Your browser doesn't support javascript.
loading
Montrer: 20 | 50 | 100
Résultats 1 - 20 de 402
Filtrer
1.
Circ Cardiovasc Qual Outcomes ; : e010877, 2024 Aug 30.
Article de Anglais | MEDLINE | ID: mdl-39212048

RÉSUMÉ

BACKGROUND: Arrhythmia recurrence after pulmonary vein isolation (PVI) is common. We conducted a multicenter, randomized trial to determine the impact of increased physical activity on atrial fibrillation recurrence after PVI. METHODS: From 2018 to 2020, we randomly assigned 200 patients with atrial fibrillation to the ACTION or NO-ACTION group in 4 different centers in the local country of Brandenburg, Germany. Patients were eligible if they were scheduled to undergo PVI, aged ≥50 to ≤77 years, body mass index ≥23 to ≤35 kg/m2, and accepted wearing an activity tracker allowing 24-hour activity monitoring via mobile app. Patients in the ACTION group were actively remote-controlled via transmitted activity data by a physiotherapist, and individual motivational interviewing call sessions were scheduled with each ACTION patient every 2 weeks. The primary end point was the composite of recurrence of any atrial arrhythmia >30 seconds, additional ablation procedure, cardioversion, and new onset of antiarrhythmic drugs earliest after 90 days after index PVI over 12 months. RESULTS: Overall, the median age of patients was 66 (interquartile range, 61-71) years, 33.5% were women, and 52% had persistent atrial fibrillation. The number of steps per day increased in both groups of patients from baseline to 12 months (P<0.001). The absolute increase in steps per day did not differ between patients in the ACTION group with +3205 steps (597-4944) compared with those in the NO-ACTION group +2423 steps (17-4284), P=0.325. Unadjusted intention-to-treat analysis showed no difference in the primary composite end point in the ACTION group (27.3%) versus the NO-ACTION group (32.7%), P=0.405. CONCLUSIONS: Physical activity improved in patients after PVI. The present randomized controlled trial shows that activity tracker and motivational calls to increase physical activity versus activity tracker alone did not reduce the occurrence of the primary composite end point of atrial fibrillation recurrence or the absolute increase in steps per day. REGISTRATION: URL: https://www.cochranelibrary.com; Unique identifier: DRKS00012914.

2.
Article de Anglais | MEDLINE | ID: mdl-39128016

RÉSUMÉ

OBJECTIVES: We investigated the sex-related difference in characteristics and 2-year outcomes after surgical aortic valve replacement (SAVR) by propensity-score matching (PSM). METHODS: Data from 2 prospective registries, the INSPIRIS RESILIA Durability Registry (INDURE) and IMPACT, were merged, resulting in a total of 933 patients: 735 males and 253 females undergoing first-time SAVR. The PSM was performed to assess the impact of sex on the SAVR outcomes, yielding 433 males and 243 females with comparable baseline characteristics. RESULTS: Females had a lower body mass index (median 27.1 vs 28.0 kg/m2; P = 0.008), fewer bicuspid valves (52% vs 59%; P = 0.036), higher EuroSCORE II (mean 2.3 vs 1.8%; P < 0.001) and Society of Thoracic Surgeons score (mean 1.6 vs 0.9%; P < 0.001), were more often in New York Heart Association functional class III/IV (47% vs 30%; P < 0.001) and angina Canadian Cardiovascular Society III/IV (8.2% vs 4.4%; P < 0.001), but had a lower rate of myocardial infarction (1.9% vs 5.2%; P = 0.028) compared to males. These differences vanished after PSM, except for the EuroSCORE II and Society of Thoracic Surgeons scores, which were still significantly higher in females. Furthermore, females required smaller valves (median diameter 23.0 vs 25.0 mm, P < 0.001). There were no differences in the length of hospital stay (median 8 days) or intensive care unit stay (median 24 vs 25 hours) between the 2 sexes. At 2 years, post-SAVR outcomes were comparable between males and females, even after PSM. CONCLUSIONS: Despite females presenting with a significantly higher surgical risk profile, 2-year outcomes following SAVR were comparable between males and females.

3.
Vasa ; 53(5): 333-340, 2024 Sep.
Article de Anglais | MEDLINE | ID: mdl-38979892

RÉSUMÉ

Background: The current study aims to investigate the association between endothelial function and lower extremity perfusion in patients with peripheral artery disease (PAD). Patients and methods: In total 229 patients with PAD (Rutherford stage 0-3) were enrolled in the current study. Endothelial function was assessed by measuring flow-mediated dilation (FMD) and endothelial cell proliferation capacity (ECPC). Lower extremity perfusion was assessed by measuring oscillometry-based ankle brachial index (oABI) and pulse wave index (PWI). In addition, carotid intima-media-thickness (cIMT) was also measured as a surrogate marker for atherosclerosis. Correlations between FMD, ECPC, oABI, PWI, and cIMT were analysed using Pearson correlation coefficient. The relationship between the above variables and the severity of PAD was investigated using ordinal logistic regression analysis. Results: Correlation analysis showed that FMD negatively associated with PWI (r = -0.183, p = 0.005), ECPC positively associated with oABI (r = 0.162, p = 0.014), and oABI negatively associated with PWI (r = -0.264, p < 0.001). Ordinal logistic regression analysis showed that ECPC (ß = -0.009, p = 0.048), oABI (ß = -5.290, p < 0.001), and age (ß = -0.058, p = 0.002) negatively associated with the PAD Rutherford stages. In addition, PWI (ß = 0.006, p < 0.001), cIMT (ß = 18.363, p = 0.043) positively associated with the PAD Rutherford stages. Conclusions: Endothelial function significantly associates with lower extremity perfusion in patients with PAD, and both are related to the severity of PAD.


