Your browser doesn't support javascript.
loading
Montrer: 20 | 50 | 100
Résultats 1 - 1 de 1
Filtrer
Plus de filtres










Base de données
Gamme d'année
1.
BMC Ecol Evol ; 24(1): 4, 2024 01 05.
Article de Anglais | MEDLINE | ID: mdl-38178008

RÉSUMÉ

BACKGROUND: Batrachochytrium dendrobatidis (Bd) and Batrachochytrium salamandrivorans (Bsal) are two pathogenic fungi that are a significant threat to amphibian communities worldwide. European populations are strongly impacted and the monitoring of the presence and spread of these pathogens is crucial for efficient decision-making in conservation management. RESULTS: Here we proposed an environmental DNA (eDNA) monitoring of these two pathogenic agents through droplet digital PCR (ddPCR) based on water samples from 24 ponds in Luxembourg. In addition, amphibians were swabbed in eight of the targeted ponds in order to compare the two approaches at site-level detection. This study allowed the development of a new method taking below-Limit of Detection (LOD) results into account thanks to the statistical comparison of the frequencies of false positives in no template controls (NTC) and below-LOD results in technical replicates. In the eDNA-based approach, the use of this method led to an increase in Bd and Bsal detection of 28 and 50% respectively. In swabbing, this resulted in 8% more positive results for Bd. In some samples, the use of technical replicates allowed to recover above-LOD signals and increase Bd detection by 35 and 33% respectively for eDNA and swabbing, and Bsal detection by 25% for eDNA. CONCLUSIONS: These results confirmed the usefulness of technical replicates to overcome high levels of stochasticity in very low concentration samples even for a highly sensitive technique such as ddPCR. In addition, it showed that below-LOD signals could be consistently recovered and the corresponding amplification events assigned either to positive or negative detection via the method developed here. This methodology might be particularly worth pursuing in pathogenic agents' detection as false negatives could have important adverse consequences. In total, 15 ponds were found positive for Bd and four for Bsal. This study reports the first record of Bsal in Luxembourg.


Sujet(s)
Chytridiomycota , ADN environnemental , Mycoses , Animaux , Batrachochytrium (genre)/génétique , Mycoses/diagnostic , Mycoses/microbiologie , Chytridiomycota/génétique , Luxembourg , Limite de détection , Étangs , Amphibiens/génétique , Amphibiens/microbiologie , Réaction de polymérisation en chaîne/médecine vétérinaire
SÉLECTION CITATIONS
DÉTAIL DE RECHERCHE
...