Vox Sang ; 2024 May 16.
Article de Anglais | MEDLINE | ID: mdl-38754952

RÉSUMÉ

BACKGROUND AND OBJECTIVES: Blood safety measures used by blood establishments to increase blood component safety can be validated using Transfusion-Relevant Bacterial Reference Strains (TRBRS). Ultra-cold storage conditions and manual preparation of the current TRBRS may restrict their practical use. To address this issue, the ISBT Transfusion-Transmitted Infectious Diseases Working Party's Bacterial Subgroup organized an international study to validate TRBRS in a user-friendly, lyophilised format. MATERIALS AND METHODS: Two bacterial strains Klebsiella pneumoniae PEI-B-P-08 and Staphylococcus aureus PEI-B-P-63 were manufactured as lyophilised material. The lyophilised bacteria were distributed to 11 different labs worldwide to assess the robustness for enumeration, identification and determination of growth kinetics in platelet concentrates (PCs). RESULTS: Production of lyophilised TRBRS had no impact on the growth properties compared with the traditional format. The new format allows a direct low-quantity spiking of approximately 30 bacteria in PCs for transfusion-relevant experiments. In addition, the lyophilised bacteria exhibit long-term stability across a broad temperature range and can even be directly rehydrated in PCs without losing viability. Interlaboratory comparative study demonstrated the robustness of the new format as 100% of spiked PC exhibited growth. CONCLUSION: Lyophilised TRBRS provide a user-friendly material for transfusion-related studies. TRBRS in the new format have improved features that may lead to a more frequent use in the quality control of transfusion-related safety measures in the future.

2.
Vox Sang ; 2024 May 03.
Article de Anglais | MEDLINE | ID: mdl-38699884

RÉSUMÉ

BACKGROUND AND OBJECTIVES: West Nile virus (WNV) and Usutu virus (USUV) are mosquito-borne flaviviruses (Flaviviridae) that originated in Africa, have expanded their geographical range during the last decades and caused documented infections in Europe in the last years. Acute WNV and USUV infections have been detected in asymptomatic blood donors by nucleic acid testing. Thus, inactivation of both viral pathogens before blood transfusion is necessary to ensure blood product safety. This study aimed to investigate the efficacy of the THERAFLEX UV-Platelets system to inactivate WNV and USUV in platelet concentrates (PCs). MATERIALS AND METHODS: Plasma-reduced PCs were spiked with the virus suspension. Spiked PC samples were taken after spiking (load and hold sample) and after UVC illumination on the Macotronic UV illumination machine with different light doses (0.05, 0.1, 0.15 and 0.2 (standard) J/cm2). Virus loads of WNV and USUV before and after illumination were measured by titration. RESULTS: Infectivity assays showed that UVC illumination inactivated WNV and USUV in a dose-dependent manner. At a UVC dose of 0.2 J/cm2, the WNV titre was reduced by a log10 factor of 3.59 ± 0.43 for NY99 (lineage 1) and 4.40 ± 0.29 for strain ED-I-33/18 (lineage 2). USUV titres were reduced at the same UVC dose by a log10 factor of 5.20 ± 0.70. CONCLUSIONS: Our results demonstrate that the THERAFLEX UV-Platelets procedure is an effective technology to inactivate WNV and USUV in contaminated PCs.

3.
Transfus Med Hemother ; 51(2): 76-83, 2024 Apr.
Article de Anglais | MEDLINE | ID: mdl-38584696

RÉSUMÉ

Introduction: Bacterial contamination of blood products presumably occurs mainly during blood collection, starting from low initial concentrations of 10-100 colony-forming units (CFUs) per bag. As little is known about bacterial growth behavior and distribution in stored whole blood (WB) and WB-derived blood products, this study aims to provide data on this subject. Methods: WB units were inoculated with transfusion-relevant bacterial species (Acinetobacter baumannii, Bacillus cereus, Escherichia coli, Klebsiella pneumoniae, Listeria monocytogenes, Pseudomonas fluorescens, Serratia marcescens, Staphylococcus aureus, Staphylococcus epidermidis, Streptococcus dysgalactiae, Streptococcus pyogenes, Yersinia enterocolitica; n = 12 for each species), stored for 22-24 h at room temperature, and then centrifuged for separation into plasma, red blood cells (RBCs), and buffy coats (BCs). The latter were pooled with 3 random donor BCs and one unit of PAS-E each to yield plasma-reduced platelet concentrates (PCs). Samples for bacterial colony counting were collected after WB storage and immediately after blood component production. Sterility testing in PCs (n = 12 for each species) was performed by bacterial culture after 7 days of storage. Results: Bacterial growth in WB varied remarkably between donations and species. Streptococcus species produced the highest titers in WB, whereas Staphylococcus aureus, Staphylococcus epidermidis, Escherichia coli, and Pseudomonas fluorescens did not multiply. Centrifugation resulted in preferential accumulation of bacteria in BCs, with titers of up to 3.5 × 103 CFU/mL in BCs and up to ≤0.9 × 103 CFU/mL in BC-derived PCs. Overall, 72/144 PCs (50%) tested positive for bacteria after storage. Sterility test results were species-dependent, ranging from 12 of 12 PCs tested positive for Streptococcus pyogenes to 1 of 12 PCs positive for Escherichia coli. Bacterial contamination of RBC and plasma units was much less common and was associated with higher initial bacterial counts in the parent WB units. Conclusions: Bacterial growth in WB is species-dependent and varies greatly between donations. Preferential accumulation of bacteria in BCs during manufacturing is a critical determinant of the contamination risk of BC-derived pooled PCs.

