Your browser doesn't support javascript.
loading
Montrer: 20 | 50 | 100
Résultats 1 - 20 de 103
Filtrer
1.
Arch Oral Biol ; 166: 106032, 2024 Jun 19.
Article de Anglais | MEDLINE | ID: mdl-38943858

RÉSUMÉ

OBJECTIVE: This study aimed to investigate the correlation between genetic factors and the occurrence and progression of temporomandibular disorders (TMDs) using a comprehensive review and meta-analysis. DESIGN: A comprehensive search was conducted using the ScienceDirect, PubMed, Cochrane Library, Dimensions, and Emerald databases. A reviewer selected the study using modified PICO criteria, considering human subjects with TMDs, comparing different genetic factors among TMD and non-TMD patients, and reporting TMD signs and symptoms as outcomes. The methodological standards of the eligible papers were assessed using the Joanna Briggs Institute (JBI) Critical Appraisal Checklist for Non-randomized Experimental Investigations. Information was collected methodically and examined. RESULTS: The electronic database search yielded 851 articles, 19 of which were included in this study. The data analysis showed a significant influence of genetic factors, such as polymorphisms and gene differences, on the development of TMD signs and symptoms, such as myofascial pain, chronic pain, and disc displacement. In addition, gene polymorphism significantly influenced TMD development, with an odds ratio of 2.46 (1.93-3.14) and p of 0.00001. CONCLUSIONS: Genetic factors significantly influenced TMD signs and symptoms, and genetic polymorphisms significantly influenced TMD onset and progression. Further research should be conducted in diverse settings with larger sample sizes to verify and validate these findings.

2.
Photodiagnosis Photodyn Ther ; 48: 104256, 2024 Jun 22.
Article de Anglais | MEDLINE | ID: mdl-38914185

RÉSUMÉ

AIM: This study aimed to assess the effectiveness of photobiomodulation therapy (PBM) in enhancing bone integration with dental implants. METHOD: PubMed, ScienceDirect, the Cochrane Library, Scopus, and Google Scholar were searched. Studies assessing PBM effectiveness with defined intervention/control groups were included, while those lacking specified laser types, involving severe maxillofacial defects or surgery, and not reporting outcomes related to dental implant osseointegration post-PBM therapy were excluded. The studies' risk of bias was assessed using Robvis for randomized controlled trials (RCTs) and ROBINS-I for non-RCTs. The meta-analysis was conducted utilizing a random-effects model at a significance level of 0.01. RESULTS: The study reviewed 26 papers involving 571 patients undergoing dental implant procedures with PBM/Low-Level Laser Therapy (LLLT) or placebo/control. Implant stability quotients (ISQ) analysis showed a non-significant difference (p = 0.06, mean difference: 1.02, 95 % CI: 0.28 to 1.75, I2=28 %), while the Periotest method indicated significant improvement in stability (p < 0.01, mean difference: -0.51, 95 % CI: -0.78 to -0.24, I2=71 %). PBM resulted in a significant bone density increase (p < 0.01, mean difference: 26, 95 % CI: 6.93 to 45.06, I2=91 %), but marginal bone loss showed no significant difference (p = 0.11, mean difference: 0.00, 95 % CI: -0.06 to 0.05, I2=45 %). Implant survival rate did not significantly differ (p = 0.73, mean difference: 1.56, 95 % CI: 0.38 to 6.46, I2=0 %). Most studies raised concerns regarding randomization. CONCLUSION: PBM could improve implant stability, as assessed with Periotest, and increase bone density, enhancing osseointegration. However, implant stability assessed with ISQ, marginal bone loss, and implant survival rate were comparable between the study groups.

3.
Digit Health ; 10: 20552076241260837, 2024.
Article de Anglais | MEDLINE | ID: mdl-38840660

RÉSUMÉ

Objective: This study aimed to provide valuable insights into the current research status and gaps in digital intraoral scanner literature in dentistry. Methodology: Scopus Search Query TITLE-ABS-KEY (intraoral AND scanners AND (dentistry OR digital AND dentistry)). The search query used in Scopus for the bibliometric analysis was "TITLE-ABS-KEY (intraoral AND scanners AND (dentistry OR digital AND dentistry))." This query indicates that the analysis focused on documents in which the title, abstract, or keywords contained the terms "intraoral," "scanners," and either "dentistry" or "digital dentistry." Results: The analysis covers a timespan from 1998 to 2023 and includes 331 documents sourced from 136 publications. The annual growth rate of research in this field is reported to be 15.9%, indicating a steady increase over time. Among the top sources, the "Journal of Esthetic and Restorative Dentistry" and the "Journal of Prosthetic Dentistry" have the highest number of articles, indicating their significance in the field. Some notable authors and their corresponding statistics include WÖSTMANN B, with 15 articles and a fractionalized value of 3.16, and SCHLENZ MA, with 14 articles and a fractionalized value of 2.91. The United States has the highest number of articles, indicating a significant presence in research publications. Germany closely follows this, demonstrating a notable contribution to the scientific community. Conclusions: This bibliometric analysis of intraoral scanners used in dentistry provided valuable insights into the current state of research and scholarly publications in this field. This analysis sheds light on the trends, patterns, and advancements in the use of these scanners in dental practice.

