Your browser doesn't support javascript.
loading
Montrer: 20 | 50 | 100
Résultats 1 - 20 de 25
Filtrer
1.
Phys Rev Lett ; 96(18): 181801, 2006 May 12.
Article de Anglais | MEDLINE | ID: mdl-16712358

RÉSUMÉ

We performed an improved search for nu(mu) --> nu(e) oscillation with the KEK to Kamioka (K2K) long-baseline neutrino oscillation experiment, using the full data sample of 9.2 x 10(19) protons on target. No evidence for a nu(e) appearance signal was found, and we set bounds on the nu(mu) --> nu(e) oscillation parameters. At Deltam(2)=2.8 x 10(-3) eV(2), the best-fit value of the K2Knu(mu) disappearance analysis, we set an upper limit of sin(2)2theta(mue) < 0.13 at a 90% confidence level.

2.
Phys Rev Lett ; 95(25): 252301, 2005 Dec 16.
Article de Anglais | MEDLINE | ID: mdl-16384451

RÉSUMÉ

We report the result from a search for charged-current coherent pion production induced by muon neutrinos with a mean energy of 1.3 GeV. The data are collected with a fully active scintillator detector in the K2K long-baseline neutrino oscillation experiment. No evidence for coherent pion production is observed, and an upper limit of is set on the cross section ratio of coherent pion production to the total charged-current interaction at 90% confidence level. This is the first experimental limit for coherent charged pion production in the energy region of a few GeV.

3.
Phys Rev Lett ; 94(8): 081802, 2005 Mar 04.
Article de Anglais | MEDLINE | ID: mdl-15783876

RÉSUMÉ

We present results for nu(mu) oscillation in the KEK to Kamioka (K2K) long-baseline neutrino oscillation experiment. K2K uses an accelerator-produced nu(mu) beam with a mean energy of 1.3 GeV directed at the Super-Kamiokande detector. We observed the energy-dependent disappearance of nu(mu), which we presume have oscillated to nu(tau). The probability that we would observe these results if there is no neutrino oscillation is 0.0050% (4.0 sigma).

4.
Phys Rev Lett ; 93(10): 101801, 2004 Sep 03.
Article de Anglais | MEDLINE | ID: mdl-15447395

RÉSUMÉ

Muon neutrino disappearance probability as a function of neutrino flight length L over neutrino energy E was studied. A dip in the L/E distribution was observed in the data, as predicted from the sinusoidal flavor transition probability of neutrino oscillation. The observed L/E distribution constrained nu(micro)<-->nu(tau) neutrino oscillation parameters; 1.9x10(-3)0.90 at 90% confidence level.

5.
Kyobu Geka ; 56(11): 973-6, 2003 Oct.
Article de Japonais | MEDLINE | ID: mdl-14579703

RÉSUMÉ

We reported a successful case of emergent total arch replacement for a nonagenarian with acute Stanford A aortic dissection. A 92-year-old woman complained of general fatigue, with hypotension. Echocardiography showed moderate pericardial effusion and aortic regurgitation. Computed tomography (CT) scan showed widely extended aortic dissection from the ascending aorta to descending thoracic aorta, and cardiac tamponade. An emergent total arch replacement was performed under hypothermic selective cerebral perfusion with bladder temperature of 22.5 degrees C. Although she suffered from pneumothorax, renal insufficiency and gastrointestinal (GI) bleeding postoperatively, she tolerated the operation and complications, well. She is now leading a good life with the same level of activities of daily living (ADL) as preoperative one.


Sujet(s)
Anévrysme de l'aorte thoracique/chirurgie , /chirurgie , Implantation de prothèses vasculaires , Activités de la vie quotidienne , Sujet âgé , Sujet âgé de 80 ans ou plus , Aorte/chirurgie , Aorte thoracique/chirurgie , Femelle , Humains
7.
Ann Thorac Surg ; 68(3): 864-9, 1999 Sep.
Article de Anglais | MEDLINE | ID: mdl-10509975

