Your browser doesn't support javascript.
loading
Montrer: 20 | 50 | 100
Résultats 1 - 20 de 91
Filtrer
1.
JACC Adv ; 3(7): 100981, 2024 Jul.
Article de Anglais | MEDLINE | ID: mdl-39130036

RÉSUMÉ

Shared decision-making (SDM) and multidisciplinary team-based care delivery are recommended across several cardiology clinical practice guidelines. However, evidence for benefit and guidance on implementation are limited. Informed consent, the use of patient decision aids, or the documentation of these elements for governmental or societal agencies may be conflated as SDM. SDM is a bidirectional exchange between experts: patients are the experts on their goals, values, and preferences, and clinicians provide their expertise on clinical factors. In this Expert Panel perspective, we review the current state of SDM in team-based cardiovascular care and propose best practice recommendations for multidisciplinary team implementation of SDM.

2.
Article de Anglais | MEDLINE | ID: mdl-38871537

RÉSUMÉ

BACKGROUND: Permanent pacemaker implantation (PPI) rates following transcatheter aortic valve replacement (TAVR) remain a concern. We assessed the PPI rates over time in patients implanted with an Evolut supra-annular, self-expanding transcatheter valve from the US STS/ACC TVT Registry. METHODS: Patients who underwent TAVR with an Evolut R, Evolut PRO or Evolut PRO+ valve between July 2018 (Q3) and June 2021 (Q2) were included. PPI rates were reported by calendar quarter. In-hospital PPI rates were reported as proportions and 30-day rates as Kaplan-Meier estimates. A Cox regression model was used to determine potential predictors of a new PPI within 30 days of the TAVR procedure. RESULTS: From July 2018 to June 2021, 54,014 TAVR procedures were performed using Evolut valves. Mean age was 79.3 ± 8.8 years and 49.2 % were male. The 30-day PPI rate was 16.6 % in 2018 (Q3) and 10.8 % in 2021 (Q2, 34.9 % decrease, p < 0.001 for trend across all quarters). The in-hospital PPI rate decreased by 40.1 %; from 14.7 % in 2018 (Q3) to 8.8 % in 2021 (Q2) (p < 0.001 for trend across all quarters). Significant predictors of a new PPI within 30 days included a baseline conduction defect, history of atrial fibrillation, home oxygen, and diabetes mellitus. CONCLUSION: From 2018 to 2021, TAVR with an Evolut transcatheter heart valve in over 50,000 patients showed a significant decreasing trend in the rates of in-hospital and 30-day PPI, representing the lowest rate of PPI in any large real-world registry of Evolut. During the same evaluated period, high device success and shorter length of stay was also observed.

3.
PLoS One ; 19(5): e0302378, 2024.
Article de Anglais | MEDLINE | ID: mdl-38771808

RÉSUMÉ

BACKGROUND: Guidelines recommend shared decision making when choosing treatment for severe aortic stenosis but implementation has lagged. We assessed the feasibility and impact of a novel decision aid for severe aortic stenosis at point-of-care. METHODS: This prospective multi-site pilot cohort study included adults with severe aortic stenosis and their clinicians. Patients were referred by their heart team when scheduled to discuss treatment options. Outcomes included shared decision-making processes, communication quality, decision-making confidence, decisional conflict, knowledge, stage of decision making, decision quality, and perceptions of the tool. Patients were assessed at baseline (T0), after using the intervention (T1), and after the clinical encounter (T2); clinicians were assessed at T2. Before the encounter, patients reviewed the intervention, Aortic Valve Improved Treatment Approaches (AVITA), an interactive, online decision aid. AVITA presents options, frames decisions, clarifies patient goals and values, and generates a summary to use with clinicians during the encounter. RESULTS: 30 patients (9 women [30.0%]; mean [SD] age 70.4 years [11.0]) and 14 clinicians (4 women [28.6%], 7 cardiothoracic surgeons [50%]) comprised 28 clinical encounters Most patients [85.7%] and clinicians [84.6%] endorsed AVITA. Patients reported AVITA easy to use [89.3%] and helped them choose treatment [95.5%]. Clinicians reported the AVITA summary helped them understand their patients' values [80.8%] and make values-aligned recommendations [61.5%]. Patient knowledge significantly improved at T1 and T2 (p = 0.004). Decisional conflict, decision-making stage, and decision quality improved at T2 (p = 0.0001, 0.0005, and 0.083, respectively). Most patients [60%] changed treatment preference between T0 and T2. Initial treatment preferences were associated with low knowledge, high decisional conflict, and poor decision quality; final preferences were associated with high knowledge, low conflict, and high quality. CONCLUSIONS: AVITA was endorsed by patients and clinicians, easy to use, improved shared decision-making quality and helped patients and clinicians arrive at a treatment that reflected patients' values. TRIAL REGISTRATION: Trial ID: NCT04755426, Clinicaltrials.gov/ct2/show/NCT04755426.


