1.
Future Cardiol ; : 1-16, 2024 Jul 01.
Article de Anglais | MEDLINE | ID: mdl-38948932

RÉSUMÉ

Oral anticoagulation therapy (OAC) is a mainstay for mitigating stroke and other embolic events in patients with atrial fibrillation (AF). Despite the demonstrated efficacy of OAC in reducing events, many patients are unable to tolerate OAC due to bleeding risks. Left atrial appendage occlusion (LAAO) devices were developed as implantable technologies to moderate stroke risk in patients with intolerance to OAC. Despite clinical data supporting near-comparable protection against thromboembolic events with OAC, device-related thrombus formation has emerged as a critical complication following LAAO that remains a potential limitation to the safety and efficacy of LAAO. Improved biocompatibility of LAAO devices with fluoropolymers, a well-established stent-coating technology used to reduce thrombus formation and promote endothelialization, may optimize outcomes after LAAO.


[Box: see text].

2.
Article de Anglais | MEDLINE | ID: mdl-38869507

RÉSUMÉ

BACKGROUND: Autonomic denervation is an ancillary phenomenon during thermal ablation of atrial fibrillation (AF), that may have synergistic effects on symptomatic improvement and long-term freedom from AF. Pulsed field ablation (PFA), a nonthermal ablation modality, was noninferior to thermal ablation in treating AF; however, PFA's relative myocardial selectivity may minimize autonomic effects. OBJECTIVES: This study sought to compare heart rate (HR) and heart rate variability (HRV) metrics as markers of autonomic function after ablation using PFA vs thermal ablation. METHODS: ADVENT (The FARAPULSE ADVENT PIVOTAL Trial PFA System vs SOC Ablation for Paroxysmal Atrial Fibrillation) was a randomized pivotal study comparing PFA (pentaspline catheter) with thermal ablation (radiofrequency [RF] or cryoballoon [CB]) for treating paroxysmal AF. Baseline HR was acquired from a pre-ablation 12-lead electrocardiogram, whereas follow-up HRs, as well as HRV (standard deviation of all normal to normal RR intervals, standard deviation of 5-minute average RR intervals) metrics, were derived from 72-hour Holter monitors at 6 and 12 months. RESULTS: This study included 379 paroxysmal AF patients undergoing PFA (n = 194) or thermal ablation (n = 185; n = 102 RF, n = 83 CB) completing 6- and 12-month Holter monitoring. Compared with PFA, thermal patients had significantly greater increases in HR from baseline to 6 months (ΔHR; 10.1 vs 5.9 beats/min; P = 0.02) and 12 months (ΔHR; 8.8 vs 5.2 beats/min; P = 0.03). This increase in HR at 6 and 12 months was similar between CB and RF (P = 0.94 and 0.83, respectively). HRV, both standard deviation of all normal to normal RR intervals and standard deviation of 5-minute average RR intervals, were significantly lower at both 6 and 12 months after thermal ablation compared with PFA (P < 0.01). CONCLUSIONS: PFA's effect on the autonomic nervous system was attenuated compared with thermal ablation. Whether this affects long-term freedom from AF or symptomatic bradycardia/pauses after AF ablation requires further study.

3.
Heart Rhythm ; 2024 May 18.
Article de Anglais | MEDLINE | ID: mdl-38768843

RÉSUMÉ

BACKGROUND: Although expertise in left atrial appendage occlusion (LAAO) has grown, certain intricate anatomies may pose challenges, rendering them unsuitable for LAAO with the selected device. OBJECTIVE: This analysis aimed to characterize outcomes of patients with prior failed percutaneous LAAO procedures who underwent a subsequent attempt with an Amulet occluder in the EMERGE LAA postapproval study. METHODS: Patients enrolled in the National Cardiovascular Data Registry LAAO Registry who had an Amulet occluder implantation attempt between Food and Drug Administration approval (August 14, 2021) and June 30, 2023, were evaluated. A safety end point through 7 days or hospital discharge (whichever was later) and major adverse events through 45 days were reported. RESULTS: A total of 8591 patients underwent attempted Amulet occluder implantation, of whom 244 patients had prior failed LAAO. Implantation success was 88.9% and 96.2% in patients with prior failed LAAO and index LAAO, respectively (P < .001). The safety composite end point was low, occurring in 1.6% and 0.8% of patients with prior failed LAAO and index LAAO, respectively (P = .148). Any major adverse event through 45 days occurred in 7.4% and 6.3% of prior failed LAAO and index LAAO patient cohorts, respectively (P = .497); most adverse events were similar between the groups (P > .05). At 45 days, peridevice leak ≤3 mm was achieved in >90% of patients in either group. CONCLUSION: A high degree of implantation success with a low rate of adverse events can be achieved with the Amulet occluder. The findings imply that the dual occlusive mechanism Amulet occluder facilitates successful closure, even in challenging anatomic scenarios.