4.
J Mater Sci Mater Med ; 35(1): 28, 2024 Jun 04.
Article de Anglais | MEDLINE | ID: mdl-38833196

RÉSUMÉ

AIM: This study aimed to comprehensively assess the biocompatibility and toxicity profiles of poly(methyl methacrylate) (PMMA) and its monomeric unit, methyl methacrylate (MMA), crucial components in dental materials for interim prosthetic restorations. METHODOLOGY: Molecular docking was employed to predict the binding affinities, energetics, and steric features of MMA and PMMA with selected receptors involved in bone metabolism and tissue development, including RANKL, Fibronectin, BMP9, NOTCH2, and other related receptors. The HADDOCK standalone version was utilized for docking calculations, employing a Lamarckian genetic algorithm to explore the conformational space of ligand-receptor interactions. Furthermore, molecular dynamics (MD) simulations over 100 nanoseconds were conducted using the GROMACS package to evaluate dynamic actions and structural stability. The LigandScout was utilized for pharmacophore modeling, which employs a shape-based screening approach to identify potential ligand binding sites on protein targets. RESULTS: The molecular docking studies elucidated promising interactions between PMMA and MMA with key biomolecular targets relevant to dental applications. MD simulation results provided strong evidence supporting the structural stability of PMMA complexes over time. Pharmacophore modeling highlighted the significance of carbonyl and hydroxyl groups as pharmacophoric features, indicating compounds with favorable biocompatibility profiles. CONCLUSION: This study underscores the potential of PMMA in dental applications, emphasizing its structural stability, molecular interactions, and safety considerations. These findings lay a foundation for future advancements in dental biomaterials, guiding the design and optimization of materials for enhanced biocompatibility. Future directions include experimental validation of computational findings and the development of PMMA-based dental materials with improved biocompatibility and clinical performance.


Sujet(s)
Matériaux biocompatibles , Matériaux dentaires , Test de matériaux , Simulation de docking moléculaire , Simulation de dynamique moléculaire , Poly(méthacrylate de méthyle) , Matériaux biocompatibles/composition chimique , Poly(méthacrylate de méthyle)/composition chimique , Matériaux dentaires/composition chimique , Humains , Ligands , Simulation numérique , Sites de fixation
5.
Maxillofac Plast Reconstr Surg ; 46(1): 23, 2024 Jun 20.
Article de Anglais | MEDLINE | ID: mdl-38900334

RÉSUMÉ

BACKGROUND: Focal and florid cemento-osseous dysplasia are benign fibro-osseous lesions affecting the quality and quantity of the jawbones. This study aimed to determine the viability of implant-based approaches in the affected patients. MAIN TEXT: Different scientific databases, including PubMed/MEDLINE, Scopus, Web of Science, Embase, the Cochrane Library, and Google Scholar, were searched until October 8, 2023, using a pre-determined search strategy. Two reviewers screened the retrieved reports and extracted the required information from the included studies. The eligibility criteria included English-language case reports/series or clinical trials. The JBI critical appraisal checklist for case reports was used to assess the methodological quality of the included studies. Three studies were deemed eligible to be included in this study out of the initial 202 records found. Five implants were placed in three patients, positioned in the proximity of the lesion area, without any additional treatment to remove the pathology. The mandibular posterior area was the affected site in all patients. Only one implant failed in one patient after 16 years, which was attributed to peri-implantitis and not the lesion. Other implants demonstrated successful maintenance over follow-up periods. CONCLUSIONS: Although the number of the included records was relatively low to draw firm conclusions, it seems that implant-based treatments in patients with focal/florid cemento-osseous dysplasia could be viable, considering a conservative and well-planned approach.

