Your browser doesn't support javascript.
loading
Montrer: 20 | 50 | 100
Résultats 1 - 8 de 8
Filtrer
Plus de filtres










Base de données
Gamme d'année
1.
bioRxiv ; 2023 Feb 18.
Article de Anglais | MEDLINE | ID: mdl-36824774

RÉSUMÉ

Characterizing animal behavior requires methods to distill 3D movements from video data. Though keypoint tracking has emerged as a widely used solution to this problem, it only provides a limited view of pose, reducing the body of an animal to a sparse set of experimenter-defined points. To more completely capture 3D pose, recent studies have fit 3D mesh models to subjects in image and video data. However, despite the importance of mice as a model organism in neuroscience research, these methods have not been applied to the 3D reconstruction of mouse behavior. Here, we present ArMo, an articulated mesh model of the laboratory mouse, and demonstrate its application to multi-camera recordings of head-fixed mice running on a spherical treadmill. Using an end-to-end gradient based optimization procedure, we fit the shape and pose of a dense 3D mouse model to data-derived keypoint and point cloud observations. The resulting reconstructions capture the shape of the animal’s surface while compactly summarizing its movements as a time series of 3D skeletal joint angles. ArMo therefore provides a novel alternative to the sparse representations of pose more commonly used in neuroscience research.

2.
J Child Lang ; : 1-36, 2022 Nov 10.
Article de Anglais | MEDLINE | ID: mdl-36353801

RÉSUMÉ

What are the constraints, cues, and mechanisms that help learners create successful word-meaning mappings? This study takes up linguistic disjunction and looks at cues and mechanisms that can help children learn the meaning of or. We first used a large corpus of parent-child interactions to collect statistics on or uses. Children started producing or between 18-30 months and by 42 months, their rate of production reached a plateau. Second, we annotated for the interpretation of disjunction in child-directed speech. Parents used or mostly as exclusive disjunction, typically accompanied by rise-fall intonation and logically inconsistent disjuncts. But when these two cues were absent, disjunction was generally not exclusive. Our computational modeling suggests that an ideal learner could successfully interpret an English disjunction (as exclusive or not) by mapping forms to meanings after partitioning the input according to the intonational and logical cues available in child-directed speech.

3.
J Med Imaging (Bellingham) ; 8(5): 054501, 2021 Sep.
Article de Anglais | MEDLINE | ID: mdl-34514033

RÉSUMÉ

Purpose: To differentiate oncocytoma and chromophobe renal cell carcinoma (RCC) using radiomics features computed from spherical samples of image regions of interest, "radiomic biopsies" (RBs). Approach: In a retrospective cohort study of 102 CT cases [68 males (67%), 34 females (33%); mean age ± SD, 63 ± 12 years ], we pathology-confirmed 42 oncocytomas (41%) and 60 chromophobes (59%). A board-certified radiologist performed two RB rounds. From each RB round, we computed radiomics features and compared the performance of a random forest and AdaBoost binary classifier trained from the features. To control for overfitting, we performed 10 rounds of 70% to 30% train-test splits with feature-selection, cross-validation, and hyperparameter-optimization on each split. We evaluated the performance with test ROC AUC. We tested models on data from the other RB round and compared with the same round testing with the DeLong test. We clustered important features for each round and measured a bootstrapped adjusted Rand index agreement. Results: Our best classifiers achieved an average AUC of 0.71 ± 0.024 . We found no evidence of an effect for RB round ( p = 1 ). We also found no evidence for a decrease in model performance when tested on the other RB round ( p = 0.85 ). Feature clustering produced seven clusters in each RB round with high agreement ( Rand index = 0.981 ± 0.002 , p < 0.00001 ). Conclusions: A consistent radiomic signature can be derived from RBs and could help distinguish oncocytoma and chromophobe RCC.