4.
Vox Sang ; 2024 Apr 17.
Article de Anglais | MEDLINE | ID: mdl-38631895

RÉSUMÉ

BACKGROUND AND OBJECTIVES: Platelet concentrates (PC) are stored at 20-24°C to maintain platelet functionality, which may promote growth of contaminant bacteria. Alternatively, cold storage of PC limits bacterial growth; however, data related to proliferation of psychotrophic species in cold-stored PC (CSP) are scarce, which is addressed in this study. MATERIALS AND METHODS: Eight laboratories participated in this study with a pool/split approach. Two split PC units were spiked with ~25 colony forming units (CFU)/PC of Staphylococcus aureus, Klebsiella pneumoniae, Serratia liquefaciens, Pseudomonas fluorescens and Listeria monocytogenes. One unit was stored under agitation at 20-24°C/7 days while the second was stored at 1-6°C/no agitation for 21 days. PC were sampled periodically to determine bacterial loads. Five laboratories repeated the study with PC inoculated with lyophilized inocula (~30 CFU/mL) of S. aureus and K. pneumoniae. RESULTS: All species proliferated in PC stored at 20-24°C, reaching concentrations of ≤109 CFU/mL by day 7. Psychrotrophic P. fluorescens and S. liquefaciens proliferated in CSP to ~106 CFU/mL and ~105 CFU/mL on days 10 and 17 of storage, respectively, followed by L. monocytogenes, which reached ~102 CFU/mL on day 21. S. aureus and K. pneumoniae did not grow in CSP. CONCLUSION: Psychrotrophic bacteria, which are relatively rare contaminants in PC, proliferated in CSP, with P. fluorescens reaching clinically significant levels (≥105 CFU/mL) before day 14 of storage. Cold storage reduces bacterial risk of PC to levels comparable with RBC units. Safety of CSP could be further improved by implementing bacterial detection systems or pathogen reduction technologies if storage is beyond 10 days.

5.
Transfusion ; 63(2): 288-293, 2023 02.
Article de Anglais | MEDLINE | ID: mdl-36573801

RÉSUMÉ

BACKGROUND: Severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) is unlikely to be a major transfusion-transmitted pathogen; however, convalescent plasma is a treatment option used in some regions. The risk of transfusion-transmitted infections can be minimized by implementing Pathogen Inactivation (PI), such as THERAFLEX MB-plasma and THERAFLEX UV-Platelets systems. Here we examined the capability of these PI systems to inactivate SARS-CoV-2. STUDY DESIGN AND METHODS: SARS-CoV-2 spiked plasma units were treated using the THERAFLEX MB-Plasma system in the presence of methylene blue (~0.8 µmol/L; visible light doses: 20, 40, 60, and 120 [standard] J/cm2 ). SARS-CoV-2 spiked platelet concentrates (PCs) were treated using the THERAFLEX UV-platelets system (UVC doses: 0.05, 0.10, 0.15, and 0.20 [standard] J/cm2 ). Samples were taken prior to the first and after each illumination dose, and viral infectivity was assessed using an immunoplaque assay. RESULTS: Treatment of spiked plasma with the THERAFLEX MB-Plasma system resulted in an average ≥5.03 log10 reduction in SARS-CoV-2 infectivity at one third (40 J/cm2 ) of the standard visible light dose. For the platelet concentrates (PCs), treatment with the THERAFLEX UV-Platelets system resulted in an average ≥5.18 log10 reduction in SARS-CoV-2 infectivity at the standard UVC dose (0.2 J/cm2 ). CONCLUSIONS: SARS-CoV-2 infectivity was reduced in plasma and platelets following treatment with the THERAFLEX MB-Plasma and THERAFLEX UV-Platelets systems, to the limit of detection, respectively. These PI technologies could therefore be an effective option to reduce the risk of transfusion-transmitted emerging pathogens.