Sujet(s)
Index de pression systolique cheville-bras , Épaisseur intima-média carotidienne , Endothélium vasculaire , Membre inférieur , Maladie artérielle périphérique , Analyse de l'onde de pouls , Débit sanguin régional , Indice de gravité de la maladie , Vasodilatation , Humains , Maladie artérielle périphérique/physiopathologie , Maladie artérielle périphérique/diagnostic , Maladie artérielle périphérique/imagerie diagnostique , Mâle , Femelle , Membre inférieur/vascularisation , Sujet âgé , Adulte d'âge moyen , Endothélium vasculaire/physiopathologie , Prolifération cellulaire , Valeur prédictive des tests , Oscillométrie , Facteurs de risque , Cellules endothéliales , Études transversales
4.
AsiaIntervention ; 10(2): 110-118, 2024 Jul.
Article de Anglais | MEDLINE | ID: mdl-39070975

RÉSUMÉ

This paper discusses aortic stenosis (AS) in China, emphasising the role of transcatheter aortic valve replacement (TAVR) in treating AS in an ageing population. AS characteristics, its treatment and the clinical outcomes of transfemoral TAVR in Chinese patients are described via a systematic review. AS affects >1% of the Chinese population aged ≥65 years, with degenerative AS predominating over rheumatic AS among this age group. Chinese patients often have high aortic valve (AV) calcification with bicuspid AV morphology. In 2021, 38,000 surgical aortic valve replacements (SAVR) were reported in China, while the number of TAVR increased from 293 in 2017 to 7,357 in 2021. There are four self-expanding valves and one balloon-expandable SAPIEN 3 valve available in China. Among them, the Venus A-Valve is the most studied and widely used, whereas limited data are available for VitaFlow, TaurusOne, and SAPIEN 3. Notably, 10.0-16.5% of Venus A-Valve recipients and 0.2% of SAPIEN 3 recipients required multiple valve implantations. The rates of 30-day paravalvular leakage were 0-11.7%/0% for Venus A-Valve, 2.0%/0% for VitaFlow, and 0%/0% for SAPIEN 3, for moderate and severe leakage, respectively. Thirty-day all-cause mortality rates were 3.7-10.0% for Venus A-Valve, 0.9% for VitaFlow, and 0-3.2% for SAPIEN 3. One-year all-cause mortality rates were 5.9-13.6% for Venus A-Valve, 0-4.5% for VitaFlow, 6.7% for TaurusOne, and 6.2% for SAPIEN 3. The Venus A-Valve indicated lower 30-day permanent pacemaker implantation (PPI) rates (7.4-20.5%) than VitaFlow and TaurusOne. Outcomes for patients with bicuspid or tricuspid aortic valves were similar. AS is rising among the elderly Chinese population; SAVR is common, and TAVR is increasing. Limited device comparisons exist, but the Venus A-Valve seems to have lower PPI rates, and SAPIEN 3 has low 30-day mortality in China.

5.
Cardiovasc Diabetol ; 23(1): 198, 2024 Jun 12.
Article de Anglais | MEDLINE | ID: mdl-38867198

RÉSUMÉ

BACKGROUND: The TIM-HF2 study demonstrated that remote patient management (RPM) in a well-defined heart failure (HF) population reduced the percentage of days lost due to unplanned cardiovascular hospital admissions or all-cause death during 1-year follow-up (hazard ratio 0.80) and all-cause mortality alone (HR 0.70). Higher rates of hospital admissions and mortality have been reported in HF patients with diabetes compared with HF patients without diabetes. Therefore, in a post-hoc analysis of the TIM-HF2 study, we investigated the efficacy of RPM in HF patients with diabetes. METHODS: TIM-HF2 study was a randomized, controlled, unmasked (concealed randomization), multicentre trial, performed in Germany between August 2013 and May 2018. HF-Patients in NYHA class II/III who had a HF-related hospital admission within the previous 12 months, irrespective of left ventricular ejection fraction, and were randomized to usual care with or without added RPM and followed for 1 year. The primary endpoint was days lost due to unplanned cardiovascular hospitalization or due to death of any cause. This post-hoc analysis included 707 HF patients with diabetes. RESULTS: In HF patients with diabetes, RPM reduced the percentage of days lost due to cardiovascular hospitalization or death compared with usual care (HR 0.66, 95% CI 0.48-0.90), and the rate of all-cause mortality alone (HR 0.52, 95% CI 0.32-0.85). RPM was also associated with an improvement in quality of life (mean difference in change in global score of Minnesota Living with Heart Failure Questionnaire score (MLHFQ): - 3.4, 95% CI - 6.2 to - 0.6). CONCLUSION: These results support the use of RPM in HF patients with diabetes. CLINICAL TRIAL REGISTRATION: ClinicalTrials.gov NCT01878630.


Sujet(s)
Diabète , Défaillance cardiaque , Télémédecine , Humains , Défaillance cardiaque/mortalité , Défaillance cardiaque/diagnostic , Défaillance cardiaque/thérapie , Défaillance cardiaque/physiopathologie , Mâle , Femelle , Sujet âgé , Adulte d'âge moyen , Facteurs temps , Résultat thérapeutique , Allemagne/épidémiologie , Diabète/mortalité , Diabète/diagnostic , Diabète/thérapie , Facteurs de risque , Hospitalisation , Cause de décès , Sujet âgé de 80 ans ou plus , Admission du patient
6.
Eur J Clin Invest ; : e14274, 2024 Jun 26.
Article de Anglais | MEDLINE | ID: mdl-38925546

