Your browser doesn't support javascript.
loading
Montrer: 20 | 50 | 100
Résultats 1 - 3 de 3
Filtrer
Plus de filtres











Base de données
Gamme d'année
1.
Magn Reson Imaging ; 113: 110219, 2024 Nov.
Article de Anglais | MEDLINE | ID: mdl-39069027

RÉSUMÉ

This study investigated the use of a Vision Transformer (ViT) for reconstructing GABA-edited Magnetic Resonance Spectroscopy (MRS) data from a reduced number of transients. Transients refer to the samples collected during an MRS acquisition by repeating the experiment to generate a signal of sufficient quality. Specifically, 80 transients were used instead of the typical 320 transients, aiming to reduce scan time. The 80 transients were pre-processed and converted into a spectrogram image representation using the Short-Time Fourier Transform (STFT). A pre-trained ViT, named Spectro-ViT, was fine-tuned and then tested using in-vivo GABA-edited MEGA-PRESS data. Its performance was compared against other pipelines in the literature using quantitative quality metrics and estimated metabolite concentration values, with the typical 320-transient scans serving as the reference for comparison. The Spectro-ViT model exhibited the best overall quality metrics among all other pipelines against which it was compared. The metabolite concentrations from Spectro-ViT's reconstructions for GABA+ achieved the best average R2 value of 0.67 and the best average Mean Absolute Percentage Error (MAPE) value of 9.68%, with no significant statistical differences found compared to the 320-transient reference. The code to reproduce this research is available at https://github.com/MICLab-Unicamp/Spectro-ViT.


Sujet(s)
Algorithmes , Traitement d'image par ordinateur , Spectroscopie par résonance magnétique , Acide gamma-amino-butyrique , Acide gamma-amino-butyrique/métabolisme , Humains , Spectroscopie par résonance magnétique/méthodes , Traitement d'image par ordinateur/méthodes , Analyse de Fourier , Encéphale/imagerie diagnostique , Encéphale/métabolisme , Imagerie par résonance magnétique/méthodes
2.
Magn Reson Imaging ; 111: 186-195, 2024 Sep.
Article de Anglais | MEDLINE | ID: mdl-38744351

RÉSUMÉ

PURPOSE: To determine the significance of complex-valued inputs and complex-valued convolutions compared to real-valued inputs and real-valued convolutions in convolutional neural networks (CNNs) for frequency and phase correction (FPC) of GABA-edited magnetic resonance spectroscopy (MRS) data. METHODS: An ablation study using simulated data was performed to determine the most effective input (real or complex) and convolution type (real or complex) to predict frequency and phase shifts in GABA-edited MEGA-PRESS data using CNNs. The best CNN model was subsequently compared using both simulated and in vivo data to two recently proposed deep learning (DL) methods for FPC of GABA-edited MRS. All methods were trained using the same experimental setup and evaluated using the signal-to-noise ratio (SNR) and linewidth of the GABA peak, choline artifact, and by visually assessing the reconstructed final difference spectrum. Statistical significance was assessed using the Wilcoxon signed rank test. RESULTS: The ablation study showed that using complex values for the input represented by real and imaginary channels in our model input tensor, with complex convolutions was most effective for FPC. Overall, in the comparative study using simulated data, our CC-CNN model (that received complex-valued inputs with complex convolutions) outperformed the other models as evaluated by the mean absolute error. CONCLUSION: Our results indicate that the optimal CNN configuration for GABA-edited MRS FPC uses a complex-valued input and complex convolutions. Overall, this model outperformed existing DL models.


Sujet(s)
Spectroscopie par résonance magnétique , , Rapport signal-bruit , Acide gamma-amino-butyrique , Acide gamma-amino-butyrique/métabolisme , Acide gamma-amino-butyrique/analyse , Spectroscopie par résonance magnétique/méthodes , Humains , Encéphale/imagerie diagnostique , Encéphale/métabolisme , Apprentissage profond , Algorithmes , Artéfacts , Choline/métabolisme , Simulation numérique
3.
MAGMA ; 37(3): 449-463, 2024 Jul.
Article de Anglais | MEDLINE | ID: mdl-38613715

RÉSUMÉ

PURPOSE: Use a conference challenge format to compare machine learning-based gamma-aminobutyric acid (GABA)-edited magnetic resonance spectroscopy (MRS) reconstruction models using one-quarter of the transients typically acquired during a complete scan. METHODS: There were three tracks: Track 1: simulated data, Track 2: identical acquisition parameters with in vivo data, and Track 3: different acquisition parameters with in vivo data. The mean squared error, signal-to-noise ratio, linewidth, and a proposed shape score metric were used to quantify model performance. Challenge organizers provided open access to a baseline model, simulated noise-free data, guides for adding synthetic noise, and in vivo data. RESULTS: Three submissions were compared. A covariance matrix convolutional neural network model was most successful for Track 1. A vision transformer model operating on a spectrogram data representation was most successful for Tracks 2 and 3. Deep learning (DL) reconstructions with 80 transients achieved equivalent or better SNR, linewidth and fit error compared to conventional 320 transient reconstructions. However, some DL models optimized linewidth and SNR without actually improving overall spectral quality, indicating a need for more robust metrics. CONCLUSION: DL-based reconstruction pipelines have the promise to reduce the number of transients required for GABA-edited MRS.


Sujet(s)
Apprentissage profond , Spectroscopie par résonance magnétique , Rapport signal-bruit , Acide gamma-amino-butyrique , Acide gamma-amino-butyrique/métabolisme , Humains , Spectroscopie par résonance magnétique/méthodes , , Algorithmes , Encéphale/imagerie diagnostique , Encéphale/métabolisme , Apprentissage machine , Traitement d'image par ordinateur/méthodes , Simulation numérique
SÉLECTION CITATIONS
DÉTAIL DE RECHERCHE