Sujet(s)
COVID-19 , Bleu de méthylène , Humains , Bleu de méthylène/pharmacologie , SARS-CoV-2 , COVID-19/thérapie , Sérothérapie COVID-19 , Lumière , Rayons ultraviolets , Plaquettes , Inactivation virale
6.
Transfusion ; 62(11): 2314-2323, 2022 11.
Article de Anglais | MEDLINE | ID: mdl-36087025

RÉSUMÉ

BACKGROUND: Pathogen inactivation (PI) technologies for platelet concentrates and plasma are steadily becoming more established, but new PI treatment options for red blood cells (RBCs), the most commonly used blood component, still need to be developed. We present a novel approach to inactivating pathogens in RBC units employing ultraviolet C (UVC) light. METHODS: Whole blood-derived leukoreduced RBCs suspended in PAGGS-C, a third generation additive solution, served as test samples, and RBCs in PAGGS-C or SAG-M as controls. Vigorous agitation and hematocrit reduction by diluting the RBCs with additional additive solution during illumination ensured that UVC light penetrated and inactivated the nine bacteria and eight virus species tested. Bacterial and viral infectivity assays and in vitro analyses were performed to evaluate the system's PI capacity and to measure the RBC quality, metabolic, functional, and blood group serological parameters of UVC-treated versus untreated RBCs during 36-day storage. RESULTS: UVC treatment of RBCs in the PAGGS-C additive solution did not alter RBC antigen expression, but significantly influenced some in vitro parameters. Compared to controls, hemolysis was higher in UVC-treated RBC units, but was still below 0.8% at 36 days of storage. Extracellular potassium increased early after PI treatment and reached ≤70 mmol/L by the end of storage. UVC-treated RBC units had higher glucose and 2,3-diphosphoglycerate levels than controls. CONCLUSION: As UVC irradiation efficiently reduces the infectivity of relevant bacteria and viruses while maintaining the quality of RBCs, the proposed method offers a new approach for PI of RBC concentrates.


Sujet(s)
Conservation de sang , Érythrocytes , Humains , Conservation de sang/méthodes , Érythrocytes/métabolisme , Hémolyse , Rayons ultraviolets , Numération des érythrocytes
7.
Transfusion ; 62(11): 2200-2204, 2022 11.
Article de Anglais | MEDLINE | ID: mdl-36125237

RÉSUMÉ

BACKGROUND AND OBJECTIVES: Photodynamic treatment with methylene blue (MB) and visible light is a well-established pathogen inactivation system for human plasma. This technique is routinely used in different countries. MB/light treatment was shown to inactivate several transfusion-transmittable viruses, but its efficiency for the inactivation of the quasi-enveloped hepatitis E virus (HEV) has not yet been investigated. MATERIALS AND METHODS: Plasma units were spiked with cell culture-derived HEV and treated with the THERAFLEX MB-Plasma system using various light doses (30, 60, 90, and 120 J/cm2 ). HEV titers in pre- and post-treatment samples were determined by virus titration and a large-volume plating assay to improve the detection limit of the virus assay. RESULTS: THERAFLEX MB-Plasma efficiently inactivated HEV in human plasma. Even the lowest light dose of 30 J/cm2 inactivated HEV down to the limit of detection, with a mean log reduction factor of greater than 2.4 for the total process. CONCLUSION: Our study demonstrates that the THERAFLEX MB-Plasma system effectively inactivates HEV in human plasma.


Sujet(s)
Virus de l'hépatite E , Bleu de méthylène , Humains , Bleu de méthylène/pharmacologie , Inactivation virale , Rayons ultraviolets , Lumière
8.
Vox Sang ; 117(5): 671-677, 2022 May.
Article de Anglais | MEDLINE | ID: mdl-35023205

RÉSUMÉ

BACKGROUND AND OBJECTIVES: In many countries, whole blood (WB) donations with collection times between 12 and 15 min are not allowed to be used for platelet concentrates (PC). Since the development of guidelines, many process-related changes have been introduced. We aimed to determine the effect of WB with long collection times on PC quality. MATERIALS AND METHODS: Five participating centres tested buffy coat (BC)-derived PC in platelet additive solution type E prepared from only WB collections lasting <12 min (control) versus similar PC including one BC from a collection lasting >12 min (study group, n = 8). One centre produced platelet-rich plasma (PRP)-derived PC from single donations (<10 or >12 min). All PC were stored at 22 ± 2°C and sampled on Days 1, 6 and 8 post-collection for in vitro quality determination. RESULTS: Average collection time was significantly longer in the study group compared to controls (8.9 ± 2.6 vs. 7.3 ± 1.3 min, p < 0.001). There were no differences in volume, platelet concentration, basal CD62P expression, soluble-CD62P and CCL5 levels, or nucleotide content between the groups. Stimulation with TRAP-6 resulted in comparable levels of cell surface CD62P. On Day 8, all PC fulfilled requirements for pH. The findings from single PRP-derived PC centre were similar. CONCLUSION: PC with one BC and single PRP derived from collections lasting >12 min had equivalent in vitro quality to controls during storage. This study provides evidence that 12-15 min donations should not be excluded for PC preparation and justifies to readdress the guidelines to <15 min instead of <12 min of collection in line with current practice in some countries.


