Your browser doesn't support javascript.
loading
Montrer: 20 | 50 | 100
Résultats 1 - 10 de 10
Filtrer
1.
Contemp Clin Trials Commun ; 38: 101260, 2024 Apr.
Article de Anglais | MEDLINE | ID: mdl-38384894

RÉSUMÉ

Introduction: Percutaneous coronary intervention with implantation of a bioresorbable scaffold (BRS) provide the vessel support for a limited period allowing the vessel to restore normal vasomotion after degradation of the BRS, opposed to treatment with drug-eluting stents where the metal persist in the vessel wall. Late lumen loss and reduction in lumen area after implantation have been reported. The purpose of this study was to investigate whether intense pre-dilatation before BRS implantation resulted in less reduction of minimal lumen area at 6- and 12-month follow-up after implantation of a Magmaris BRS (MgBRS). Coronary imaging with optical coherence tomography (OCT) and intravascular ultrasound (IVUS) was assessed to track changes in lumen and vessel dimensions. Methods: The prospective Optimal lesion PreparaTion before Implantation of the Magmaris bioresorbable scaffold In patients with coronary artery Stenosis (OPTIMIS) study randomly assigned eighty-two patients with chronic coronary syndrome to two pre-dilatation treatment strategies. Patients were randomized in a 1:1 ratio to pre-dilatation with either a non-compliant scoring balloon or a standard non-compliant balloon prior to implantation of a MgBRS. The treated segment was evaluated with OCT and IVUS at baseline, after 6 and 12 months to assess changes in lumen and vessel dimensions. The hypothesis was that more intense pre-dilatation with a non-compliant scoring balloon before MgBRS implantation can reduce the risk of late lumen reduction compared to standard pre-dilatation. The power calculation used expected MLA after 6 months (6.22 mm2 for the scoring balloon and 5.01 mm2 for the standard non-compliant balloon), power of 80 %, significance level of 0.05 and expected drop-out rate of 15 %, requiring 82 patients to be enrolled. Results: Eighty-two patients were included in the study. Enrollment was from December 2020 to September 2023. Conclusion: The hypothesis was that more intense pre-dilatation with a non-compliant scoring balloon before MgBRS implantation can reduce the risk of late lumen reduction compared to standard pre-dilatation.

2.
Catheter Cardiovasc Interv ; 103(2): 276-285, 2024 02.
Article de Anglais | MEDLINE | ID: mdl-38091338

RÉSUMÉ

BACKGROUND: Patients with acute coronary syndromes (ACS) may have worse outcomes after percutaneous coronary intervention compared to patients without ACS. AIMS: To compare 5-year efficacy and safety outcomes in patients with and without ACS treated with biodegradable polymers, the ultrathin strut sirolimus-eluting Orsiro stent (O-SES) or the biolimus-eluting Nobori stent (N-BES). METHODS: The Scandinavian Organisation for Randomized Trials with Clinical Outcome VII is a randomized trial comparing O-SES and N-BES in an all-comer setting. Of 2525 patients, 1329 (53%) patients had ACS and 1196 (47%) patients were without ACS. Endpoints were target lesion failure (TLF) (a composite of cardiac death, target lesion myocardial infarction, or target lesion revascularization) and definite stent thrombosis within 5 years. RESULTS: At 5-year follow-up, TLF did not differ significantly between patients with and without ACS (12.3% vs. 13.2%; rate ratio (RR) 1.00; 95% confidence interval (CI): 0.70-1.44), whereas the risk of definite stent thrombosis was increased in patients with ACS (2.3% vs. 1.3; RR: 2.01 [95% CI: 1.01-3.98]). In patients with ACS, the rate of TLF was similar between O-SES and N-BES (12.4% vs. 12.3%; RR: 1.02; 95% CI: 0.74-1.40). The reduced risk of definite stent thrombosis in O-SES treated ACS patients within the first year (0.2% vs. 1.6%; RR: 0.12; 95% CI: 0.02-0.93) was not maintained after 5 years (1.8% vs. 2.7%; RR: 0.77; 95% CI: 0.37-1.63). CONCLUSION: Patients with ACS had an increased risk of stent thrombosis regardless of the stent type used. Long-term outcomes were similar for ACS patients treated with O-SES or N-BES at 5 years.


