Your browser doesn't support javascript.
loading
Montrer: 20 | 50 | 100
Résultats 1 - 2 de 2
Filtrer
Plus de filtres










Base de données
Gamme d'année
1.
Orthopedics ; 47(2): e85-e89, 2024.
Article de Anglais | MEDLINE | ID: mdl-37757748

RÉSUMÉ

Advances in artificial intelligence and machine learning models, like Chat Generative Pre-trained Transformer (ChatGPT), have occurred at a remarkably fast rate. OpenAI released its newest model of ChatGPT, GPT-4, in March 2023. It offers a wide range of medical applications. The model has demonstrated notable proficiency on many medical board examinations. This study sought to assess GPT-4's performance on the Orthopaedic In-Training Examination (OITE) used to prepare residents for the American Board of Orthopaedic Surgery (ABOS) Part I Examination. The data gathered from GPT-4's performance were additionally compared with the data of the previous iteration of ChatGPT, GPT-3.5, which was released 4 months before GPT-4. GPT-4 correctly answered 251 of the 396 attempted questions (63.4%), whereas GPT-3.5 correctly answered 46.3% of 410 attempted questions. GPT-4 was significantly more accurate than GPT-3.5 on orthopedic board-style questions (P<.00001). GPT-4's performance is most comparable to that of an average third-year orthopedic surgery resident, while GPT-3.5 performed below an average orthopedic intern. GPT-4's overall accuracy was just below the approximate threshold that indicates a likely pass on the ABOS Part I Examination. Our results demonstrate significant improvements in OpenAI's newest model, GPT-4. Future studies should assess potential clinical applications as AI models continue to be trained on larger data sets and offer more capabilities. [Orthopedics. 2024;47(2):e85-e89.].


Sujet(s)
Internat et résidence , Procédures orthopédiques , Orthopédie , Humains , Orthopédie/enseignement et éducation , Intelligence artificielle , Évaluation des acquis scolaires , Compétence clinique
2.
Allergy ; 79(2): 445-455, 2024 Feb.
Article de Anglais | MEDLINE | ID: mdl-37916710

RÉSUMÉ

BACKGROUND: Conventional basophil activation tests (BATs) measure basophil activation by the increased expression of CD63. Previously, fluorophore-labeled avidin, a positively-charged molecule, was found to bind to activated basophils, which tend to expose negatively charged granule constituents during degranulation. This study further compares avidin versus CD63 as basophil activation biomarkers in classifying peanut allergy. METHODS: Seventy subjects with either a peanut allergy (N = 47), a food allergy other than peanut (N = 6), or no food allergy (N = 17) were evaluated. We conducted BATs in response to seven peanut extract (PE) concentrations (0.01-10,000 ng/mL) and four control conditions (no stimulant, anti-IgE, fMLP (N-formylmethionine-leucyl-phenylalanine), and anti-FcεRI). We measured avidin binding and CD63 expression on basophils with flow cytometry. We evaluated logistic regression and XGBoost models for peanut allergy classification and feature identification. RESULTS: Avidin binding was correlated with CD63 expression. Both markers discriminated between subjects with and without a peanut allergy. Although small by percentage, an avidin+ /CD63- cell subset was found in all allergic subjects tested, indicating that the combination of avidin and CD63 could allow a more comprehensive identification of activated basophils. Indeed, we obtained the best classification accuracy (97.8% sensitivity, 96.7% specificity) by combining avidin and CD63 across seven PE doses. Similar accuracy was obtained by combining PE dose of 10,000 ng/mL for avidin and PE doses of 10 and 100 ng/mL for CD63. CONCLUSIONS: Avidin and CD63 are reliable BAT activation markers associated with degranulation. Their combination enhances the identification of activated basophils and improves the classification accuracy of peanut allergy.


Sujet(s)
Test de dégranulation des basophiles , Hypersensibilité aux arachides , Humains , Hypersensibilité aux arachides/diagnostic , Hypersensibilité aux arachides/métabolisme , Avidine/métabolisme , Immunoglobuline E/métabolisme , Granulocytes basophiles/métabolisme , Cytométrie en flux , Arachis , Antigène CD63/métabolisme
SÉLECTION CITATIONS
DÉTAIL DE RECHERCHE
...