Your browser doesn't support javascript.
loading
Montrer: 20 | 50 | 100
Résultats 1 - 20 de 63
Filtrer
1.
Rev Sci Instrum ; 94(6)2023 Jun 01.
Article de Anglais | MEDLINE | ID: mdl-37862497

RÉSUMÉ

Neutrons generated in Inertial Confinement Fusion (ICF) experiments provide valuable information to interpret the conditions reached in the plasma. The neutron time-of-flight (nToF) technique is well suited for measuring the neutron energy spectrum due to the short time (100 ps) over which neutrons are typically emitted in ICF experiments. By locating detectors 10s of meters from the source, the neutron energy spectrum can be measured to high precision. We present a contextual review of the current state of the art in nToF detectors at ICF facilities in the United States, outlining the physics that can be measured, the detector technologies currently deployed and analysis techniques used.

2.
Rev Sci Instrum ; 93(11): 113528, 2022 Nov 01.
Article de Anglais | MEDLINE | ID: mdl-36461449

RÉSUMÉ

In the dynamic environment of burning, thermonuclear deuterium-tritium plasmas, diagnosing the time-resolved neutron energy spectrum is of critical importance. Strategies exist for this diagnosis in magnetic confinement fusion plasmas, which presently have a lifetime of ∼1012 longer than inertial confinement fusion (ICF) plasmas. Here, we present a novel concept for a simple, precise, and scale-able diagnostic to measure time-resolved neutron spectra in ICF plasmas. The concept leverages general tomographic reconstruction techniques adapted to time-of-flight parameter space, and then employs an updated Monte Carlo algorithm and National Ignition Facility-relevant constraints to reconstruct the time-evolving neutron energy spectrum. Reconstructed spectra of the primary 14.028 MeV nDT peak are in good agreement with the exact synthetic spectra. The technique is also used to reconstruct the time-evolving downscattered spectrum, although the present implementation shows significantly more error.

3.
Rev Sci Instrum ; 93(11): 113550, 2022 Nov 01.
Article de Anglais | MEDLINE | ID: mdl-36461502

RÉSUMÉ

The analysis of the National Ignition Facility (NIF) neutron time-of-flight (nToF) detectors uses a forward-fit routine that depends critically on the instrument response functions (IRFs) of the diagnostics. The details of the IRFs used can have large impacts on measurements such as ion temperature and down-scattered ratio (DSR). Here, we report on the recent steps taken to construct and validate nToF IRFs at the NIF to an increased degree of accuracy, as well as remove the need for fixed DSR baseline offsets. The IRF is treated in two parts: a "core," measured experimentally with an x-ray impulse source, and a "tail" that occurs later in time and has limited experimental data. The tail region is calibrated with the data from indirect drive exploding pusher shots, which have little neutron scattering and are traditionally assumed to have zero DSR. Using analytic modeling estimates, the non-zero DSR for these shots is estimated. The impact of varying IRF tail components on DSR is investigated with a systematic parameter study, and good agreement is found with the non-zero DSR estimates. These approaches will be used to improve the precision and uncertainty of NIF nToF DSR measurements.

4.
Rev Sci Instrum ; 93(11): 113536, 2022 Nov 01.
Article de Anglais | MEDLINE | ID: mdl-36461534

RÉSUMÉ

A concept for using an intermediate distance (0.3-3.0 m) neutron time-of-flight (nToF) to provide a constraint on the measurement of the time-dependence of ion temperature in inertial confinement fusion implosions is presented. Simulated nToF signals at different distances are generated and, with a priori knowledge of the burn-averaged quantities and burn history, analyzed to determine requirements for a future detector. Results indicate a signal-to-noise ratio >50 and time resolution <20 ps to constrain the ion temperature gradient to ∼±25% (0.5 keV/100 ps).