4.
Front Cardiovasc Med ; 8: 667849, 2021.
Article de Anglais | MEDLINE | ID: mdl-34026874

RÉSUMÉ

Background: Greater red and processed meat consumption has been linked to adverse cardiovascular outcomes. However, the impact of these exposures on cardiovascular magnetic resonance (CMR) phenotypes has not been adequately studied. Objective: We describe novel associations of meat intake with cardiovascular phenotypes and investigate underlying mechanisms through consideration of a range of covariates. Design: We studied 19,408 UK Biobank participants with CMR data available. Average daily red and processed meat consumption was determined through food frequency questionnaires and expressed as a continuous variable. Oily fish was studied as a comparator, previously associated with favourable cardiac outcomes. We considered associations with conventional CMR indices (ventricular volumes, ejection fraction, stroke volume, left ventricular mass), novel CMR radiomics features (shape, first-order, texture), and arterial compliance measures (arterial stiffness index, aortic distensibility). We used multivariable linear regression to investigate relationships between meat intake and cardiovascular phenotypes, adjusting for confounders (age, sex, deprivation, educational level, smoking, alcohol intake, exercise) and potential covariates on the causal pathway (hypertension, hypercholesterolaemia, diabetes, body mass index). Results: Greater red and processed meat consumption was associated with an unhealthy pattern of biventricular remodelling, worse cardiac function, and poorer arterial compliance. In contrast, greater oily fish consumption was associated with a healthier cardiovascular phenotype and better arterial compliance. There was partial attenuation of associations between red meat and conventional CMR indices with addition of covariates potentially on the causal pathway, indicating a possible mechanistic role for these cardiometabolic morbidities. However, other associations were not altered with inclusion of these covariates, suggesting importance of alternative biological mechanisms underlying these relationships. Radiomics analysis provided deeper phenotyping, demonstrating association of the different dietary habits with distinct ventricular geometry and left ventricular myocardial texture patterns. Conclusions: Greater red and processed meat consumption is associated with impaired cardiovascular health, both in terms of markers of arterial disease and of cardiac structure and function. Cardiometabolic morbidities appeared to have a mechanistic role in the associations of red meat with ventricular phenotypes, but less so for other associations suggesting importance of alternative mechanism for these relationships.

5.
Front Cardiovasc Med ; 8: 763361, 2021.
Article de Anglais | MEDLINE | ID: mdl-35004880

RÉSUMÉ

Background: Cardiovascular magnetic resonance (CMR) radiomics analysis provides multiple quantifiers of ventricular shape and myocardial texture, which may be used for detailed cardiovascular phenotyping. Objectives: We studied variation in CMR radiomics phenotypes by age and sex in healthy UK Biobank participants. Then, we examined independent associations of classical vascular risk factors (VRFs: smoking, diabetes, hypertension, high cholesterol) with CMR radiomics features, considering potential sex and age differential relationships. Design: Image acquisition was with 1.5 Tesla scanners (MAGNETOM Aera, Siemens). Three regions of interest were segmented from short axis stack images using an automated pipeline: right ventricle, left ventricle, myocardium. We extracted 237 radiomics features from each study using Pyradiomics. In a healthy subset of participants (n = 14,902) without cardiovascular disease or VRFs, we estimated independent associations of age and sex with each radiomics feature using linear regression models adjusted for body size. We then created a sample comprising individuals with at least one VRF matched to an equal number of healthy participants (n = 27,400). We linearly modelled each radiomics feature against age, sex, body size, and all the VRFs. Bonferroni adjustment for multiple testing was applied to all p-values. To aid interpretation, we organised the results into six feature clusters. Results: Amongst the healthy subset, men had larger ventricles with dimmer and less texturally complex myocardium than women. Increasing age was associated with smaller ventricles and greater variation in myocardial intensities. Broadly, all the VRFs were associated with dimmer, less varied signal intensities, greater uniformity of local intensity levels, and greater relative presence of low signal intensity areas within the myocardium. Diabetes and high cholesterol were also associated with smaller ventricular size, this association was of greater magnitude in men than women. The pattern of alteration of radiomics features with the VRFs was broadly consistent in men and women. However, the associations between intensity based radiomics features with both diabetes and hypertension were more prominent in women than men. Conclusions: We demonstrate novel independent associations of sex, age, and major VRFs with CMR radiomics phenotypes. Further studies into the nature and clinical significance of these phenotypes are needed.