RÉSUMÉ

BACKGROUND: Optimal conditions for deep hypothermic perfusion and protective brain blood flow remain unclear. METHODS: Dogs (n = 52) underwent 120 minutes of cardiopulmonary bypass at 20 degrees C with perfusion flow rates of 2.5, 5, 10, 20, 40, and 100 mL x kg(-1) x min(-1). We examined the effect of the various flow rates and different perfusion pressures on brain blood flow, metabolism, and intracellular pH. RESULTS: The brain was ischemic and acidotic when the perfusion flow rate was less than 5 mL kg(-1) x min(-1) and pressure was less than 10 mm Hg. When perfusion pressure was higher than 10 mm Hg, cerebral cortex blood flow was more than 9 mL x 100 g(-1) x min(-1) and intracellular pH, higher than 6.95. The cerebral metabolic rate for oxygen decreased at a flow rate of 2.5 mL x kg(-1) min(-1). The cerebral metabolic ratio of glucose to oxygen and the cerebral vascular resistance were lowest when perfusion pressure was 10 to 30 mm Hg. Full-flow (100 mL x kg(-1) x min(-1)) perfusion caused paradoxical brain acidosis; a flow of 40 mL x kg(-1) x min(-1) provided the best results. CONCLUSIONS: Both extremely low-flow perfusion and excessive perfusion cause brain acidosis. Low-flow perfusion at a pressure of 20 mm Hg provides cerebral vasorelaxation and aerobic metabolism during operations at 20 degrees C.


Sujet(s)
Pontage cardiopulmonaire , Circulation cérébrovasculaire , Hypothermie provoquée , Animaux , Vitesse du flux sanguin , Encéphale/métabolisme , Cortex cérébral/vascularisation , Chiens , Glucose/métabolisme , Concentration en ions d'hydrogène , Consommation d'oxygène , Résistance vasculaire
8.
Acta Radiol ; 40(5): 545-51, 1999 Sep.
Article de Anglais | MEDLINE | ID: mdl-10485246

RÉSUMÉ

PURPOSE: To assess the efficacy of the Spring filter during interventional treatment of deep venous thrombosis in vivo. MATERIAL AND METHODS: A model of inferior vena cava thrombosis was used. Part I: The thrombus was treated by the pulse-spray technique (PT) (urokinase 250,000 IU; n=7) or a rotatory basket catheter, Thrombolizer (MT) (activated with compressed air at 7 atm; n=5). Part II: Following placement of a Spring filter, the animal underwent PT (n=5) or MT (n=5). Based on the results of part I, the treatment protocol was modified (PT, urokinase 500,000 IU; MT, compressed air at 8 atm). Embolus volumes trapped by the filter and found in the lungs were calculated and the filtering efficacy quantified. RESULTS: Part I: Pulmonary emboli (1 to 4 mm in diameter) were observed in 3 animals in the PT group and 1 animal in the MT group, respectively. Median reduction in thrombus volume was 21% and 4% by PT and MT, respectively. Part II: In the PT group, 58% and 100% of the total embolus load was trapped in 2 animals, while the filter failed to trap emboli (1 to 1.5 mm in diameter) in 1 animal. In the remaining 2 animals, no embolus was found trapped by the filter or in the lungs. In the MT group, 55 97% (median 83%) of the embolus load was trapped. Emboli found in the lungs did not exceed 4 mm in diameter. CONCLUSION: Preceding interventional treatment of venous thrombosis with placement of the Spring filter reduced the embolic burden on the lungs.


Sujet(s)
Embolie pulmonaire/prévention et contrôle , Thrombectomie/méthodes , Traitement thrombolytique/méthodes , Filtres caves , Veine cave inférieure , Thrombose veineuse/thérapie , Angiographie , Animaux , Modèles animaux de maladie humaine , Femelle , Fibrinolytiques/administration et posologie , Injections veineuses , Embolie pulmonaire/imagerie diagnostique , Embolie pulmonaire/étiologie , Suidae , Résultat thérapeutique , Thrombose veineuse/complications , Thrombose veineuse/imagerie diagnostique
9.
Acad Radiol ; 6(6): 343-51, 1999 Jun.
Article de Anglais | MEDLINE | ID: mdl-10376065

