Endosc Ultrasound ; 13(1): 6-15, 2024.
Article de Anglais | MEDLINE | ID: mdl-38947115

RÉSUMÉ

Endobronchial ultrasound (EBUS) is a minimally invasive highly accurate and safe endoscopic technique for the evaluation of mediastinal lymphadenopathy and mediastinal masses including centrally located lung tumors. The combination of transbronchial and transoesophageal tissue sampling has improved lung cancer staging, reducing the need for more invasive and surgical diagnostic procedures. Despite the high level of evidence regarding EBUS use in the aforementioned situations, there are still challenges and controversial issues such as follows: Should informed consent for EBUS and flexible bronchoscopy be different? Is EBUS able to replace standard bronchoscopy in patients with suspected lung cancer? Which is the best position, screen orientation, route of intubation, and sedation/anesthesia to perform EBUS? Is it advisable to use a balloon in all procedures? How should the operator acquire skills and how should competence be ensured? This Pro-Con article aims to address these open questions.

2.
Endosc Ultrasound ; 13(2): 55-64, 2024.
Article de Anglais | MEDLINE | ID: mdl-38947746

RÉSUMÉ

Rare malignant mesenchymal pancreatic tumors are systematized and reported in this review. The focus is on the appearance on imaging. The present overview summarizes the data and shows that not every pancreatic tumor corresponds to the most common entities of ductal adenocarcinoma or neuroendocrine tumor.

4.
World J Urol ; 42(1): 302, 2024 May 08.
Article de Anglais | MEDLINE | ID: mdl-38720010

RÉSUMÉ

PURPOSE: To evaluate the diagnostic performance of contrast-enhanced (CE) ultrasound using Sonazoid (SNZ-CEUS) by comparing with contrast-enhanced computed tomography (CE-CT) and contrast-enhanced magnetic resonance imaging (CE-MRI) for differentiating benign and malignant renal masses. MATERIALS AND METHODS: 306 consecutive patients (from 7 centers) with renal masses (40 benign tumors, 266 malignant tumors) diagnosed by both SNZ-CEUS, CE-CT or CE-MRI were enrolled between September 2020 and February 2021. The examinations were performed within 7 days, but the sequence was not fixed. Histologic results were available for 301 of 306 (98.37%) lesions and 5 lesions were considered benign after at least 2 year follow-up without change in size and image characteristics. The diagnostic performances were evaluated by sensitivity, specificity, positive predictive value, negative predictive value, and compared by McNemar's test. RESULTS: In the head-to-head comparison, SNZ-CEUS and CE-MRI had comparable sensitivity (95.60 vs. 94.51%, P = 0.997), specificity (65.22 vs. 73.91%, P = 0.752), positive predictive value (91.58 vs. 93.48%) and negative predictive value (78.95 vs. 77.27%); SNZ-CEUS and CE-CT showed similar sensitivity (97.31 vs. 96.24%, P = 0.724); however, SNZ-CEUS had relatively lower than specificity than CE-CT (59.09 vs. 68.18%, P = 0.683). For nodules > 4 cm, CE-MRI demonstrated higher specificity than SNZ-CEUS (90.91 vs. 72.73%, P = 0.617) without compromise the sensitivity. CONCLUSIONS: SNZ-CEUS, CE-CT, and CE-MRI demonstrate desirable and comparable sensitivity for the differentiation of renal mass. However, the specificity of all three imaging modalities is not satisfactory. SNZ-CEUS may be a suitable alternative modality for patients with renal dysfunction and those allergic to gadolinium or iodine-based agents.