Sujet(s)
Donneurs de sang , Plasma riche en plaquettes , Plaquettes , Conservation de sang , Humains
9.
Transfusion ; 60(11): 2655-2660, 2020 11.
Article de Anglais | MEDLINE | ID: mdl-32830340

RÉSUMÉ

Japanese encephalitis virus (JEV) is endemic to tropical areas in Asia and the Western Pacific. It can cause fatal encephalitis, although most infected individuals are asymptomatic. JEV is mainly transmitted to humans through the bite of an infected mosquito, but can also be transmitted through blood transfusion. To manage the potential risk of transfusion transmission, pathogen inactivation (PI) technologies, such as THERAFLEX MB-Plasma and THERAFLEX UV-Platelets systems, have been developed. We examined the efficacy of these two PI systems to inactivate JEV. STUDY DESIGN AND METHODS: Japanese encephalitis virus-spiked plasma units were treated using the THERAFLEX MB-Plasma system (visible light doses, 20, 40, 60, and 120 [standard] J/cm2) in the presence of methylene blue at approximately 0.8 µmol/L and spiked platelet concentrates (PCs) were treated using the THERAFLEX UV-Platelets system (UVC doses, 0.05, 0.10, 0.15, and 0.20 [standard] J/cm2). Samples were taken before the first and after each illumination dose and tested for infectivity using an immunoplaque assay. RESULTS: Treatment of plasma with the THERAFLEX MB-Plasma system resulted in an average of 6.59 log reduction in JEV infectivity at one-sixth of the standard visible light dose (20 J/cm2). For PCs, treatment with the THERAFLEX UV-Platelet system resulted in an average of 7.02 log reduction in JEV infectivity at the standard UVC dose (0.20 J/cm2). CONCLUSIONS: The THERAFLEX MB-Plasma and THERAFLEX UV-Platelets systems effectively inactivated JEV in plasma or PCs, and thus these PI technologies could be an effective option to reduce the risk of JEV transfusion transmission.


Sujet(s)
Virus de l'encéphalite japonaise (espèce)/croissance et développement , Lumière , Bleu de méthylène/pharmacologie , Plasma sanguin/virologie , Inactivation virale , Humains , Inactivation virale/effets des médicaments et des substances chimiques , Inactivation virale/effets des radiations
10.
Transfusion ; 60(8): 1821-1827, 2020 08.
Article de Anglais | MEDLINE | ID: mdl-32537745

RÉSUMÉ

BACKGROUND: UVC illumination of agitated platelet concentrates (PCs) inactivates pathogens and white blood cells by modifications of their nucleic acids. Related effects on mitochondrial DNA (mtDNA) in platelets serve as a basis for an efficient monitoring suited for routine quality control (QC) of this purely physical pathogen reduction technology. STUDY DESIGN AND METHODS: Samples from PCs (n = 530) were tested with an established LightCycler PCR (LC PCR) for QC of the UVC procedure. RNR2 and TRNK/ATP8 genes were sequenced in the PCs (n = 21) with out-of-specification results in the LC PCR. A digital droplet PCR (ddPCR) was developed to minimize the outliers and cross-validated by testing the 530 PCs. The ddPCR was further evaluated in a subgroup of 300 PCs without mtDNA extraction and in samples from systematic variations of UVC dose and agitation speed. RESULTS: Apheresis PCs (n = 380) resulted in 5.3% outliers in LC PCR versus only 0.7% in buffy coat pool PCs (n = 150). Sequencing of these outliers revealed single-nucleotide polymorphisms in the primer- and probe-binding sites of LC PCR. The development of a ddPCR assay with modified probe sequences reduced the outliers to 0.4%. The ddPCR analysis of PCs both with and without mtDNA extraction demonstrated low intra- and interassay variabilities and congruent results also compared to LC PCR. Experiments varying the UVC dose and the agitation speed demonstrated that the ddPCR results closely reflect functional effects of the UVC treatment. CONCLUSION: The ddPCR assay offers a valid and reliable tool for QC of routine production of the UVC-treated PCs as well as for monitoring treatment conditions during optimization of the UVC procedure.


