death and HF hospitalization and between reduced LV end-systolic volume index and all outcomes. Neither treatment group nor MR severity at 30 days was associated with LV remodeling at 6 or 12 months. The treatment benefits of TEER were not significant regardless of the degree of LV remodeling at 6 months. CONCLUSIONS: In patients with HF and severe MR, LV reverse remodeling at 6 months was associated with subsequently improved 2-year outcomes but was not affected by TEER or the extent of residual MR. (Cardiovascular Outcomes Assessment of the MitraClip Percutaneous Therapy for Heart Failure Patients With Functional Mitral Regurgitation [The COAPT Trial] and COAPT CAS [COAPT]; NCT01626079).


Sujet(s)
Défaillance cardiaque , Insuffisance mitrale , Humains , Remodelage ventriculaire , Insuffisance mitrale/imagerie diagnostique , Insuffisance mitrale/chirurgie , Résultat thérapeutique , Défaillance cardiaque/imagerie diagnostique , Défaillance cardiaque/thérapie , Collecte de données
12.
J Am Coll Cardiol ; 81(8): 743-752, 2023 02 28.
Article de Anglais | MEDLINE | ID: mdl-36813373

RÉSUMÉ

BACKGROUND: The extent of extravalvular cardiac damage is associated with increased risk of adverse events among patients with severe aortic stenosis undergoing aortic valve replacement (AVR). OBJECTIVES: The goal was to describe the association of cardiac damage on health status before and after AVR. METHODS: Patients from the PARTNER (Placement of Aortic Transcatheter Valves) 2 and 3 trials were pooled and classified by echocardiographic cardiac damage stage at baseline and 1 year as previously described (stage 0-4). We examined the association between baseline cardiac damage and 1-year health status (assessed by the Kansas City Cardiomyopathy Questionnaire Overall Score [KCCQ-OS]). RESULTS: Among 1,974 patients (794 surgical AVR, 1,180 transcatheter AVR), the extent of cardiac damage at baseline was associated with lower KCCQ scores both at baseline and at 1 year after AVR (P < 0.0001) and with increased rates of a poor outcome (death, KCCQ-OS <60, or a decrease in KCCQ-OS of ≥10 points) at 1 year (stages 0-4: 10.6% vs 19.6% vs 29.0% vs 44.7% vs 39.8%; P < 0.0001). In a multivariable model, each 1-stage increase in baseline cardiac damage was associated with a 24% increase in the odds of a poor outcome (95% CI: 9%-41%; P = 0.001). Change in stage of cardiac damage at 1 year after AVR was associated with the extent of improvement in KCCQ-OS over the same period (mean change in 1-year KCCQ-OS: improvement of ≥1 stage +26.8 [95% CI: 24.2-29.4] vs no change +21.4 [95% CI: 20.0-22.7] vs deterioration of ≥1 stage +17.5 [95% CI: 15.4-19.5]; P < 0.0001). CONCLUSIONS: The extent of cardiac damage before AVR has an important impact on health status outcomes, both cross-sectionally and after AVR. (PARTNER II Trial: Placement of AoRTic TraNscathetER Valves II - XT Intermediate and High Risk (PII A), NCT01314313; The PARTNER II Trial: Placement of AoRTic TraNscathetER Valves - PII B [PARTNERII B], NCT02184442; PARTNER 3 Trial: Safety and Effectiveness of the SAPIEN 3 Transcatheter Heart Valve in Low Risk Patients With Aortic Stenosis [P3], NCT02675114).