RÉSUMÉ

BACKGROUND: Invasive coronary angiography (ICA) is the standard for pre-procedural assessment of coronary artery disease (CAD) in patients undergoing transcatheter aortic valve implantation (TAVI). However, it requires hospitalization and can be associated with complications. Computed tomography angiography (CTA) may be a viable alternative to rule out prognostically relevant CAD. METHODS: The EASE-IT CT Registry is an investigator-initiated, prospective, observational, multicentre pilot registry involving patients aged ≥75 years with severe aortic stenosis (AS) intended to implant a transcatheter heart valve (THV) of the SAPIEN family. A total of 150 patients will be recruited from four sites in Germany and Austria. The registry will consist of two prospective cohorts: the investigational CTA-only cohort and the CTA + ICA control cohort. The CTA-only cohort will enrol 100 patients in whom significant (≥50%) left main (LM) and/or proximal left anterior descending artery (LAD) stenosis are ruled out on CTA. The CTA + ICA control cohort will enrol 50 patients who have undergone both CTA and ICA before TAVI and in whom ≥50% LM/proximal LAD stenosis has been ruled out by CTA. Three composite endpoints will be assessed at 3 months post-TAVI: CAD-specific endpoints, VARC-3-defined device success and early safety. CONCLUSION: The EASE-IT CT Registry evaluates whether TAVI can be carried out safely without performing ICA if prognostically relevant CAD of the LM/proximal LAD is ruled out with CTA. If so, the omission of ICA would help streamline the pre-procedural workup of TAVI patients.

7.
Eur J Clin Invest ; 54(9): e14241, 2024 Sep.
Article de Anglais | MEDLINE | ID: mdl-38767226

RÉSUMÉ

BACKGROUND: Transcatheter aortic valve implantation (TAVI) is increasingly being used in younger patients and those with lower peri-procedural risk, meaning more patients will live long enough to experience structural valve deterioration (SVD) of the bioprosthesis, indicating repeated TAVI. Experience of repeated TAVI-transcatheter heart valve (THV) implantation into an index THV is limited. This registry aims to assess the peri-procedural and short-term safety, efficacy and durability of repeated TAVI. METHODS: The ReTAVI Prospective observational registry is an investigator-initiated, multicentre, international, prospective registry of patients undergoing repeated TAVI using balloon-expandable SAPIEN prosthesis to evaluate procedural and short-term safety, efficacy and durability as well as anatomical and procedural factors associated with optimal results. The registry will enrol at least 150 patients across 60 high-volume centres. Patients must be ≥18 years old, have had procedural success with their first TAVI, have index THV device failure, intend to undergo repeated TAVI and be considered suitable candidates by their local Heart Team. All patients will undergo a 30-day and 12-month follow-up. The estimated study completion is 2025. CONCLUSIONS: The registry will collect pre-, peri-, postoperative and 12-months data on patients undergoing repeated TAVI procedures with THVs for failure of the index THV and determine VARC-3-defined efficacy and safety at 30 days and functional outcome at 12 months. The registry will expand existing data sets and identify patient characteristics/indicators related to complications and clinical benefits for patients with symptomatic severe calcific degenerative aortic stenosis.


Sujet(s)
Sténose aortique , Enregistrements , Remplacement valvulaire aortique par cathéter , Humains , Remplacement valvulaire aortique par cathéter/méthodes , Sténose aortique/chirurgie , Études prospectives , Résultat thérapeutique , Prothèse valvulaire cardiaque , Défaillance de prothèse , Mâle , Sujet âgé
8.
Cardiovasc Diabetol ; 23(1): 184, 2024 May 29.
Article de Anglais | MEDLINE | ID: mdl-38811998

RÉSUMÉ

BACKGROUND: Use of sodium-glucose-cotransporter-2 (SGLT2) inhibitors often causes an initial decline in glomerular filtration rate (GFR). This study addresses the question whether the initial decline of renal function with SGLT2 inhibitor treatment is related to vascular changes in the systemic circulation. METHODS: We measured GFR (mGFR) and estimated GFR (eGFR) in 65 patients with type 2 diabetes (T2D) at baseline and after 12 weeks of treatment randomized either to a combination of empagliflozin and linagliptin (SGLT2 inhibitor based treatment group) (n = 34) or metformin and insulin (non-SGLT2 inhibitor based treatment group) (n = 31). mGFR was measured using the gold standard clearance technique by constant infusion of inulin. In addition to blood pressure (BP), we measured pulse wave velocity (PWV) under standardized conditions reflecting vascular compliance of large arteries, as PWV is considered to be one of the most reliable vascular parameter of cardiovascular (CV) prognosis. RESULTS: Both mGFR and eGFR decreased significantly after initiating treatment, but no correlation was found between change in mGFR and change in eGFR in either treatment group (SGLT2 inhibitor based treatment group: r=-0.148, p = 0.404; non-SGLT2 inhibitor based treatment group: r = 0.138, p = 0.460). Noticeably, change in mGFR correlated with change in PWV (r = 0.476, p = 0.005) in the SGLT2 inhibitor based treatment group only and remained significant after adjustment for the change in systolic BP and the change in heart rate (r = 0.422, p = 0.018). No such correlation was observed between the change in eGFR and the change in PWV in either treatment group. CONCLUSIONS: Our main finding is that after initiating a SGLT2 inhibitor based therapy an exaggerated decline in mGFR was related with improved vascular compliance of large arteries reflecting the pharmacologic effects of SGLT2 inhibitor in the renal and systemic vascular bed. Second, in a single patient with T2D, eGFR may not be an appropriate parameter to assess the true change of renal function after receiving SGLT2 inhibitor based therapy. TRIAL REGISTRATION: clinicaltrials.gov (NCT02752113).