RÉSUMÉ

RATIONALE AND OBJECTIVES: The authors performed this study to compare the in vivo efficacies of the temporary venous spring filter and the RF02 filter in an animal model. MATERIALS AND METHODS: Either the spring filter or the RF02 filter was placed in the inferior vena cava of 10 pigs each, and two clots (5 x 20 mm) were funneled into the filters at 1-hour intervals. The second clots were funneled without removing the first clots captured by the filters. Clot-trapping ability, caval occlusion associated with the clot-trapping procedure, arterial blood gas concentrations, and changes in arterial and iliac venous pressures were evaluated. RESULTS: Placement of the RF02 filter caused elevation of iliac venous pressure with a maximum of 2.2 mm Hg (median) (n = 13, P = .003). Placement of the spring filter parallel to venous flow enabled capture of 90% (nine of 10) and 100% (six of six) of the first and second clots, respectively. The RF02 filter captured clots consistently. The difference between filters was not statistically significant. Both filters equally contributed to elevation of iliac venous pressure (median, 9.3 and 7.2 mm Hg [n = 9] with the spring filter and RF02 filter, respectively). Caval occlusion occurred in 17% (one of six) and 67% (six of nine) of animals after two clots were trapped in the spring filter and RF02 filter, respectively (P = .06). Other parameters were not influenced by the clot-trapping procedure. CONCLUSION: Although a larger version should be developed and better stability of the filter is needed, the spring filter proved to be an efficient filtering device and had a lower rate of caval occlusion compared with the RF02 filter.


Sujet(s)
Filtres caves , Animaux , Loi du khi-deux , Conception d'appareillage , Hémodynamique , Projets pilotes , Embolie pulmonaire/physiopathologie , Embolie pulmonaire/prévention et contrôle , Radiographie , Radiologie interventionnelle , Statistique non paramétrique , Suidae , Veine cave inférieure/imagerie diagnostique
10.
Kyobu Geka ; 52(3): 218-23, 1999 Mar.
Article de Japonais | MEDLINE | ID: mdl-10097549

RÉSUMÉ

Between 1978 and 1997, 9 patients developed poststernotomy mediastinitis after coronary artery bypass grafting. Four of these patients (group A) were treated with open drainage and mediastinal irrigation or omental transfer. The other 5 patients (group B) were treated with primary wound closure by the technique of muscle flap mobilization. The purpose of this study was to compare the surgical results and graft patency of both groups. The hospital mortality of group A was 100 per cent. All patients in group B survived for 35 months of the mean postoperative periods without complaints. Postoperative coronary angiography revealed the complete graft patency in group B. We conclude that muscle flap mobilization may be a superior measure for the patient survival and graft patency as the treatment of mediastinitis after coronary artery bypass grafting.


Sujet(s)
Pontage aortocoronarien , Médiastinite/chirurgie , Omentum/transplantation , Complications postopératoires/chirurgie , Lambeaux chirurgicaux , Degré de perméabilité vasculaire , Sujet âgé , Drainage , Femelle , Humains , Mâle , Adulte d'âge moyen , Résultat thérapeutique
11.
Acad Radiol ; 5(9): 620-5, 1998 Sep.
Article de Anglais | MEDLINE | ID: mdl-9750891

RÉSUMÉ

RATIONALE AND OBJECTIVES: The authors compared in vitro function of a temporary venous spring filter with that of a temporary RF02 filter and a permanent Greenfield filter. MATERIALS AND METHODS: All three types of filters were placed in thin polyethylene tubes (diameters, 10.0-18.0 mm). Physiologic saline was substituted for flowing blood, and blood clots of three sizes (6 x 10 mm, 6 x 20 mm, 9 x 20 mm) were funneled to the filters. Clot-trapping ability of each filter and elevation of intraluminal pressure after clot trapping were assessed for each tube size. RESULTS: No statistically significant elevation in intraluminal pressure was detected immediately after placement of any filter. The clot-trapping ability of the spring filter and of Greenfield filter were slightly lower than that of the RF02 filter, but the differences were not statistically significant. After filters had trapped large clots, a high pressure gradient was detected in the 10.0-mm tube for all filters. The spring filter was associated with a higher pressure than the other filters in the 12.0-mm tube (P < .05). CONCLUSION: In vitro function of the spring filter was satisfactory in comparison with that of the RF02 filter and the Greenfield filter. For efficient filtering in the inferior vena cava, development of a larger version of the filter may be necessary.