Sujet(s)
Buffy coat , Plaquettes , ADN mitochondrial/génétique , Protéines mitochondriales/génétique , Réaction de polymérisation en chaîne , Polymorphisme de nucléotide simple , Rayons ultraviolets , Humains , Thrombocytaphérèse , Contrôle de qualité
11.
Vox Sang ; 115(7): 555-561, 2020 Oct.
Article de Anglais | MEDLINE | ID: mdl-32383163

RÉSUMÉ

BACKGROUND AND OBJECTIVES: As previous investigations have shown, THERAFLEX UV-Platelets, a UVC-based pathogen inactivation (PI) system, is effective against non-enveloped transfusion-relevant viruses such as hepatitis A virus (HAV), which are insensitive to most PI treatments for blood products. This study investigated the PI efficacy of THERAFLEX UV-Platelets against HEV in platelet concentrates (PCs). MATERIALS AND METHODS: Buffy coat-derived PCs in additive solution were spiked with cell culture-derived HEV and treated with the THERAFLEX UV-Platelets system using various doses of UVC (0·05, 0·10, 0·15 and 0·20 (standard) J/cm2 ). Titres of infectious virus in pre- and post-treatment samples were determined using a large-volume plating assay to improve the detection limit of the virus assay. RESULTS: THERAFLEX UV-Platelets dose-dependently inactivated HEV in PCs. The standard UVC dose inactivated the virus to below the limit of detection, corresponding to a mean log reduction of greater than 3·5. CONCLUSION: Our study demonstrates that the THERAFLEX UV-Platelets system effectively inactivates HEV in PCs.


Sujet(s)
Plaquettes/virologie , Sécurité transfusionnelle/méthodes , Virus de l'hépatite E/effets des radiations , Rayons ultraviolets , Humains
12.
Vox Sang ; 115(3): 146-151, 2020 Apr.
Article de Anglais | MEDLINE | ID: mdl-31930543

RÉSUMÉ

BACKGROUND: Emerging viruses like severe acute respiratory syndrome coronavirus (SARS-CoV), Crimean-Congo haemorrhagic fever virus (CCHFV) and Nipah virus (NiV) have been identified to pose a potential threat to transfusion safety. In this study, the ability of the THERAFLEX UV-Platelets and THERAFLEX MB-Plasma pathogen inactivation systems to inactivate these viruses in platelet concentrates and plasma, respectively, was investigated. MATERIALS AND METHODS: Blood products were spiked with SARS-CoV, CCHFV or NiV, and then treated with increasing doses of UVC light (THERAFLEX UV-Platelets) or with methylene blue (MB) plus increasing doses of visible light (MB/light; THERAFLEX MB-Plasma). Samples were taken before and after treatment with each illumination dose and tested for residual infectivity. RESULTS: Treatment with half to three-fourths of the full UVC dose (0·2 J/cm2 ) reduced the infectivity of SARS-CoV (≥3·4 log), CCHFV (≥2·2 log) and NiV (≥4·3 log) to the limit of detection (LOD) in platelet concentrates, and treatment with MB and a fourth of the full light dose (120 J/cm2 ) decreased that of SARS-CoV (≥3·1 log), CCHFV (≥3·2 log) and NiV (≥2·7 log) to the LOD in plasma. CONCLUSION: Our study demonstrates that both THERAFLEX UV-Platelets (UVC) and THERAFLEX MB-Plasma (MB/light) effectively reduce the infectivity of SARS-CoV, CCHFV and NiV in platelet concentrates and plasma, respectively.


Sujet(s)
Virus de la fièvre hémorragique de Crimée-Congo/effets des radiations , Lumière , Bleu de méthylène/pharmacologie , Virus Nipah/effets des radiations , Virus du SRAS/effets des radiations , Rayons ultraviolets , Inactivation virale , Plaquettes/virologie , Transfusion sanguine , Virus de la fièvre hémorragique de Crimée-Congo/effets des médicaments et des substances chimiques , Humains , Virus Nipah/effets des médicaments et des substances chimiques , Plasma sanguin/virologie , Virus du SRAS/effets des médicaments et des substances chimiques
13.
Transfusion ; 59(7): 2223-2227, 2019 07.
Article de Anglais | MEDLINE | ID: mdl-31050821

RÉSUMÉ

BACKGROUND: Yellow fever virus (YFV) is endemic to tropical and subtropical areas in South America and Africa, and is currently a major public health threat in Brazil. Transfusion transmission of the yellow fever vaccine virus has been demonstrated, which is indicative of the potential for viral transfusion transmission. An approach to manage the potential YFV transfusion transmission risk is the use of pathogen inactivation (PI) technology systems, such as THERAFLEX MB-Plasma and THERAFLEX UV-Platelets (Macopharma). We aimed to investigate the efficacy of these PI technology systems to inactivate YFV in plasma or platelet concentrates (PCs). STUDY DESIGN AND METHODS: YFV spiked plasma units were treated using THERAFLEX MB-Plasma system (visible light doses: 20, 40, 60, and 120 [standard] J/cm2 ) in the presence of methylene blue (approx. 0.8 µmol/L) and spiked PCs were treated using THERAFLEX UV-Platelets system (ultraviolet C doses: 0.05, 0.10, 0.15, and 0.20 [standard] J/cm2 ). Samples were taken before the first and after each illumination dose and tested for residual virus using a modified plaque assay. RESULTS: YFV infectivity was reduced by an average of 4.77 log or greater in plasma treated with the THERAFLEX MB-Plasma system and by 4.8 log or greater in PCs treated with THERAFLEX UV-Platelets system. CONCLUSIONS: Our study suggests the THERAFLEX MB-Plasma and the THERAFLEX UV-Platelets systems can efficiently inactivate YFV in plasma or PCs to a similar degree as that for other arboviruses. Given the reduction levels observed in this study, these PI technology systems could be an effective option for managing YFV transfusion-transmission risk in plasma and PCs.