6.
BMC Med Educ ; 24(1): 673, 2024 Jun 17.
Article de Anglais | MEDLINE | ID: mdl-38886698

RÉSUMÉ

OBJECTIVE: To analyze the satisfaction levels, perceptions of developing clinical competencies through objective structured clinical examination and to explore the experiences, challenges, and suggestions of undergraduate dental students. METHODS: The study adopted a mixed-method convergent design. Quantitative data were collected from 303 participants through surveys, evaluating satisfaction levels with objective structured clinical examination (OSCE). Additionally, qualitative insights were gathered through student focus group interviews, fundamental themes were developed from diverse expressions on various aspects of OSCE assessments. The Chi-Square tests, was performed to assess associations between variables. Data integration involved comparing and contrasting quantitative and qualitative findings to derive comprehensive conclusions. RESULTS: The satisfaction rates include 69.4% for the organization of OSCE stations and 57.4% for overall effectiveness. However, a crucial challenge was identified, with only 36.7% of students receiving adequate post-OSCE feedback. Furthermore, a majority of students (50%) expressed concerns about the clinical relevance of OSCEs. The study showed a significant associations (p < 0.05) between satisfaction levels and years of study as well as previous OSCE experience. Student focus group interviews revealed diverse perspectives on OSCE assessments. While students appreciate the helpfulness of OSCEs, concerns were raised regarding time constraints, stress, examiner training, and the perceived lack of clinical relevance. CONCLUSION: The students anticipated concerns about the clinical relevance of OSCEs, highlighting the need for a more aligned assessment approach. Diverse perspectives on OSCE assessments reveal perceived helpfulness alongside challenges such as lack of feedback, examiner training, time constraints, and mental stress.


Sujet(s)
Compétence clinique , Enseignement dentaire , Évaluation des acquis scolaires , Groupes de discussion , Satisfaction personnelle , Étudiant dentisterie , Humains , Étudiant dentisterie/psychologie , Femelle , Mâle , Enseignement dentaire/normes , Enquêtes et questionnaires , Jeune adulte , Adulte
7.
J Appl Biomater Funct Mater ; 22: 22808000241250118, 2024.
Article de Anglais | MEDLINE | ID: mdl-38706266

RÉSUMÉ

Despite the development of implant-supported prostheses, there are still patients for whom conservative treatments such as resin-bonded fixed dental prostheses (RBFDPs) are more appropriate. This study's objective was to analyze the available research on full-ceramic RBFDPs. In this study, Web of Science, MEDLINE/PubMed, Scopus, Embase, Cochrane Library, and Google Scholar databases were searched for articles published in English between 2010 and 2020. A total of 14 studies were reviewed based on the eligibility criteria. The results showed that using a cantilever design with one abutment had an advantage over two abutments. Additionally, it was proposed that preparations designed with retentive aids, such as a proximal box, groove, and pinhole, could improve RBFDP survival rates. IPS e.max ZirCAD, In-Ceram alumina, and zirconia CAD/CAM were the most commonly used framework materials. Most studies used air abrasion, salinization, or hydrofluoric acid for surface treatment. Adhesive resin cements were the most frequently used type of cement. The survival rate of In-Ceram ceramics (85.3%-94.8%) was lower than that of In-Ceram zirconia and IPS e.max ZirCAD. Debonding, followed by framework fracture, was the leading cause of failure. Following 3-10 years follow-up, the survival percentage of all-ceramic RBFDPs ranged from 76% to 100%. Although RBFDPs have demonstrated satisfactory success as a conservative treatment, long-term follow-ups and higher sample sizes in clinical research are required to gain more reliable outcomes on the clinical success rate of various RBFDP designs.


Sujet(s)
Céramiques , Humains , Céramiques/composition chimique , Céments résine/composition chimique , Porcelaine dentaire/composition chimique , Prothèse dentaire implanto-portée , Prothèse dentaire partielle fixe à liaison résine , Zirconium/composition chimique
8.
Digit Health ; 10: 20552076241253550, 2024.
Article de Anglais | MEDLINE | ID: mdl-38726220

RÉSUMÉ

Aim: The integration of advanced technologies, including three-dimensional (3D) imaging modalities and virtual simulations, has significantly influenced contemporary approaches to preoperative planning in implant dentistry. Through a meticulous analysis of relevant studies, this review synthesizes findings related to accuracy outcomes in implant placement facilitated by 3D imaging in virtual patients. Methods: A comprehensive literature search was conducted across relevant databases to identify relevant studies published to date. The inclusion criteria were studies utilizing 3D imaging techniques, virtual patients, and those focusing on the accuracy of dental implant planning and surgical placement. The selected studies were critically appraised for their methodological quality. Results: After a rigorous analysis, 21 relevant articles were included out of 3021 articles. This study demonstrates the versatility and applicability of these technologies in both in vitro and in vivo settings. Integrating Computer-Aided Design/Computer-Aided Manufacturing (CAD/CAM), cone bean computed tomography (CBCT), and advanced 3D reconstruction methodologies showcases a trend toward enhanced precision in implant planning and placement. Notably, the evaluation parameters varied, encompassing distances, discrepancies, and deviations in the implant placement. The ongoing integration of systems such as dynamic navigation systems, augmented reality, and sophisticated software platforms shows a promising trajectory for the continued refinement of virtual reality applications in dental implantology, providing valuable insights for future research and clinical implementation. Moreover, using stereolithographic surgical guides, virtual planning with CBCT data, and 3D-printed templates consistently demonstrates enhanced precision in dental implant placement compared to traditional methods. Conclusion: The synthesis of the available evidence underscores the substantial positive impact of 3D imaging techniques and virtual patients on dental implant planning and surgical placement accuracy. Utilizing these technologies contributes to a more personalized and precise approach that enhances overall treatment outcomes. Future research directions and potential refinements to the application of these technologies in clinical practice should be discussed.