Sujet(s)
Filtres caves , Conception d'appareillage , Techniques in vitro , Maquettes de structure , Embolie pulmonaire/prévention et contrôle
12.
Acad Radiol ; 4(7): 513-8, 1997 Jul.
Article de Anglais | MEDLINE | ID: mdl-9232172

RÉSUMÉ

RATIONALE AND OBJECTIVES: The authors performed an in vitro study to evaluate a temporary venous spring filter that can extend vessels of a wide range of diameters to a slit-shaped canal. MATERIALS AND METHODS: Filters were placed in thin polyethylene tubes or in porcine inferior vena cava specimens (diameter, 10.0-16.0 mm). Physiologic saline was substituted for blood flow, and blood clots of three sizes (6 x 10, 6 x 20, and 9 x 20 mm) were funneled to the filter. Clot-trapping ability was assessed by the degree of luminal extension. RESULTS: When the luminal extension was increased from 2.6r to 2.8r (where r is the original radius of the vein models), clot-trapping ability increased significantly (61.1%-87.5% in polyethylene tubes and 15.8%-77.5% in venous specimens, P < .001). When the luminal extension was increased to 3.0r, more than 90% of the clots were trapped in all tubes. After trapping the small, medium, and large clots, mean intraluminal pressure elevation was 1.0, 1.0, and 17.0 cm of saline, respectively. CONCLUSION: Despite its simple design, the spring filter proved to be an efficient filtering device.


Sujet(s)
Filtres caves , Animaux , Conception d'appareillage , Humains , Modèles cardiovasculaires , Embolie pulmonaire/prévention et contrôle , Suidae
13.
Nihon Rinsho ; 55(7): 1726-30, 1997 Jul.
Article de Japonais | MEDLINE | ID: mdl-9233016

RÉSUMÉ

The mean transit time (MTT), cerebral blood flow (CBF) and cerebral blood volume (CBV) using echo planar imaging (EPI) in 22 aged volunteers were measured based on moment analysis and gamma variate method. The first peak of signal intensity curve (p delta R2.) and the area under the curve after the first peak (AUC) were calculated according to the height over area method, as a convenient quantification. Then, MTT, CBF, and CBV were compared with AUC/p delta R2, p delta R2, and AUC, respectively. There was a good correlation between each other parameter (r = 0.67 - 0.92, every p < 0.001). The slow upward slope and the low peak height, however, caused a larger error between each other parameter.


Sujet(s)
Encéphale/anatomopathologie , Circulation cérébrovasculaire , Imagerie échoplanaire/méthodes , Vitesse du flux sanguin , Volume sanguin , Femelle , Humains , Mâle , Adulte d'âge moyen
14.
Nihon Igaku Hoshasen Gakkai Zasshi ; 57(3): 89-93, 1997 Feb.
Article de Japonais | MEDLINE | ID: mdl-9077088

RÉSUMÉ

Drug smuggling by intra-abdominal concealment, so called "body packing," has recently increased, even in Japan. Because of fatal drug intoxication and other adverse side effects, it is important to make a radiological diagnosis of body packers as soon as possible. A retrospective analysis of the images of plain abdominal radiography, computed tomography (CT) and ultrasound (US) was performed in twenty-three body packers to evaluate the imaging characteristics of three drugs (cannabis, cocaine and heroin). Cannabis (16 patients) and cocaine (5 patients) packages were demonstrated as well-demarcated rectangular-shaped high-density shadows surrounded by gas halo ("double condom sign") in abdominal plain radiographs and CT. Heroin packages (2 patients) were demonstrated as obscure shadows and were difficult to identify on plain radiographs, because they resembled stool masses. US was performed in one cannabis patient because of the refusal of radiological examination, and packages were demonstrated as round echogenic structures with dorsal echo extinctions. In conclusion, abdominal plain radiography, CT and US represent valuable diagnostic modalities in the assessment of body packers.


Sujet(s)
Abdomen/imagerie diagnostique , Crime , Contrôle des médicaments et des stupéfiants/législation et jurisprudence , Corps étrangers/diagnostic , Radiographie abdominale , Adulte , Cannabis , Cocaïne , Emballage de médicament , Femelle , Héroïne , Humains , Mâle , Adulte d'âge moyen , Études rétrospectives , Tomodensitométrie , Voyage , Échographie
15.
Eur Radiol ; 7(3): 333-4, 1997.
Article de Anglais | MEDLINE | ID: mdl-9087352

RÉSUMÉ

Review of the literature shows no reports of vascular malformation of the gallbladder. Herein we report an unusual case of arteriovenous malformation of the gallbladder in a patient with hepatocellular carcinoma. The gallbladder lesion was found incidentally during abdominal angiography for the carcinoma. The angiographic features were specific, comprising dilated and tortuous feeding cystic arteries, a racemose vascular network, and early-filling cystic veins.