4.
JAMA ; 331(13): 1099-1108, 2024 04 02.
Article de Anglais | MEDLINE | ID: mdl-38563835

RÉSUMÉ

Importance: Left atrial appendage elimination may improve catheter ablation outcomes for atrial fibrillation. Objective: To assess the safety and effectiveness of percutaneous left atrial appendage ligation adjunctive to catheter pulmonary vein isolation for nonparoxysmal atrial fibrillation. Design, Setting, and Participants: This multicenter, prospective, open-label, randomized clinical trial evaluated the safety and effectiveness of percutaneous left atrial appendage ligation adjunctive to planned pulmonary vein isolation for nonparoxysmal atrial fibrillation present for less than 3 years. Eligible patients were randomized in a 2:1 ratio to undergo left atrial appendage ligation and pulmonary vein isolation or pulmonary vein isolation alone. Use of a 2:1 randomization ratio was intended to provide more device experience and safety data. Patients were enrolled from October 2015 to December 2019 at 53 US sites, with the final follow-up visit on April 21, 2021. Interventions: Left atrial appendage ligation plus pulmonary vein isolation compared with pulmonary vein isolation alone. Main Outcomes and Measures: A bayesian adaptive analysis was used for primary end points. Primary effectiveness was freedom from documented atrial arrythmias of greater than 30 seconds duration 12 months after undergoing pulmonary vein isolation. Rhythm was assessed by Holter monitoring at 6 and 12 months after pulmonary vein isolation, symptomatic event monitoring, or any electrocardiographic tracing obtained through 12 months after pulmonary vein isolation. Primary safety was a composite of predefined serious adverse events compared with a prespecified 10% performance goal 30 days after the procedure. Left atrial appendage closure was evaluated through 12 months after pulmonary vein isolation. Results: Overall, 404 patients were randomized to undergo left atrial appendage ligation plus pulmonary vein isolation and 206 were randomized to undergo pulmonary vein isolation alone. Primary effectiveness was 64.3% with left atrial appendage ligation and pulmonary vein isolation and 59.9% with pulmonary vein isolation only (difference, 4.3% [bayesian 95% credible interval, -4.2% to 13.2%]; posterior superiority probability, 0.835), which did not meet the statistical criterion to establish superiority (0.977). Primary safety was met, with a 30-day serious adverse event rate of 3.4% (bayesian 95% credible interval, 2.0% to 5.0%; posterior probability, 1.0) which was less than the prespecified threshold of 10%. At 12 months after pulmonary vein isolation, complete left atrial appendage closure (0 mm residual communication) was observed in 84% of patients and less than or equal to 5 mm residual communication was observed in 99% of patients. Conclusions and Relevance: Percutaneous left atrial appendage ligation adjunctive to pulmonary vein isolation did not meet prespecified efficacy criteria for freedom from atrial arrhythmias at 12 months compared with pulmonary vein isolation alone for patients with nonparoxysmal atrial fibrillation, but met prespecified safety criteria and demonstrated high rates of closure at 12 months. Trial Registration: ClinicalTrials.gov Identifier: NCT02513797.


Sujet(s)
Auricule de l'atrium , Fibrillation auriculaire , Composés organothiophosphorés , Veines pulmonaires , Humains , Auricule de l'atrium/chirurgie , Fibrillation auriculaire/chirurgie , Théorème de Bayes , Études prospectives , Veines pulmonaires/chirurgie , Ablation par cathéter , Cathétérisme
5.
Cardiovasc Revasc Med ; 64: 7-14, 2024 Jul.
Article de Anglais | MEDLINE | ID: mdl-38448258