5.
Rev Sci Instrum ; 93(10): 103543, 2022 Oct 01.
Article de Anglais | MEDLINE | ID: mdl-36319345

RÉSUMÉ

Inertial confinement fusion experiments at both the National Ignition Facility (NIF) and the Laboratory for Laser Energetics OMEGA laser facility currently utilize Cherenkov detectors, with fused silica as the Cherenkov medium. At the NIF, the Quartz Cherenkov Detectors improve the precision of neutron time-of-flight measurements; and at OMEGA, the Diagnostic for Areal Density provides measurements of capsule shell areal densities. An inherent property of fused silica is the radiator's relatively low energy threshold for Cherenkov photon production (Ethreshold < 1 MeV), making it advantageous over gas-based Cherenkov detectors for experiments requiring low-energy γ detection. The Vacuum Cherenkov Detector (VCD) has been specifically designed for efficient detection of low energy γ's. Its primary use is in implosion experiments, which will study reactions relevant to stellar and big-bang nucleosynthesis, such as T(4He,γ)7Li, 4He(3He,γ)7Be, and 12C(p,γ)13N. The VCD is compatible with LLE's standard Ten-Inch Manipulator diagnostic insertion module. This work will outline the design and characterization of the VCD as well as provide results from recent experiments conducted at the OMEGA laser facility.

6.
Am J Respir Crit Care Med ; 206(1): 81-93, 2022 07 01.
Article de Anglais | MEDLINE | ID: mdl-35316153

RÉSUMÉ

Rationale: Autoimmunity is believed to play a role in idiopathic pulmonary arterial hypertension (IPAH). It is not clear whether this is causative or a bystander of disease and if it carries any prognostic or treatment significance. Objectives: To study autoimmunity in IPAH using a large cross-sectional cohort. Methods: Assessment of the circulating immune cell phenotype was undertaken using flow cytometry, and the profile of serum immunoglobulins was generated using a standardized multiplex array of 19 clinically validated autoantibodies in 473 cases and 946 control subjects. Additional glutathione S-transferase fusion array and ELISA data were used to identify a serum autoantibody to BMPR2 (bone morphogenetic protein receptor type 2). Clustering analyses and clinical correlations were used to determine associations between immunogenicity and clinical outcomes. Measurements and Main Results: Flow cytometric immune profiling demonstrates that IPAH is associated with an altered humoral immune response in addition to raised IgG3. Multiplexed autoantibodies were significantly raised in IPAH, and clustering demonstrated three distinct clusters: "high autoantibody," "low autoantibody," and a small "intermediate" cluster exhibiting high concentrations of ribonucleic protein complex. The high-autoantibody cluster had worse hemodynamics but improved survival. A small subset of patients demonstrated immunoglobulin reactivity to BMPR2. Conclusions: This study establishes aberrant immune regulation and presence of autoantibodies as key features in the profile of a significant proportion of patients with IPAH and is associated with clinical outcomes.


Sujet(s)
Auto-immunité , Hypertension pulmonaire , Autoanticorps , Études transversales , Hypertension artérielle pulmonaire primitive familiale , Humains , Hypertension pulmonaire/génétique
7.
Phys Rev Lett ; 127(12): 125001, 2021 Sep 17.
Article de Anglais | MEDLINE | ID: mdl-34597087

RÉSUMÉ

Inertial confinement fusion implosions designed to have minimal fluid motion at peak compression often show significant linear flows in the laboratory, attributable per simulations to percent-level imbalances in the laser drive illumination symmetry. We present experimental results which intentionally varied the mode 1 drive imbalance by up to 4% to test hydrodynamic predictions of flows and the resultant imploded core asymmetries and performance, as measured by a combination of DT neutron spectroscopy and high-resolution x-ray core imaging. Neutron yields decrease by up to 50%, and anisotropic neutron Doppler broadening increases by 20%, in agreement with simulations. Furthermore, a tracer jet from the capsule fill-tube perturbation that is entrained by the hot-spot flow confirms the average flow speeds deduced from neutron spectroscopy.

8.
Rev Sci Instrum ; 92(5): 053526, 2021 May 01.
Article de Anglais | MEDLINE | ID: mdl-34243327

RÉSUMÉ

Recent inertial confinement fusion measurements have highlighted the importance of 3D asymmetry effects on implosion performance. One prominent example is the bulk drift velocity of the deuterium-tritium plasma undergoing fusion ("hotspot"), vHS. Upgrades to the National Ignition Facility neutron time-of-flight diagnostics now provide vHS to better than 1 part in 104 and enable cross correlations with other measurements. This work presents the impact of vHS on the neutron yield, downscatter ratio, apparent ion temperature, electron temperature, and 2D x-ray emission. The necessary improvements to diagnostic suites to take these measurements are also detailed. The benefits of using cross-diagnostic analysis to test hotspot models and theory are discussed, and cross-shot trends are shown.