Sujet(s)
Syndrome coronarien aigu , Acides alcanesulfoniques , Agents cardiovasculaires , Maladie des artères coronaires , Thrombose coronarienne , Endoprothèses à élution de substances , Intervention coronarienne percutanée , Humains , Maladie des artères coronaires/imagerie diagnostique , Maladie des artères coronaires/thérapie , Maladie des artères coronaires/complications , Syndrome coronarien aigu/imagerie diagnostique , Syndrome coronarien aigu/thérapie , Syndrome coronarien aigu/complications , Facteurs de risque , Résultat thérapeutique , Endoprothèses à élution de substances/effets indésirables , Implant résorbable , Conception de prothèse , Agents cardiovasculaires/effets indésirables , Thrombose coronarienne/étiologie , Endoprothèses/effets indésirables , Polymères , Intervention coronarienne percutanée/effets indésirables
3.
Cardiovasc Revasc Med ; 54: 41-46, 2023 09.
Article de Anglais | MEDLINE | ID: mdl-37045636

RÉSUMÉ

BACKGROUND: The relation between the resting full cycle ratio (RFR) and fractional flow reserve (FFR) is not fully understood. This study aims to investigate the influence of coronary microvascular dysfunction, assessed by the index of microvascular resistance (IMR), on RFR compared to FFR in patients undergoing functional assessment for coronary stenosis. MATERIALS AND METHODS: Two-hundred patients with borderline stenosis underwent functional assessment of RFR, FFR, coronary flow reserve (CFR) and IMR. Retriever operator curve analysis was performed to assess the diagnostic value of RFR in patients with (IMR ≥ 24) and (IMR < 24). RESULTS: Median RFR did not differ significantly in patients with IMR ≥ 24 compared to patients with IMR < 24: 0.89 (interquartile range (IQR) 0.84, 0.95) vs. 0.90 (IQR 0.84, 0.92), p = 0.29). FFR was significantly higher in patients with IMR ≥ 24 compared to patients with IMR < 24: median FFR 0.85 (IQR (0.76, 0.92)) vs. 0.82 (IQR 0.73, 0.86), p = 0.009, and median CFR was significantly lower 1.80 (IQR 1.40, 2.55) vs. 2.70 (IQR 1.80, 3.95), p < 0.001. The diagnostic value of RFR was high (Area under the curve (AUC) 0.89 95 % Confidence Interval: [0.85, 0.93]) and AUC did not differ between patients with IMR ≥ 24 compared to patients with IMR < 24: 0.89 vs. 0.90, p = 0.89. An overall optimal cut off of 0.88 was identified. The cut off did not differ significantly between patients with IMR ≥ 24 compared to patients with IMR < 24: 0.88 vs. 0.90, p = 0.397. CONCLUSION: In patients with coronary borderline stenosis, the coronary microvascular function did not influence on the cut off values or AUC of RFR compared to FFR.


Sujet(s)
Sténose coronarienne , Fraction du flux de réserve coronaire , Humains , Sténose pathologique , Coronarographie , Microcirculation , Résistance vasculaire , Vaisseaux coronaires/imagerie diagnostique , Valeur prédictive des tests , Sténose coronarienne/imagerie diagnostique , Cathétérisme cardiaque
4.
Circ Cardiovasc Interv ; 16(1): e012332, 2023 01.
Article de Anglais | MEDLINE | ID: mdl-36649389