RÉSUMÉ

BACKGROUND: Left atrial appendage (LAA) occluder embolization is an infrequent but serious complication. OBJECTIVES: We aim to describe timing, management and clinical outcomes of device embolization in a multi-center registry. METHODS: Patient characteristics, imaging findings and procedure and follow-up data were collected retrospectively. Device embolizations were categorized according to 1) timing 2) management and 3) clinical outcomes. RESULTS: Sixty-seven centers contributed data. Device embolization occurred in 108 patients. In 70.4 % of cases, it happened within the first 24 h of the procedure. The device was purposefully left in the LA and the aorta in two (1.9 %) patients, an initial percutaneous retrieval was attempted in 81 (75.0 %) and surgery without prior percutaneous retrieval attempt was performed in 23 (21.3 %) patients. Two patients died before a retrieval attempt could be made. In 28/81 (34.6 %) patients with an initial percutaneous retrieval attempt a second, additional attempt was performed, which was associated with a high mortality (death in patients with one attempt: 2.9 % vs. second attempt: 21.4 %, p < 0.001). The primary outcome (bailout surgery, cardiogenic shock, stroke, TIA, and/or death) occurred in 47 (43.5 %) patients. Other major complications related to device embolization occurred in 21 (19.4 %) patients. CONCLUSIONS: The majority of device embolizations after LAA closure occurs early. A percutaneous approach is often the preferred method for a first rescue attempt. Major adverse event rates, including death, are high particularly if the first retrieval attempt was unsuccessful. CONDENSED ABSTRACT: This dedicated multicenter registry examined timing, management, and clinical outcome of device embolization. Early embolization (70.4 %) was most frequent. As a first rescue attempt, percutaneous retrieval was preferred in 75.0 %, followed by surgical removal (21.3 %). In patients with a second retrieval attempt a higher mortality (death first attempt: 2.9 % vs. death second attempt: 24.1 %, p < 0.001) was observed. Mortality (10.2 %) and the major complication rate after device embolization were high.


Sujet(s)
Auricule de l'atrium , Fibrillation auriculaire , Cathétérisme cardiaque , Ablation de dispositif , Enregistrements , Humains , Mâle , Auricule de l'atrium/imagerie diagnostique , Auricule de l'atrium/physiopathologie , Femelle , Sujet âgé , Études rétrospectives , Résultat thérapeutique , Facteurs temps , Sujet âgé de 80 ans ou plus , Facteurs de risque , Cathétérisme cardiaque/effets indésirables , Cathétérisme cardiaque/instrumentation , Cathétérisme cardiaque/mortalité , Fibrillation auriculaire/thérapie , Fibrillation auriculaire/mortalité , Ablation de dispositif/effets indésirables , Embolie/étiologie , Embolie/mortalité , Adulte d'âge moyen , Dispositif d'occlusion septale ,
6.
J Am Heart Assoc ; 13(6): e031029, 2024 Mar 19.
Article de Anglais | MEDLINE | ID: mdl-38471835

RÉSUMÉ

BACKGROUND: Recurrence after atrial fibrillation (AF) ablation remains common. We evaluated the association between recurrence and levels of biomarkers of cardiac remodeling, and their ability to improve recurrence prediction when added to a clinical prediction model. METHODS AND RESULTS: Blood samples collected before de novo catheter ablation were analyzed. Levels of bone morphogenetic protein-10, angiopoietin-2, fibroblast growth factor-23, insulin-like growth factor-binding protein-7, myosin-binding protein C3, growth differentiation factor-15, interleukin-6, N-terminal pro-brain natriuretic peptide, and high-sensitivity troponin T were measured. Recurrence was defined as ≥30 seconds of an atrial arrhythmia 3 to 12 months postablation. Multivariable logistic regression was performed using biomarker levels along with clinical covariates: APPLE score (Age >65 years, Persistent AF, imPaired eGFR [<60 ml/min/1.73m2], LA diameter ≥43 mm, EF <50%; which includes age, left atrial diameter, left ventricular ejection fraction, persistent atrial fibrillation, and estimated glomerular filtration rate), preablation rhythm, sex, height, body mass index, presence of an implanted continuous monitor, year of ablation, and additional linear ablation. A total of 1873 participants were included. A multivariable logistic regression showed an association between recurrence and levels of angiopoietin-2 (odds ratio, 1.08 [95% CI, 1.02-1.15], P=0.007) and interleukin-6 (odds ratio, 1.02 [95% CI, 1.003-1.03]; P=0.02). The area under the receiver operating characteristic curve of a model that only contained clinical predictors was 0.711. The addition of any of the 9 studied biomarkers to the predictive model did not result in a statistically significant improvement in the area under the receiver operating characteristic curve. CONCLUSIONS: Higher angiopoietin-2 and interleukin-6 levels were associated with recurrence after atrial fibrillation ablation in multivariable modeling. However, the addition of biomarkers to a clinical prediction model did not significantly improve recurrence prediction.