9.
J Dent Educ ; 2024 May 28.
Article de Anglais | MEDLINE | ID: mdl-38807268

RÉSUMÉ

PURPOSE: Virtual reality (VR) simulations have been increasingly employed to train dental students prior to clinical practice. According to the literature, blended learning designs in the form of VR simulations can be utilized by both dental students and instructors to provide quality education. They can also save time and improve motor skills before students enter clinical stages. Therefore, this study was designed to review the importance of available VR simulators and their impact on student learning and outcomes. METHOD: The Preferred Reporting Items for Systematic Reviews and Meta-Analysis guidelines were followed to review the literature systematically, and different databases such as PubMed, ScienceDirect, Cochrane Library, Scopus, and Google Scholar were searched (up to December 2023) for relevant articles using keywords: "virtual reality," "virtual reality simulators," "virtual reality simulation," and "dental education." The Mixed Methods Appraisal Tool was used to assess the study quality. RESULTS: After a comprehensive literature search, 1477 research articles were identified, of which 16 were included in the present study. In terms of students' learning outcomes, engagement, and optimal approach, a significant improvement was observed compared to conventional training methods, specifically in their knowledge, performance, confidence, and psychomotor skills. CONCLUSION: The findings suggest that VR simulators enhance the overall learning abilities of dental students and should be regarded as an integral component of the current curriculum. However, it is important to recognize that VR simulators cannot fully substitute traditional training methods; rather, they can effectively complement them.

10.
BMC Oral Health ; 24(1): 557, 2024 May 13.
Article de Anglais | MEDLINE | ID: mdl-38735940

RÉSUMÉ

BACKGROUND: Dental resin-based composites are widely recognized for their aesthetic appeal and adhesive properties, which make them integral to modern restorative dentistry. Despite their advantages, adhesion and biomechanical performance challenges persist, necessitating innovative strategies for improvement. This study addressed the challenges associated with adhesion and biomechanical properties in dental resin-based composites by employing molecular docking and dynamics simulation. METHODS: Molecular docking assesses the binding energies and provides valuable insights into the interactions between monomers, fillers, and coupling agents. This investigation prioritizes SiO2 and TRIS, considering their consistent influence. Molecular dynamics simulations, executed with the Forcite module and COMPASS II force field, extend the analysis to the mechanical properties of dental composite complexes. The simulations encompassed energy minimization, controlled NVT and NPT ensemble simulations, and equilibration stages. Notably, the molecular dynamics simulations spanned a duration of 50 ns. RESULTS: SiO2 and TRIS consistently emerged as influential components, showcasing their versatility in promoting solid interactions. A correlation matrix underscores the significant roles of van der Waals and desolvation energies in determining the overall binding energy. Molecular dynamics simulations provide in-depth insights into the mechanical properties of dental composite complexes. HEMA-SiO2-TRIS excelled in stiffness, BisGMA-SiO2-TRIS prevailed in terms of flexural strength, and EBPADMA-SiO2-TRIS offered a balanced combination of mechanical properties. CONCLUSION: These findings provide valuable insights into optimizing dental composites tailored to diverse clinical requirements. While EBPADMA-SiO2-TRIS demonstrates distinct strengths, this study emphasizes the need for further research. Future investigations should validate the computational findings experimentally and assess the material's response to dynamic environmental factors.