Sujet(s)
Sténose aortique , Prise de décision partagée , Techniques d'aide à la décision , Études de faisabilité , Préférence des patients , Humains , Sténose aortique/thérapie , Sténose aortique/chirurgie , Femelle , Mâle , Projets pilotes , Sujet âgé , Adulte d'âge moyen , Études prospectives , Sujet âgé de 80 ans ou plus , Participation des patients , Médecins/psychologie , Relations médecin-patient , Prise de décision
5.
Heart Rhythm ; 2024 May 18.
Article de Anglais | MEDLINE | ID: mdl-38768843

RÉSUMÉ

BACKGROUND: Although expertise in left atrial appendage occlusion (LAAO) has grown, certain intricate anatomies may pose challenges, rendering them unsuitable for LAAO with the selected device. OBJECTIVE: This analysis aimed to characterize outcomes of patients with prior failed percutaneous LAAO procedures who underwent a subsequent attempt with an Amulet occluder in the EMERGE LAA postapproval study. METHODS: Patients enrolled in the National Cardiovascular Data Registry LAAO Registry who had an Amulet occluder implantation attempt between Food and Drug Administration approval (August 14, 2021) and June 30, 2023, were evaluated. A safety end point through 7 days or hospital discharge (whichever was later) and major adverse events through 45 days were reported. RESULTS: A total of 8591 patients underwent attempted Amulet occluder implantation, of whom 244 patients had prior failed LAAO. Implantation success was 88.9% and 96.2% in patients with prior failed LAAO and index LAAO, respectively (P < .001). The safety composite end point was low, occurring in 1.6% and 0.8% of patients with prior failed LAAO and index LAAO, respectively (P = .148). Any major adverse event through 45 days occurred in 7.4% and 6.3% of prior failed LAAO and index LAAO patient cohorts, respectively (P = .497); most adverse events were similar between the groups (P > .05). At 45 days, peridevice leak ≤3 mm was achieved in >90% of patients in either group. CONCLUSION: A high degree of implantation success with a low rate of adverse events can be achieved with the Amulet occluder. The findings imply that the dual occlusive mechanism Amulet occluder facilitates successful closure, even in challenging anatomic scenarios.

6.
Am Heart J ; 274: 54-64, 2024 08.
Article de Anglais | MEDLINE | ID: mdl-38621577

RÉSUMÉ

BACKGROUND: Recent studies suggest that aortic valve replacement (AVR) remains underutilized. AIMS: Investigate the potential role of non-referral to heart valve specialists (HVS) on AVR utilization. METHODS: Patients with severe aortic stenosis (AS) between 2015 and 2018, who met class I indication for intervention, were identified. Baseline data and process-related parameters were collected to analyze referral predictors and evaluate outcomes. RESULTS: Among 981 patients meeting criteria AVR, 790 patients (80.5%) were assessed by HVS within six months of index TTE. Factors linked to reduced referral included increasing age (OR: 0.95; 95% CI: 0.94-0.97; P < .001), unmarried status (OR: 0.59; 95% CI: 0.43-0.83; P = .002) and inpatient TTE (OR: 0.27; 95% CI: 0.19-0.38; P < .001). Conversely, higher hematocrit (OR: 1.13; 95% CI: 1.09-1.16; P < .001) and eGFR (OR: 1.01; 95% CI: 1.00-1.02; P = .003), mean aortic valve gradient (OR: 1.03; 95% CI: 1.01-1.04; P < .001) and preserved LVEF (OR: 1.59; 95% CI: 1.02-2.48; P = .04), were associated with increased referral likelihood. Moreover, patients assessed by HVS referral as a time-dependent covariate had a significantly lower two-year mortality risk than those who were not (aHR: 0.30; 95% CI: 0.23-0.39; P < .001). CONCLUSION: A substantial proportion of severe AS patients meeting indications for AVR are not evaluated by HVS and experience markedly increased mortality. Further research is warranted to assess the efficacy of care delivery mechanisms, such as e-consults, and telemedicine, to improve access to HVS expertise.