Sujet(s)
Fibrillation auriculaire , Remodelage auriculaire , Ablation par cathéter , Humains , Sujet âgé , Fibrillation auriculaire/diagnostic , Fibrillation auriculaire/chirurgie , Angiopoïétine-2 , Interleukine-6 , Modèles statistiques , Débit systolique , Remodelage ventriculaire , Facteurs de risque , Pronostic , Récidive , Fonction ventriculaire gauche , Marqueurs biologiques , Ablation par cathéter/effets indésirables , Ablation par cathéter/méthodes , Résultat thérapeutique
7.
Article de Anglais | MEDLINE | ID: mdl-38310499

RÉSUMÉ

BACKGROUND: The Food and Drug Administration approved the Amulet occluder (Abbott) after demonstrating safety and effectiveness in the Amulet IDE (AMPLATZER Amulet LAA Occluder) trial. OBJECTIVES: The aim of the EMERGE Left Atrial Appendage study is to evaluate early postapproval outcomes of the Amulet occluder in the United States using data from the National Cardiovascular Data Registry Left Atrial Appendage Occlusion Registry. METHODS: Patients with a commercial Amulet occluder implant attempt between Food and Drug Administration approval (August 14, 2021) and December 31, 2022, were included. The safety composite endpoint included all-cause death, ischemic stroke, systemic embolism, or device/procedure-related events requiring open cardiac surgery or endovascular intervention between device implantation and 7 days or hospital discharge (whichever is later). Major adverse events through 45 days were also reported and stratified by operator experience (early [<10 cases], moderate [10-29 cases], and high [30+ cases]). RESULTS: A total of 5,499 patients underwent attempted Amulet occluder implantation. Implant success was 95.8%, and complete closure was 97.2% post-left atrial appendage occlusion and 87.1% at 45 days. A safety composite endpoint event occurred in 0.76% patients. Any major adverse event occurred in 2.9% and 5.7% of patients in-hospital and through 45 days, respectively, driven by major bleeding and pericardial effusion (PE) requiring intervention. PE requiring surgery or percutaneous intervention decreased significantly with increasing experience both in-hospital (early vs high operator experience 1.8% vs 1.1%; P = 0.006) and at 45 days (2.3% vs 1.5%; P = 0.012). CONCLUSIONS: The EMERGE Left Atrial Appendage study demonstrates favorable safety and effectiveness of the Amulet occluder in the real-world setting. More experienced operators had improved implant success and fewer PEs, suggesting a learning curve effect implanting this dual occlusive mechanism device.

9.
N Engl J Med ; 389(18): 1660-1671, 2023 Nov 02.
Article de Anglais | MEDLINE | ID: mdl-37634148

RÉSUMÉ

BACKGROUND: Catheter-based pulmonary vein isolation is an effective treatment for paroxysmal atrial fibrillation. Pulsed field ablation, which delivers microsecond high-voltage electrical fields, may limit damage to tissues outside the myocardium. The efficacy and safety of pulsed field ablation as compared with conventional thermal ablation are not known. METHODS: In this randomized, single-blind, noninferiority trial, we assigned patients with drug-refractory paroxysmal atrial fibrillation in a 1:1 ratio to undergo pulsed field ablation or conventional radiofrequency or cryoballoon ablation. The primary efficacy end point was freedom from a composite of initial procedural failure, documented atrial tachyarrhythmia after a 3-month blanking period, antiarrhythmic drug use, cardioversion, or repeat ablation. The primary safety end point included acute and chronic device- and procedure-related serious adverse events. RESULTS: A total of 305 patients were assigned to undergo pulsed field ablation, and 302 were assigned to undergo thermal ablation. At 1 year, the primary efficacy end point was met (i.e., no events occurred) in 204 patients (estimated probability, 73.3%) who underwent pulsed field ablation and 194 patients (estimated probability, 71.3%) who underwent thermal ablation (between-group difference, 2.0 percentage points; 95% Bayesian credible interval, -5.2 to 9.2; posterior probability of noninferiority, >0.999). Primary safety end-point events occurred in 6 patients (estimated incidence, 2.1%) who underwent pulsed field ablation and 4 patients (estimated incidence, 1.5%) who underwent thermal ablation (between-group difference, 0.6 percentage points; 95% Bayesian credible interval, -1.5 to 2.8; posterior probability of noninferiority, >0.999). CONCLUSIONS: Among patients with paroxysmal atrial fibrillation receiving a catheter-based therapy, pulsed field ablation was noninferior to conventional thermal ablation with respect to freedom from a composite of initial procedural failure, documented atrial tachyarrhythmia after a 3-month blanking period, antiarrhythmic drug use, cardioversion, or repeat ablation and with respect to device- and procedure-related serious adverse events at 1 year. (Funded by Farapulse-Boston Scientific; ADVENT ClinicalTrials.gov number, NCT04612244.).