Sujet(s)
Produits de contraste , Composés du fer III , Fer , Tumeurs du rein , Imagerie par résonance magnétique , Oxydes , Tomodensitométrie , Échographie , Humains , Tumeurs du rein/imagerie diagnostique , Tumeurs du rein/anatomopathologie , Mâle , Femelle , Adulte d'âge moyen , Études prospectives , Échographie/méthodes , Tomodensitométrie/méthodes , Imagerie par résonance magnétique/méthodes , Sujet âgé , Diagnostic différentiel , Adulte , Sujet âgé de 80 ans ou plus
5.
Radiology ; 311(2): e232369, 2024 May.
Article de Anglais | MEDLINE | ID: mdl-38805727

RÉSUMÉ

The American College of Radiology Liver Imaging Reporting and Data System (LI-RADS) standardizes the imaging technique, reporting lexicon, disease categorization, and management for patients with or at risk for hepatocellular carcinoma (HCC). LI-RADS encompasses HCC surveillance with US; HCC diagnosis with CT, MRI, or contrast-enhanced US (CEUS); and treatment response assessment (TRA) with CT or MRI. LI-RADS was recently expanded to include CEUS TRA after nonradiation locoregional therapy or surgical resection. This report provides an overview of LI-RADS CEUS Nonradiation TRA v2024, including a lexicon of imaging findings, techniques, and imaging criteria for posttreatment tumor viability assessment. LI-RADS CEUS Nonradiation TRA v2024 takes into consideration differences in the CEUS appearance of viable tumor and posttreatment changes within and in close proximity to a treated lesion. Due to the high sensitivity of CEUS to vascular flow, posttreatment reactive changes commonly manifest as areas of abnormal perilesional enhancement without washout, especially in the first 3 months after treatment. To improve the accuracy of CEUS for nonradiation TRA, different diagnostic criteria are used to evaluate tumor viability within and outside of the treated lesion margin. Broader criteria for intralesional enhancement increase sensitivity for tumor viability detection. Stricter criteria for perilesional enhancement limit miscategorization of posttreatment reactive changes as viable tumor. Finally, the TRA algorithm reconciles intralesional and perilesional tumor viability assessment and assigns a single LI-RADS treatment response (LR-TR) category: LR-TR nonviable, LR-TR equivocal, or LR-TR viable.


Sujet(s)
Carcinome hépatocellulaire , Produits de contraste , Tumeurs du foie , Échographie , Humains , Tumeurs du foie/imagerie diagnostique , Tumeurs du foie/radiothérapie , Carcinome hépatocellulaire/imagerie diagnostique , Carcinome hépatocellulaire/radiothérapie , Échographie/méthodes , Systèmes d'information de radiologie , Foie/imagerie diagnostique , Résultat thérapeutique
6.
Med Ultrason ; 2024 Apr 15.
Article de Anglais | MEDLINE | ID: mdl-38805622

RÉSUMÉ

Point-of-care ultrasound (POCUS) plays an essential role in emergency medicine, providing a range of diagnostic and procedural modalities. It does not involve any ionizing radiation and can improve procedural accuracy and safety. The role of POCUS in the care of pediatric patients differs somewhat from that of adult patients, as there are a range of conditions specific to infants and children. The technical background of pediatric POCUS and its current applications for trauma and thoracic scanning are reviewed and illustrated in this first article of this series.

7.
Med Ultrason ; 2024 Apr 26.
Article de Anglais | MEDLINE | ID: mdl-38805621

RÉSUMÉ

The 50th year of the European Federation of Societies in Ultrasound in Medicine and Biology (EFSUMB) has been celebrated 2022 publishing articles on the history of US. Contrast enhanced ultrasound (CEUS) allows to visualize blood flow and tissue perfusion. CEUS has proven to be safe without risk of nephrotoxicity. The availability of a contrast agent (tracer) for ultrasound imaging allows for the first time a dynamic assessment of tissue perfusion (blood flow and wash-in/wash-out pattern) which is an essential part for the detection and characterisation of pathological tissue and abnormal organ function. It was an outstanding achievement of academic centers in close cooperation with EFSUMB to investigate and validate the clinical potential of this new technology for the diagnosis and monitoring of various diseases and to develop clinical guidelines based on an in-depth assessment of the existing scientific publications. An important part of the implementation of CEUS in clinical practice was the development of contrast-specific imaging modes on the ultrasound scanners (in close cooperation with the machine manufacturers), the optimization of the machine setups for contrast imaging and the education provided to clinical users in form of workshops, webinars, textbooks and scientific congresses.