Sujet(s)
Sténose aortique , Implantation de valve prothétique cardiaque , Orientation vers un spécialiste , Humains , Orientation vers un spécialiste/statistiques et données numériques , Femelle , Mâle , Sténose aortique/chirurgie , Sujet âgé , Implantation de valve prothétique cardiaque/méthodes , Sujet âgé de 80 ans ou plus , Études rétrospectives , Valve aortique/chirurgie , Échocardiographie , Adulte d'âge moyen
7.
JACC Cardiovasc Interv ; 17(7): 874-886, 2024 Apr 08.
Article de Anglais | MEDLINE | ID: mdl-38599690

RÉSUMÉ

BACKGROUND: Adequate valve performance after surgical mitral valve repair with an annuloplasty ring is not always sustained over time. The risk of repeat mitral valve surgery may be high in these patients. Transcatheter mitral valve-in-ring (MViR) is emerging as an alternative for high-risk patients. OBJECTIVES: The authors sought to assess contemporary outcomes of MViR using third-generation balloon-expandable aortic transcatheter heart valves. METHODS: Patients who underwent MViR and were enrolled in the STDS/ACC TVT (Society of Thoracic Surgeons/American College of Cardiology Transcatheter Valve Therapy) Registry between August 2015 and December 2022 were analyzed. RESULTS: A total of 820 patients underwent MViR at 236 sites, mean age was 72.2 ± 10.4 years, 50.9% were female, mean STS score was 8.2% ± 6.9%, and most (78%) were in NYHA functional class III to IV. Mean left ventricular ejection fraction was 47.8% ± 14.2%, mean mitral gradient was 8.9 ± 7.0 mm Hg, and 75.5% had ≥ moderate mitral regurgitation. Access was transseptal in 93.9% with 88% technical success. All-cause mortality at 30 days was 8.3%, and at 1 year, 22.4%, with a reintervention rate of 9.1%. At 1-year follow-up, 75.6% were NYHA functional class I to II, Kansas City Cardiomyopathy Questionnaire score increased by 25.9 ± 29.1 points, mean mitral valve gradient was 8.4 ± 3.4 mm Hg, and 91.7% had ≤ mild mitral regurgitation. CONCLUSIONS: MViR with third-generation balloon-expandable aortic transcatheter heart valves is associated with a significant reduction in mitral regurgitation and improvement in symptoms at 1 year, but with elevated valvular gradients and a high reintervention rate. MViR is a reasonable alternative for high-risk patients unable undergo surgery who have appropriate anatomy for the procedure. (STS/ACC TVT Registry Mitral Module [TMVR]; NCT02245763).


Sujet(s)
Implantation de valve prothétique cardiaque , Prothèse valvulaire cardiaque , Insuffisance mitrale , Humains , Femelle , Adulte d'âge moyen , Sujet âgé , Sujet âgé de 80 ans ou plus , Mâle , Valve atrioventriculaire gauche/imagerie diagnostique , Valve atrioventriculaire gauche/chirurgie , Insuffisance mitrale/imagerie diagnostique , Insuffisance mitrale/chirurgie , Insuffisance mitrale/étiologie , Débit systolique , Résultat thérapeutique , Fonction ventriculaire gauche , Cathétérisme cardiaque/méthodes
9.
Article de Anglais | MEDLINE | ID: mdl-38310499