Sujet(s)
Matériaux biocompatibles , Résines composites , Simulation de docking moléculaire , Simulation de dynamique moléculaire , Silice , Résines composites/composition chimique , Silice/composition chimique , Matériaux biocompatibles/composition chimique , Matériaux dentaires/composition chimique , Méthacrylates/composition chimique , Polyuréthanes/composition chimique , Poly(acides méthacryliques)/composition chimique , Polyéthylène glycols/composition chimique , Résines acryliques/composition chimique
11.
Discov Nano ; 19(1): 95, 2024 May 30.
Article de Anglais | MEDLINE | ID: mdl-38814562

RÉSUMÉ

BACKGROUND: Nanoparticles are increasingly used in dentistry for various applications, including enhancing the mechanical properties of denture base resins. This study aimed to comprehensively review and analyze the research landscape of nanoparticles and their effect on the flexural strength of denture base resins to identify key research areas and trends and to highlight the importance of collaboration between authors and institutions. METHODS: A Bibliometric Analysis was conducted using the Keywords "Nanoparticle*" AND "Denture*" OR "CAD/CAM." The literature search from the WOS database was restricted to the publication years 2011 to 2022. RESULTS: Key findings encompass an increase in research publications but a decline in citations. Saudi Arabia, China, and Iraq led this research, with specific institutions excelling. Notable journals with high impact factors were identified. Authorship patterns show variations in citation impact. Additionally, keyword analysis revealed that current research trends offer insights into influential authors and their networks. CONCLUSIONS: The analysis of nanoparticles and denture base resins reveals a dynamic and evolving landscape that emphasizes the importance of collaboration, staying current with research trends, and conducting high-quality research in this ever-evolving domain.

12.
J Oral Rehabil ; 51(7): 1250-1302, 2024 Jul.
Article de Anglais | MEDLINE | ID: mdl-38570927

RÉSUMÉ

BACKGROUND: Various medical conditions and the drugs used to treat them have been shown to impede or complicate dental implant surgery. It is crucial to carefully monitor the medical status and potential post-operative complications of patients with systemic diseases, particularly elderly patients, to minimize the risk of health complications that may arise. AIM: The purpose of this study was to review the existing evidence on the viability of dental implants in patients with systemic diseases and to provide practical recommendations to achieve the best possible results in the corresponding patient population. METHODS: The information for our study was compiled using data from PubMed, Scopus, Web of Science and Google Scholar databases and searched separately for each systemic disease included in our work until October 2023. An additional manual search was also performed to increase the search sensitivity. Only English-language publications were included and assessed according to titles, abstracts and full texts. RESULTS: In total, 6784 studies were found. After checking for duplicates and full-text availability, screening for the inclusion criteria and manually searching reference lists, 570 articles remained to be considered in this study. CONCLUSION: In treating patients with systemic conditions, the cost-benefit analysis should consider the patient's quality of life and expected lifespan. The success of dental implants depends heavily on ensuring appropriate maintenance therapy, ideal oral hygiene standards, no smoking and avoiding other risk factors. Indications and contraindications for dental implants in cases of systemic diseases are yet to be more understood; broader and hardcore research needs to be done for a guideline foundation.


Sujet(s)
Implants dentaires , Humains , Implants dentaires/effets indésirables , Qualité de vie , Pose d'implant dentaire endo-osseux/effets indésirables , Complications postopératoires/prévention et contrôle , Analyse coût-bénéfice , Facteurs de risque , Soins dentaires pour malades chroniques
13.
J Oral Biol Craniofac Res ; 14(3): 335-338, 2024.
Article de Anglais | MEDLINE | ID: mdl-38680473

RÉSUMÉ

The P2X7 receptor, a member of the P2X receptor family, plays a crucial role in various physiological processes, particularly pain perception. Its expression across immune, neuronal, and glial cells facilitates the release of pro-inflammatory molecules, thereby influencing pain development and maintenance, as evidenced by its association with pulpitis in rats. Notably, P2X receptors such as P2X3 and P2X7 are pivotal in dental pain pathways, making them promising targets for novel analgesic interventions. Leveraging graph neural networks (GNNs) presents an innovative approach to model graph data, aiding in the identification of drug targets and prediction of their efficacy, complementing advancements in genomics and proteomics for therapeutic development. In this study, 921 drug-gene interactions involving P2X receptors were accessed through https://www.probes-drugs.org/. These interactions underwent meticulous annotation, preprocessing, and subsequent utilization to train and assess GNNs. Furthermore, leveraging Cytoscape, the CytoHubba plugin, and other bioinformatics tools, gene expression networks were constructed to pinpoint hub genes within these interactions. Through analysis, SLC6A3, SLC6A2, FGF1, GRK2, and PLA2G2A were identified as central hub genes within the context of P2X receptor-mediated drug-gene interactions. Despite achieving a 65 percent accuracy rate, the GNN model demonstrated suboptimal predictive power for gene-drug interactions associated with oral pain. Hence, further refinements and enhancements are imperative to unlock its full potential in elucidating and targeting pathways underlying oral pain mechanisms.