RÉSUMÉ

BACKGROUND: Biodegradable polymer drug-eluting stents were developed to improve safety and efficacy outcomes for patients undergoing percutaneous coronary intervention. However, few long-term follow-up efficacy studies are available. The study sought to investigate 5-year results from the SORT OUT VII trial (Scandinavian Organization for Randomized Trials With Clinical Outcome) comparing the biodegradable polymer ultrathin-strut sirolimus-eluting Orsiro stent (O-SES) versus the biodegradable polymer biolimus-eluting Nobori stent (N-BES). METHODS: This registry-based, randomized, multicenter, single-blinded, noninferiority trial compared O-SES and N-BES in an all-comer population. The composite primary end point, target lesion failure, consisted of cardiac death, myocardial infarction related to the target lesion, or target lesion revascularization within 1 year. Follow-up was extended to 5 years. RESULTS: Five-year follow-up was completed for 2521 patients (99.8%). Five-year target lesion failure did not differ between O-SES (12.4%) and N-BES (13.1%; rate ratio [RR], 0.94 [95% CI, 0.75-1.18]). Cardiac death (RR, 0.95 [95% CI, 0.67-1.34]), target myocardial infarction (RR, 1.14 [95% CI, 0.76-1.71]), target lesion revascularization (RR, 0.90 [95% CI, 0.67-1.21]), and definite stent thrombosis rates (RR, 0.73 [95% CI, 0.41-1.33]) did not differ significantly between the 2 stents. Within the first year, definite ST was significantly lower for O-SES (0.4%) compared to N-BES (1.2%; RR, 0.33 [95% CI, 0.12-0.92]), but no difference was from 1 through 5 years: O-SES 1.2% and N-BES 0.9% (RR, 1.28 [95% CI, 0.58-2.82]). CONCLUSIONS: Five years after treatment with biodegradable polymer stents, target lesion failure did not differ among O-SES and N-BES. Definite stent thrombosis was less often seen within the first year in the O-SES but the difference was not maintained after 5 years. REGISTRATION: URL: https://clinicaltrials.gov; Unique identifier: NCT01879358.


Sujet(s)
Maladie des artères coronaires , Endoprothèses à élution de substances , Infarctus du myocarde , Intervention coronarienne percutanée , Humains , Sirolimus/effets indésirables , Maladie des artères coronaires/imagerie diagnostique , Maladie des artères coronaires/thérapie , Facteurs de risque , Résultat thérapeutique , Implant résorbable , Infarctus du myocarde/étiologie , Polymères , Intervention coronarienne percutanée/effets indésirables , Conception de prothèse
5.
Qual Life Res ; 32(1): 59-69, 2023 Jan.
Article de Anglais | MEDLINE | ID: mdl-35969332

RÉSUMÉ

PURPOSE: The objectives amongst cardiac patients with and without type 2 diabetes were to (i) describe self-reported characteristics as health-related quality of life (HRQoL), health behaviour, body mass index (BMI) and physical shape and to (ii) investigate the association between self-reported characteristics and 1- and 3-year mortality. METHODS: Adult patients (≥ 18 years) discharged with a cardiac diagnosis were invited to participate in a national survey, DenHeart. Self-reported characteristics included HRQoL (EQ-5D-5L and HeartQol), health behaviour (alcohol and smoking), BMI and physical shape. Data were linked to national registries. The association between self-reported characteristics and 1- and 3-year mortality were investigated using the Cox Proportional Hazard Regression model, reported as hazard ratios (HR) with 95% confidence intervals (CI). RESULTS: In total, 16,659 cardiac responders were included (n = 2,205 with type 2 diabetes, n = 14,454 without type 2 diabetes). Self-reported characteristics were worse amongst cardiac patients with type 2 diabetes compared to those without. After three years, the mortality rate was 14% amongst responders with diabetes and 7% amongst responders without type 2 diabetes (p ≤ 0.001). Better HRQoL was associated with a reduced risk of mortality amongst both groups. "Never been smoking" significantly reduced the risk of 1- and 3-year mortality amongst cardiac patients without diabetes, whereas good physical shape was associated with a reduced risk across both groups. CONCLUSION: HRQoL, health behaviour, BMI and physical shape are significantly worse amongst cardiac patients with type 2 diabetes. Better HRQoL was associated with a reduced risk of mortality amongst both groups, whereas other self-reported characteristics and the mortality risk varied.