Sujet(s)
Plaquettes/virologie , Lumière , Bleu de méthylène/pharmacologie , Plasma sanguin/virologie , Rayons ultraviolets , Virus de la fièvre jaune/effets des médicaments et des substances chimiques , Afrique , Animaux , Banque du sang/méthodes , Transfusion sanguine , Chlorocebus aethiops , Transmission de maladie infectieuse/prévention et contrôle , Humains , Amérique du Sud , Cellules Vero , Fièvre jaune/transmission , Virus de la fièvre jaune/effets des radiations
14.
Transfusion ; 59(4): 1324-1332, 2019 04.
Article de Anglais | MEDLINE | ID: mdl-30588633

RÉSUMÉ

BACKGROUND: The THERAFLEX UV-Platelets system (Maco Pharma) uses ultraviolet C (UVC) light for pathogen inactivation (PI) of platelet concentrates (PCs) without any additional photoactive compound. The aim of the study was to systematically investigate bacterial inactivation with this system under conditions of intended use. STUDY DESIGN AND METHODS: The robustness of the system was evaluated by assessing its capacity to inactivate high concentrations of different bacterial species in accordance with World Health Organization guidelines. The optimal use of the PI system was explored in time-to-treatment experiments by testing its ability to sterilize PCs contaminated with low levels of bacteria on the day of manufacture (target concentration, 100 colony-forming units/unit). The bacteria panel used for spiking experiments in this study included the World Health Organization International Repository Platelet Transfusion Relevant Reference Strains (n = 14), commercially available strains (n = 13), and in-house clinical isolates (n = 2). RESULTS: Mean log reduction factors after UVC treatment ranged from 3.1 to 7.5 and varied between different strains of the same species. All PCs (n = 12/species) spiked with up to 200 colony-forming units/bag remained sterile until the end of storage when UVC treated 6 hours after spiking. UVC treatment 8 hours after spiking resulted in single breakthrough contaminations with the fast-growing species Escherichia coli and Streptococcus pyogenes. CONCLUSION: The UVC-based THERAFLEX UV-Platelets system efficiently inactivates transfusion-relevant bacterial species in PCs. The comprehensive data from this study may provide a valuable basis for the optimal use of this UVC-based PI system.


Sujet(s)
Bactéries/effets des radiations , Plaquettes/microbiologie , Transfusion de plaquettes/méthodes , Stérilisation/méthodes , Rayons ultraviolets , Humains
15.
Transfusion ; 58(11): 2669-2674, 2018 11.
Article de Anglais | MEDLINE | ID: mdl-30267410

RÉSUMÉ

BACKGROUND: Nonenveloped transfusion-transmissible viruses such as hepatitis A virus (HAV) and hepatitis E virus (HEV) are resistant to many of the common virus inactivation procedures for blood products. This study investigated the pathogen inactivation (PI) efficacy of the THERAFLEX UV-Platelets system against two nonenveloped viruses: HAV and feline calicivirus (FCV), in platelet concentrates (PCs). STUDY DESIGN AND METHODS: PCs in additive solution were spiked with high titers of cell culture-derived HAV and FCV, and treated with ultraviolet C at various doses. Pre- and posttreatment samples were taken and the level of viral infectivity determined at each dose. For some samples, large-volume plating was performed to improve the detection limit of the virus assay. RESULTS: THERAFLEX UV-Platelets reduced HAV titers in PCs to the limit of detection, resulting in a virus reduction factor of greater than 4.2 log steps, and reduced FCV infectivity in PCs by 3.0 ± 0.2 log steps. CONCLUSIONS: THERAFLEX UV-Platelets effectively inactivates HAV and FCV in platelet units.


Sujet(s)
Plaquettes/effets des radiations , Plaquettes/virologie , Calicivirus félin/effets des radiations , Virus de l'hépatite A/effets des radiations , Rayons ultraviolets , Animaux , Chats , Lignée cellulaire , Humains
16.
Transfusion ; 58(9): 2202-2207, 2018 09.
Article de Anglais | MEDLINE | ID: mdl-29732571