14.
SAGE Open Med Case Rep ; 12: 2050313X241248385, 2024.
Article de Anglais | MEDLINE | ID: mdl-38680597

RÉSUMÉ

The objective of this case report was to provide a plan for aesthetic rehabilitation of a patient utilizing layered zirconia restorations to produce a homogeneous, pleasing smile. In this case, a female patient, aged 38 years, presented in dental clinic with a spaced dentition and faulty crowns that were causing functional and aesthetic concerns. She was a banker by profession and socially active. The treatment plan involved layered zirconia indirect restorations to enhance her natural teeth appearance. The aim of this case report was to propose an effective strategy for addressing her concerns, with the potential to achieve a desired aesthetic outcome. Additionally, the implementation of this treatment approach had a positive influence on self-esteem and confidence of the patient.

15.
Eur J Med Res ; 29(1): 254, 2024 Apr 24.
Article de Anglais | MEDLINE | ID: mdl-38659074

RÉSUMÉ

BACKGROUND: Yttrium-stabilized zirconia (YSZ) and alumina are the most commonly used dental esthetic crown materials. This study aimed to provide detailed information on the comparison between yttrium-stabilized zirconia (YSZ) and alumina, the two materials most often used for esthetic crowns in dentistry. METHODOLOGY: The ground-state energy of the materials was calculated using the Cambridge Serial Total Energy Package (CASTEP) code, which employs a first-principles method based on density functional theory (DFT). The electronic exchange-correlation energy was evaluated using the generalized gradient approximation (GGA) within the Perdew (Burke) Ernzerhof scheme. RESULTS: Optimization of the geometries and investigation of the optical properties, dynamic stability, band structures, refractive indices, and mechanical properties of these materials contribute to a holistic understanding of these materials. Geometric optimization of YSZ provides important insights into its dynamic stability based on observations of its crystal structure and polyhedral geometry, which show stable configurations. Alumina exhibits a distinctive charge, kinetic, and potential (CKP) geometry, which contributes to its interesting structural framework and molecular-level stability. The optical properties of alumina were evaluated using pseudo-atomic computations, demonstrating its responsiveness to external stimuli. The refractive indices, reflectance, and dielectric functions indicate that the transmission of light by alumina depends on numerous factors that are essential for the optical performance of alumina as a material for esthetic crowns. The band structures of both the materials were explored, and the band gap of alumina was determined to be 5.853 eV. In addition, the band structure describes electronic transitions that influence the conductivity and optical properties of a material. The stability of alumina can be deduced from its bandgap, an essential property that determines its use as a dental material. Refractive indices are vital optical properties of esthetic crown materials. Therefore, the ability to understand their refractive-index graphs explains their transparency and color distortion through how the material responds to light..The regulated absorption characteristics exhibited by YSZ render it a highly attractive option for the development of esthetic crowns, as it guarantees minimal color distortion. CONCLUSION: The acceptability of materials for esthetic crowns is strongly determined by mechanical properties such as elastic stiffness constants, Young's modulus, and shear modulus. YSZ is a highly durable material for dental applications, owing to its superior mechanical strength.


Sujet(s)
Oxyde d'aluminium , Couronnes , Yttrium , Zirconium , Yttrium/composition chimique , Zirconium/composition chimique , Oxyde d'aluminium/composition chimique , Humains , Théorie quantique
16.
SAGE Open Med Case Rep ; 12: 2050313X241241191, 2024.
Article de Anglais | MEDLINE | ID: mdl-38559405

RÉSUMÉ

New surgical techniques using narrow, tilted implants positioned through a magneto-dynamic tool in guided surgery for a Toronto restoration. A 69-year-old woman wanted fixed rehabilitation to replace her removable complete dentures. A cone-beam computed tomography showed significant bone resorption in both the maxillary and mandibular regions. The plan was to load the entire upper arch with six implants immediately, while removable partial dentures were recommended for the lower jaw. The guided surgery project was aligned with the new dentures, and the laboratory created a printed cast with dental implant analogues in planned positions. A metal-reinforced denture was constructed, and surgery was performed to place six narrow implants using the magneto-dynamic instrument. The denture was directly screwed onto multi-unit abutments. Final rehabilitation was completed after 6 months. Narrow implants can be a good option for fixed, full-arch rehabilitations. Further research is needed to confirm these findings on a larger scale.