8.
Ultraschall Med ; 2024 Apr 08.
Article de Anglais | MEDLINE | ID: mdl-38588693

RÉSUMÉ

PURPOSE: To evaluate the diagnostic yield of contrast-enhanced ultrasound (CEUS)-guided biopsy of retroperitoneal masses (RMs). MATERIALS AND METHODS: Between 2006 and 2023, 87 patients presented at our US center for biopsy of an RM. In all biopsies, CEUS was performed prior to the intervention. The technical success rate of biopsy, the presence of diagnostic tissue in solid tumor biopsy samples, the accuracy of the biopsy and the occurrence of post-interventional complications were evaluated. RESULTS: A US-guided biopsy could be conducted in 84/87 cases (96.6%). In 3/87 cases (3.4%), US-guided biopsy was impossible because the planned needle path was obstructed by vital structures. Of 84 lesions, 80 (95.2%) were solid lesions, and 4 (4.8%) were lesions containing fluid. In all solid tumors, 80/80 (100%), diagnostic vital tissue was successfully obtained. CEUS-guided biopsy showed a sensitivity of 93.2%, a specificity of 100%, a positive predictive value of 100%, a negative predictive value of 72.2%, and a diagnostic accuracy of 94.2% for the differentiation between malignant and benign RMs. In one of the 84 cases (1.2%), there was a complication of postinterventional abdominal pain. CONCLUSION: Percutaneous CEUS-guided biopsy is a safe procedure with a high diagnostic yield and a low complication rate.

9.
Diagnostics (Basel) ; 14(7)2024 Mar 27.
Article de Anglais | MEDLINE | ID: mdl-38611619

RÉSUMÉ

This review describes the appearance of extrapulmonary tuberculosis manifestations in comprehensive and multiparametric ultrasound imaging. The aim is to increase awareness of typical ultrasound findings regarding extrapulmonary tuberculosis, correlate those with pathological features, and facilitate differential diagnosis. Point of care ultrasound protocols can be used as a screening method in high-risk populations, although the negative findings do not exclude tuberculosis. Conversely, the diagnosis of extrapulmonary tuberculosis can never be made using ultrasound alone, as many ultrasound findings in extrapulmonary tuberculosis are non-specific. However, ultrasound-based sampling techniques can significantly facilitate the collection of samples for microbiological or molecular proof of tuberculosis, as well as facilitating the establishment of alternative diagnoses.

11.
Ultraschall Med ; 2024 Mar 14.
Article de Anglais | MEDLINE | ID: mdl-38484782

RÉSUMÉ

As an extension of the clinical examination and as a diagnostic and problem-solving tool, ultrasound has become an established technique for clinicians. A prerequisite for high-quality clinical ultrasound practice is adequate student ultrasound training. In light of the considerable heterogeneity of ultrasound curricula in medical studies worldwide, this review presents basic principles of modern medical student ultrasound education and advocates for the establishment of an ultrasound core curriculum embedded both horizontally and vertically in medical studies.

12.
Ultraschall Med ; 2024 Mar 21.
Article de Anglais, Allemand | MEDLINE | ID: mdl-38513687

RÉSUMÉ

Simulation-based training (SBT) is increasingly acknowledged worldwide and has become a popular tool for ultrasound education. Ultrasound simulation involves the use of technology and software to create a virtual training setting. Simulation-based training allows healthcare professionals to learn, practice, and improve their ultrasound imaging skills in a safe learning-based environment. SBT can provide a realistic and focused learning experience that creates a deep and immersive understanding of the complexity of ultrasound, including enhancing knowledge and confidence in specific areas of interest. Abdominal ultrasound simulation is a tool to increase patient safety and can be a cost-efficient training method. In this paper, we provide an overview of various types of abdominal ultrasound simulators, and the benefits, and challenges of SBT. We also provide examples of how to develop SBT programs and learning strategies including mastery learning. In conclusion, the growing demand for medical imaging increases the need for healthcare professionals to start using ultrasound simulators in order to keep up with the rising standards.

