Your browser doesn't support javascript.
loading
Montrer: 20 | 50 | 100
Résultats 1 - 1 de 1
Filtrer
Plus de filtres











Base de données
Gamme d'année
1.
Circ Cardiovasc Interv ; 17(6): e013842, 2024 Jun.
Article de Anglais | MEDLINE | ID: mdl-38708595

RÉSUMÉ

BACKGROUND: An increasing number of interventional procedures require large-sheath technology (>12F) with a favorable outcome with endovascular rather than open surgical access. However, vascular complications are a limitation for the management of these patients. This trial aimed to determine the effectiveness and safety of the Cross-Seal suture-mediated vascular closure device in obtaining hemostasis at the target limb access site following interventional procedures using 8F to 18F procedural sheaths. METHODS: The Cross-Seal IDE trial (Investigational Device Exemption) was a prospective, single-arm, multicenter study in subjects undergoing percutaneous endovascular procedures utilizing 8F to 18F ID procedural sheaths. The primary efficacy end point was time to hemostasis at the target limb access site. The primary safety end point was freedom from major complications of the target limb access site within 30 days post procedure. RESULTS: A total of 147 subjects were enrolled between August 9, 2019, and March 12, 2020. Transcatheter aortic valve replacement was performed in 53.7% (79/147) and percutaneous endovascular abdominal/thoracic aortic aneurysm repair in 46.3% (68/147) of subjects. The mean sheath ID was 15.5±1.8 mm. The primary effectiveness end point of time to hemostasis was 0.4±1.4 minutes. An adjunctive intervention was required in 9.2% (13/142) of subjects, of which 2.1% (3/142) were surgical and 5.6% (8/142) endovascular. Technical success was achieved in 92.3% (131/142) of subjects. Freedom from major complications of the target limb access site was 94.3% (83/88). CONCLUSIONS: In selected patients undergoing percutaneous endovascular procedures utilizing 8F to 18F ID procedural sheath, Cross-Seal suture-mediated vascular closure device achieved favorable effectiveness and safety in the closure of the large-bore arteriotomy. REGISTRATION: URL: https://www.clinicaltrials.gov; Unique identifier: NCT03756558.


Sujet(s)
Procédures endovasculaires , Techniques d'hémostase , Techniques de suture , Dispositifs de fermeture vasculaire , Humains , Études prospectives , Mâle , Femelle , Sujet âgé , Techniques d'hémostase/instrumentation , Techniques d'hémostase/effets indésirables , Résultat thérapeutique , Facteurs temps , Techniques de suture/effets indésirables , Techniques de suture/instrumentation , Procédures endovasculaires/effets indésirables , Procédures endovasculaires/instrumentation , Sujet âgé de 80 ans ou plus , Conception d'appareillage , Ponctions , Cathétérisme périphérique/effets indésirables , Cathétérisme périphérique/instrumentation , Hémorragie/prévention et contrôle , Hémorragie/étiologie , Adulte d'âge moyen , Remplacement valvulaire aortique par cathéter/effets indésirables , Remplacement valvulaire aortique par cathéter/instrumentation , Facteurs de risque , Anévrysme de l'aorte abdominale/chirurgie , Anévrysme de l'aorte abdominale/imagerie diagnostique , Implantation de prothèses vasculaires/effets indésirables , Implantation de prothèses vasculaires/instrumentation , Anévrysme de l'aorte thoracique/chirurgie , Anévrysme de l'aorte thoracique/imagerie diagnostique
SÉLECTION CITATIONS
DÉTAIL DE RECHERCHE