Sujet(s)
Sténose aortique , Implantation de valve prothétique cardiaque , Remplacement valvulaire aortique par cathéter , Humains , Valve aortique/chirurgie , Qualité de vie , Résultat thérapeutique , État de santé , Sténose aortique/chirurgie , Facteurs de risque , Indice de gravité de la maladie
13.
Eur Heart J ; 44(10): 836-852, 2023 03 07.
Article de Anglais | MEDLINE | ID: mdl-36660821

RÉSUMÉ

AIMS: Additional randomized clinical trial (RCT) data comparing transcatheter aortic valve implantation (TAVI) with surgical aortic valve replacement (SAVR) is available, including longer term follow-up. A meta-analysis comparing TAVI to SAVR was performed. A pragmatic risk classification was applied, partitioning lower-risk and higher-risk patients. METHODS AND RESULTS: The main endpoints were death, strokes, and the composite of death or disabling stroke, occurring at 1 year (early) or after 1 year (later). A random-effects meta-analysis was performed. Eight RCTs with 8698 patients were included. In lower-risk patients, at 1 year, the risk of death was lower after TAVI compared with SAVR [relative risk (RR) 0.67; 95% confidence interval (CI) 0.47 to 0.96, P = 0.031], as was death or disabling stroke (RR 0.68; 95% CI 0.50 to 0.92, P = 0.014). There were no differences in strokes. After 1 year, in lower-risk patients, there were no significant differences in all main outcomes. In higher-risk patients, there were no significant differences in main outcomes. New-onset atrial fibrillation, major bleeding, and acute kidney injury occurred less after TAVI; new pacemakers, vascular complications, and paravalvular leak occurred more after TAVI. CONCLUSION: In lower-risk patients, there was an early mortality reduction with TAVI, but no differences after later follow-up. There was also an early reduction in the composite of death or disabling stroke, with no difference at later follow-up. There were no significant differences for higher-risk patients. Informed therapy decisions may be more dependent on the temporality of events or secondary endpoints than the long-term occurrence of main clinical outcomes.


Sujet(s)
Sténose aortique , Implantation de valve prothétique cardiaque , Accident vasculaire cérébral , Humains , Valve aortique/chirurgie , Implantation de valve prothétique cardiaque/méthodes , Résultat thérapeutique , Essais contrôlés randomisés comme sujet , Facteurs de risque , Accident vasculaire cérébral/épidémiologie , Accident vasculaire cérébral/étiologie
14.
JACC Cardiovasc Interv ; 15(18): 1823-1833, 2022 09 26.
Article de Anglais | MEDLINE | ID: mdl-36137685

RÉSUMÉ

BACKGROUND: Physiologic right ventricle-pulmonary artery (RV-PA) coupling may be impaired in patients with aortic stenosis (AS). OBJECTIVES: This study aimed to assess the incidence and prognostic significance of impaired RV-PA coupling in low-risk patients with symptomatic severe AS undergoing transcatheter aortic valve replacement or surgical aortic valve replacement. METHODS: RV-PA coupling was measured by transthoracic echocardiography as the ratio of tricuspid annular plane systolic excursion (TAPSE) to pulmonary artery systolic pressure (PASP) in patients in the PARTNER (Placement of Aortic Transcatheter Valve) 3 trial. The primary endpoint was the composite of all-cause mortality, stroke, and rehospitalization at the 2-year follow-up. RESULTS: Among 570 low-risk patients included in the analysis, RV-PA uncoupling was defined by a TAPSE/PASP ratio ≤ 0.55 mm/mm Hg. At baseline, 222 of 570 (38.9%) patients had RV-PA uncoupling. At 2 years, patients with baseline RV-PA uncoupling had an increased incidence of the primary endpoint (19.1% vs 9.9%, P = 0.002), all-cause mortality (5.9% vs 0.6%, P < 0.001), cardiovascular mortality (4.1% vs 0.6%, P = 0.003), and rehospitalization (13.5% vs 7.3%, P = 0.018). On multivariable analysis, baseline RV-PA uncoupling remained an independent predictor of the primary endpoint at 2 years (HR: 1.92; 95% CI: 1.04-3.57; P = 0.038). CONCLUSIONS: In patients with symptomatic severe AS at low surgical risk undergoing transcatheter aortic valve replacement or surgical aortic valve replacement, baseline RV-PA uncoupling defined by TAPSE/PASP ≤ 0.55 mm Hg was associated with adverse clinical outcomes at 2 years, including all-cause mortality, cardiovascular mortality, and rehospitalization.