13.
Article de Anglais | MEDLINE | ID: mdl-38393894

RÉSUMÉ

OBJECTIVE: To evaluate pancreatic tissue stiffness and provide a normal reference shear wave velocity (SWV) value of pancreas from healthy adults by Virtual Touch Imaging Quantification (VTIQ) measurements. METHODS: Healthy adult volunteers without known history of hepatobiliary or pancreatic diseases were included. VTIQ elastography (Siemens ACUSON Sequoia, 5C-1 transducer) was used. SWV values were measured at the cephalic, corpus and tail of pancreas and replicated different operators' obtained data. Subgroups were classified according to the volunteers' gender, age, body mass index (BMI), depth of measurements and the echogenicity of the pancreas. RESULTS: From February 2023 to July 2023, 33 healthy adult volunteers were included. The success rate of VTIQ measurements in cephalic, corpus and tail regions was 90.90 % (30/33), 96.97 % (32/33) and 90.90 % (30/33) respectively. The color elastograms of healthy adult pancreas showed uniform blue or simultaneously blue and green. The average SWV values were 0.97±0.26 m/s for cephalic, 0.91±0.24 m/s for corpus and 0.97±0.25 m/s for pancreatic tail respectively (P = 0.198). The mean SWV values of pancreas did not show significant difference with age, gender or depth (P >  0.05). BMI was an influence factor in the measurements of SWV values of cephalic and tail of pancreas (P <  0.05). Pancreas with hyperechoic parenchyma showed higher mean SWV values (P <  0.05). The intra-observer (ICC = 0.938 [95% CI: 0.869-0.971]) and the inter-observer (ICC = 0.887 [95% CI: 0.760-0.947]) agreements of VTIQ measurements were excellent. CONCLUSIONS: The mean SWV value of the pancreas in healthy adults was 0.96±0.20 m/s (range: 0.52-1.74 m/s). VTIQ technique can be used in pancreatic stiffness measurements with good reliability.

14.
Z Gastroenterol ; 62(5): 723-736, 2024 May.
Article de Allemand | MEDLINE | ID: mdl-38417809

RÉSUMÉ

Technical simulation of diagnostic and therapeutic procedures is of growing relevance for student education and advanced medical training and has already been introduced in the field of ultrasound. This review gives a broad overview on different levels of simulation for ultrasound diagnostics and highlights the technical background of the methodology. A critical review of the literature reveals recommendations for implementing simulation techniques in medical studies and professional ultrasound training. An analysis of strengths and weaknesses shows the advantages of simulation especially in the context of individual learning situations and COVID-19-related restrictions for personal interaction. However, simulation techniques cannot replace the experiences of complex clinical examinations with direct interaction to real patients. Therefore, future applications may focus on repetition and assessment of achieved competencies by using standardized feedback mechanisms in order to preserve the limited resources for practical medical training.


Sujet(s)
COVID-19 , Humains , Échographie/méthodes , Programme d'études , Formation par simulation/méthodes , Allemagne , Compétence clinique , Enseignement médical/tendances , Enseignement médical/méthodes , Simulation numérique
15.
Med Ultrason ; 2024 Jan 20.
Article de Anglais | MEDLINE | ID: mdl-38244219

RÉSUMÉ

The diagnosis or rare, non-hematologic malignant lesions of the liver may be a challenge owing to the rarity of the disease, and is usually made by histological confirmation. Ultrasound with color Doppler and contrast-enhanced, if required, taking into account the clinical background of the patient, may help to focus the differential diagnosis. In this review, we describe the pathological and ultrasound features of rare malignant neuroendocrine and predominantly epithelioid liver lesions including primary neuroendocrine tumor of the liver, Invasive mucinous cystic neoplasm of the liver, and also hepatoblastoma.