RÉSUMÉ

BACKGROUND: Ebola virus (EBOV) and Middle East respiratory syndrome coronavirus (MERS-CoV) have been identified as potential threats to blood safety. This study investigated the efficacy of the THERAFLEX UV-Platelets and THERAFLEX MB-Plasma pathogen inactivation systems to inactivate EBOV and MERS-CoV in platelet concentrates (PCs) and plasma, respectively. STUDY DESIGN AND METHODS: PCs and plasma were spiked with high titers of cell culture-derived EBOV and MERS-CoV, treated with various light doses of ultraviolet C (UVC; THERAFLEX UV-Platelets) or methylene blue (MB) plus visible light (MB/light; THERAFLEX MB-Plasma), and assessed for residual viral infectivity. RESULTS: UVC reduced EBOV (≥4.5 log) and MERS-CoV (≥3.7 log) infectivity in PCs to the limit of detection, and MB/light decreased EBOV (≥4.6 log) and MERS-CoV (≥3.3 log) titers in plasma to nondetectable levels. CONCLUSIONS: Both THERAFLEX UV-Platelets (UVC) and THERAFLEX MB-Plasma (MB/light) effectively reduce EBOV and MERS-CoV infectivity in platelets and plasma, respectively.


Sujet(s)
Plaquettes/virologie , Ebolavirus/effets des médicaments et des substances chimiques , Ebolavirus/effets des radiations , Lumière , Bleu de méthylène/pharmacologie , Coronavirus du syndrome respiratoire du Moyen-Orient/effets des médicaments et des substances chimiques , Coronavirus du syndrome respiratoire du Moyen-Orient/effets des radiations , Plasma sanguin/virologie , Rayons ultraviolets , Inactivation virale/effets des médicaments et des substances chimiques , Inactivation virale/effets des radiations , Animaux , Chlorocebus aethiops , Infections à coronavirus/sang , Infections à coronavirus/prévention et contrôle , Infections à coronavirus/virologie , Ebolavirus/isolement et purification , Fièvre hémorragique à virus Ebola/sang , Fièvre hémorragique à virus Ebola/prévention et contrôle , Fièvre hémorragique à virus Ebola/virologie , Humains , Coronavirus du syndrome respiratoire du Moyen-Orient/isolement et purification , Cellules Vero , Virémie/virologie
17.
Transfusion ; 58(3): 758-765, 2018 03.
Article de Anglais | MEDLINE | ID: mdl-29282743

RÉSUMÉ

BACKGROUND: Several ultraviolet (UV) light-based pathogen inactivation (PI) technologies for platelet (PLT) products have been developed or are under development. Upon implementation of PI technologies, quality control measures are required to ensure consistent efficiency of the treatment process. Previous reports showed that amotosalen/UVA and riboflavin/UV-based PI technologies induce modifications of the PLT-derived mitochondrial DNA (mtDNA) that can be detected by polymerase chain reaction (PCR) inhibition assays. In this study, we sought to establish a PCR inhibition assay to document the impact of ultraviolet C (UVC) treatment with the THERAFLEX UV-Platelets system on the mitochondrial genome in PLT concentrates (PCs). STUDY DESIGN AND METHODS: A multiplex real-time PCR inhibition assay with simultaneous short-amplicon (143 bp) and long-amplicon (794 bp) amplification was developed to detect mtDNA modifications in PLTs after UVC treatment. Assay performance was tested in UVC-treated and untreated, plasma-reduced pooled PCs, and apheresis PCs and challenged using PCs manufactured for a clinical trial under routine-like conditions. RESULTS: UVC illumination of PLTs resulted in dose-dependent inhibition of mtDNA amplification for the larger amplicon. Amplification of the shorter amplicon was not affected by UVC treatment. Evaluation of 283 blinded apheresis and pooled PLT samples from routine-like PC production resulted in prediction of UVC treatment status with 100% accuracy. CONCLUSION: The proposed dual-amplicon size real-time mtDNA PCR assay effectively detects nucleic acid damage induced by UVC illumination of PLTs and could be useful as an informative indicator of PI quality of the THERAFLEX UV-Platelets system.


Sujet(s)
Plaquettes , Pathogènes transmissibles par le sang , ADN mitochondrial/génétique , Désinfection/méthodes , Réaction de polymérisation en chaine multiplex/méthodes , Rayons ultraviolets , Femelle , Humains , Mâle , Contrôle de qualité
18.
Transfusion ; 57(11): 2677-2682, 2017 11.
Article de Anglais | MEDLINE | ID: mdl-28718518

