Your browser doesn't support javascript.
loading
Montrer: 20 | 50 | 100
Résultats 1 - 1 de 1
Filtrer
Plus de filtres










Base de données
Gamme d'année
1.
Eur J Nucl Med Mol Imaging ; 50(3): 701-714, 2023 02.
Article de Anglais | MEDLINE | ID: mdl-36326869

RÉSUMÉ

PURPOSE: The PET scanners with long axial field of view (AFOV) having ~ 20 times higher sensitivity than conventional scanners provide new opportunities for enhanced parametric imaging but suffer from the dramatically increased volume and complexity of dynamic data. This study reconstructed a high-quality direct Patlak Ki image from five-frame sinograms without input function by a deep learning framework based on DeepPET to explore the potential of artificial intelligence reducing the acquisition time and the dependence of input function in parametric imaging. METHODS: This study was implemented on a large AFOV PET/CT scanner (Biograph Vision Quadra) and twenty patients were recruited with 18F-fluorodeoxyglucose (18F-FDG) dynamic scans. During training and testing of the proposed deep learning framework, the last five-frame (25 min, 40-65 min post-injection) sinograms were set as input and the reconstructed Patlak Ki images by a nested EM algorithm on the vendor were set as ground truth. To evaluate the image quality of predicted Ki images, mean square error (MSE), peak signal-to-noise ratio (PSNR), and structural similarity index measure (SSIM) were calculated. Meanwhile, a linear regression process was applied between predicted and true Ki means on avid malignant lesions and tumor volume of interests (VOIs). RESULTS: In the testing phase, the proposed method achieved excellent MSE of less than 0.03%, high SSIM, and PSNR of ~ 0.98 and ~ 38 dB, respectively. Moreover, there was a high correlation (DeepPET: [Formula: see text]= 0.73, self-attention DeepPET: [Formula: see text]=0.82) between predicted Ki and traditionally reconstructed Patlak Ki means over eleven lesions. CONCLUSIONS: The results show that the deep learning-based method produced high-quality parametric images from small frames of projection data without input function. It has much potential to address the dilemma of the long scan time and dependency on input function that still hamper the clinical translation of dynamic PET.


Sujet(s)
Tomographie par émission de positons couplée à la tomodensitométrie , Tomographie par émission de positons , Humains , Tomographie par émission de positons/méthodes , Intelligence artificielle , , Fluorodésoxyglucose F18 , Traitement d'image par ordinateur/méthodes
SÉLECTION CITATIONS
DÉTAIL DE RECHERCHE