Sujet(s)
Diabète de type 2 , Qualité de vie , Adulte , Humains , Qualité de vie/psychologie , Autorapport , Enquêtes et questionnaires
6.
Catheter Cardiovasc Interv ; 99(4): 1095-1103, 2022 03.
Article de Anglais | MEDLINE | ID: mdl-35043539

RÉSUMÉ

This sub-study of the SORT OUT IX trial sought to compare clinical outcomes between patients with diabetes randomized to implantation of either the polymer-free biolimus A9-coated BioFreedom stent (BF-BES) or the ultra-thin strut, biodegradable polymer sirolimus-eluting Orsiro stent (O-SES). Patients with diabetes have an increased risk of target lesion failure (TLF) after percutaneous coronary intervention (PCI). The impact of different stent types in patients with diabetes is still discussed. A total of 607 of the 3151 patients (19.3%) enrolled in the SORT OUT IX study had diabetes. Randomization was stratified by patients with/without diabetes; 304 received BF-BES and 303 O-SES. The primary endpoint was TLF, which was a composite of cardiac death, myocardial infarction (not related to other than the index lesion) and target lesion revascularization (TLR) within 1 year. After 1 year, patients with diabetes had higher TLF (7.2% vs. 3.7%, incidence rate ratio [IRR]: 1.65; 95% confidence interval [CI]: 1.08-2.50), than patients without diabetes. TLF did not differ significantly between BF-BES and O-SES in patients with diabetes (8.2% vs. 6.3%, IRR: 1.17; 95% CI: 0.63-2.20). In patients with diabetes, cardiac death occurred in 2.3% of BF-BES and in 3.6% of O-SES (IRR: 0.58; 95% CI: 0.23-1.45) and TLR occurred in 5.3% and 2.3% of BF-BES and O-SES, respectively (IRR: 2.12; 95% CI: 0.81-5.56). Definite stent thrombosis rates of 1.3% were found in both stent types. Patients with diabetes had higher 1-year TLF rate after PCI compared to patients without diabetes, whereas TLF did not differ significantly between the two stent types BF-BES and O-SES in patients with diabetes.


Sujet(s)
Maladie des artères coronaires , Diabète , Endoprothèses à élution de substances , Intervention coronarienne percutanée , Implant résorbable , Maladie des artères coronaires/imagerie diagnostique , Maladie des artères coronaires/étiologie , Maladie des artères coronaires/thérapie , Mort , Diabète/diagnostic , Diabète/épidémiologie , Humains , Intervention coronarienne percutanée/effets indésirables , Polymères , Conception de prothèse , Endoprothèses , Résultat thérapeutique
7.
Cardiovasc Revasc Med ; 40: 101-110, 2022 07.
Article de Anglais | MEDLINE | ID: mdl-34949544

RÉSUMÉ

BACKGROUND: The purpose of a bioresorbable scaffold (BRS) is to provide radial support during coronary healing. In this study, coronary artery healing after optical coherence tomography (OCT)- versus angiography-guided magnesium BRS (MBRS) implantation in patients with non-ST-segment-elevation myocardial infarction (NSTEMI) is compared. METHODS: 75 patients were randomized 1:1 to OCT- or angiography-guided implantation of a MBRS with protocolled pre- and post-dilation. In the OCT-guided group, prespecified criteria indicating additional intervention were (1) scaffold under-expansion, (2) strut malapposition, (3) edge dissection, and (4) residual stenosis at distal or proximal reference segments. The primary endpoint was OCT-derived healing stage at 6 months. RESULTS: At 6 months, there was no difference in average healing stage between OCT- and angiography-guided intervention (4.6 [interquartile range (IQR): 4.5-4.7] versus 4.5 [IQR: 4.3-4.7]; p = 0.54). The MBRSs were completely resolved in 77.0% [IQR: 68.5-85.5] versus 76.5% [IQR: 67.9-85.5]; (p = 0.97). Minimal lumen area (MLA) was reduced at 6 months in both the OCT- (32.3%; p < 0.01) and the angiography-guided group (21.3%; p < 0.01), however OCT-guided implantation was associated with a greater reduction of total lumen volume (-27.1 ± 32.5 mm3 versus -5.0 ± 32.9 mm3; p < 0.01) and MLA (-2.3 ± 1.6 mm2 vs. -1.4 ± 1.4 mm2; p = 0.02). CONCLUSIONS: In NSTEMI patients, OCT-guidance with protocolled pre- and post-dilation of MBRS implantation showed similar healing pattern at 6 months compared to angiography-guidance alone. CLINICAL TRIAL REGISTRATION: The Coronary Artery Healing Process after Optical Coherence Tomography Guided Percutaneous Coronary Intervention with Magmaris Bioresorbable Scaffold in Patients with Non-ST-Segment-Elevation Myocardial Infarction: (HONEST) trial is registered with ClinicalTrials.gov, NCT03016624.