RÉSUMÉ

BACKGROUND: Zika virus (ZIKV) has emerged as a potential threat to transfusion safety worldwide. Pathogen inactivation is one approach to manage this risk. In this study, the efficacy of the THERAFLEX UV-Platelets system and THERAFLEX MB-Plasma system to inactivate ZIKV in platelet concentrates (PCs) and plasma was investigated. STUDY DESIGN AND METHODS: PCs spiked with ZIKV were treated with the THERAFLEX UV-Platelets system at 0.05, 0.10, 0.15, and 0.20 J/cm2 UVC. Plasma spiked with ZIKV was treated with the THERAFLEX MB-Plasma system at 20, 40, 60, and 120 J/cm2 light at 630 nm with at least 0.8 µmol/L methylene blue (MB). Samples were taken before the first and after each illumination dose and tested for residual virus. For each system the level of viral reduction was determined. RESULTS: Treatment of PCs with THERAFLEX UV-Platelets system resulted in a mean of 5 log reduction in ZIKV infectivity at the standard UVC dose (0.20 J/cm2 ), with dose dependency observed with increasing UVC dose. For plasma treated with MB and visible light, ZIKV infectivity was reduced by a mean of at least 5.68 log, with residual viral infectivity reaching the detection limit of the assay at 40 J/cm2 (one-third the standard dose). CONCLUSIONS: Our study demonstrates that the THERAFLEX UV-Platelets system and THERAFLEX MB-Plasma system can reduce ZIKV infectivity in PCs and pooled plasma to the detection limit of the assays used. These findings suggest both systems have the capacity to be an effective option to manage potential ZIKV transfusion transmission risk.


Sujet(s)
Plaquettes/virologie , Plasma sanguin/virologie , Infection par le virus Zika/prévention et contrôle , Virus Zika/effets des radiations , Humains , Lumière , Limite de détection , Bleu de méthylène/pharmacologie , Rayons ultraviolets , Inactivation virale/effets des médicaments et des substances chimiques , Inactivation virale/effets des radiations , Virus Zika/effets des médicaments et des substances chimiques , Virus Zika/pathogénicité , Infection par le virus Zika/transmission
19.
Transfusion ; 56(6 Pt 2): 1548-55, 2016 06.
Article de Anglais | MEDLINE | ID: mdl-26926832

RÉSUMÉ

BACKGROUND: Arboviruses, including dengue (DENV 1-4), chikungunya (CHIKV), and Ross River (RRV), are emerging viruses that are a risk for transfusion safety globally. An approach for managing this risk is pathogen inactivation, such as the THERAFLEX UV-Platelets system. We investigated the ability of this system to inactivate the above mentioned arboviruses. STUDY DESIGN AND METHODS: DENV 1-4, CHIKV, or RRV were spiked into buffy coat (BC)-derived platelet (PLT) concentrates in additive solution and treated with the THERAFLEX UV-Platelets system at the following doses: 0.05, 0.1, 0.15, and 0.2 J/cm(2) (standard dose). Pre- and posttreatment samples were taken for each dose, and the level of viral infectivity was determined. RESULTS: At the standard ultraviolet C (UVC) dose (0.2 J/cm(2) ), viral inactivation of at least 4.43, 6.34, and 5.13 log or more, was observed for DENV 1-4, CHIKV, and RRV, respectively. A dose dependency in viral inactivation was observed with increasing UVC doses. CONCLUSIONS: Our study has shown that DENV, CHIKV, and RRV, spiked into BC-derived PLT concentrates, were inactivated by the THERAFLEX UV-Platelets system to the limit of detection of our assay, suggesting that this system could contribute to the safety of PLT concentrates with respect to these emerging arboviruses.


Sujet(s)
Plaquettes/virologie , Transfusion de plaquettes/normes , Virus à ARN/effets des radiations , Rayons ultraviolets , Inactivation virale/effets des radiations , Sécurité transfusionnelle/méthodes , Virus du chikungunya/effets des radiations , Virus de la dengue/effets des radiations , Relation dose-effet des rayonnements , Humains , Limite de détection , Transfusion de plaquettes/effets indésirables , Virus de la rivière Ross/effets des radiations
20.
J Gen Virol ; 96(9): 2636-2642, 2015 Sep.
Article de Anglais | MEDLINE | ID: mdl-26041875

RÉSUMÉ

The recent discovery of hepatitis C virus (HCV)-related viruses in different animal species has raised new speculations regarding the origin of HCV and the possibility of a zoonotic source responsible for the endemic HCV transmission. As a consequence, these new findings prompt questions regarding the potential for cross-species transmissions of hepaciviruses. The closest relatives to HCV discovered to date are the non-primate hepaciviruses (NPHVs), which have been described to infect horses. To evaluate the risk of a potential zoonotic transmission, we analysed NPHV RNA and antibodies in humans with occupational exposure to horses in comparison with a low-risk group. Both groups were negative for NPHV RNA, even though low seroreactivities against various NPHV antigens could be detected irrespective of the group. In conclusion, we did not observe evidence of NPHV transmission between horses and humans.


Sujet(s)
Maladies des agriculteurs/virologie , Hepacivirus/physiologie , Hépatite C/médecine vétérinaire , Hépatite C/virologie , Maladies des chevaux/virologie , Zoonoses/transmission , Adulte , Animaux , Femelle , Hepacivirus/classification , Hepacivirus/génétique , Hépatite C/transmission , Maladies des chevaux/transmission , Equus caballus , Humains , Mâle , Adulte d'âge moyen , Exposition professionnelle , Phylogenèse , Zoonoses/virologie