Sujet(s)
Malformations artérioveineuses/imagerie diagnostique , Vésicule biliaire/vascularisation , Adulte , Angiographie , Malformations artérioveineuses/complications , Carcinome hépatocellulaire/complications , Humains , Tumeurs du foie/complications , Mâle
16.
J Vasc Interv Radiol ; 7(3): 395-400, 1996.
Article de Anglais | MEDLINE | ID: mdl-8761821

RÉSUMÉ

PURPOSE: To establish a new animal model of deep venous thrombosis. MATERIALS AND METHODS: Fifteen young pigs underwent temporary interruption of the inferior vena cava (IVC) below the entry of the right renal vein by means of either a silicone band (surgical technique, n = 6) or an intraluminal balloon catheter (endovascular technique, n = 9), followed by injection of absolute ethanol. Lumbar veins within 3 cm below the obstruction were ligated or occluded interventionally. The iatrogenic caval obstruction was relieved after 2 days. RESULTS: Procedure-related mortality was 33% (n = 2) and 11% (n = 1) for the surgical and endovascular groups, respectively. An adherent, occlusive thrombus was found in all four of the remaining surgically treated animals and in six of eight animals treated percutaneously. The IVC remained patent in two animals in whom balloon migration occurred. Severe caval stenosis invariably occurred after surgical banding. CONCLUSION: IVC thrombi suitable for the study of various recanalization therapies can be reliably created with this pig model.


Sujet(s)
Modèles animaux de maladie humaine , Thrombophlébite/thérapie , Angioplastie par ballonnet/instrumentation , Animaux , Femelle , Suidae , Veine cave inférieure/anatomopathologie
17.
Scand J Gastroenterol ; 31(2): 140-6, 1996 Feb.
Article de Anglais | MEDLINE | ID: mdl-8658036

RÉSUMÉ

BACKGROUND: Non-ionic, water-soluble radiographic contrast media have been suggested as intestinal permeability probes. We studied the permeability of the isosmolar contrast medium iodixanol and 51Cr-labeled ethylenediaminetetraacetic acid (EDTA) from the non-perforated colon after induction of colonic inflammation. METHODS: Colonic inflammation and ulcerations were induced by luminal colonic instillation of trinitrobenzenesulfonic acid, dissolved in 40% ethanol. Controls received saline. Fourteen days later iodixanol, 320 mg I/ml, and 51Cr-EDTA were given as an enema. Urine was collected for the subsequent 6 h and subjected to high-performance liquid chromatography and gamma activity counting. RESULTS: Urinary recovery of iodixanol and 51Cr-EDTA increased gradually with severity of the colonic inflammation. The correlation between iodixanol and 51Cr-EDTA recovery was strong (corr.coeff = 0.97). CONCLUSIONS: Iodixanol shows as good properties as 51Cr-EDTA when used as intestinal permeability probe in the inflamed and ulcerated rat colon. Use of the radiopaque properties of iodixanol enable intestinal probe exposure registration by film or fluoroscopy.


Sujet(s)
Perméabilité des membranes cellulaires/physiologie , Colite/physiopathologie , Extravasation de produits diagnostiques ou thérapeutiques/physiopathologie , Absorption intestinale/physiologie , Animaux , Radio-isotopes du chrome/pharmacocinétique , Colite/induit chimiquement , Produits de contraste/pharmacocinétique , Acide édétique/pharmacocinétique , Mâle , Rats , Rat Wistar , Acides triiodo-benzoïques/pharmacocinétique , Acide 2,4,6-trinitro-benzènesulfonique/toxicité
18.
Nihon Igaku Hoshasen Gakkai Zasshi ; 56(1): 66-7, 1996 Jan.
Article de Japonais | MEDLINE | ID: mdl-8857103

RÉSUMÉ

Immediately after pelvic contrast MRA, subtraction MRA with additional administration of contrast agent was performed for evaluation of the femoropopliteal artery. Mask images were taken with three- dimensional spoiled GRASS (24/6.9/40 degrees), followed by contrast images with 7.5 - 10 ml of Gd-DTPA. The subtracted images provided excellent depiction of the arteries without the disruption of overlapping from the venous system or surrounding tissues. Seven lesions of arterial occlusion or stenosis were pointed out by subtraction MRA in the nine lesions confirmed with IADSA. Subtraction MRA is feasible for long segment imaging of the lower extremities with Gd-DTPA.