16.
Radiology ; 310(1): e232742, 2024 Jan.
Article de Anglais | MEDLINE | ID: mdl-38226876
17.
Ultraschall Med ; 45(2): 118-146, 2024 Apr.
Article de Anglais, Allemand | MEDLINE | ID: mdl-38237634

RÉSUMÉ

The CME review presented here is intended to explain the significance of pleural sonography to the interested reader and to provide information on its application. At the beginning of sonography in the 80 s of the 20th centuries, with the possible resolution of the devices at that time, the pleura could only be perceived as a white line. Due to the high impedance differences, the pleura can be delineated particularly well. With the increasing high-resolution devices of more than 10 MHz, even a normal pleura with a thickness of 0.2 mm can be assessed. This article explains the special features of the examination technique with knowledge of the pre-test probability and describes the indications for pleural sonography. Pleural sonography has a high value in emergency and intensive care medicine, preclinical, outpatient and inpatient, in the general practitioner as well as in the specialist practice of pneumologists. The special features in childhood (pediatrics) as well as in geriatrics are presented. The recognition of a pneumothorax even in difficult situations as well as the assessment of pleural effusion are explained. With the high-resolution technology, both the pleura itself and small subpleural consolidations can be assessed and used diagnostically. Both the direct and indirect sonographic signs and accompanying symptoms are described, and the concrete clinical significance of sonography is presented. The significance and criteria of conventional brightness-encoded B-scan, colour Doppler sonography (CDS) with or without spectral analysis of the Doppler signal (SDS) and contrast medium ultrasound (CEUS) are outlined. Elastography and ultrasound-guided interventions are also mentioned. A related further paper deals with the diseases of the lung parenchyma and another paper with the diseases of the thoracic wall, diaphragm and mediastinum.


Sujet(s)
Maladies pulmonaires , Épanchement pleural , Humains , Enfant , Plèvre/imagerie diagnostique , Épanchement pleural/imagerie diagnostique , Poumon/imagerie diagnostique , Thorax , Échographie/méthodes
18.
Quant Imaging Med Surg ; 14(1): 408-420, 2024 Jan 03.
Article de Anglais | MEDLINE | ID: mdl-38223085

RÉSUMÉ

Background: The status of the axillary lymph node (ALN) in patients with breast cancer can critically inform clinical decision-making and prognosis. Preoperative evaluation of limited nodal burden (0-2 metastatic ALNs) and high nodal burden (≥3 metastatic ALNs) is vital for individual treatment in patients with breast cancer. Thus, this study aimed to evaluate the value of Angio-PLUS (AP; Aixplorer, SuperSonic Imagine) and the qualitative and quantitative shear-wave elastography (SWE) of breast lesions to predict limited or high axillary nodal burden and to develop a model for predicting limited or high axillary nodal burden. Methods: From March 2020 to November 2022, a total of 232 consecutive patients with breast cancer comprising 232 breast lesions were enrolled retrospectively from Yueyang Central Hospital. The sensitivity, specificity, negative predictive value (NPV), positive predictive value (PPV), accuracy, and area under the receiver operating characteristic curve (AUC) of AP, qualitative SWE, quantitative SWE, and the predictive model for evaluating limited or high axillary nodal burden were compared. Results: There was no significant difference in AP patterns between the limited nodal burden group and high nodal burden group. The best cutoff values of Emin (the minimal value of the first Q-box), Emean (the mean value of the first Q-box), Emax (the maximum value of the first Q-box), Eratio (ratio of the first Q-Box and the second Q-Box) and standard deviation for predicting limited or high nodal burden were 80.85 KPa, 133.45 KPa, 153.40 KPa, 9.95, and 19.25 KPa, respectively. The Emax had the highest AUC, and its sensitivity, specificity, PPV, NPV, accuracy, and AUC were 71.64%, 56.36%, 40.00%, 83.04%, 60.78%, and 0.640 [95% confidence interval (CI): 0.575-0.702], respectively. The sensitivity, specificity, PPV, NPV, accuracy, and AUC of seven color patterns for qualitative SWE were 71.64%, 74.55%, 53.33%, 86.62%, 73.71%, and 0.731 (95% CI: 0.669-0.787), respectively, which was significantly higher than all the other quantitative SWE parameters. ALN evaluation in ultrasound and qualitative SWE were independent risk factors for predicting limited or high nodal burden according to a binary logistics regression analysis. The AUC of the predictive model based on independent risk factors was 0.820 (95% CI: 0.765-0.867), which was significantly higher than that of the other independent risk factors. Conclusions: The seven color patterns in the qualitative SWE of breast lesions were valuable for predicting limited or high nodal burden for patients with breast cancer. Compared with quantitative SWE, qualitative SWE exhibited a better diagnostic performance. Breast lesions present no findings, vertical stripes, and spot patterns were important indicators for limited nodal burden. The predictive model developed in this study could be a simple, noninvasive, and convenient method for predicting limited or high nodal burden, which would be beneficial for clinical decision-making and individual treatment to improve prognosis.