RÉSUMÉ

BACKGROUND: The Food and Drug Administration approved the Amulet occluder (Abbott) after demonstrating safety and effectiveness in the Amulet IDE (AMPLATZER Amulet LAA Occluder) trial. OBJECTIVES: The aim of the EMERGE Left Atrial Appendage study is to evaluate early postapproval outcomes of the Amulet occluder in the United States using data from the National Cardiovascular Data Registry Left Atrial Appendage Occlusion Registry. METHODS: Patients with a commercial Amulet occluder implant attempt between Food and Drug Administration approval (August 14, 2021) and December 31, 2022, were included. The safety composite endpoint included all-cause death, ischemic stroke, systemic embolism, or device/procedure-related events requiring open cardiac surgery or endovascular intervention between device implantation and 7 days or hospital discharge (whichever is later). Major adverse events through 45 days were also reported and stratified by operator experience (early [<10 cases], moderate [10-29 cases], and high [30+ cases]). RESULTS: A total of 5,499 patients underwent attempted Amulet occluder implantation. Implant success was 95.8%, and complete closure was 97.2% post-left atrial appendage occlusion and 87.1% at 45 days. A safety composite endpoint event occurred in 0.76% patients. Any major adverse event occurred in 2.9% and 5.7% of patients in-hospital and through 45 days, respectively, driven by major bleeding and pericardial effusion (PE) requiring intervention. PE requiring surgery or percutaneous intervention decreased significantly with increasing experience both in-hospital (early vs high operator experience 1.8% vs 1.1%; P = 0.006) and at 45 days (2.3% vs 1.5%; P = 0.012). CONCLUSIONS: The EMERGE Left Atrial Appendage study demonstrates favorable safety and effectiveness of the Amulet occluder in the real-world setting. More experienced operators had improved implant success and fewer PEs, suggesting a learning curve effect implanting this dual occlusive mechanism device.

10.
Circ Cardiovasc Interv ; 17(2): e013298, 2024 02.
Article de Anglais | MEDLINE | ID: mdl-38235547

RÉSUMÉ

BACKGROUND: Frailty associates with worse outcomes after transcatheter aortic valve replacement (TAVR). Sarcopenia underlies frailty, but the association between a comprehensive assessment of sarcopenia-muscle mass, strength, and performance-and outcomes after TAVR has not been examined. METHODS: From a multicenter prospective registry of patients with symptomatic severe aortic stenosis undergoing TAVR, 445 who had a preprocedure computed tomography and clinical assessment of frailty were included. Cross-sectional muscle (psoas and paraspinal) areas were measured on computed tomography and indexed to height. Gait speed and handgrip strength were obtained, and patients were dichotomized into fast versus slow; strong versus weak; and normal versus low muscle mass. As measures of body composition, cross-sectional fat (subcutaneous and visceral) was measured and indexed to height. RESULTS: The frequency of patients who were slow, weak, and had low muscle mass was 56%, 59%, and 42%, respectively. Among the 3 components of sarcopenia, only slower gait speed (muscle performance) was independently associated with increased post-TAVR mortality (adjusted hazard ratio, 1.12 per 0.1 m/s decrease [95% CI, 1.04-1.21]; P=0.004; adjusted hazard ratio, 1.38 per 1 SD decrease [95% CI, 1.11-1.72]; P=0.004). Meeting multiple sarcopenia criteria was not associated with higher mortality risk than fewer. Lower indexed visceral fat area (adjusted hazard ratio, 1.48 per 1 SD decrease [95% CI, 1.15-1.89]; P=0.002) was associated with mortality but indexed subcutaneous fat was not. Death occurred in 169 (38%) patients. CONCLUSIONS: Among patients with symptomatic severe aortic stenosis and comprehensive sarcopenia and body composition phenotyping, gait speed was the only sarcopenia measure associated with post-TAVR mortality. Lower visceral fat was also associated with increased risk pointing to an obesity paradox also observed in other patient populations. These findings reinforce the clinical utility of gait speed as a measure of risk and a potential target for adjunctive interventions alongside TAVR to optimize clinical outcomes.


Sujet(s)
Sténose aortique , Fragilité , Sarcopénie , Remplacement valvulaire aortique par cathéter , Humains , Sarcopénie/imagerie diagnostique , Sarcopénie/complications , Fragilité/diagnostic , Fragilité/complications , Résultat thérapeutique , Force de la main , Études transversales , Appréciation des risques , Sténose aortique/imagerie diagnostique , Sténose aortique/chirurgie , Sténose aortique/complications , Composition corporelle , Valve aortique/imagerie diagnostique , Valve aortique/chirurgie , Facteurs de risque
11.
JACC Cardiovasc Interv ; 16(22): 2708-2718, 2023 Nov 27.
Article de Anglais | MEDLINE | ID: mdl-37943200