Sujet(s)
Angiographie de soustraction digitale , Jambe/vascularisation , Angiographie par résonance magnétique/méthodes , Adulte , Sujet âgé , Produits de contraste , Femelle , Acide gadopentétique , Humains , Mâle , Adulte d'âge moyen , Composés organométalliques , Acide pentétique/analogues et dérivés
19.
J Vasc Interv Radiol ; 6(6): 887-93, 1995.
Article de Anglais | MEDLINE | ID: mdl-8850665

RÉSUMÉ

PURPOSE: To establish the influence of number of emboli on the trapping ability of vena cava filters in vitro. MATERIALS AND METHODS: Three filters, the titanium Greenfield, Vena Tech-LGM, and Günther Tulip retrievable, were studied with use of 20- or 26-mm-diameter tubes to simulate the inferior vena cava. In the first protocol, five small (4 x 20-mm) or medium (6 x 10-mm) emboli were delivered in sequence, and the fate of each was recorded. In the second protocol, medium or large (6 x 30-mm) clots were sequentially introduced until filter occlusion occurred or 50 clots had been delivered. RESULTS: For the first protocol, 82% of first small clots and 60% of second clots were trapped in 20-mm tubes (P = .001) and 63% and 45%, respectively, were trapped in 26-mm tubes (P - .02). With medium clots, the proportion trapped also dropped significantly with ascending clot rank. In the second protocol the proportion of clots captured was invariably higher for the first 10 clots (P < .001 for all combinations of covariables). CONCLUSION: Filter function deteriorates with number of emboli delivered, irrespective of embolus size and simulated vein caliber.


Sujet(s)
Embolie/anatomopathologie , Filtres caves , Intervalles de confiance , Conception d'appareillage , Humains , Intubation/instrumentation , Test de matériaux/méthodes , Maquettes de structure , Écoulement pulsatoire , Propriétés de surface , Titane , Veine cave inférieure/anatomie et histologie
20.
Cardiovasc Intervent Radiol ; 18(5): 315-20, 1995.
Article de Anglais | MEDLINE | ID: mdl-8846472

RÉSUMÉ

PURPOSE: To evaluate in vitro the function efficacy of a new variable-sized, temporary venous filter, the Spring filter (SF). METHODS: The SF was tested in a flow phantom, using flexible, thin-walled polyethylene tubes 12, 14, and 16 mm in diameter to simulate veins. Clots of three sizes were used: 6 x 10 mm, 6 x 20 mm, 9 x 20 mm. Filter deployment was performed, ensuring that its functional diameter after placement was a predetermined multiple of the radius 'r' of the tube: 3.0r, 2.8r, 2.6r, 2.4r. The terminal coil was visually examined for changes in configuration. Clot retention by the filter for a period of 3 min was recorded as a success. The baseline intraluminal pressure and the maximum pressure reached after clot introduction were recorded. The trapping ability was calculated from the results for 10 clots. The effect of the following parameters on filter function were studied: size of embolus, caliber of simulated vein, and functional diameter of filter. RESULTS: The filter configuration was stable. Not a single instance of axial tilting occurred on deployment. Functional diameter was the major determinant of filter function. One hundred percent of clots were trapped irrespective of clot size and tube caliber when the functional diameter was 3.0r. Only 73% (95% confidence interval (CI): 57% - 88%) and 77% (95% CI: 61% - 92%) of small emboli were held up by the filter when the functional diameters were 2.6r and 2.4r, respectively (p = 0.0001). A significant reduction in clot trapping was encountered even with medium clots when the functional diameter was 2.4r (p = 0.02). CONCLUSION: Against the background of available data on retrievable vena caval filters, the current model of SF warrants further investigation.


Sujet(s)
Filtres caves , Conception d'appareillage , Humains , Fantômes en imagerie , Thrombose/thérapie
SÉLECTION CITATIONS
DÉTAIL DE RECHERCHE
...