Sujet(s)
Sténose aortique , Dysfonction ventriculaire droite , Humains , Sténose aortique/complications , Sténose aortique/imagerie diagnostique , Sténose aortique/chirurgie , Ventricules cardiaques , Artère pulmonaire/imagerie diagnostique , Résultat thérapeutique , Fonction ventriculaire droite
15.
JAMA Cardiol ; 7(9): 934-944, 2022 09 01.
Article de Anglais | MEDLINE | ID: mdl-35895046

RÉSUMÉ

Importance: In patients with severe aortic stenosis and left ventricular ejection fraction (LVEF) less than 50%, early LVEF improvement after transcatheter aortic valve replacement (TAVR) is associated with improved 1-year mortality; however, its association with long-term clinical outcomes is not known. Objective: To examine the association between early LVEF improvement after TAVR and 5-year outcomes. Design, Setting, and Participants: This cohort study analyzed patients enrolled in the Placement of Aortic Transcatheter Valves (PARTNER) 1, 2, and S3 trials and registries between July 2007 and April 2015. High- and intermediate-risk patients with baseline LVEF less than 50% who underwent transfemoral TAVR were included in the current study. Data were analyzed from August 2020 to May 2021. Exposures: Early LVEF improvement, defined as increase of 10 percentage points or more at 30 days and also as a continuous variable (ΔLVEF between baseline and 30 days). Main Outcomes and Measures: All-cause death at 5 years. Results: Among 659 included patients with LVEF less than 50%, 468 (71.0%) were male, and the mean (SD) age was 82.4 (7.7) years. LVEF improvement within 30 days following transfemoral TAVR occurred in 216 patients (32.8%) (mean [SD] ΔLVEF, 16.4 [5.7%]). Prior myocardial infarction, diabetes, cancer, higher baseline LVEF, larger left ventricular end-diastolic diameter, and larger aortic valve area were independently associated with lower likelihood of LVEF improvement. Patients with vs without early LVEF improvement after TAVR had lower 5-year all-cause death (102 [50.0%; 95% CI, 43.3-57.1] vs 246 [58.4%; 95% CI, 53.6-63.2]; P = .04) and cardiac death (52 [29.5%; 95% CI, 23.2-37.1] vs 135 [38.1%; 95% CI, 33.1-43.6]; P = .05). In multivariable analyses, early improvement in LVEF (modeled as a continuous variable) was associated with lower 5-year all-cause death (adjusted hazard ratio per 5% increase in LVEF, 0.94 [95% CI, 0.88-1.00]; P = .04) and cardiac death (adjusted hazard ratio per 5% increase in LVEF, 0.90 [95% CI, 0.82-0.98]; P = .02) after TAVR. Restricted cubic spline analysis demonstrated a visual inflection point at ΔLVEF of 10% beyond which there was a steep decline in all-cause mortality with increasing degree of LVEF improvement. There were no statistically significant differences in rehospitalization, New York Heart Association functional class, or Kansas City Cardiomyopathy Questionnaire Overall Summary score at 5 years in patients with vs without early LVEF improvement. In subgroup analysis, the association between early LVEF improvement and 5-year all-cause death was consistent regardless of the presence or absence of coronary artery disease or prior myocardial infarction. Conclusions and Relevance: In patients with severe aortic stenosis and LVEF less than 50%, 1 in 3 experience LVEF improvement within 1 month after TAVR. Early LVEF improvement is associated with lower 5-year all-cause and cardiac death.


