Your browser doesn't support javascript.
loading
Montrer: 20 | 50 | 100
Résultats 1 - 2 de 2
Filtrer
Plus de filtres











Base de données
Gamme d'année
1.
Clin Ophthalmol ; 17: 71-83, 2023.
Article de Anglais | MEDLINE | ID: mdl-36636622

RÉSUMÉ

Purpose: To provide expert consensus and evidence-based current guidelines on treatment technique, postoperative care, expected outcomes and retreatment for MicroPulse Transscleral Laser Treatment (TLT). Methods: A comprehensive search of PubMed led to the identification and analysis of 61 studies on MicroPulse TLT. To provide guidance in areas where there was not enough available literature, a three-round Delphi method was conducted involving 10 international experts in MicroPulse TLT. Results: The response rate was 70% in the first round, 70% in the second round, and 80% in the third round of the Delphi method. Once all responses were aggregated, a live meeting was held with 90% attendance, and consensus was achieved on each of the findings detailed in this manuscript. Conclusion: Used within appropriate treatment parameters, with proper technique and patient selection, MicroPulse TLT is a safe and effective treatment for many types and severities of glaucoma. MicroPulse TLT represents a useful addition to the glaucoma armamentarium.

2.
Clin Ophthalmol ; 16: 1837-1846, 2022.
Article de Anglais | MEDLINE | ID: mdl-35698599

RÉSUMÉ

Purpose: To provide consensus-based current guidelines on optimal dosimetry and patient selection for MicroPulse Transscleral Laser Therapy (TLT) based on a review of the literature and a Delphi method. Methods: A comprehensive search of Pub Med led to the identification and analysis of 61 studies on MicroPulse TLT that contained information on laser settings and patient selection. To determine consensus in areas where there was not enough available literature, a three-round Delphi method was conducted. Results: The response rate was 90% in the first round, 90% in the second round, and 80% in the third round of the Delphi technique. Once all responses were aggregated, a live meeting was held with 80% attendance, and consensus was achieved on each of the findings detailed in this manuscript. Conclusion: Micropulse TLT is a useful addition to the glaucoma armamentarium. When used with proper surgical technique at energy settings within the boundaries described in this manuscript, MicroPulse TLT is a safe and effective treatment for many types and stages of glaucoma. Based on current knowledge and experience, the consensus recommendation of this expert panel is that the standard MicroPulse TLT settings using the revised MicroPulse P3 Probe should be 2500 mW, 31.3% duty cycle, and 4 sweeps at a sweep velocity of 20 seconds each per hemisphere. Both hemispheres avoiding the 3 and 9 clock hours should be treated. The panel also reached consensus on patient selection for MicroPulse TLT providing guidance for the use of the procedure.

SÉLECTION CITATIONS
DÉTAIL DE RECHERCHE