Your browser doesn't support javascript.
loading
Montrer: 20 | 50 | 100
Résultats 1 - 4 de 4
Filtrer
Plus de filtres











Base de données
Gamme d'année
1.
Circ Cardiovasc Interv ; 17(4): e013196, 2024 Apr.
Article de Anglais | MEDLINE | ID: mdl-38626077

RÉSUMÉ

BACKGROUND: Various mitral repair techniques have been described. Though these repair techniques can be highly effective when performed correctly in suitable patients, limited quantitative biomechanical data are available. Validation and thorough biomechanical evaluation of these repair techniques from translational large animal in vivo studies in a standardized, translatable fashion are lacking. We sought to evaluate and validate biomechanical differences among different mitral repair techniques and further optimize repair operations using a large animal mitral valve prolapse model. METHODS: Male Dorset sheep (n=20) had P2 chordae severed to create the mitral valve prolapse model. Fiber Bragg grating force sensors were implanted to measure chordal forces. Ten sheep underwent 3 randomized, paired mitral valve repair operations: neochord repair, nonresectional leaflet remodeling, and triangular resection. The other 10 sheep underwent neochord repair with 2, 4, and 6 neochordae. Data were collected at baseline, mitral valve prolapse, and after each repair. RESULTS: All mitral repair techniques successfully eliminated regurgitation. Compared with mitral valve prolapse (0.54±0.18 N), repair using neochord (0.37±0.20 N; P=0.02) and remodeling techniques (0.30±0.15 N; P=0.001) reduced secondary chordae peak force. Neochord repair further decreased primary chordae peak force (0.21±0.14 N) to baseline levels (0.20±0.17 N; P=0.83), and was associated with lower primary chordae peak force compared with the remodeling (0.34±0.18 N; P=0.02) and triangular resectional techniques (0.36±0.27 N; P=0.03). Specifically, repair using 2 neochordae resulted in higher peak primary chordal forces (0.28±0.21 N) compared with those using 4 (0.22±0.16 N; P=0.02) or 6 neochordae (0.19±0.16 N; P=0.002). No difference in peak primary chordal forces was observed between 4 and 6 neochordae (P=0.05). Peak forces on the neochordae were the lowest using 6 neochordae (0.09±0.11 N) compared with those of 4 neochordae (0.15±0.14 N; P=0.01) and 2 neochordae (0.29±0.18 N; P=0.001). CONCLUSIONS: Significant biomechanical differences were observed underlying different mitral repair techniques in a translational large animal model. Neochord repair was associated with the lowest primary chordae peak force compared to the remodeling and triangular resectional techniques. Additionally, neochord repair using at least 4 neochordae was associated with lower chordal forces on the primary chordae and the neochordae. This study provided key insights about mitral valve repair optimization and may further improve repair durability.


Sujet(s)
Implantation de valve prothétique cardiaque , Insuffisance mitrale , Prolapsus de la valve mitrale , Humains , Mâle , Animaux , Ovis , Insuffisance mitrale/imagerie diagnostique , Insuffisance mitrale/chirurgie , Prolapsus de la valve mitrale/imagerie diagnostique , Prolapsus de la valve mitrale/chirurgie , Valve atrioventriculaire gauche/imagerie diagnostique , Valve atrioventriculaire gauche/chirurgie , Implantation de valve prothétique cardiaque/méthodes , Cordages tendineux/chirurgie , Résultat thérapeutique
2.
Eur J Cardiothorac Surg ; 65(3)2024 Mar 01.
Article de Anglais | MEDLINE | ID: mdl-38258541