Sujet(s)
Sténose aortique , Infarctus du myocarde , Remplacement valvulaire aortique par cathéter , Sujet âgé de 80 ans ou plus , Études de cohortes , Mort , Femelle , Humains , Mâle , Infarctus du myocarde/chirurgie , Débit systolique , Fonction ventriculaire gauche
16.
J Am Coll Cardiol ; 80(8): 783-800, 2022 08 23.
Article de Anglais | MEDLINE | ID: mdl-35595203

RÉSUMÉ

BACKGROUND: The impact of aortic valve replacement (AVR) on progression/regression of extravalvular cardiac damage and its association with subsequent prognosis is unknown. OBJECTIVES: The purpose of this study was to describe the evolution of cardiac damage post-AVR and its association with outcomes. METHODS: Patients undergoing transcatheter or surgical AVR from the PARTNER (Placement of Aortic Transcatheter Valves) 2 and 3 trials were pooled and classified by cardiac damage stage at baseline and 1 year (stage 0, no damage; stage 1, left ventricular damage; stage 2, left atrial or mitral valve damage; stage 3, pulmonary vasculature or tricuspid valve damage; and stage 4, right ventricular damage). Proportional hazards models determined association between change in cardiac damage post-AVR and 2-year outcomes. RESULTS: Among 1,974 patients, 121 (6.1%) were stage 0, 287 (14.5%) stage 1, 1,014 (51.4%) stage 2, 412 (20.9%) stage 3, and 140 (7.1%) stage 4 pre-AVR. Two-year mortality was associated with extent of cardiac damage at baseline and 1 year. Compared with baseline, cardiac damage improved in ∼15%, remained unchanged in ∼60%, and worsened in ∼25% of patients at 1 year. The 1-year change in cardiac damage stage was independently associated with mortality (adjusted HR for improvement: 0.49; no change: 1.00; worsening: 1.95; P = 0.023) and composite of death or heart failure hospitalization (adjusted HR for improvement: 0.60; no change: 1.00; worsening: 2.25; P < 0.001) at 2 years. CONCLUSIONS: In patients undergoing AVR, extent of extravalvular cardiac damage at baseline and its change at 1 year have important prognostic implications. These findings suggest that earlier detection of aortic stenosis and intervention before development of irreversible cardiac damage may improve global cardiac function and prognosis. (PARTNER II Trial: Placement of AoRTic TraNscathetER Valves II - XT Intermediate and High Risk [PII A], NCT01314313; The PARTNER II Trial: Placement of AoRTic TraNscathetER Valves - PII B [PARTNERII B], NCT02184442; and PARTNER 3 Trial: Safety and Effectiveness of the SAPIEN 3 Transcatheter Heart Valve in Low Risk Patients With Aortic Stenosis [P3], NCT02675114).


Sujet(s)
Sténose aortique , Implantation de valve prothétique cardiaque , Prothèse valvulaire cardiaque , Remplacement valvulaire aortique par cathéter , Valve aortique/chirurgie , Sténose aortique/diagnostic , Prothèse valvulaire cardiaque/effets indésirables , Implantation de valve prothétique cardiaque/effets indésirables , Humains , Pronostic , Facteurs de risque , Indice de gravité de la maladie , Remplacement valvulaire aortique par cathéter/effets indésirables , Résultat thérapeutique
17.
Ann Thorac Surg ; 113(5): 1730-1742, 2022 05.
Article de Anglais | MEDLINE | ID: mdl-35367049

RÉSUMÉ

Transcatheter aortic valve replacement (TAVR) is the standard of care for severe, symptomatic aortic stenosis. Real-world TAVR data collection contributes to benefit/risk assessment and safety evidence for the U.S. Food and Drug Administration, quality evaluation for the Centers for Medicare and Medicaid Services and hospitals, as well as clinical research and real-world implementation through appropriate use criteria. The essential minimum core dataset for these purposes has not previously been defined but is necessary to promote efficient, reusable real-world data collection supporting quality, regulatory, and clinical applications. The authors performed a systematic review of the published research for high-impact TAVR studies and U.S. multicenter, multidevice registries. Two expert task forces, one from the Predictable and Sustainable Implementation of National Cardiovascular Registries/Heart Valve Collaboratory and another from The Society of Thoracic Surgeons/American College of Cardiology TVT (Transcatheter Valve Therapy) Registry convened separately and then met to reconcile a final list of essential data elements. From 276 unique data elements considered, unanimous consensus agreement was achieved on 132 "core" data elements, with the most common reasons for exclusion from the minimum core dataset being burden or difficulty in accurate assessment (36.9%), duplicative information (33.3%), and low likelihood of affecting outcomes (10.7%). After a systematic review and extensive discussions, a multilateral group of academicians, industry representatives, and regulators established 132 interoperable, reusable essential core data elements essential to supporting more efficient, consistent, and informative TAVR device evidence for regulatory submissions, safety surveillance, best practice, and hospital quality assessments.