Sujet(s)
Composés benzhydryliques , Diabète de type 2 , Débit de filtration glomérulaire , Glucosides , Rein , Linagliptine , Analyse de l'onde de pouls , Inhibiteurs du cotransporteur sodium-glucose de type 2 , Humains , Inhibiteurs du cotransporteur sodium-glucose de type 2/usage thérapeutique , Inhibiteurs du cotransporteur sodium-glucose de type 2/effets indésirables , Débit de filtration glomérulaire/effets des médicaments et des substances chimiques , Mâle , Diabète de type 2/traitement médicamenteux , Diabète de type 2/physiopathologie , Diabète de type 2/diagnostic , Adulte d'âge moyen , Femelle , Composés benzhydryliques/usage thérapeutique , Composés benzhydryliques/effets indésirables , Sujet âgé , Résultat thérapeutique , Rein/effets des médicaments et des substances chimiques , Rein/physiopathologie , Glucosides/usage thérapeutique , Glucosides/effets indésirables , Facteurs temps , Linagliptine/usage thérapeutique , Linagliptine/effets indésirables , Metformine/usage thérapeutique , Insuline , Néphropathies diabétiques/physiopathologie , Néphropathies diabétiques/diagnostic , Néphropathies diabétiques/traitement médicamenteux , Rigidité vasculaire/effets des médicaments et des substances chimiques , Association de médicaments , Hypoglycémiants/usage thérapeutique , Hypoglycémiants/effets indésirables , Marqueurs biologiques/sang , Pertinence clinique , Transporteur-2 sodium-glucose
9.
Front Cardiovasc Med ; 11: 1302152, 2024.
Article de Anglais | MEDLINE | ID: mdl-38545345

RÉSUMÉ

Background and aims: In the non-metropolitan region of Brandenburg (Germany), which is characterized by high rates of cardiovascular diseases and underserved medical care, there is a lack of awareness regarding lipoprotein(a) [Lp(a)] as a risk factor. In addition, data from patients with atherosclerotic cardiovascular disease (ASCVD) in diverse regional backgrounds, including the understudied Brandenburg cohort, and various healthcare statuses remain insufficient. Methods: In this WalkByLab study, Lp(a) levels were monitored in a non-metropolitan cohort (n = 850) in Brandenburg, Germany, comprising 533 patients at high cardiovascular risk and 317 healthy controls. Patients underwent a comprehensive angiological screening, which included blood serum analysis, assessment of medical and family history, cardiovascular risk, and disease status, and evaluation of lifestyle and quality of life. All parameters were evaluated with regard to two groups based on Lp(a) levels: low (<50 mg/dl) and high (≥50 mg/dl). Results: Brandenburg patients with cardiovascular diseases showed higher Lp(a) levels than healthy controls (24.2% vs. 14.8%, p = 0.001). Logistic regression analysis with different characteristics revealed that Lp(a) was an independent risk factor significantly associated with ASCVD (OR 2.26, 95% CI 1.32-3.95, p = 0.003). The high-Lp(a) group showed a higher proportion of patients with coronary artery disease, peripheral artery disease, or cerebrovascular disease compared to the low-Lp(a) group (50% vs. 36.8%; 57.7% vs. 45.8%; 17.6% vs. 9.2%; p = 0.004); also, a higher percentage of patients in the high-Lp(a) group had heart failure (72.8% vs. 53.2%, p = 0.014) and myocardial infarction (24.7% vs. 13.9%, p = 0.001). The high-Lp(a) group exhibited higher rates of statins (63.1% vs. 50.4%, p = 0.003), ezetimibe (14.8% vs. 5.5.%, p = 0.001), and beta-blockers (55.7% vs. 40.7%, p = 0.001) use. Lp(a) levels were found to be independent of physical activity or smoking behavior and did not change over time (12 months). Conclusions: Our study highlights the significance of elevated Lp(a) levels in Brandenburg cardiovascular patients and identifies them as an independent risk factor for ASCVD, which has implications for addressing cardiovascular health of non-metropolitan populations.

10.
Eur Heart J ; 45(21): 1904-1916, 2024 Jun 01.
Article de Anglais | MEDLINE | ID: mdl-38554125

RÉSUMÉ

BACKGROUND AND AIMS: There is significant potential to streamline the clinical pathway for patients undergoing transcatheter aortic valve implantation (TAVI). The purpose of this study was to evaluate the effect of implementing BENCHMARK best practices on the efficiency and safety of TAVI in 28 sites in 7 European countries. METHODS: This was a study of patients with severe symptomatic aortic stenosis (AS) undergoing TAVI with balloon-expandable valves before and after implementation of BENCHMARK best practices. Principal objectives were to reduce hospital length of stay (LoS) and duration of intensive care stay. Secondary objective was to document patient safety. RESULTS: Between January 2020 and March 2023, 897 patients were documented prior to and 1491 patients after the implementation of BENCHMARK practices. Patient characteristics were consistent with a known older TAVI population and only minor differences. Mean LoS was reduced from 7.7 ± 7.0 to 5.8 ± 5.6 days (median 6 vs. 4 days; P < .001). Duration of intensive care was reduced from 1.8 to 1.3 days (median 1.1 vs. 0.9 days; P < .001). Adoption of peri-procedure best practices led to increased use of local anaesthesia (96.1% vs. 84.3%; P < .001) and decreased procedure (median 47 vs. 60 min; P < .001) and intervention times (85 vs. 95 min; P < .001). Thirty-day patient safety did not appear to be compromised with no differences in all-cause mortality (0.6% in both groups combined), stroke/transient ischaemic attack (1.4%), life-threatening bleeding (1.3%), stage 2/3 acute kidney injury (0.7%), and valve-related readmission (1.2%). CONCLUSIONS: Broad implementation of BENCHMARK practices contributes to improving efficiency of TAVI pathway reducing LoS and costs without compromising patient safety.