Sujet(s)
Fibrillation auriculaire , Ablation par cathéter , Veines pulmonaires , Humains , Fibrillation auriculaire/classification , Fibrillation auriculaire/chirurgie , Théorème de Bayes , Ablation par cathéter/effets indésirables , Ablation par cathéter/méthodes , Veines pulmonaires/chirurgie , Récidive , Méthode en simple aveugle , Tachycardie/étiologie , Résultat thérapeutique
10.
JACC Cardiovasc Interv ; 16(15): 1902-1913, 2023 08 14.
Article de Anglais | MEDLINE | ID: mdl-37587599

RÉSUMÉ

BACKGROUND: The Amulet (Abbott) left atrial appendage occluder investigational device exemption trial is the largest randomized trial evaluating the safety and effectiveness of the Amulet left atrial appendage occluder compared with the Watchman 2.5 device (Boston Scientific) through 5 years. OBJECTIVES: This analysis evaluated the device effect on 3-year outcomes in the Amulet investigational device exemption trial. METHODS: The medication regimen and key clinical outcomes were reported through 3 years including: 1) the composite of ischemic stroke or systemic embolism (SE); 2) the composite of all strokes, SE, or cardiovascular (CV) death; 3) major bleeding; and 4) all-cause death and CV death. RESULTS: A total of 1,878 patients at 108 sites were randomized. A significantly higher percentage of patients were free of oral anticoagulation usage at 3 years with Amulet (96.2%) vs Watchman (92.5%) (P < 0.01). Clinical outcomes were comparable for the composite of ischemic stroke or SE (5.0% vs 4.6%; P = 0.69); the composite of all strokes, SE, or CV death (11.1% vs 12.7%; P = 0.31); major bleeding (16.1% vs 14.7%; P = 0.46); all-cause death (14.6% vs 17.9%; P = 0.08); and CV death (6.6% vs 8.5%; P = 0.14) for Amulet and Watchman, respectively. Through 3 years, device factors (device-related thrombus or peridevice leak ≥3 mm) preceded ischemic stroke events and CV deaths more frequently in Watchman compared with Amulet patients. CONCLUSIONS: The Amulet occluder demonstrated continued safety and effectiveness with over 96% free of oral anticoagulation usage through 3 years in a high-risk population compared to the Watchman device. (AMPLATZER Amulet LAA Occluder Trial [Amulet IDE]; NCT02879448).


Sujet(s)
Auricule de l'atrium , Accident vasculaire cérébral ischémique , Accident vasculaire cérébral , Humains , Auricule de l'atrium/imagerie diagnostique , Résultat thérapeutique , Accident vasculaire cérébral/étiologie , Anticoagulants
11.
Europace ; 25(9)2023 08 02.
Article de Anglais | MEDLINE | ID: mdl-37584233

RÉSUMÉ

AIMS: Incomplete left atrial appendage occlusion (LAAO) due to peri-device leak (PDL) is a limitation of the therapy. The Amulet IDE trial is the largest randomized head-to-head trial comparing the Amulet and Watchman 2.5 LAAO devices with fundamentally different designs. The predictors and mechanistic factors impacting differences in PDLs within the Amulet IDE trial are assessed in the current analysis. METHODS AND RESULTS: An independent core lab analysed all images for the presence or absence of severe PDL (>5 mm). The incidence, mechanistic factors, predictors using propensity score-matched controls, and evolution of severe PDLs through 18 months were assessed. Of the 1878 patients randomized in the trial, the Amulet occluder had significantly fewer severe PDLs than the Watchman device at 45 days (1.1 vs. 3.2%, P < 0.001) and 12 months (0.1 vs. 1.1%, P < 0.001). Off-axis deployment or missed lobes were leading mechanistic PDL factors in each device group. Larger left atrial appendage (LAA) dimensions including orifice diameter, landing zone diameter, and depth predicted severe PDL with the Watchman device, with no significant anatomical limitations noted with the Amulet occluder. Procedural and device implant predictors were found with the Amulet occluder attributed to the learning curve with the device. A majority of Watchman device severe PDLs did not resolve over time through 18 months. CONCLUSION: The dual-occlusive Amplatzer Amulet LAA occluder provided improved LAA closure compared with the Watchman 2.5 device. Predictors and temporal observations of severe PDLs were identified in the Amulet IDE trial. CLINICAL TRIAL REGISTRATION: https://clinicaltrials.gov Unique identifier NCT02879448.