9.
Rev Sci Instrum ; 92(4): 043555, 2021 Apr 01.
Article de Anglais | MEDLINE | ID: mdl-34243390

RÉSUMÉ

The time-resolved measurement of neutrons emitted from nuclear implosions at inertial confinement fusion facilities is used to characterize the fusing plasma. Several significant quantities are routinely measured by neutron time-of-flight (nToF) detectors in these experiments. Current nToF detectors use scintillators as well as solid-state Cherenkov radiators. The latter has an inherently faster time response and can provide a co-registered γ-ray measurement as well as improved precision in the bulk hot-spot velocity. This work discusses a nToF ellipsoidal detector that also utilizes a solid-state Cherenkov radiator. The detector has the potential to achieve a fast instrument response function allowing for characterization of the γ-ray burn history as well as the ability to field the detector closer to the fusion source. Proof-of-concept testing of the nToF ellipsoidal detector has been conducted at the National Ignition Facility using commercial optics. A time-resolved neutron signal has been measured from the diagnostic. Preliminary simulations corroborate the results.

10.
Rev Sci Instrum ; 92(4): 043512, 2021 Apr 01.
Article de Anglais | MEDLINE | ID: mdl-34243456

RÉSUMÉ

Nuclear diagnostics provide measurements of inertial confinement fusion implosions used as metrics of performance for the shot. The interpretation of these measurements for shots with low mode asymmetries requires a way of combining the data to produce a "sky map" where the individual line-of-sight values are used to interpolate to other positions in the sky. These interpolations can provide information regarding the orientation of the low mode asymmetries. We describe the interpolation method, associated uncertainties, and correlations between different metrics, e.g., Tion, down scatter ratio, and hot-spot velocity direction. This work is also related to recently reported studies [H. G. Rinderknecht et al., Phys. Rev. Lett. 124, 145002 (2020) and K. M. Woo et al., Phys. Plasmas 27, 062702 (2020)] of low mode asymmetries. We report an analysis that makes use of a newly commissioned line of sight, a scheme for incorporating multiple neutron spectrum measurement types, and recent work on the sources of implosion asymmetry to provide a more complete picture of implosion performance.

11.
Rev Sci Instrum ; 92(6): 063520, 2021 Jun 01.
Article de Anglais | MEDLINE | ID: mdl-34243585

RÉSUMÉ

A NASA-built x-ray microcalorimeter spectrometer has been installed on the MST facility at the Wisconsin Plasma Physics Laboratory and has recorded x-ray photons emitted by impurity ions of aluminum in a majority deuterium plasma. Much of the x-ray microcalorimeter development has been driven by the needs of astrophysics missions, where imaging arrays with few-eV spectral resolution are required. The goal of our project is to adapt these single-photon-counting microcalorimeters for magnetic fusion energy research and demonstrate the value of such measurements for fusion science. Microcalorimeter spectrometers combine the best characteristics of the x-ray instrumentation currently available on fusion devices: high spectral resolution similar to an x-ray crystal spectrometer and the broadband coverage of an x-ray pulse height analysis system. Fusion experiments are increasingly employing high-Z plasma-facing components and require measurement of the concentration of all impurity ion species in the plasma. This diagnostic has the capability to satisfy this need for multi-species impurity ion data and will also contribute to measurements of impurity ion temperature and flow velocity, Zeff, and electron density. Here, we introduce x-ray microcalorimeter detectors and discuss the diagnostic capability for magnetic fusion energy experiments. We describe our experimental setup and spectrometer operation approach at MST, and we present the results from an initial measurement campaign.

12.
Rev Sci Instrum ; 92(2): 023516, 2021 Feb 01.
Article de Anglais | MEDLINE | ID: mdl-33648072

RÉSUMÉ

Measurement of the neutron spectrum from inertial confinement fusion implosions is one of the primary diagnostics of implosion performance. Analysis of the spectrum gives access to quantities such as neutron yield, hot-spot velocity, apparent ion temperature, and compressed fuel ρr through measurement of the down-scatter ratio. On the National Ignition Facility, the neutron time-of-flight suite has been upgraded to include five independent, collimated lines of sight, each comprising a high dynamic range bibenzyl/diphenylacetylene-stilbene scintillator [R. Hatarik et al., Plasma Fusion Res. 9, 4404104 (2014)] and high-speed fused silica Cherenkov detectors [A. S. Moore et al., Rev. Sci. Instrum. 89, 10I120 (2018)].