Sujet(s)
Sténose aortique , Référenciation , Durée du séjour , Remplacement valvulaire aortique par cathéter , Humains , Remplacement valvulaire aortique par cathéter/méthodes , Sténose aortique/chirurgie , Mâle , Femelle , Sujet âgé de 80 ans ou plus , Durée du séjour/statistiques et données numériques , Sujet âgé , Programme clinique , Europe/épidémiologie , Complications postopératoires/épidémiologie , Complications postopératoires/prévention et contrôle , Sécurité des patients
11.
Int J Cardiol ; 406: 131996, 2024 Jul 01.
Article de Anglais | MEDLINE | ID: mdl-38555056

RÉSUMÉ

OBJECTIVE: Management of patients with severe aortic stenosis (AS) may differ according to the patient sex. This study aimed to describe patterns of aortic valve replacement (AVR) for severe AS across Europe, including stratification by sex. METHODS: Procedure volume data for surgical aortic valve replacement (SAVR) and transcatheter aortic valve implantation (TAVI) for six years (2015-2020) were extracted from national databases for Austria, Czech Republic, Denmark, England, Finland, France, Germany, Norway, Poland, Spain, Sweden, and Switzerland and stratified by sex. Patients per million population (PPM) undergoing AVR per year were calculated using population estimates from Eurostat. RESULTS: Between 2015 and 2019, AVR procedures grew at an average annual rate of 3.9%. In 2020, the average total PPM undergoing AVR across all countries was 339, with 51% of procedures being TAVI and 49% SAVR. AVR PPM varied widely between countries, with the highest and lowest in Germany and Poland, respectively. The average total PPM was higher for men than women (423 vs. 258), but a higher proportion of women (62%) than men (44%) received TAVI. The proportion of TAVI among total AVR procedures increased with age, with an overall average of 96% of men and 98% of women aged ≥85 years receiving TAVI; however, adoption of TAVI varied by country. CONCLUSIONS: The analysis of temporal trends in the adoption of TAVI vs. SAVR across Europe showed significant variations. Despite the higher use of TAVI vs. SAVR in women, overall rates of AV intervention in women were lower compared to men.


Sujet(s)
Sténose aortique , Humains , Femelle , Mâle , Europe/épidémiologie , Sujet âgé , Sténose aortique/chirurgie , Sténose aortique/épidémiologie , Sujet âgé de 80 ans ou plus , Facteurs sexuels , Remplacement valvulaire aortique par cathéter/tendances , Remplacement valvulaire aortique par cathéter/statistiques et données numériques , Implantation de valve prothétique cardiaque/tendances , Implantation de valve prothétique cardiaque/statistiques et données numériques , Valve aortique/chirurgie , Adulte d'âge moyen
12.
Catheter Cardiovasc Interv ; 103(1): 137-146, 2024 01.
Article de Anglais | MEDLINE | ID: mdl-37890011

RÉSUMÉ

BACKGROUND: The development of the PASCAL transcatheter valve repair system for treating mitral regurgitation (MR) greatly extends therapeutic options. AIMS: To assess the safety, efficacy, and time efficiency of the PASCAL system in transcatheter edge-to-edge repair (TEER) under conscious sedation (CS). METHODS: This is a retrospective, two-center, German registry study consisting of 211 patients who underwent TEER using the PASCAL system under CS. The endpoints were to assess (1) technical, device, and procedural success as per Mitral Valve Academic Research Consortium (MVARC), (2) conversion rate to general anesthesia (GA), (3) hospital length of stay (LoS), (4) New York Heart Association (NYHA) class, and (5) MR compared to baseline at 30-day. RESULTS: A total of 211 patients with a mean age of 78.4 ± 8.9 years, with 51.4% being female and 86.7% belonging to NYHA functional class III/IV and EuroSCORE II 6.3 ± 4.9%, were enrolled. Procedural success attained was 96.9%, and six patients (2.8%) required conversion from CS to GA. At 30 days follow-up, a significant improvement in MR was found in 96 patients (54.2%) patients with 0/1 grade MR and 45 patients (29.5%) were in NYHA functional class III + IV. Moreover, TEER under CS has a short hospital LoS (6.71 ± 5.29 days) and intensive care unit LoS (1.34 ± 3.49 days) with a 2.8% mortality rate. CONCLUSIONS: Performing TEER with the PASCAL system under CS resulted in appreciable (96.9%) procedural success with low mortality and is a safe and promising alternative to GA with positive clinical outcomes.


Sujet(s)
Implantation de valve prothétique cardiaque , Insuffisance mitrale , Humains , Femelle , Sujet âgé , Sujet âgé de 80 ans ou plus , Mâle , Valve atrioventriculaire gauche/imagerie diagnostique , Valve atrioventriculaire gauche/chirurgie , Sédation consciente/effets indésirables , Études rétrospectives , Résultat thérapeutique , Insuffisance mitrale/imagerie diagnostique , Insuffisance mitrale/chirurgie , Cathétérisme cardiaque
13.
Diabetes Obes Metab ; 25(12): 3700-3708, 2023 12.
Article de Anglais | MEDLINE | ID: mdl-37694759