17.
BMC Oral Health ; 24(1): 458, 2024 Apr 15.
Article de Anglais | MEDLINE | ID: mdl-38622548

RÉSUMÉ

BACKGROUND: Various methods, chemical and physical, disinfect dental impressions. Common chemicals include 1% Sodium Hypochlorite and 2% glutaraldehyde, while UV radiation is a prevalent physical method. Few studies compare their effects on dimensional stability in polyether impressions. This study aims to assess such stability using different disinfection methods. Therefore, this study was planned to evaluate the dimensional stability of polyether impression material using different disinfection methods. METHODS: This in vitro study compared the effects of chemical disinfectants (1% Sodium Hypochlorite and 2% glutaraldehyde) and UV irradiation on the dimensional stability of polyether impression material. Groups A, B, C, and D, each with ten samples (N = 10), were studied. Group A was untreated (control). Group B was treated with 2% glutaraldehyde for 20 min, Group C with 1% Sodium Hypochlorite for 20 min, and Group D with UV rays for 20 min. A pilot milling machine drill was used to make four parallel holes labeled A, B, C, and D in the anterior and premolar regions from right to left. After sequential drilling, four implant analogs were positioned using a surveyor for accuracy. Ten open-tray polyether impressions were made and treated as described in the groups, followed by pouring the corresponding casts. Distortion values for each disinfection method were measured using a coordinate measuring machine capable of recording on the X- and Y-axes. RESULTS: A comprehensive analysis was conducted using the one-way ANOVA test for distinct groups labeled A, B, C, and D, revealing significant differences in the mean distances for X1, X2, X4, X5, and X6 among the groups, with p-values ranging from 0.001 to 0.000. However, no significant differences were observed in X3. Notably, mean distances for the Y variables exhibited substantial differences among the groups, emphasizing parameter variations, with p-values ranging from 0.000 to 0.033. The results compared the four groups using the one-way ANOVA test, revealing statistically significant distance differences for most X and Y variables, except for X3 and Y4. Similarly, post-hoc Tukey's tests provided specific pairwise comparisons, underlining the distinctions between group C and the others in the mean and deviation distances for various variables on both the X- and Y-axes. CONCLUSIONS: This study found that disinfection with 1% sodium hypochlorite or UV rays for 20 min maintained dimensional stability in polyether impressions.


Sujet(s)
Désinfectants , Désinfection , Humains , Désinfection/méthodes , Glutaraldéhyde , Hypochlorite de sodium , Matériaux empreinte dentaire , Technique de prise d'empreinte
18.
BMC Oral Health ; 24(1): 366, 2024 Mar 21.
Article de Anglais | MEDLINE | ID: mdl-38515128

RÉSUMÉ

BACKGROUND: The success of implants in the socket shield technique relies on stress experienced by root fragments within the socket. Although there is no consensus on optimal root fragment thickness, varying thicknesses and dynamic implant placement induce stress in various directions and degrees. This study aimed to assess biomechanical response and stress distribution across different root fragment thicknesses in the socket shield procedure. METHODS: This in vitro study was conducted to assess and compare the stress distribution on residual root structures of varying thicknesses positioned within the labial aspect of the maxillary incisor socket during immediate implant placement of standard dimensions. The procedure involved applying an insertional torque of 40 Ncm, and the analysis was conducted using finite element analysis software. RESULTS: Utilizing the Numerical Technique with Abaqus software for explicit dynamics, von Mises stress and principal strain were analyzed on the root structure and bone under nonlinear contact conditions during implant torque application. For Model A, a loading torque of 40 Ncm was applied vertically on the implant, along with a horizontal force of 20 N on the root structure and bone. Results indicated maximum stress of 12.68 MPa on the root structure with a thickness of 0.5 mm and 5.61 MPa on the bone, with principal strains of 6.82E-03 and 4.10E-03, respectively. In Model B, with a root structure thickness of 1.0 mm, the maximum stress increased to 19.70 MPa, while the bone stress rose to 9.51 MPa, with principal strains of 1.03E-02 and 6.09E-03. Model C, with a root structure thickness of 1.5 mm, exhibited a maximum stress of 21.58 MPa on the root and 10.12 MPa on the bone, with principal strains of 1.16E-02 and 6.10E-03. Lastly, in Model D, with a root structure thickness of 2.0 mm, the maximum stress on the root structure and bone escalated to 28.74 MPa and 11.38 MPa, respectively, with principal strains of 1.55E-02 and 8.31E-03. CONCLUSIONS: As the thickness of the shield increases (ranging from 0.5 to 2 mm) in socket shield procedures with immediate implant placement, both stress on the root fragment and bone and principal micro-strain escalate. However, employing a shield thickness within the range of 0.5 to 2 mm does not lead to any adverse stress generation on the residual root fragment. However, for enhanced safety, it is recommended to restrict the maximum diameter and extension of the root fragment to 1.5 mm when considering implant sizes and socket diameter for the socket shield technique.