Sujet(s)
Auricule de l'atrium , Fibrillation auriculaire , Procédures de chirurgie cardiaque , Dispositif d'occlusion septale , Accident vasculaire cérébral , Humains , Auricule de l'atrium/imagerie diagnostique , Auricule de l'atrium/chirurgie , Fibrillation auriculaire/diagnostic , Fibrillation auriculaire/chirurgie , Fibrillation auriculaire/complications , Procédures de chirurgie cardiaque/effets indésirables , Résultat thérapeutique , Dispositif d'occlusion septale/effets indésirables , Cathétérisme cardiaque/effets indésirables , Accident vasculaire cérébral/étiologie
12.
JACC Clin Electrophysiol ; 9(7 Pt 2): 1147-1157, 2023 07.
Article de Anglais | MEDLINE | ID: mdl-37495323

RÉSUMÉ

BACKGROUND: Experimental evidence suggests genetic variation in 4q25/PITX2 modulates pulmonary vein (PV) myocardial sleeve length. Although PV sleeves are the main target of atrial fibrillation (AF) ablation, little is known about the association between different PV sleeve characteristics with ablation outcomes. OBJECTIVES: This study sought to evaluate the association between clinical and genetic (4q25) risk factors with PV sleeve length in humans, and to evaluate the association between PV sleeve length and recurrence after AF ablation. METHODS: In a prospective, observational study of patients undergoing de novo AF ablation, PV sleeve length was measured using electroanatomic voltage mapping before ablation. The sentinel 4q25 AF susceptibility single nucleotide polymorphism, rs2200733, was genotyped. The primary analysis tested the association between clinical and genetic (4q25) risk factors with PV sleeve length using a multivariable linear regression model. Covariates included age, sex, body mass index, height, and persistent AF. The association between PV sleeve length and atrial arrhythmia recurrence (>30 seconds) was tested using a multivariable Cox proportional hazards model. RESULTS: Between 2014 and 2019, 197 participants were enrolled (median age 63 years [IQR: 55 to 70 years], 133 male [67.5%]). In multivariable modeling, men were found to have PV sleeves 2.94 mm longer than women (95% CI: 0.99-4.90 mm; P < 0.001). Sixty participants (30.5%) had one 4q25 risk allele and 6 (3.1%) had 2 alleles. There was no association between 4q25 genotype and PV sleeve length. Forty-six participants (23.4%) experienced arrhythmia recurrence within 3 to 12 months, but there was no association between recurrence and PV sleeve length. CONCLUSIONS: Common genetic variation at 4q25 was not associated with PV sleeve length and PV sleeve length was not associated with ablation outcomes. Men did have longer PV sleeves than women, but more research is needed to define the potential clinical significance of this observation.


Sujet(s)
Fibrillation auriculaire , Veines pulmonaires , Femelle , Humains , Mâle , Adulte d'âge moyen , Fibrillation auriculaire/génétique , Fibrillation auriculaire/chirurgie , Génotype , Études prospectives , Veines pulmonaires/chirurgie , Facteurs de risque , Sujet âgé ,
14.
bioRxiv ; 2023 Mar 07.
Article de Anglais | MEDLINE | ID: mdl-36945599

RÉSUMÉ

The nation's opioid overdose deaths reached an all-time high in 2021. The majority of deaths are due to synthetic opioids represented by fentanyl. Naloxone, which is an FDA-approved reversal agent, antagonizes opioids through competitive binding at the mu-opioid receptor (mOR). Thus, knowledge of opioid's residence time is important for assessing the effectiveness of naloxone. Here we estimated the residence times of 15 fentanyl and 4 morphine analogs using metadynamics, and compared them with the most recent measurement of the opioid kinetic, dissociation, and naloxone inhibitory constants (Mann, Li et al, Clin. Pharmacol. Therapeut. 2022). Importantly, the microscopic simulations offered a glimpse at the common binding mechanism and molecular determinants of dissociation kinetics for fentanyl analogs. The insights inspired us to develop a machine learning (ML) approach to analyze the kinetic impact of fentanyl's substituents based on the interactions with mOR residues. This proof-of-concept approach is general; for example, it may be used to tune ligand residence times in computer-aided drug discovery.

15.
JACC Cardiovasc Interv ; 16(6): 627-642, 2023 03 27.
Article de Anglais | MEDLINE | ID: mdl-36990553

RÉSUMÉ

Left atrial appendage occlusion is an increasingly adopted stroke prevention strategy in patients with atrial fibrillation. However, peridevice leaks after the procedure are not infrequent and have recently been shown to confer a higher risk for subsequent ischemic events. In this paper, the authors review the available research on the frequency, mechanisms, clinical significance, and management of peridevice leak after percutaneous left atrial appendage occlusion.