6.
Front Cardiovasc Med ; 7: 586236, 2020.
Article de Anglais | MEDLINE | ID: mdl-33344517

RÉSUMÉ

Aims: To evaluate the repeatability of cardiac magnetic resonance (CMR) radiomics features on test-retest scanning using a multi-centre multi-vendor dataset with a varied case-mix. Methods and Results: The sample included 54 test-retest studies from the VOLUMES resource (thevolumesresource.com). Images were segmented according to a pre-defined protocol to select three regions of interest (ROI) in end-diastole and end-systole: right ventricle, left ventricle (LV), and LV myocardium. We extracted radiomics shape features from all three ROIs and, additionally, first-order and texture features from the LV myocardium. Overall, 280 features were derived per study. For each feature, we calculated intra-class correlation coefficient (ICC), within-subject coefficient of variation, and mean relative difference. We ranked robustness of features according to mean ICC stratified by feature category, ROI, and cardiac phase, demonstrating a wide range of repeatability. There were features with good and excellent repeatability (ICC ≥ 0.75) within all feature categories and ROIs. A high proportion of first-order and texture features had excellent repeatability (ICC ≥ 0.90), however, these categories also contained features with the poorest repeatability (ICC < 0.50). Conclusion: CMR radiomic features have a wide range of repeatability. This paper is intended as a reference for future researchers to guide selection of the most robust features for clinical CMR radiomics models. Further work in larger and richer datasets is needed to further define the technical performance and clinical utility of CMR radiomics.

7.
Tomography ; 6(2): 111-117, 2020 06.
Article de Anglais | MEDLINE | ID: mdl-32548287

RÉSUMÉ

Several institutions have developed image feature extraction software to compute quantitative descriptors of medical images for radiomics analyses. With radiomics increasingly proposed for use in research and clinical contexts, new techniques are necessary for standardizing and replicating radiomics findings across software implementations. We have developed a software toolkit for the creation of 3D digital reference objects with customizable size, shape, intensity, texture, and margin sharpness values. Using user-supplied input parameters, these objects are defined mathematically as continuous functions, discretized, and then saved as DICOM objects. Here, we present the definition of these objects, parameterized derivations of a subset of their radiomics values, computer code for object generation, example use cases, and a user-downloadable sample collection used for the examples cited in this paper.


Sujet(s)
Traitement d'image par ordinateur , Radiométrie , Logiciel , Radiométrie/normes , Normes de référence
8.
Eur Heart J Cardiovasc Imaging ; 21(4): 349-356, 2020 04 01.
Article de Anglais | MEDLINE | ID: mdl-32142107

RÉSUMÉ

Radiomics is a novel image analysis technique, whereby voxel-level information is extracted from digital images and used to derive multiple numerical quantifiers of shape and tissue character. Cardiac magnetic resonance (CMR) is the reference imaging modality for assessment of cardiac structure and function. Conventional analysis of CMR scans is mostly reliant on qualitative image analysis and basic geometric quantifiers. Small proof-of-concept studies have demonstrated the feasibility and superior diagnostic accuracy of CMR radiomics analysis over conventional reporting. CMR radiomics has the potential to transform our approach to defining image phenotypes and, through this, improve diagnostic accuracy, treatment selection, and prognostication. The purpose of this article is to provide an overview of radiomics concepts for clinicians, with particular consideration of application to CMR. We will also review existing literature on CMR radiomics, discuss challenges, and consider directions for future work.


Sujet(s)
Imagerie diagnostique , Coeur , Imagerie par résonance magnétique , Spectroscopie par résonance magnétique
SÉLECTION CITATIONS
DÉTAIL DE RECHERCHE
...