RÉSUMÉ

AIM: To assess the implementation of the 2019 European Society of Cardiology (ESC)/European Atherosclerosis Society (EAS) guideline recommendations for lipid-lowering therapies among more than 30 000 patients with type 1 diabetes (T1D) and type 2 diabetes (T2D) in a German and Austrian registry from 2020 to 2022. MATERIALS AND METHODS: Registry data from 2020 and 2021 of 32 170 adult patients (8314 patients with T1D and 23 856 with T2D) were stratified according to the 2019 ESC/EAS risk categories, and guideline-based low-density lipoprotein cholesterol (LDL-C) and non-high-density lipoprotein cholesterol (non-HDL-C) goal attainment was analysed. RESULTS: In patients with T1D (median age 38.35 [20.51-57.13] years), overall statin use was 19.3%, ezetimibe use was 2.2% and the use of proprotein convertase subtilisin/kexin type 9 (PCSK9) inhibitors or fibrates was less than 1%. In patients with T2D (median age 68.76 [58.86-78.39] years), 45.7% received statins, 3.4% received ezetimibe, and fibrates and PCSK9 inhibitors were used by 1% and 0.1%, respectively. Among patients with T1D, 6.16% reached their risk-based recommended LDL-C goal of less than 55 mg/dL (very high risk), 10.97% of less than 70 mg/dL (high risk), and 69.50% of less than 100 mg/dL (moderate risk), respectively. In patients with T2D, 11.81% reached their risk-based goal of LDL-C less than 55 mg/dL, 16.25% of less than 70 mg/dL, and 51.33% of less than 100 mg/dL. Non-HDL-C goals were reached more often, with 15.3%, 25.52% and 91.61% in patients with T1D and 18.56%, 17.96% and 82.30% in patients with T2D for very high, high and moderate risk, respectively. CONCLUSION: Approximately 2 years after publication of the guidelines, LDL-C and non-HDL-C goal attainment was rarely achieved in patients with T1D and T2D with a high or very high cardiovascular risk.


Sujet(s)
Anticholestérolémiants , Athérosclérose , Diabète de type 1 , Diabète de type 2 , Dyslipidémies , Inhibiteurs de l'hydroxyméthylglutaryl-CoA réductase , Adulte , Humains , Sujet âgé , Cholestérol LDL , Proprotéine convertase 9 , Diabète de type 1/traitement médicamenteux , Diabète de type 1/épidémiologie , Diabète de type 2/complications , Diabète de type 2/traitement médicamenteux , Diabète de type 2/épidémiologie , Autriche/épidémiologie , Objectifs , Cholestérol , Inhibiteurs de l'hydroxyméthylglutaryl-CoA réductase/usage thérapeutique , Ézétimibe/usage thérapeutique , Enregistrements , Acides fibriques , Anticholestérolémiants/usage thérapeutique , Dyslipidémies/thérapie
14.
BJA Open ; 6: 100140, 2023 Jun.
Article de Anglais | MEDLINE | ID: mdl-37588176

RÉSUMÉ

Background: Intraoperative hypotension is associated with organ injury. Current intraoperative arterial pressure management is mainly reactive. Predictive haemodynamic monitoring may help clinicians reduce intraoperative hypotension. The Acumen™ Hypotension Prediction Index software (HPI-software) (Edwards Lifesciences, Irvine, CA, USA) was developed to predict hypotension. We built up the European multicentre, prospective, observational EU HYPROTECT Registry to describe the incidence, duration, and severity of intraoperative hypotension when using HPI-software monitoring in patients having noncardiac surgery. Methods: We enrolled 749 patients having elective major noncardiac surgery in 12 medical centres in five European countries. Patients were monitored using the HPI-software. We quantified hypotension using the time-weighted average MAP <65 mm Hg (primary endpoint), the proportion of patients with at least one ≥1 min episode of a MAP <65 mm Hg, the number of ≥1 min episodes of a MAP <65 mm Hg, and duration patients spent below a MAP of 65 mm Hg. Results: We included 702 patients in the final analysis. The median time-weighted average MAP <65 mm Hg was 0.03 (0.00-0.20) mm Hg. In addition, 285 patients (41%) had no ≥1 min episode of a MAP <65 mm Hg; 417 patients (59%) had at least one. The median number of ≥1 min episodes of a MAP <65 mm Hg was 1 (0-3). Patients spent a median of 2 (0-9) min below a MAP of 65 mm Hg. Conclusions: The median time-weighted average MAP <65 mm Hg was very low in patients in this registry. This suggests that using HPI-software monitoring may help reduce the duration and severity of intraoperative hypotension in patients having noncardiac surgery.

15.
Cardiology ; 148(6): 547-555, 2023.
Article de Anglais | MEDLINE | ID: mdl-37586346

RÉSUMÉ

INTRODUCTION: The management of patients with severe aortic stenosis may differ according to patients' age. The aim of this analysis was to describe patterns of aortic valve replacement (AVR) use in European countries stratified by age. METHODS: Procedure volume data for AVR, including surgical aortic valve replacement (sAVR) and transcatheter aortic valve implantation (TAVI), for the years 2015-2020 were obtained from national databases for twelve European countries (Austria, the Czech Republic, Denmark, England, Finland, France, Germany, Norway, Poland, Spain, Sweden, and Switzerland). Procedure volumes were reported by patient age (<50 years, 5-year age groups between 50 and 85 years, and ≥85 years). Patients per million (PPM) population undergoing AVR each year were calculated using population estimates from Eurostat. RESULTS: AVR PPM varied widely between countries, from 508 PPM in Germany to 174 PPM in Poland in 2020. TAVI rates ranged from 61% in Switzerland and Finland to 25% in Poland. AVR PPM increased with age to a peak at 80-84 years, after which it decreased again. AVR procedures increased from 2015 to 2019 at an average annual rate of 3.9%. AVR increased more substantially in people aged ≥80 years than in younger age groups; these older age groups accounted for 30% of all AVR procedures in 2015 and 35% in 2019. TAVI accounted for an increasing proportion of all AVR procedures as patient age increased; an overall average of 96% of males and 98% of females aged ≥85 years received TAVI as the treatment modality, although adoption of TAVI differed between countries. CONCLUSIONS: There is considerable variation in the rates of AVR use and the adoption of TAVI versus sAVR between European countries. The use of TAVI has increased in recent years, particularly for older patients.


