Your browser doesn't support javascript.
loading
Montrer: 20 | 50 | 100
Résultats 1 - 6 de 6
Filtrer
Plus de filtres










Base de données
Gamme d'année
1.
Biomed Microdevices ; 7(2): 147-52, 2005 Jun.
Article de Anglais | MEDLINE | ID: mdl-15940430

RÉSUMÉ

We have developed an integrated hydrogenated amorphous silicon (a-Si:H) fluorescence detector for microfluidic genetic analysis. It consists of a half-ball lens, a ZnS/YF3 multilayer optical interference filter with a pinhole, and an annular a-Si:H PIN photodiode allowing the laser excitation to pass up through the central aperture in the photodiode and the filter. Microfluidic separations of multiplex PCR products generated from methicillin-resistant/sensitive Staphylococcus aureus (MRSA/MSSA) DNA on microfluidic capillary electrophoresis (CE) devices are successfully detected with the integrated detector. Similarly, multiplex PCR amplicons from the kanamycin resistant and K12 serotype-specific genes of E. coli cells are detected. The direct detection of multiplex PCR amplicons indicates that the fluorescence detector can be successfully coupled with current microfluidic PCR-CE platforms. This work establishes that the integrated a-Si:H detector provides relevant limits of detection for point-of-care genetic and pathogen analysis with microfluidic devices.


Sujet(s)
ADN bactérien/analyse , ADN bactérien/génétique , Électrophorèse capillaire/instrumentation , Techniques d'analyse microfluidique/instrumentation , Réaction de polymérisation en chaîne/instrumentation , Analyse de séquence d'ADN/instrumentation , Spectrométrie de fluorescence/instrumentation , Électrophorèse capillaire/méthodes , Conception d'appareillage , Analyse de panne d'appareillage , Hydrogénation , Techniques d'analyse microfluidique/méthodes , Réaction de polymérisation en chaîne/méthodes , Analyse de séquence d'ADN/méthodes , Silicium , Spectrométrie de fluorescence/méthodes , Intégration de systèmes , Transducteurs
2.
Anal Chem ; 76(11): 3162-70, 2004 Jun 01.
Article de Anglais | MEDLINE | ID: mdl-15167797

RÉSUMÉ

An integrated portable genetic analysis microsystem including PCR amplification and capillary electrophoretic (CE) analysis coupled with a compact instrument for electrical control and laser-excited fluorescence detection has been developed. The microdevice contains microfabricated heaters, temperature sensors, and membrane valves to provide controlled sample positioning and immobilization in 200-nL PCR chambers. The instrument incorporates a solid-state laser and confocal fluorescence detection optics, electronics for sensing and powering the PCR reactor, and high-voltage power supplies for conducting CE separations. The fluorescein-labeled PCR products are amplified and electrophoretically analyzed in a gel-filled microchannel in <10 min. We demonstrate the utility of this instrument by performing pathogen detection and genotyping directly from whole Escherichia coli and Staphylococcus aureus cells. The E. coli detection assay consists of a triplex PCR amplification targeting genes that encode 16S ribosomal RNA, the fliC flagellar antigen, and the sltI shigatoxin. Serial dilution demonstrates a limit of detection of 2-3 bacterial cells. The S. aureus assay uses a femA marker to identify cells as S. aureus and a mecA marker to probe for methicillin resistance. This integrated portable genomic analysis microsystem demonstrates the feasibility of performing rapid high-quality detection of pathogens and their antimicrobial drug resistance.


Sujet(s)
Bactéries/isolement et purification , Infections bactériennes/diagnostic , Électrophorèse capillaire/méthodes , Séquençage par oligonucléotides en batterie/méthodes , Réaction de polymérisation en chaîne/méthodes , Animaux , Bactéries/génétique , Séquence nucléotidique , Infections à Escherichia coli/diagnostic , Données de séquences moléculaires , Infections à staphylocoques/diagnostic
3.
Electrophoresis ; 22(18): 3845-56, 2001 Oct.
Article de Anglais | MEDLINE | ID: mdl-11700713

RÉSUMÉ

This review focuses on some recent advances in realizing microfabricated capillary array electrophoresis (microCAE). In particular, the development of a novel rotary scanning confocal fluorescence detector has facilitated the high-speed collection of sequencing and genotyping data from radially formatted microCAE devices. The concomitant development of a convenient energy-transfer cassette labeling chemistry allows sensitive multicolor labeling of any DNA genotyping or sequencing analyte. High-performance hereditary haemochromatosis and short tandem repeat genotyping assays are demonstrated on these devices along with rapid mitochondrial DNA sequence polymorphism analysis. Progress in supporting technology such as robotic fluid dispensing and batched data analysis is also presented. The ultimate goal is to develop a parallel analysis platform capable of integrated sample preparation and automated electrophoretic analysis with a throughput 10-100 times that of current technology.