RÉSUMÉ

BACKGROUND: Left atrial appendage occlusion (LAAO) is an approved alternative for stroke prevention in atrial fibrillation for patients with an "appropriate rationale" to avoid long-term oral anticoagulation (OAC). Many patients undergoing LAAO are at high risk of bleeding. OBJECTIVES: This study sought to investigate whether dual antiplatelet therapy (DAPT) is a safe alternative to OAC (direct oral anticoagulation [DOAC] or warfarin) with aspirin after LAAO. METHODS: Using National Cardiovascular Data Registry LAAO registry data, patients undergoing Watchman FLX (Boston Scientific) implantation (August 5, 2020-September 30, 2021) were included in 1:1 propensity-matched analyses comparing discharge medication regimens (DAPT, DOAC/aspirin, or warfarin/aspirin). A composite endpoint (death, stroke, major bleeding, and systemic embolism), its components, and device-related thrombus between discharge and 45 days were evaluated. RESULTS: In 49,968 patients implanted with the Watchman FLX during the study period, the mean age was 77 years, and 40% were women. Postimplant DOAC/aspirin was prescribed in 24,497 patients, warfarin/aspirin in 3,913, and DAPT in 4,155. DAPT patients had more comorbid conditions than patients receiving OAC/aspirin. After propensity score matching, the 45-day composite endpoint rates were similar among the groups (DAPT = 3.44% vs DOAC/aspirin: 4.06%; P = 0.13 and DAPT = 3.23% vs warfarin/aspirin: 3.08%; P = 0.75). Death, stroke, and device-related thrombus were also similar; major bleeding was slightly increased in DOAC/aspirin patients (DAPT = 2.48% vs DOAC/aspirin = 3.25%; P = 0.04 and DAPT = 2.25% vs warfarin/aspirin = 2.22%; P = 0.93). CONCLUSIONS: In a large registry, DAPT had a similar safety profile compared with current Food and Drug Administration-approved postimplant drug regimens of OAC with aspirin following LAAO with the Watchman FLX. Shared decision making for nonpharmacologic stroke prevention should include a discussion of postprocedure medical therapy options.


Sujet(s)
Auricule de l'atrium , Fibrillation auriculaire , Accident vasculaire cérébral , Thrombose , Humains , Femelle , Sujet âgé , Mâle , Warfarine/effets indésirables , Antiagrégants plaquettaires/effets indésirables , Anticoagulants/effets indésirables , Résultat thérapeutique , Accident vasculaire cérébral/diagnostic , Accident vasculaire cérébral/étiologie , Accident vasculaire cérébral/prévention et contrôle , Fibrillation auriculaire/diagnostic , Fibrillation auriculaire/traitement médicamenteux , Hémorragie/induit chimiquement , Acide acétylsalicylique/effets indésirables , Thrombose/traitement médicamenteux , Enregistrements
13.
Circ Cardiovasc Interv ; 16(8): e012875, 2023 08.
Article de Anglais | MEDLINE | ID: mdl-37503662

RÉSUMÉ

BACKGROUND: Depression and cognitive dysfunction (CD) are not routinely screened for in patients before transcatheter aortic valve replacement (TAVR) and their association with postprocedural outcomes is poorly understood. The objectives of this study are to determine the prevalence of depression and CD in patients with aortic stenosis undergoing TAVR and evaluate their association with mortality and quality of life. METHODS: We analyzed a prospective, multicenter TAVR registry that systematically screened patients for preexisting depression and CD with the Patient Health Questionnaire-2 and Mini-Cog, respectively. The associations with mortality were assessed with Cox proportional hazard models and quality of life (Kansas City Cardiomyopathy Questionnaire and EuroQol visual analogue scale) were evaluated using multivariable ordinal regression models. RESULTS: A total of 884 patients were included; median follow-up was 2.88 years (interquartile range=1.2-3.7). At baseline, depression was observed in 19.6% and CD in 31.8%. In separate models, after adjustment, depression (HR, 1.45 [95% CI, 1.13-1.86]; P<0.01) and CD (HR, 1.27 [95% CI, 1.02-1.59]; P=0.04) were each associated with increased mortality. Combining depression and CD into a single model, mortality was greatest among those with both depression and CD (n=62; HR, 2.06 [CI, 1.44-2.96]; P<0.01). After adjustment, depression was associated with 6.6 (0.3-13.6) points lower on the Kansas City Cardiomyopathy Questionnaire 1-year post-TAVR and 6.7 (0.5-12.7) points lower on the EuroQol visual analogue scale. CD was only associated with lower EuroQol visual analogue scale. CONCLUSIONS: Depression and CD are common in patients that undergo TAVR and are associated with increased mortality and worse quality of life. Depression may be a modifiable therapeutic target to improve outcomes after TAVR.