Sujet(s)
Sténose aortique , Implantation de valve prothétique cardiaque , Remplacement valvulaire aortique par cathéter , Femelle , Mâle , Humains , Sujet âgé , Valve aortique/chirurgie , Sténose aortique/chirurgie , Facteurs de risque , Résultat thérapeutique , Remplacement valvulaire aortique par cathéter/méthodes , Europe , Implantation de valve prothétique cardiaque/méthodes
16.
Cardiology ; 148(6): 556-570, 2023.
Article de Anglais | MEDLINE | ID: mdl-37442111

RÉSUMÉ

BACKGROUND: Elderly patients with aortic stenosis (AS) not only have a reduced life expectancy but also a reduced quality of life (QoL). The benefits of an AS intervention may be considered a balance between a good QoL and a reasonably extended life. However, the different questionnaires being used to determine the QoL were generally not developed for the specific situation of patients with AS and come with strengths and considerable weaknesses. The objective of this article was to provide an overview of the available QoL instruments in AS research, describe their strengths and weaknesses, and provide our assessment of the utility of the available scoring instruments for QoL measurements in AS. SUMMARY: We identified and reviewed the following instruments that are used in AS research: Short Form Health Survey (SF-36/SF-12), EuroQol-5D (EQ-5D), the Illness Intrusiveness Rating Scale (IIRS), the HeartQoL, the Kansas City Cardiomyopathy Questionnaire (KCCQ), the Minnesota Living with Heart Failure Questionnaire (MLHF), the MacNew Questionnaire, and the Toronto Aortic Stenosis Quality of Life Questionnaire (TASQ). KEY MESSAGES: There is no standardized assessment of QoL in patients with AS. Many different questionnaires are being used, but they are rarely specific for AS. There is a need for AS-specific research into the QoL of patients as life prolongation may compete for an improved QoL in this elderly patient group.


Sujet(s)
Sténose aortique , Défaillance cardiaque , Humains , Sujet âgé , Qualité de vie , Enquêtes et questionnaires
17.
Article de Anglais | MEDLINE | ID: mdl-37462612

RÉSUMÉ

OBJECTIVES: We report 1-year safety and clinical outcomes in patients <60 years undergoing bioprosthetic surgical aortic valve intervention. METHODS: The INSPIRIS RESILIA Durability Registry is a prospective, multicentre registry to assess clinical outcomes of patients <60 years. Patients with planned SAVR with or without concomitant replacement of the ascending aorta and/or coronary bypass surgery were included. Time-related valve safety, haemodynamic performance and quality of life (QoL) at 1 year were assessed. RESULTS: A total of 421 patients were documented with a mean age of 53.5 years, 76.5% being male and 27.2% in NYHA class III/IV. Outcomes within 30 days included cardiovascular-related mortality (0.7%), time-related valve safety (VARC-2; 5.8%), thromboembolic events (1.7%), valve-related life-threatening bleeding (VARC-2; 4.3%) and permanent pacemaker implantation (3.8%). QoL was significantly increased at 6 months and sustained at 1 year. Freedom from all-cause mortality at 1 year was 98.3% (95% confidence interval 97.1; 99.6) and 81.8% were NYHA I versus 21.9% at baseline. No patient developed structural valve deterioration stage 3 (VARC-3). The mean aortic pressure gradient was 12.6 mmHg at 1 year and the effective orifice area was 1.9 cm2. CONCLUSIONS: The 1-year data from the INSPIRIS RESILIA valve demonstrate good safety and excellent haemodynamic performance as well as an early QoL improvement. CLINICAL TRIAL REGISTRATION: clinicaltrials.gov: NCT03666741.

18.
BMC Cardiovasc Disord ; 23(1): 295, 2023 06 10.
Article de Anglais | MEDLINE | ID: mdl-37301870

RÉSUMÉ

BACKGROUND: Transcatheter aortic valve implantation (TAVI) can either be conducted as an elective (scheduled in advance) or a non-elective procedure performed during an unplanned hospital admission. The objective of this study was to compare the outcomes of elective and non-elective TAVI patients. METHODS: This single-centre study included 512 patients undergoing transfemoral TAVI between October 2018 and December 2020; 378 (73.8%) were admitted for elective TAVI, 134 (26.2%) underwent a non-elective procedure. Our TAVI programme entails an optimized fast-track concept aimed at minimizing the total length of stay to ≤ 5 days for elective patients which in the German healthcare system is currently defined as the minimal time period to safely perform TAVI. Clinical characteristics and survival rates at 30 days and 1 year were analysed. RESULTS: Patients who underwent non-elective TAVI had a significantly higher comorbidity burden. Median duration from admission to discharge was 6 days (elective group 6 days versus non-elective group 15 days; p < 0.001), including a median postprocedural stay of 5 days (elective 4 days versus non-elective 7 days; p < 0.001). All-cause mortality at 30 days was 1.1% for the elective group and 3.7% for non-elective patients (p = 0.030). At 1 year, all-cause mortality among elective TAVI patients was disproportionately lower than in non-elective patients (5.0% versus 18.7%, p < 0.001). In the elective group, 54.5% of patients could not be discharged early due to comorbidities or procedural complications. Factors associated with a failure of achieving a total length of stay of ≤ 5 days comprised frailty syndrome, renal impairment as well as new permanent pacemaker implantation, new bundle branch block or atrial fibrillation, life-threatening bleeding, and the use of self-expanding valves. After multivariate adjustment, new permanent pacemaker implantation (odds ratio 6.44; 95% CI 2.59-16.00), life-threatening bleeding (odds ratio 4.19; 95% confidence interval 1.82-9.66) and frailty syndrome (odds ratio 5.15; 95% confidence interval 2.40-11.09; all p < 0.001, respectively) were confirmed as significant factors. CONCLUSIONS: While non-elective patients had acceptable periprocedural outcomes, mortality rates at 1 year were significantly higher compared to elective patients. Approximately only half of elective patients could be discharged early. Improvements in periprocedural care, follow-up strategies and optimized treatment of both elective and non-elective TAVI patients are needed.


