Your browser doesn't support javascript.
loading
Montrer: 20 | 50 | 100
Résultats 1 - 2 de 2
Filtrer
Plus de filtres











Base de données
Gamme d'année
1.
Technol Cancer Res Treat ; 10(6): 585-90, 2011 Dec.
Article de Anglais | MEDLINE | ID: mdl-22066598

RÉSUMÉ

The purpose of this study was to evaluate rectum motion during 3-Dimensional conformal radiation therapy (3D-CRT) in prostate cancer patients, to derive a planning volume at risk (PRV) and to correlate the PRV dose-volume histograms (DVH) with treatment complications.This study was conducted in two phases. Initially, the PRV was defined prospectively in 50 consecutive prostate cancer patients (Group 1) who received a radical course of 3-D CRT. Then, the obtained PRV was used in the radiotherapy planning of these same 50 patients plus another 59 prostate cancer patients (Group 2) previously treated between 2004 and 2008. All these patients' data, including the rectum and PRV DVHs, were correlated to acute and late complications, according to the Common Toxicity Criteria (CTC) v4.0.The largest displacement occurred in the anterior axis. Long-term gastrointestinal (GI) complications grade ≥ 2 were seen in 9.2% of the cases. Factors that influenced acute GI reactions were: doses at 25% (p 5 0.011) and 40% (p 5 0.005) of the rectum volume and at 40% of the PRV (p 5 0.012). The dose at 25% of the rectum volume (p 5 0.033) and acute complications ≥ grade 2 (p 5 0.018) were prognostic factors for long-term complications. The PRV DVH did not correlate with late toxicity. The rectum showed a significant inter-fraction motion during 3D-CRT for prostate cancer. PRV dose correlated with acute gastrointestinal complications and may be a useful tool to predict and reduce their occurrence.


Sujet(s)
Maladies gastro-intestinales/étiologie , Imagerie tridimensionnelle , Tumeurs de la prostate/anatomopathologie , Tumeurs de la prostate/radiothérapie , Lésions radiques/étiologie , Planification de radiothérapie assistée par ordinateur , Radiothérapie conformationnelle/effets indésirables , Sujet âgé , Sujet âgé de 80 ans ou plus , Humains , Mâle , Adulte d'âge moyen , Pronostic , Tumeurs de la prostate/complications
2.
Phys Med Biol ; 44(3): N31-8, 1999 Mar.
Article de Anglais | MEDLINE | ID: mdl-10211813

RÉSUMÉ

The lack of well established dosimetry protocols for HDR sources is a point of great concern regarding the uniformity of procedures within a particular country and worldwide. The main objective of this paper is to report the results from ten institutions of an intercomparison of calibration procedures for 192Ir HDR sources currently in use in Brazil. The treatment irradiator of one institution was calibrated by a reference system and used by all participants with their own measuring electrometers and ionization chambers under the same experimental conditions. Two methods were used: the calibration jig and the well-type ionization chamber. Each participant was allowed to use their own method and formalism. The results of this exercise were very positive since this was the first time in Brazil that a group of users gathered to share their experience and openly discuss the physical concepts behind the calibration procedures. The results were all within +/-3.0%, except one case where -4.6% was observed and later identified as a problem with the Nk value for x-rays. Though the magnitude of the deviations found was generally acceptable considering the diversity of formalisms currently in use, a proposal is now being prepared to be adopted as a national protocol. The identification of the institutions was left out for the sake of confidentiality.


Sujet(s)
Radio-isotopes de l'iridium/analyse , Radiométrie , Curiethérapie , Brésil , Calibrage , Rayons gamma
SÉLECTION CITATIONS
DÉTAIL DE RECHERCHE