13.
Rev Sci Instrum ; 92(2): 023513, 2021 Feb 01.
Article de Anglais | MEDLINE | ID: mdl-33648112

RÉSUMÉ

The measurement of plasma hotspot velocity provides an important diagnostic of implosion performance for inertial confinement fusion experiments at the National Ignition Facility. The shift of the fusion product neutron mean kinetic energy as measured along multiple line-of-sight time-of-flight spectrometers provides velocity vector components from which the hotspot velocity is inferred. Multiple measurements improve the hotspot velocity inference; however, practical considerations of available space, operational overhead, and instrumentation costs limit the number of possible line-of-sight measurements. We propose a solution to this classical "experiment design" problem that optimizes the precision of the velocity inference for a limited number of measurements.

14.
Rev Sci Instrum ; 91(8): 083110, 2020 Aug 01.
Article de Anglais | MEDLINE | ID: mdl-32872938

RÉSUMÉ

X-ray calorimeters routinely achieve very high spectral resolution, typically a few eV full width at half maximum (FWHM). Measurements of calorimeter line shapes are usually dominated by the natural linewidth of most laboratory calibration sources. This compounds the data acquisition time necessary to statistically sample the instrumental line broadening and can add systematic uncertainty if the intrinsic line shape of the source is not well known. To address these issues, we have built a simple, compact monochromatic x-ray source using channel cut crystals. A commercial x-ray tube illuminates a pair of channel cut crystals that are aligned in a dispersive configuration to select the Kα1 line of the x-ray tube anode material. The entire device, including the x-ray tube, can be easily hand-carried by one person and may be positioned manually or using a mechanical translation stage. The output monochromatic beam provides a collimated image of the anode spot with magnification of unity in the dispersion direction (typically 100 µm-200 µm for the x-ray tubes used here) and is unfocused in the cross-dispersion direction so that the source image in the detector plane appears as a line. We measured output count rates as high as 10 count/s/pixel for the Hitomi soft x-ray spectrometer, which had 819 µm square pixels. We implemented different monochromator designs for energies of 5.4 keV (one design) and 8.0 keV (two designs), which have effective theoretical FWHM energy resolution of 0.125 eV, 0.197 eV, and 0.086 eV, respectively; these are well-suited for optimal calibration measurements of state-of-the art x-ray calorimeters. We measured an upper limit for the energy resolution of our Cr Kα1 monochromator of 0.7 eV FWHM at 5.4 keV, consistent with the theoretical prediction of 0.125 eV.

15.
Phys Rev Lett ; 123(16): 165001, 2019 Oct 18.
Article de Anglais | MEDLINE | ID: mdl-31702328

RÉSUMÉ

Neutron spectra from secondary ^{3}H(d,n)α reactions produced by an implosion of a deuterium-gas capsule at the National Ignition Facility have been measured with order-of-magnitude improvements in statistics and resolution over past experiments. These new data and their sensitivity to the energy loss of fast tritons emitted from thermal ^{2}H(d,p)^{3}H reactions enable the first statistically significant investigation of charged-particle stopping via the emitted neutron spectrum. Radiation-hydrodynamic simulations, constrained to match a number of observables from the implosion, were used to predict the neutron spectra while employing two different energy loss models. This analysis represents the first test of stopping models under inertial confinement fusion conditions, covering plasma temperatures of k_{B}T≈1-4 keV and particle densities of n≈(12-2)×10^{24} cm^{-3}. Under these conditions, we find significant deviations of our data from a theory employing classical collisions whereas the theory including quantum diffraction agrees with our data.

16.
Article de Anglais | MEDLINE | ID: mdl-31186605

RÉSUMÉ

With the improving energy resolution of transitionedge sensor (TES) based microcalorimeters, performance verification and calibration of these detectors has become increasingly challenging, especially in the energy range below 1 keV where fluorescent atomic X-ray lines have linewidths that are wider than the detector energy resolution and require impractically high statistics to determine the gain and deconvolve the instrumental profile. Better behaved calibration sources such as grating monochromators are too cumbersome for space missions and are difficult to use in the lab. As an alternative, we are exploring the use of pulses of 3 eV optical photons delivered by an optical fiber to generate combs of known energies with known arrival times. Here, we discuss initial results of this technique obtained with 2 eV and 0.7 eV resolution X-ray microcalorimeters. With the 2 eV detector, we have achieved photon number resolution for pulses with mean photon number up to 133 (corresponding to 0.4 keV).

