Your browser doesn't support javascript.
loading
Montrer: 20 | 50 | 100
Résultats 1 - 3 de 3
Filtrer
Plus de filtres










Base de données
Gamme d'année
1.
Curr Urol ; 18(2): 155-158, 2024 Jun.
Article de Anglais | MEDLINE | ID: mdl-39176290

RÉSUMÉ

Urinary leak is one of the most significant complications after partial nephrectomy. In case of persistent urine leaks, placement of a ureteral stent is effective but not always sufficient. This study included 5 patients with persistent urinary leak after partial nephrectomy. The patients underwent flexible ureteroscopy wherein we identified the damaged calyx. Subsequently, we performed percutaneous puncture targeting the distal end of the endoscope at this calyx and installed a nephrostomy tube. Then, the endoscope was removed, and the ureter was drained with a stent. Ureteral stenting ensures elimination of urinary leak in most patients after partial nephrectomy. In patients with persistent urinary leak, retrograde endoscopic percutaneous drainage of the pelvicalyceal system is the method of choice because it allows for rapid and effective treatment of urinary fistulas.

2.
Curr Urol ; 18(1): 24-29, 2024 Mar.
Article de Anglais | MEDLINE | ID: mdl-38505158

RÉSUMÉ

Background: The aims were to describe a software-based reconstruction of the patient-specific kidney cavity intraluminal appearance via a head-mounted device and to estimate its feasibility for training novices. Materials and methods: In total, 15 novices were recruited. Each novice was shown a three-dimensional reconstruction of a patient's computed tomography scan, whose kidney was printed. They then joined the surgeon in the operating room and assisted them in detecting the stone during flexible ureteroscopy on the printed model. Then, each participant did a 7-day virtual reality (VR) study followed by virtual navigation of the printed kidney model and came to the operating room to help the surgeon with ureteroscope navigation. The length of the procedure and the number of attempts to find the targeted calyx were compared. Results: With VR training, the length of the procedure (p = 0.0001) and the number of small calyces that were incorrectly identified as containing stones were significantly reduced (p = 0.0001). All the novices become highly motivated to improve their endourological skills further. Participants noticed minimal values for nausea and for disorientation. However, oculomotor-related side effects were defined as significant. Five specialists noticed a good similarity between the VR kidney cavity representation and the real picture, strengthening the potential for the novice's education via VR training. Conclusions: Virtual reality simulation allowed for improved spatial orientation within the kidney cavity by the novices and could be a valuable option for future endourological training and curricula.

3.
Urolithiasis ; 52(1): 16, 2023 Dec 20.
Article de Anglais | MEDLINE | ID: mdl-38117336

RÉSUMÉ

The purpose of this review is to analyze the trend in miniaturization of flexible ureteroscopes over the past decades, identify the advantages and disadvantages, and determine the correlation of individual parameters with release period. Flexible ureteroscopes mentioned in the literature or those commercially available were searched. To minimize the search bias, the instruments were grouped by release date time periods of < 2000 year, 2000-2009, 2010-2019, and 2020 onwards. The final review included only those instrument models for which data on tip size, overall shaft, working length and channel size had been determined. The correlation among features investigated as well as with release period was also determined. 59 models of flexible ureteroscopes (26 fiber optic and 33 digital scopes) were included. Among the different features investigated among fiber optic endoscopes, only the sizes of the distal tip and overall shaft positively correlated with each other. In contrast to their fiber optic counterparts, a strong positive correlation was observed between tip and channel sizes, whereas negative correlation was found between channel size and overall shaft size and working length of digital scopes. Only distal tip of fiber optic flexible ureteroscopes and overall shaft of digital endoscopes were significantly reduced over their evolution. With the development of technology, there has been an improvement of flexible ureteroscopes and one of the indicators of this trend is a decrease in their size. With a definite trend towards miniaturization over the past decades, a significant correlation was observed in tip size and overall shaft for fiber optic and digital endoscopes, respectively.


Sujet(s)
Miniaturisation , Urétéroscopes
SÉLECTION CITATIONS
DÉTAIL DE RECHERCHE