Sujet(s)
Sténose aortique , Cardiomyopathies , Dysfonctionnement cognitif , Remplacement valvulaire aortique par cathéter , Humains , Remplacement valvulaire aortique par cathéter/effets indésirables , Qualité de vie , Études prospectives , Dépression/diagnostic , Dépression/épidémiologie , Résultat thérapeutique , Sténose aortique/imagerie diagnostique , Sténose aortique/chirurgie , Sténose aortique/épidémiologie , Dysfonctionnement cognitif/diagnostic , Dysfonctionnement cognitif/épidémiologie , Dysfonctionnement cognitif/étiologie , Soins centrés sur le patient , Cardiomyopathies/chirurgie , Valve aortique/imagerie diagnostique , Valve aortique/chirurgie , Facteurs de risque
14.
JAMA Cardiol ; 8(9): 871-878, 2023 09 01.
Article de Anglais | MEDLINE | ID: mdl-37494015

RÉSUMÉ

Importance: Inadequate representation of older patients, women, and racial minority individuals in cardiovascular clinical trials limits both the generalizability of trial findings and inclusivity in access to novel therapies and therapeutic strategies. Objective: To report on temporal trends in the representation of older patients, women, and racial and ethnic minority individuals in clinical trials studying treatments for valvular heart disease. Evidence Review: All published clinical trials enrolling more than 100 adults with any valvular heart disease published between 2005 and 2020 were included after searches with PubMed and ClinicalTrials.gov. Data on age, sex, race, and ethnicity reported in the included studies were collected. Trials were assigned to 4 time periods based on the publication date, and temporal trends were analyzed in the representation of older patients, women, and racial and ethnic minority individuals. Findings: A total of 139 clinical trials with 51 527 participants were identified. Of these trials, 103 (74%) investigated aortic valve disease and the remainder mitral valve disease. Overall, 63 trials (45.3%) enrolled patients only in Europe, 24 (17.3%) only in North America, and 19 (13.7%) in multiple geographical regions. The weighted mean (SD) age of enrolled patients was 68.4 (11.4) years, increasing nonsignificantly from 61.9 (5.9) years in 2005-2008 to 72.8 (9.6) years in 2017-2020 (P = .09 for trend). The overall proportion of women enrolled in valvular heart disease trials was 41.1%, with no significant changes over time. Data on race and ethnicity of trial participants were reported in 13 trials (9.4%), in which trial-level representation of American Indian/Alaska Native, Asian, Black/African American, Hispanic, and Native Hawaiian/Pacific Islander patients ranged from 0.27% to 43.9%. There were no significant temporal trends noted in the enrollment of racial and ethnic minority populations. The representation of women in clinical trials was positively associated with enrollment rates of older patients and underrepresented racial and ethnic groups. Conclusions and Relevance: This review found that over the past 2 decades, women and racial and ethnic minority individuals have remained underrepresented in North American valvular heart disease clinical trials. Further work is needed to improve the reporting of race and ethnicity data and address barriers to trial enrollment for older patients, women, and racial and ethnic minority individuals.


Sujet(s)
Ethnies , Valvulopathies , Adulte , Humains , Femelle , Sujet âgé , Minorités , Minorités ethniques et raciales , Hispanique ou Latino
16.
J Am Heart Assoc ; 12(13): e029542, 2023 07 04.
Article de Anglais | MEDLINE | ID: mdl-37345820

RÉSUMÉ

Background Studies in mice and small patient subsets implicate metabolic dysfunction in cardiac remodeling in aortic stenosis, but no large comprehensive studies of human metabolism in aortic stenosis with long-term follow-up and characterization currently exist. Methods and Results Within a multicenter prospective cohort study, we used principal components analysis to summarize 12 echocardiographic measures of left ventricular structure and function pre-transcatheter aortic valve implantation in 519 subjects (derivation). We used least absolute shrinkage and selection operator regression across 221 metabolites to define metabolic signatures for each structural pattern and measured their relation to death and multimorbidity in the original cohort and up to 2 validation cohorts (N=543 for overall validation). In the derivation cohort (519 individuals; median age, 84 years, 45% women, 95% White individuals), we identified 3 axes of left ventricular remodeling, broadly specifying systolic function, diastolic function, and chamber volumes. Metabolite signatures of each axis specified both known and novel pathways in hypertrophy and cardiac dysfunction. Over a median of 3.1 years (205 deaths), a metabolite score for diastolic function was independently associated with post-transcatheter aortic valve implantation death (adjusted hazard ratio per 1 SD increase in score, 1.54 [95% CI, 1.25-1.90]; P<0.001), with similar effects in each validation cohort. This metabolite score of diastolic function was simultaneously associated with measures of multimorbidity, suggesting a metabolic link between cardiac and noncardiac state in aortic stenosis. Conclusions Metabolite profiles of cardiac structure identify individuals at high risk for death following transcatheter aortic valve implantation and concurrent multimorbidity. These results call for efforts to address potentially reversible metabolic biology associated with risk to optimize post-transcatheter aortic valve implantation recovery, rehabilitation, and survival.