Sujet(s)
Sténose aortique , Remplacement valvulaire aortique par cathéter , Sujet âgé , Valve aortique/chirurgie , Sténose aortique/diagnostic , Sténose aortique/chirurgie , Humains , Medicare (USA) , Études multicentriques comme sujet , Enregistrements , Facteurs de risque , Facteurs temps , Résultat thérapeutique , États-Unis
18.
JACC Cardiovasc Interv ; 15(7): 685-697, 2022 04 11.
Article de Anglais | MEDLINE | ID: mdl-35367168

RÉSUMÉ

Transcatheter aortic valve replacement (TAVR) is the standard of care for severe, symptomatic aortic stenosis. Real-world TAVR data collection contributes to benefit/risk assessment and safety evidence for the U.S. Food and Drug Administration, quality evaluation for the Centers for Medicare and Medicaid Services and hospitals, as well as clinical research and real-world implementation through appropriate use criteria. The essential minimum core dataset for these purposes has not previously been defined but is necessary to promote efficient, reusable real-world data collection supporting quality, regulatory, and clinical applications. The authors performed a systematic review of the published research for high-impact TAVR studies and U.S. multicenter, multidevice registries. Two expert task forces, one from the Predictable and Sustainable Implementation of National Cardiovascular Registries/Heart Valve Collaboratory and another from The Society of Thoracic Surgeons/American College of Cardiology TVT (Transcatheter Valve Therapy) Registry convened separately and then met to reconcile a final list of essential data elements. From 276 unique data elements considered, unanimous consensus agreement was achieved on 132 "core" data elements, with the most common reasons for exclusion from the minimum core dataset being burden or difficulty in accurate assessment (36.9%), duplicative information (33.3%), and low likelihood of affecting outcomes (10.7%). After a systematic review and extensive discussions, a multilateral group of academicians, industry representatives, and regulators established 132 interoperable, reusable essential core data elements essential to supporting more efficient, consistent, and informative TAVR device evidence for regulatory submissions, safety surveillance, best practice, and hospital quality assessments.


Sujet(s)
Sténose aortique , Remplacement valvulaire aortique par cathéter , Sujet âgé , Valve aortique/imagerie diagnostique , Valve aortique/chirurgie , Sténose aortique/imagerie diagnostique , Sténose aortique/chirurgie , Humains , Medicare (USA) , Études multicentriques comme sujet , Enregistrements , Facteurs de risque , Facteurs temps , Remplacement valvulaire aortique par cathéter/effets indésirables , Résultat thérapeutique , États-Unis
19.
Catheter Cardiovasc Interv ; 99(6): 1877-1885, 2022 05.
Article de Anglais | MEDLINE | ID: mdl-35289473

RÉSUMÉ

OBJECTIVES: The purpose of this study is to investigate the viability of transcatheter aortic valve replacement (TAVR) for severe symptomatic aortic stenosis (AS) in patients with prior chest radiation therapy (cXRT). BACKGROUND: Since patients with prior cXRT perform poorly with surgical aortic valve replacement, TAVR can be a viable alternative. However, clinical outcomes after TAVR in this patient population have not been well studied. METHODS: From the pooled registry of the placement of aortic transcatheter valves II trial, we identified patients with and without prior cXRT who underwent TAVR (n = 64 and 3923, respectively). The primary outcome was a composite of all-cause death and any stroke at 2 years. Time to event analyses were shown as Kaplan-Meier event rates and compared by log-rank testing. Hazard ratios (HRs) were estimated and compared by Cox proportional hazards regression model. RESULTS: There was no significant difference in the primary outcome between the patients with and without prior cXRT (30.7% vs. 27.0%; p = 0.75; HR, 1.08; 95% confidence interval, 0.66-1.77). Rates of myocardial infarction, vascular complications, acute kidney injury, or new pacemaker implant after TAVR were not statistically different between the two groups. The rate of immediate reintervention with a second valve for aortic regurgitation after TAVR was higher among the patients with prior cXRT. However, no further difference was observed during 2 years follow-up after discharge from the index-procedure hospitalization. CONCLUSIONS: TAVR is a viable alternative for severe symptomatic AS in patients who had cXRT in the past.