19.
Ultraschall Med ; 45(1): 36-46, 2024 Feb.
Article de Anglais | MEDLINE | ID: mdl-37748503

RÉSUMÉ

Dynamic contrast-enhanced ultrasound (DCE-US) is a technique to quantify tissue perfusion based on phase-specific enhancement after the injection of microbubble contrast agents for diagnostic ultrasound. The guidelines of the European Federation of Societies for Ultrasound in Medicine and Biology (EFSUMB) published in 2004 and updated in 2008, 2011, and 2020 focused on the use of contrast-enhanced ultrasound (CEUS), including essential technical requirements, training, investigational procedures and steps, guidance regarding image interpretation, established and recommended clinical indications, and safety considerations. However, the quantification of phase-specific enhancement patterns acquired with ultrasound contrast agents (UCAs) is not discussed here. The purpose of this EFSUMB Technical Review is to further establish a basis for the standardization of DCE-US focusing on treatment monitoring in oncology. It provides some recommendations and descriptions as to how to quantify dynamic ultrasound contrast enhancement, and technical explanations for the analysis of time-intensity curves (TICs). This update of the 2012 EFSUMB introduction to DCE-US includes clinical aspects for data collection, analysis, and interpretation that have emerged from recent studies. The current study not only aims to support future work in this research field but also to facilitate a transition to clinical routine use of DCE-US.


Sujet(s)
Produits de contraste , Tumeurs , Humains , Échographie/méthodes , Perfusion
20.
Med Ultrason ; 26(1): 72-82, 2024 Mar 27.
Article de Anglais | MEDLINE | ID: mdl-38150700

RÉSUMÉ

With the Superb Micro-Vascular Imaging (SMI), the established Doppler technology has been extended by another mode. With this technique, microvascular structures with slow blood flow can now also be displayed in real time. As with the introduction of Doppler ultrasound, this new technique opens further diagnostic fields for the examiner, which were previously reserved for magnetic resonance imaging (MRI), computed tomography (CT) or contrast ultrasound (CEUS). Focal nodular hyperplasia (FNH) of the liver is characterized by a typical spoke-wheel vascular malformation (spoke-wheel sign, SWS) anda good example using SMI for the diagnostic profit of our patients. The aim of this report is to describe the use of SMI as a new non-invasive, quick, and probably cost-effective diagnostic imaging tool.


Sujet(s)
Hyperplasie focale nodulaire , Humains , Hyperplasie focale nodulaire/imagerie diagnostique , Produits de contraste , Échographie/méthodes , Échographie-doppler , Foie/imagerie diagnostique , Diagnostic différentiel