Sujet(s)
Infarctus du myocarde sans sus-décalage du segment ST , Intervention coronarienne percutanée , Infarctus du myocarde avec sus-décalage du segment ST , Implant résorbable , Coronarographie/méthodes , Vaisseaux coronaires/imagerie diagnostique , Vaisseaux coronaires/chirurgie , Humains , Magnésium , Infarctus du myocarde sans sus-décalage du segment ST/imagerie diagnostique , Infarctus du myocarde sans sus-décalage du segment ST/thérapie , Intervention coronarienne percutanée/effets indésirables , Intervention coronarienne percutanée/méthodes , Conception de prothèse , Tomographie par cohérence optique/méthodes , Résultat thérapeutique
8.
Coron Artery Dis ; 31(8): 671-677, 2020 12.
Article de Anglais | MEDLINE | ID: mdl-32868663

RÉSUMÉ

AIMS: This study sought to evaluate the incidence of ruptured plaques and nonruptured plaques (NRP) and to compare patient characteristics and detailed plaque morphology features between the two culprit types in ST-segment elevation myocardial infarction (STEMI) patients, using optical coherence tomography (OCT). METHODS AND RESULTS: Using OCT, the culprit lesions in patients with STEMI were assessed prior to stent implantation. The culprit lesion was categorized as ruptured plaques or NRP, and the plaque components were evaluated. Fifty-two patients (69.3%) presented with ruptured plaques and 23 (30.7%) with NRP. Patients with NRP were younger (58.0 ± 10.4 vs 64.7 ± 9.9 years, P = 0.01) and more often smokers (72.7% vs 37.1%, P = 0.001), compared to ruptured plaques. NRP contained significantly more fibrotic plaque (20.0% [interquartile range (IQR) 13.7-29.8] vs 11.3% [IQR 6.9-18.1], P = 0.005), but less lipidic plaque (44.0% ± 13.7 vs 59.3% ± 13.6, P < 0.001), less superficial [5.0% (IQR 2.8-7.5) vs 8.1% (IQR 5.7-11.0), P = 0.005] and profound macrophages [0.9% (IQR 0.0-1.7) vs 2.2% (IQR 0.9-4.7), P = 0.003]. The prevalence, numbers and lengths of thin-cap fibroatheroma (TCFA) were significantly lower in NRP, compared to ruptured plaques [47.8% vs 88.5%, 0 (IQR 0-1) vs 1 (IQR 1-2) and 0 mm (IQR 0-2.7) vs 4.5 mm (IQR 2.3-7.7), P < 0.001]. CONCLUSIONS: One-third of STEMI patients had culprit lesions without an OCT-detectable ruptured plaque. Culprit lesions with NRP contained less vulnerable plaque components, such as lipid plaque, TCFAs and macrophages compared to ruptured plaques.


Sujet(s)
Vaisseaux coronaires , Plaque d'athérosclérose , Soins préopératoires/méthodes , Infarctus du myocarde avec sus-décalage du segment ST , Tomographie par cohérence optique/méthodes , Facteurs âges , Coronarographie/méthodes , Vaisseaux coronaires/imagerie diagnostique , Vaisseaux coronaires/anatomopathologie , Danemark/épidémiologie , Femelle , Humains , Mâle , Adulte d'âge moyen , Intervention coronarienne percutanée/méthodes , Plaque d'athérosclérose/imagerie diagnostique , Plaque d'athérosclérose/anatomopathologie , Facteurs de risque , Rupture spontanée , Infarctus du myocarde avec sus-décalage du segment ST/diagnostic , Infarctus du myocarde avec sus-décalage du segment ST/épidémiologie , Indice de gravité de la maladie , Fumer/épidémiologie
9.
EuroIntervention ; 14(8): 926-934, 2018 Oct 20.
Article de Anglais | MEDLINE | ID: mdl-29360067