Sujet(s)
Électrophorèse capillaire , Techniques génétiques , Protéines membranaires , Microchimie/méthodes , Électrophorèse capillaire/instrumentation , Électrophorèse capillaire/méthodes , Conception d'appareillage , Colorants fluorescents/analyse , Fluorimétrie/instrumentation , Fluorimétrie/méthodes , Techniques génétiques/instrumentation , Génome humain , Génotype , Antigènes HLA/génétique , Hémochromatose/génétique , Protéine de l'hémochromatose , Antigènes d'histocompatibilité de classe I/génétique , Humains , Lasers , Microchimie/instrumentation , Polymorphisme de nucléotide simple , Analyse de séquence d'ADN/instrumentation , Analyse de séquence d'ADN/méthodes
4.
Science ; 287(5461): 2185-95, 2000 Mar 24.
Article de Anglais | MEDLINE | ID: mdl-10731132

RÉSUMÉ

The fly Drosophila melanogaster is one of the most intensively studied organisms in biology and serves as a model system for the investigation of many developmental and cellular processes common to higher eukaryotes, including humans. We have determined the nucleotide sequence of nearly all of the approximately 120-megabase euchromatic portion of the Drosophila genome using a whole-genome shotgun sequencing strategy supported by extensive clone-based sequence and a high-quality bacterial artificial chromosome physical map. Efforts are under way to close the remaining gaps; however, the sequence is of sufficient accuracy and contiguity to be declared substantially complete and to support an initial analysis of genome structure and preliminary gene annotation and interpretation. The genome encodes approximately 13,600 genes, somewhat fewer than the smaller Caenorhabditis elegans genome, but with comparable functional diversity.


Sujet(s)
Drosophila melanogaster/génétique , Génome , Analyse de séquence d'ADN , Animaux , Transport biologique/génétique , Chromatine/génétique , Clonage moléculaire , Biologie informatique , Cartographie de contigs , Cytochrome P-450 enzyme system/génétique , Réparation de l'ADN/génétique , Réplication de l'ADN/génétique , Drosophila melanogaster/métabolisme , Euchromatine , Banque de gènes , Gènes d'insecte , Hétérochromatine/génétique , Protéines d'insecte/composition chimique , Protéines d'insecte/génétique , Protéines d'insecte/physiologie , Protéines nucléaires/génétique , Biosynthèse des protéines , Transcription génétique
5.
J Hered ; 89(6): 531-7, 1998.
Article de Anglais | MEDLINE | ID: mdl-9864863

RÉSUMÉ

Hereditary canine spinal muscular atrophy (HCSMA) is an autosomal dominant motor neuron disease that is similar in pathology and clinical presentation to various forms of human motor neuron disease. We have tested the hypothesis that the canine survival motor neuron (SMN) gene is responsible for HCSMA by genetic and molecular analysis of a colony of mixed breed dogs, all descended from a single affected individual. We cloned the canine SMN gene and determined the DNA sequence in an affected and an unaffected dog. We found no germline mutations in the SMN gene of the affected individual. Using conventional linkage analysis with canine-specific microsatellite repeat markers we screened the canine genome and identified a single linkage group likely to contain the HCSMA gene. Analysis with a panel of canine/rodent hybrid cell lines revealed that the SMN gene did not map to the same chromosome as the HCSMA linkage group. Collectively these results suggest that the molecular basis for HCSMA is distinct from that of phenotypically similar human disorders caused by inherited mutations in the SMN gene. This further suggests that additional studies on the molecular nature of HCSMA may reveal an unknown element of the molecular pathway leading to motor neuron disease.


Sujet(s)
Maladies des chiens/génétique , Amyotrophie spinale/médecine vétérinaire , Séquence d'acides aminés , Animaux , Séquence nucléotidique , Cartographie chromosomique , Clonage moléculaire , Protéine de liaison à l'élément de réponse à l'AMP cyclique , Amorces ADN , Chiens , Femelle , Liaison génétique , Mutation germinale , Humains , Mâle , Données de séquences moléculaires , Amyotrophie spinale/génétique , Protéines de tissu nerveux/génétique , Pedigree , Protéines de liaison à l'ARN , Protéines du complexe SMN , Similitude de séquences d'acides aminés
SÉLECTION CITATIONS
DÉTAIL DE RECHERCHE
...