17.
Rev Sci Instrum ; 89(10): 10I138, 2018 Oct.
Article de Anglais | MEDLINE | ID: mdl-30399709

RÉSUMÉ

An important diagnostic value of a shot at the National Ignition Facility is the resultant center-of-mass motion of the imploding capsule. This residual velocity reduces the efficiency of converting laser energy into plasma temperature. A new analysis method extracts the effective hot spot motion by using information from multiple neutron time-of-flight (nToF) lines-of-sight (LoSs). This technique fits a near Gaussian spectrum to the nToF scope traces and overcomes reliance on models to relate the plasma temperature to the mean energy of the emitted neutrons. This method requires having at least four nToF LoSs. The results of this analysis will be compared to an approach where each LoS is analyzed separately and a model is used to infer the mean energy of the emitted neutrons.

18.
Rev Sci Instrum ; 89(10): 10I136, 2018 Oct.
Article de Anglais | MEDLINE | ID: mdl-30399741

RÉSUMÉ

Neutron time-of-flight diagnostics at the NIF were recently outfitted with Cherenkov detectors. A fused silica radiator delivers sub-nanosecond response time and is optically coupled to a microchannel plate photomultiplier tube with gain from ∼1 to 104. Capitalizing on fast time response and gamma-ray sensitivity, these systems can provide better than 30 ps precision for measuring first moments of neutron distributions. Generation of ab initio instrument response functions (IRFs) is critical to meet the <1% uncertainty needed. A combination of Monte Carlo modeling, benchtop characterization, and in situ comparison is employed. Close agreement is shown between the modeled IRFs and in situ measurements using the NIF's short-pulse advanced radiographic capability beams. First and second moments of neutron spectra calculated using ab initio IRFs agree well with established scintillator measurements. Next-step designs offer increased sensitivity and time-response.

19.
Rev Sci Instrum ; 89(10): 10I120, 2018 Oct.
Article de Anglais | MEDLINE | ID: mdl-30399816

RÉSUMÉ

A fused silica Cherenkov radiator has been implemented at the National Ignition Facility to provide a new high precision measurement of the time-of-flight spectrum of 14.1 MeV DT fusion neutrons. This detector enables a high precision (<30 ps) co-registered measurement of both a thresholded γ-ray and a neutron spectrum on a single record. Other methods typically require γ and neutron signals to be co-registered via other diagnostics and/or dedicated timing experiments. Analysis of the co-registered γ and neutron signals allows precise extraction of the mean neutron energy and bulk hot-spot velocity, both of which were not possible with prior scintillator technologies. Initial measurements demonstrate the feasibility of this measurement and indicate that combined detection of neutrons and γ-rays on multiple lines-of-sight should enable the bulk vector velocity of the implosion hot-spot to be determined to ≈5 km/s and reduced uncertainty in the spectral width ≈0.1 keV.

20.
Rev Sci Instrum ; 89(10): 10F124, 2018 Oct.
Article de Anglais | MEDLINE | ID: mdl-30399834

RÉSUMÉ

The warm electron beam ion trap (WEBIT) at Lawrence Livermore National Laboratory is being developed as a pre-launch, ground calibration source for space-borne, high-throughput, high-resolution x-ray spectrometers, such as the x-ray imaging and spectroscopy mission Resolve quantum calorimeter. Historically, calibration sources for calorimeter spectrometers have relied on characteristic line emission from x-ray tubes, fluorescing metals, and radioactive sources. The WEBIT, by contrast, relies on emission from x-ray transitions in highly charged ions, for example, hydrogen-like and helium-like ions, whose energies are well known and whose line shapes are relatively simple. The WEBIT can create astrophysically relevant ions whose x-ray emission falls in the 0.3-12 keV science bandpass of Resolve and has a portable design advantageous for a calibration source. The WEBIT will be used to help calibrate Resolve's instrumental line shape and gain scale as a function of various operational parameters during both detector subsystem level testing and instrumental level testing.

SÉLECTION CITATIONS
DÉTAIL DE RECHERCHE
...