Sujet(s)
Sténose aortique , Fibrillation auriculaire , Fragilité , Prothèse valvulaire cardiaque , Remplacement valvulaire aortique par cathéter , Humains , Sujet âgé , Remplacement valvulaire aortique par cathéter/effets indésirables , Sténose aortique/imagerie diagnostique , Sténose aortique/chirurgie , Personne âgée fragile , Universités , Bloc de branche/étiologie , Fibrillation auriculaire/étiologie , Résultat thérapeutique , Valve aortique/imagerie diagnostique , Valve aortique/chirurgie , Facteurs de risque , Prothèse valvulaire cardiaque/effets indésirables
19.
Front Cardiovasc Med ; 10: 1157571, 2023.
Article de Anglais | MEDLINE | ID: mdl-37342445

RÉSUMÉ

Background: We investigated the association between leukocyte telomere length, mitochondrial DNA copy number, and endothelial function in patients with aging-related cardiovascular disease (CVD). Methods: In total 430 patients with CVD and healthy persons were enrolled in the current study. Peripheral blood was drawn by routine venipuncture procedure. Plasma and peripheral blood mononuclear cells (PBMCs) were collected. Cell-free genomic DNA (cfDNA) and leukocytic genomic DNA (leuDNA) were extracted from plasma and PBMCs, respectively. Relative telomere length (TL) and mitochondrial DNA copy number (mtDNA-CN) were analyzed using quantitative polymerase chain reaction. Endothelial function was evaluated by measuring flow-mediated dilation (FMD). The correlation between TL of cfDNA (cf-TL), mtDNA-CN of cfDNA (cf-mtDNA), TL of leuDNA (leu-TL), mtDNA-CN of leuDNA (leu-mtDNA), age, and FMD were analyzed based on Spearman's rank correlation. The association between cf-TL, cf-mtDNA, leu-TL, leu-mtDNA, age, gender, and FMD were explored using multiple linear regression analysis. Results: cf-TL positively correlated with cf-mtDNA (r = 0.1834, P = 0.0273), and leu-TL positively correlated with leu-mtDNA (r = 0.1244, P = 0.0109). In addition, both leu-TL (r = 0.1489, P = 0.0022) and leu-mtDNA (r = 0.1929, P < 0.0001) positively correlated with FMD. In a multiple linear regression analysis model, both leu-TL (ß = 0.229, P = 0.002) and leu-mtDNA (ß = 0.198, P = 0.008) were positively associated with FMD. In contrast, age was inversely associated with FMD (ß = -0.426, P < 0.0001). Conclusion: TL positively correlates mtDNA-CN in both cfDNA and leuDNA. leu-TL and leu-mtDNA can be regarded as novel biomarkers of endothelial dysfunction.

20.
Heart ; 109(18): 1394-1400, 2023 08 24.
Article de Anglais | MEDLINE | ID: mdl-37376817

RÉSUMÉ

OBJECTIVE: Ventricular secondary mitral regurgitation (SMR) (Carpentier type IIIb) results from left ventricular (LV) remodelling, displacement of papillary muscles and tethering of mitral leaflets. The most appropriate treatment approach remains controversial. We aimed to assess the safety and efficacy of standardised relocation of both papillary muscles (subannular repair) at 1-year follow-up (FU). METHODS: REFORM-MR (Reform-Mitral Regurgitation) is a prospective, multicentre registry that enrolled consecutive patients with ventricular SMR (Carpentier type IIIb) undergoing standardised subannular mitral valve (MV) repair in combination with annuloplasty at five sites in Germany. Here, we report survival, freedom from recurrence of MR >2+, freedom from major adverse cardiac and cerebrovascular events (MACCEs), including cardiovascular death, myocardial infarction, stroke, MV reintervention and echocardiographic parameters of residual leaflet tethering at 1-year FU. RESULTS: A total of 94 patients (69.1% male) with a mean age of 65.1±9.7 years met the inclusion criteria. Advanced LV dysfunction (mean left ventricular ejection fraction 36.4±10.5%) and severe LV dilatation (mean left ventricular end-diastolic diameter 61.0±9.3 mm) resulted in severe mitral leaflet tethering (mean tenting height 10.6±3.0 mm) and an elevated mean EURO Score II of 4.8±4.6 prior to surgery. Subannular repair was successfully performed in all patients, without operative mortality or complications. One-year survival was 95.5%. At 12 months, a durable reduction of mitral leaflet tethering resulted in a low rate (4.2%) of recurrent MR >2+. In addition to a significant improvement in New York Heart Association (NYHA) class (22.4% patients in NYHA III/IV vs 64.5% patients at baseline, p<0.001), freedom from MACCE was observed in 91.1% of patients. CONCLUSIONS: Our study demonstrates the safety and feasibility of standardised subannular repair to treat ventricular SMR (Carpentier type IIIb) in a multicentre setting. By addressing mitral leaflet tethering, papillary muscle relocation results in very satisfactory 1-year outcomes and has the potential to durably restore MV geometry; nevertheless, long-term FU is mandatory. TRIAL REGISTRATION NUMBER: NCT03470155.


Sujet(s)
Annuloplastie mitrale , Insuffisance mitrale , Sujet âgé , Femelle , Humains , Mâle , Adulte d'âge moyen , Annuloplastie mitrale/effets indésirables , Annuloplastie mitrale/méthodes , Insuffisance mitrale/imagerie diagnostique , Insuffisance mitrale/étiologie , Insuffisance mitrale/chirurgie , Études prospectives , Débit systolique , Systole , Résultat thérapeutique , Fonction ventriculaire gauche
SÉLECTION CITATIONS
DÉTAIL DE RECHERCHE