Sujet(s)
Sténose aortique , Implantation de valve prothétique cardiaque , Prothèse valvulaire cardiaque , Remplacement valvulaire aortique par cathéter , Valve aortique/imagerie diagnostique , Valve aortique/chirurgie , Sténose aortique/imagerie diagnostique , Sténose aortique/épidémiologie , Sténose aortique/chirurgie , Implantation de valve prothétique cardiaque/effets indésirables , Humains , Facteurs de risque , Remplacement valvulaire aortique par cathéter/effets indésirables , Remplacement valvulaire aortique par cathéter/méthodes , Résultat thérapeutique
20.
Circ Cardiovasc Interv ; 15(1): e011375, 2022 01.
Article de Anglais | MEDLINE | ID: mdl-35041454

RÉSUMÉ

BACKGROUND: Randomized trials have shown short- and mid-term benefits with transcatheter versus surgical aortic valve replacement (TAVR versus SAVR) for patients at intermediate or low-risk for surgery. Frailty and prefrailty could explain some of this benefit due to an impaired ability to recover fully from a major surgical procedure. METHODS: We examined 2-year outcomes (survival and Kansas City Cardiomyopathy Questionnaire [KCCQ] scores) among patients at intermediate or low surgical risk treated with transfemoral-TAVR or SAVR within the PARTNER (Placement of Aortic Transcatheter Valves) 2A trial, SAPIEN 3 intermediate-risk registry, and PARTNER 3 trial. Frailty was examined as a continuous variable based on grip strength, gait speed, serum albumin, and activities of daily living. We tested the interaction of frailty markers by treatment (TAVR versus SAVR) in proportional hazards regression models (survival) and piecewise linear regression models (KCCQ), adjusting for patient demographic and clinical factors. RESULTS: Among the 3025 patients in the analytic cohort (2003 TAVR, 1022 SAVR; mean age 79.3 years, 61.6% men), 799 (26.4%) were nonfrail, 2041 (67.5%) were prefrail (1-2 frailty markers), and 185 (6.1%) were frail (3-4 frailty markers). Increasing frailty (none versus prefrail versus frail) was associated with higher 2-year mortality (5.5% versus 11.1% versus 22.8%; log-rank P<0.001) and worse 2-year health status among survivors (KCCQ scores adjusted for baseline: 84.8 versus 79.6 versus 77.4, P<0.001). In multivariable models, there were no significant interactions between frailty markers and treatment group for either survival (interaction P=0.39) or health status (interaction P>0.47 for all time points). CONCLUSIONS: In a cohort of older patients with severe aortic stenosis who were at low or intermediate surgical risk, increasing frailty markers were associated with worse 2-year mortality and greater health status impairment after either TAVR or SAVR, but there were no significant interactions between type of valve replacement and frailty with respect to either outcome.


Sujet(s)
Sténose aortique , Fragilité , Implantation de valve prothétique cardiaque , Remplacement valvulaire aortique par cathéter , Activités de la vie quotidienne , Sujet âgé , Valve aortique/chirurgie , Sténose aortique/chirurgie , Essais cliniques comme sujet , Femelle , Fragilité/diagnostic , Implantation de valve prothétique cardiaque/effets indésirables , Implantation de valve prothétique cardiaque/méthodes , Humains , Mâle , Facteurs de risque , Indice de gravité de la maladie , Remplacement valvulaire aortique par cathéter/effets indésirables , Résultat thérapeutique
SÉLECTION CITATIONS
DÉTAIL DE RECHERCHE
...