RÉSUMÉ

OBJECTIVES: Artificial neochordae implantation is commonly used for mitral valve (MV) repair. However, neochordae length estimation can be difficult to perform. The objective was to assess the impact of neochordae length changes on MV haemodynamics and neochordal forces. METHODS: Porcine MVs (n = 6) were implanted in an ex vivo left heart simulator. MV prolapse (MVP) was generated by excising at least 2 native primary chordae supporting the P2 segments from each papillary muscle. Two neochordae anchored on each papillary muscle were placed with 1 tied to the native chord length (exact length) and the other tied with variable lengths from 2× to 0.5× of the native length (variable length). Haemodynamics, neochordal forces and echocardiography data were collected. RESULTS: Neochord implantation repair successfully eliminated mitral regurgitation with repaired regurgitant fractions of approximately 4% regardless of neochord length (P < 0.01). Leaflet coaptation height also significantly improved to a minimum height of 1.3 cm compared with that of MVP (0.9 ± 0.4 cm, P < 0.05). Peak and average forces on exact length neochordae increased as variable length neochordae lengths increased. Peak and average forces on the variable length neochordae increased with shortened lengths. Overall, chordal forces appeared to vary more drastically in variable length neochordae compared with exact length neochordae. CONCLUSIONS: MV regurgitation was eliminated with neochordal repair, regardless of the neochord length. However, chordal forces varied significantly with different neochord lengths, with a preferentially greater impact on the variable length neochord. Further validation studies may be performed before translating to clinical practices.


Sujet(s)
Insuffisance mitrale , Prolapsus de la valve mitrale , Animaux , Suidae , Valve atrioventriculaire gauche/chirurgie , Cordages tendineux/chirurgie , Conception de prothèse , Insuffisance mitrale/chirurgie , Prolapsus de la valve mitrale/chirurgie
3.
Bioengineering (Basel) ; 9(12)2022 Dec 15.
Article de Anglais | MEDLINE | ID: mdl-36551013

RÉSUMÉ

Extrusion-based three-dimensional (3D) bioprinting is an emerging technology that allows for rapid bio-fabrication of scaffolds with live cells. Alginate is a soft biomaterial that has been studied extensively as a bio-ink to support cell growth in 3D constructs. However, native alginate is a bio-inert material that requires modifications to allow for cell adhesion and cell growth. Cells grown in modified alginates with the RGD (arginine-glycine-aspartate) motif, a naturally existing tripeptide sequence that is crucial to cell adhesion and proliferation, demonstrate enhanced cell adhesion, spreading, and differentiation. Recently, the bioprinting technique using freeform reversible embedding of suspended hydrogels (FRESH) has revolutionized 3D bioprinting, enabling the use of soft bio-inks that would otherwise collapse in air. However, the printability of RGD-modified alginates using the FRESH technique has not been evaluated. The associated physical properties and bioactivity of 3D bio-printed alginates after RGD modification remains unclear. In this study, we characterized the physical properties, printability, and cellular proliferation of native and RGD-modified alginate after extrusion-based 3D bioprinting in FRESH. We demonstrated tunable physical properties of native and RGD-modified alginates after FRESH 3D bioprinting. Sodium alginate with RGD modification, especially at a high concentration, was associated with greatly improved cell viability and integrin clustering, which further enhanced cell proliferation.

4.
Sci Rep ; 12(1): 10028, 2022 06 15.
Article de Anglais | MEDLINE | ID: mdl-35705660

RÉSUMÉ

Peripheral artery disease and the associated ischemic wounds are substantial causes of global morbidity and mortality, affecting over 200 million people worldwide. Although advancements have been made in preventive, pharmacologic, and surgical strategies to treat this disease, ischemic wounds, a consequence of end-stage peripheral artery disease, remain a significant clinical and economic challenge. Synechococcus elongatus is a cyanobacterium that grows photoautotrophically and converts carbon dioxide and water into oxygen. We present a novel topical biologic gel containing S. elongatus that provides oxygen via photosynthesis to augment wound healing by rescuing ischemic tissues caused by peripheral artery disease. By using light rather than blood as a source of energy, our novel topical therapy significantly accelerated wound healing in two rodent ischemic wound models. This novel topical gel can be directly translated to clinical practice by using a localized, portable light source without interfering with patients' daily activities, demonstrating potential to generate a paradigm shift in treating ischemic wounds from peripheral artery disease. Its novelty, low production cost, and ease of clinical translatability can potentially impact the clinical care for millions of patients suffering from peripheral arterial disease.


Sujet(s)
Produits biologiques , Maladie artérielle périphérique , Gels , Humains , Ischémie , Oxygène , Maladie artérielle périphérique/thérapie , Photosynthèse , Cicatrisation de plaie
SÉLECTION CITATIONS
DÉTAIL DE RECHERCHE