Sujet(s)
Auricule de l'atrium , Fibrillation auriculaire , Accident vasculaire cérébral , Humains , Incidence , Auricule de l'atrium/imagerie diagnostique , Résultat thérapeutique , Accident vasculaire cérébral/épidémiologie , Accident vasculaire cérébral/étiologie , Accident vasculaire cérébral/prévention et contrôle , Fibrillation auriculaire/complications , Fibrillation auriculaire/diagnostic , Fibrillation auriculaire/épidémiologie , Cathétérisme cardiaque/effets indésirables
16.
J Chem Inf Model ; 63(7): 2196-2206, 2023 04 10.
Article de Anglais | MEDLINE | ID: mdl-36977188

RÉSUMÉ

The nation's opioid overdose deaths reached an all-time high in 2021. The majority of deaths are due to synthetic opioids represented by fentanyl. Naloxone, which is a FDA-approved reversal agent, antagonizes opioids through competitive binding at the µ-opioid receptor (mOR). Thus, knowledge of the opioid's residence time is important for assessing the effectiveness of naloxone. Here, we estimated the residence times (τ) of 15 fentanyl and 4 morphine analogs using metadynamics and compared them with the most recent measurement of the opioid kinetic, dissociation, and naloxone inhibitory constants (Mann et al. Clin. Pharmacol. Therapeut. 2022, 120, 1020-1232). Importantly, the microscopic simulations offered a glimpse at the common binding mechanism and molecular determinants of dissociation kinetics for fentanyl analogs. The insights inspired us to develop a machine learning approach to analyze the kinetic impact of fentanyl's substituents based on the interactions with mOR residues. This proof-of-concept approach is general; for example, it may be used to tune ligand residence times in computer-aided drug discovery.


Sujet(s)
Analgésiques morphiniques , Naloxone , Analgésiques morphiniques/pharmacologie , Naloxone/pharmacologie , Naloxone/métabolisme , Fentanyl/métabolisme , Fentanyl/pharmacologie , Morphine/composition chimique , Récepteur mu/métabolisme , Antagonistes narcotiques
17.
Circ Arrhythm Electrophysiol ; 16(5): e011740, 2023 05.
Article de Anglais | MEDLINE | ID: mdl-36960716

RÉSUMÉ

BACKGROUND: Cardiac implantable electronic device (CIED) infection has a high mortality. Previous investigations showed reduced postoperative infections using skin preparation with chlorhexidine, preoperative intravenous antibiotics, and a TYRX-a antibacterial envelope. The additional benefit of antibiotic pocket wash and postoperative antibiotics has not been systematically studied. METHODS: The ENVELOPE trial (A Randomized trial of Stand-Alone Use of the Antimicrobial Envelope in High-Risk Cardiac Device Patients) was a prospective, multicenter, randomized, controlled trial enrolling patients undergoing CIED procedures with ≥2 risk factors for infection. The control arm received standard chlorhexidine skin preparation, intravenous antibiotics, and the TYRX-a antibiotic envelope. The study arm received pocket wash (500 mL antibiotic solution) and postoperative antibiotics for 3 days along with the prophylactic control measures. The primary end point was CIED infection and system removal at 6 months. RESULTS: One thousand ten subjects (505 per arm) were enrolled and randomized. Patients were seen in person for a wound check with digital photo 2 weeks postimplant and at 3 and 6 months. CIED infection rate was low in both groups (1.0% control arm and 1.2% study arm, P=0.74). In the 11 subjects with infection and system removal, the time to study end point was 107±92 days with a PADIT (Prevention of Arrhythmia Device Infection Trial) score of 7.4 and a 64% 1-year mortality. Prior history of CIED infection independently predicted CIED system removal at 6 months in all subjects (odds ratio, 9.77, P=0.004). Of 11 infections requiring system removal, 5 were in the setting of pocket hematoma. CONCLUSIONS: The use of antibiotic pocket irrigation and postoperative oral antibiotics provides no additional benefit to the prophylactic measures of chlorhexidine skin preparation, preoperative intravenous antibiotics, and an antibiotic envelope in reducing CIED infection. Postoperative hematoma is a major risk factor for infection, driven by the use of antiplatelet and anticoagulant medications. The strongest predictor of CIED removal at 6 months, regardless of intervention, was prior CIED infection. REGISTRATION: URL: https://www. CLINICALTRIALS: gov; Unique identifier: NCT02809131.


Sujet(s)
Défibrillateurs implantables , Cardiopathies , Pacemaker , Infections dues aux prothèses , Humains , Défibrillateurs implantables/effets indésirables , Études prospectives , Chlorhexidine , Antibactériens/usage thérapeutique , Cardiopathies/complications , Hématome/étiologie , Infections dues aux prothèses/diagnostic , Infections dues aux prothèses/épidémiologie , Infections dues aux prothèses/prévention et contrôle , Pacemaker/effets indésirables
18.
JACC Clin Electrophysiol ; 9(1): 96-107, 2023 01.
Article de Anglais | MEDLINE | ID: mdl-36697204