Sujet(s)
Sténose aortique , Remplacement valvulaire aortique par cathéter , Humains , Femelle , Animaux , Souris , Sujet âgé de 80 ans ou plus , Mâle , Multimorbidité , Études prospectives , Résultat thérapeutique , Valve aortique/chirurgie , Fonction ventriculaire gauche
17.
JAMA Cardiol ; 8(8): 715-716, 2023 08 01.
Article de Anglais | MEDLINE | ID: mdl-37314799

RÉSUMÉ

This Viewpoint describes how shared decision-making should be used in patients with aortic stenosis who have a longer life expectancy.


Sujet(s)
Sténose aortique , Humains , Sténose aortique/chirurgie , Prise de décision partagée , Espérance de vie
18.
Am Heart J ; 264: 123-132, 2023 10.
Article de Anglais | MEDLINE | ID: mdl-37279840

RÉSUMÉ

BACKGROUND: Percutaneous left atrial appendage (LAA) closure (LAAC) was developed as a nonpharmacologic alternative to oral anticoagulants (OACs) in patients with atrial fibrillation (AF) who are at an increased risk for stroke or systemic embolism. The Watchman device permanently seals off the LAA to prevent thrombi from escaping into the circulation. Previous randomized trials have established the safety and efficacy of LAAC compared to warfarin. However, direct OACs (DOACs) have become the preferred pharmacologic strategy for stroke prevention in patients with AF, and there is limited data comparing Watchman FLX to DOACs in a broad AF patient population. CHAMPION-AF is designed to prospectively determine whether LAAC with Watchman FLX is a reasonable first-line alternative to DOACs in patients with AF who are indicated for OAC therapy. STUDY DESIGN: A total of 3,000 patients with a CHA2DS2-VASc score ≥2 (men) or ≥3 (women) were randomized to Watchman FLX or DOAC in a 1:1 allocation at 142 global clinical sites. Patients in the device arm were to be treated with DOAC and aspirin, DOAC alone, or DAPT for at least 3 months postimplant followed by aspirin or P2Y12 inhibitor for 1-year. Control patients were required to take an approved DOAC for the duration of the trial. Clinical follow-up visits are scheduled at 3- and 12-months, and then annually through 5 years; LAA imaging is required at 4 months in the device group. Two primary end points will be evaluated at 3 years: (1) composite of stroke (ischemic/hemorrhagic), cardiovascular death, and systemic embolism compared for noninferiority, and (2) nonprocedural bleeding (International Society on Thrombosis and Haemostasis [ISTH] major and clinically relevant nonmajor bleeding) tested for superiority in the device arm against DOACs. The third primary noninferiority end point is the composite of ischemic stroke and systemic embolism at 5 years. Secondary end points include 3- and 5-year rates of (1) ISTH-defined major bleeding and (2) the composite of cardiovascular death, all stroke, systemic embolism, and nonprocedural ISTH bleeding. CONCLUSIONS: This study will prospectively evaluate whether LAAC with the Watchman FLX device is a reasonable alternative to DOACs in patients with AF. CLINICAL TRIAL REGISTRATION: NCT04394546.


Sujet(s)
Auricule de l'atrium , Fibrillation auriculaire , Embolie , Accident vasculaire cérébral , Mâle , Humains , Femelle , Fibrillation auriculaire/complications , Fibrillation auriculaire/traitement médicamenteux , Résultat thérapeutique , Études de suivi , Auricule de l'atrium/chirurgie , Anticoagulants/usage thérapeutique , Accident vasculaire cérébral/étiologie , Accident vasculaire cérébral/prévention et contrôle , Accident vasculaire cérébral/épidémiologie , Hémorragie/induit chimiquement , Hémorragie/complications , Acide acétylsalicylique/usage thérapeutique , Embolie/prévention et contrôle
SÉLECTION CITATIONS
DÉTAIL DE RECHERCHE