Your browser doesn't support javascript.
loading
Montrer: 20 | 50 | 100
Résultats 1 - 7 de 7
Filtrer
Plus de filtres










Base de données
Gamme d'année
1.
Rev Sci Instrum ; 94(12)2023 Dec 01.
Article de Anglais | MEDLINE | ID: mdl-38109469

RÉSUMÉ

An E-band (60-90 GHz) multi-channel Doppler backscattering (DBS) system with X-mode polarization has been installed on the Experimental Advanced Superconducting Tokamak (EAST), which can measure the turbulence at five different radial locations simultaneously. This system can launch 31 fixed microwave frequencies in the range of 60-90 GHz with a 1 GHz interval into the plasma, and five probing signals are selected by employing a reference signal and multiple filters. During experiments, the frequency of the reference signal is tunable in the E-band, and the selected probing signals can be changed as needed without any other adjustments, which can be performed in one shot or between shots. Furthermore, the incident angle can be adjusted from -10° to 20°, and the wavenumber range is 4-25 cm-1 with a wavenumber resolution of Δk/k ≤ 0.35. Ray tracing simulations are employed to calculate the scattering locations and the perpendicular wavenumber. In this article, the hardware design, ray tracing, and initial results obtained from the EAST plasma will be presented.

2.
Rev Sci Instrum ; 92(4): 043511, 2021 Apr 01.
Article de Anglais | MEDLINE | ID: mdl-34243396

RÉSUMÉ

The cross-polarization scattering (CPS) system for magnetic fluctuation measurements in the Experimental Advanced Superconducting Tokamak (EAST) has been designed and installed. Different from the Doppler reflectometer (DR) system, the CPS system detects the perpendicular polarization of the electromagnetic wave induced by magnetic fluctuations B̃. The CPS system in the EAST has been developed from the existing Doppler reflectometer system, and they are integrated together for simultaneous measurement of magnetic and density fluctuations. Ray-tracing simulations are used to calculate the scattering locations and the wavenumber coverage of the magnetic fluctuation for CPS. In the experiments, the CPS and DR system data were different in Doppler shift, amplitude, and spectrum broadening. In this article, the hardware design, the ray tracing, and the preliminary results of the system in the EAST are presented.

3.
Eur Rev Med Pharmacol Sci ; 24(8): 4585-4596, 2020 04.
Article de Anglais | MEDLINE | ID: mdl-32373999

RÉSUMÉ

In December 2019, an outbreak of coronavirus disease 2019 (COVID-19) caused by severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) was reported in Wuhan, China, and it subsequently spread in many countries around the world. Many efforts have been applied to control and prevent the spread of COVID-19, and many scientific studies have been conducted in a short period of time. Here we present an overview of the viral structure, pathogenesis, diagnosis, and clinical features of COVID-19 based on the current state of knowledge, and we compare its clinical characteristics with SARS and Middle East Respiratory Syndrome (MERS). Current researches on potentially effective treatment alternatives are discussed. We hope this review can help medical workers and researchers around the world contain the current COVID-19 pandemic.


Sujet(s)
Betacoronavirus/pathogénicité , Infections à coronavirus/thérapie , Infections à coronavirus/virologie , Pneumopathie virale/thérapie , Pneumopathie virale/virologie , Angiotensin-converting enzyme 2 , Antiviraux/usage thérapeutique , COVID-19 , Infections à coronavirus/diagnostic , Infections à coronavirus/anatomopathologie , Humains , Immunothérapie , Médecine traditionnelle chinoise , Coronavirus du syndrome respiratoire du Moyen-Orient , Pandémies , Peptidyl-Dipeptidase A/composition chimique , Pneumopathie virale/diagnostic , Pneumopathie virale/anatomopathologie , ARN viral , SARS-CoV-2 , Syndrome respiratoire aigu sévère , Protéines virales/composition chimique
4.
Article de Chinois | MEDLINE | ID: mdl-31434383

RÉSUMÉ

Most of the common dizziness/vertigo diseases in otology clinic are peripheral vertigo diseases, and while about 20% -30% of all vertigo diseases are caused by central nervous system diseases. Pseudo vestibular neuritis, acute ischemic stroke with audiovestibular loss, and central paroxysmal positional vertigo are the three types of central "malignant vertigo" diseases which are most easily misdiagnosed by otologists. This article described the clinical characteristics and bedside physical performance of these three diseases, and summarized the differential diagnosis points for clinical reference.


Sujet(s)
Dépistage de masse/méthodes , Vertige/diagnostic , Vertige/étiologie , Diagnostic différentiel , Humains , Recueil de l'anamnèse , Examen physique
5.
Article de Chinois | MEDLINE | ID: mdl-31163518

RÉSUMÉ

Objective:To investigate the clinical features of LC-BPPV with direction-fixed horizontal nystagmus in the primary Roll test. Method:Nine patients of LC-BPPV with bilateral direction-fixed horizontal nystagmus in the first Roll test were treated by repositioning maneuvers after judging the affected side and the prognosis was observed. Result:The affected side of eight patients was the side of the apogeotropic nystagmus. Barbecue or Gufoni maneuvers was effective for reposition. The other one had no conversion of nystagmus and could not judge the affected side. Conclusion:The nystagmus performance of patients with LC-BPPV is complicated. It is necessary to carefully analyze the nystagmus performance of each position. Combining with bow and lean test, lying down test and null plane, the position of the otolith is inferred. Comprehensive use of the Barbecue or Gufoni maneuvers, forced side lying on the affected side, mastoid sniper, shaking head method is effective to complete the reposition treatment.


Sujet(s)
Vertige positionnel paroxystique bénin , Nystagmus pathologique , Vertige positionnel paroxystique bénin/complications , Vertige positionnel paroxystique bénin/diagnostic , Tête , Humains , Nystagmus pathologique/étiologie , Membrane des statoconies , Positionnement du patient , Canaux semicirculaires osseux
6.
Rev Sci Instrum ; 90(2): 024704, 2019 Feb.
Article de Anglais | MEDLINE | ID: mdl-30831725

RÉSUMÉ

A 5-channel Doppler backscattering system has been designed and installed in the Experimental Advanced Superconducting Tokamak (EAST). Through an I/Q-type double sideband modulator and a frequency multiplier, an array of finely spaced (Δf = 400 MHz) frequencies that span 1.6 GHz has been created. The center of the array bandwidth is tunable within the range of 75-97.8 GHz, which covers most of the W band (75-110 GHz). The incident angle can be adjusted from -4° to 12°, and the wavenumber range is 4-15 cm-1 with a wavenumber resolution of Δk/k ≤ 0.35. Ray tracing is used to calculate the scattering location and the scattering wavenumber. This article details the hardware design, the ray tracing, and the preliminary experimental results from EAST plasmas.

SÉLECTION CITATIONS
DÉTAIL DE RECHERCHE