Sujet(s)
Implants dentaires unitaires , Implants dentaires , Pose immédiate d'implant dentaire , Humains , Analyse des éléments finis , Alvéole dentaire/chirurgie , Analyse du stress dentaire
19.
PLoS One ; 19(3): e0300157, 2024.
Article de Anglais | MEDLINE | ID: mdl-38483856

RÉSUMÉ

OBJECTIVE: The current body of research on utilizing botulinum toxin (BTX) to manage temporomandibular disorders (TMDs) has not yet yielded definitive conclusions. The primary objective of this study was to determine the effectiveness of BTX in pain reduction for TMDs compared to placebo and other treatments. The secondary outcomes evaluated were adverse events, maximum mouth opening, bruxism events, and maximum occlusal force. MATERIALS AND METHODS: A literature search was performed on PubMed, Dimension Publication, Scopus, and Google Scholar. The RoB 2 tool was used for quality assessment. The mean differences in pain scores were estimated to measure the effect of BTX on pain reduction. For adverse events, the risk ratio for the incidence of side effects was calculated. RESULTS: Two hundred and sixty non-duplicate articles were identified; however, only 14 RCTS were included in this review. The total study population included 395 patients. The overall risk of bias showed a low to moderate quality of evidence. Results from 6 studies were reported only narratively; four studies were used for meta-analysis on pain reduction, and five were used for meta-analysis on adverse events. The control used in the meta-analysis was placebo injections. Results of the meta-analysis for pain reduction were statistically insignificant for the BTX group with mean differences at MD = -1.71 (95% CI, -2.87 to -0.5) at one month, -1.53 (95% CI, -2.80 to -0.27) at three months, and -1.33 (95% CI, -2.74 to 0.77) at six months. This showed that BTX treatment was not significantly better than placebo for a reduction in pain scores at 1, 3, and 6 months. Regarding safety, the placebo group showed a relative risk of 1.34 (95%CI, 0.48-6.78) and 1.17 (95%CI, 0.54-3.88) at 1 and 3 months respectively. However, the risks were not statistically significant. There was also no difference in the effectiveness of BTX compared to placebo and other treatments for maximum mouth opening, bruxism events, and maximum occlusal force. CONCLUSION: BTX was not associated with better outcomes in terms of pain reduction, adverse events, maximum mouth opening, bruxism events, and maximum occlusal force. More high-quality RCTs are needed to better understand this topic.


Sujet(s)
Toxines botuliniques de type A , Bruxisme , Troubles de l'articulation temporomandibulaire , Humains , Toxines botuliniques de type A/effets indésirables , Bruxisme/traitement médicamenteux , Douleur/traitement médicamenteux , Troubles de l'articulation temporomandibulaire/traitement médicamenteux , Force occlusale
20.
BMC Oral Health ; 24(1): 335, 2024 Mar 14.
Article de Anglais | MEDLINE | ID: mdl-38486235

RÉSUMÉ

BACKGROUND: Several efforts have been made to improve mechanical and biological properties of calcium silicate-based cements through changes in chemical composition of the materials. This study aimed to investigate the physical (including setting time and compressive strength) and chemical (including calcium ion release, pH level) properties as well as changes in cytotoxicity of mineral trioxide aggregate (MTA) after the addition of 3 substances including CaCl2, Na2HPO4, and propylene glycol (PG). METHODS: The systematic review was conducted in accordance with Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA). Electronic searches were performed on PubMed, Embase, and Scopus databases, spanning from 1993 to October 2023 in addition to manual searches. Relevant laboratory studies were included. The quality of the included studies was assessed using modified ARRIVE criteria. Meta-analyses were performed by RevMan statistical software. RESULTS: From the total of 267 studies, 24 articles were included in this review. The results of the meta-analysis indicated that addition of PG increased final setting time and Ca2+ ion release. Addition of Na2HPO4 did not change pH and cytotoxicity but reduced the final setting time. Incorporation of 5% CaCl2 reduced the setting time but did not alter the cytotoxicity of the cement. However, addition of 10% CaCl2 reduced cell viability, setting time, and compressive strength. CONCLUSION: Inclusion of 2.5% wt. Na2HPO4 and 5% CaCl2 in MTA can be advisable for enhancing the physical, chemical, and cytotoxic characteristics of the admixture. Conversely, caution is advised against incorporating elevated concentrations of PG due to its retarding effect. TRIAL REGISTRATION: PROSPERO registration number: CRD42021253707.


Sujet(s)
Composés de l'aluminium , Composés du calcium , Oxydes , Silicates , Composés de l'aluminium/toxicité , Composés de l'aluminium/composition chimique , Chlorure de calcium/pharmacologie , Ciments dentaires/toxicité , Ciments dentaires/composition chimique , Association médicamenteuse , Oxydes/toxicité , Oxydes/composition chimique , Propylène glycol/composition chimique
SÉLECTION CITATIONS
DÉTAIL DE RECHERCHE
...