RÉSUMÉ

AIMS: The aim of the study was to evaluate the incidence and causes of rehospitalisation within one year after percutaneous coronary intervention (PCI) in a country where the National Health Service provides universal tax-supported healthcare, guaranteeing residents free hospital access. METHODS AND RESULTS: Between January 2010 and September 2014, 17,111 patients were treated with PCI in two University Hospitals in Western Denmark. Patients who were readmitted within one year after PCI were identified. The overall one-year readmission rate was 50.4%. The cause was angina/myocardial infarction (MI) in 4,282 patients (49.7%), and other reasons in 4,334 (50.3%). Predictors of angina/MI-related readmissions were female gender (odds ratio [OR] 1.15, 95% confidence interval [CI]: 1.07-1.25), diabetes (OR 1.14, 95% CI: 1.04-1.26), age (per 10-year increase) (OR 0.86, 95% CI: 0.83-0.88), and indication for index PCI (stable angina pectoris as reference): ST-segment elevation myocardial infarction (OR 1.34, 95% CI: 1.23-1.47) and non-ST-segment elevation myocardial infarction (OR 1.18, 95% CI: 1.08-1.29). Predictors for other readmissions were female gender (OR 1.09, 95% CI: 1.01-1.18), diabetes (OR 1.29, 95% CI: 1.18-1.42), age (OR 1.30, 95% CI: 1.26-1.34) and Charlson comorbidity index ≥3 (OR 3.03, 95% CI: 2.71-3.27). CONCLUSIONS: In an unselected patient cohort treated with PCI, half of the patients were rehospitalised within one year, highlighting the impact of comorbidity in patients with ischaemic heart disease.


Sujet(s)
Angor stable , Intervention coronarienne percutanée , Danemark , Femelle , Humains , Mâle , Réadmission du patient , Études rétrospectives , Facteurs de risque , Résultat thérapeutique
10.
Cardiovasc Revasc Med ; 19(3 Pt B): 376-379, 2018.
Article de Anglais | MEDLINE | ID: mdl-29033367

RÉSUMÉ

A 60-year old woman with non-ST-segment elevation myocardial infarction, underwent coronary angiogram combined with optical coherence tomography (OCT) revealing a long dissection in the right coronary artery. The patient experienced peri-procedural chest pain, the electrocardiogram showed ST-segment elevations, and compromised coronary blood flow, why mechanical revascularization with percutaneous coronary intervention (PCI) was indicated. At 1-month follow-up, OCT revealed early, competent vascular healing, and a distal stenosis was treated with PCI. The patient has been asymptomatic since the procedure for three years.


Sujet(s)
Syndrome coronarien aigu/imagerie diagnostique , Angioplastie coronaire par ballonnet/instrumentation , Anomalies congénitales des vaisseaux coronaires/imagerie diagnostique , Vaisseaux coronaires/imagerie diagnostique , Infarctus du myocarde avec sus-décalage du segment ST/imagerie diagnostique , Endoprothèses , Tomographie par cohérence optique , Maladies vasculaires/congénital , Cicatrisation de plaie , Syndrome coronarien aigu/étiologie , Syndrome coronarien aigu/chirurgie , Coronarographie , Anomalies congénitales des vaisseaux coronaires/complications , Anomalies congénitales des vaisseaux coronaires/chirurgie , Vaisseaux coronaires/chirurgie , Femelle , Humains , Adulte d'âge moyen , Valeur prédictive des tests , Infarctus du myocarde avec sus-décalage du segment ST/étiologie , Infarctus du myocarde avec sus-décalage du segment ST/chirurgie , Résultat thérapeutique , Maladies vasculaires/complications , Maladies vasculaires/imagerie diagnostique , Maladies vasculaires/chirurgie
SÉLECTION CITATIONS
DÉTAIL DE RECHERCHE