RÉSUMÉ

BACKGROUND: Device-related thrombus (DRT) following left atrial appendage occlusion (LAAO) can lead to adverse clinical outcomes. DRT rates and outcomes from randomized trials are limited. OBJECTIVES: This analysis investigated the incidence, predictors, and clinical outcomes of DRT following LAAO in the Amulet IDE (AMPLATZER Amulet LAA Occluder Trial) trial. METHODS: Successful implants occurred in 903 patients with an Amulet occluder (dual occlusive mechanism device) and 885 patients with a Watchman device (single occlusive mechanism device). These patients were then followed through 18 months and DRT was assessed by transesophageal echocardiography. RESULTS: The overall incidence of DRT was 3.9% (n = 70) with 3.4% (n = 30) in dual occlusive mechanism device patients and 4.8% (n = 40) in single occlusive mechanism device patients. Most DRTs (n = 19 of 31) were identified early (≤45 days) on the dual occlusive mechanism device, whereas most of the DRTs (n = 31 of 42) were identified late (>45 days) on the single occlusive mechanism device. Strong predictors of DRT included atrial fibrillation at time of procedure (HR: 2.44; 95% CI: 1.42-4.22; P < 0.01), female sex (HR: 1.65; 95% CI: 1.01-2.71; P = 0.04), and older age (HR: 1.04; 95% CI: 1.01-1.08; P = 0.02). There were no stroke events following DRT in the dual occlusive mechanism device group and 3 stroke events following DRT in the single occlusive mechanism device group. Patients with DRT were at a greater risk for cardiovascular mortality compared with non-DRT patients (8.7% vs 3.9%; HR: 2.33; 95% CI: 1.01-5.39; P = 0.04). CONCLUSIONS: Incidence of DRT following LAAO was low. Early DRTs are seen with the dual occlusive mechanism device and late DRTs are seen with the single occlusive mechanism device. Increased cardiovascular mortality risk in patients with DRT should be further investigated. (AMPLATZER Amulet LAA Occluder Trial; NCT02879448).


Sujet(s)
Auricule de l'atrium , Fibrillation auriculaire , Accident vasculaire cérébral , Thrombose , Femelle , Humains , Fibrillation auriculaire/épidémiologie , Fibrillation auriculaire/chirurgie , Fibrillation auriculaire/complications , Incidence , Accident vasculaire cérébral/épidémiologie , Thrombose/épidémiologie , Thrombose/étiologie
19.
J Cardiovasc Electrophysiol ; 34(1): 135-141, 2023 01.
Article de Anglais | MEDLINE | ID: mdl-36300705

RÉSUMÉ

INTRODUCTION: BNP elevation in patients with AF is observed in the absence of heart failure; however, prior mechanistic studies have not included direct left atrial pressure measurements. This study sought to understand how emptying function of the left atrial appendage (LAA) and LAA dimension contributes to brain-natriuretic peptide elevations (BNP) in atrial fibrillation (AF) accounting for left atrial pressure (LAP). METHODS: 132 patients referredfor left atrial appendage occlusion (LAAO) were prospectively enrolled in this study. BNP levels and LAP were measured just before LAAO. Statistical analysis considered BNP, rhythm at time of procedure, LAP, LAA morphology, LAA size (ostial diameter, depth, volume), LAA emptying velocity, CHADS2-VASc score, body mass index (BMI), left ventricular ejection fraction (LVEF), estimated glomerular filtration rate (eGFR), and obstructive sleep apnea (OSA) diagnosis as covariates. RESULTS: Bivariate statistical analysis demonstrated positive associations with age, LAA ostial diameter, depth, and volume, LAP, AF status at time of measurement, OSA, and CHADS2-VASc score. BNP was negatively associated with LVEF, eGFR, LAA emptying velocity and BMI. With multivariate logistic regression including LAP as covariate, significant relationships between BNP and AF/AFL(OR 1.99 [1.03, 3.85]), LAP (OR 1.13 [1.06, 1.20]), LAA diameter (OR 1.14 [1.03, 1.27]), LAA depth (OR 1.14 [1.07, 1.22]), and LAA emptying velocity (OR 0.97 [0.96,0.99]) were observed; however, no significant associations were seen with LAA morphology or CHADS2-VASc score. CONCLUSIONS: BNP elevations in AF are associated with LAA size and function, but not CHADS2-VASc score or appendage morphology after accounting for changes in LAP.


Sujet(s)
Auricule de l'atrium , Fibrillation auriculaire , Peptide natriurétique cérébral , Humains , Auricule de l'atrium/imagerie diagnostique , Auricule de l'atrium/anatomopathologie , Fibrillation auriculaire/diagnostic , Fibrillation auriculaire/métabolisme , Échocardiographie transoesophagienne , Peptide natriurétique cérébral/sang , Peptide natriurétique cérébral/composition chimique , Syndrome d'apnées obstructives du sommeil/diagnostic , Débit systolique , Fonction ventriculaire gauche