Your browser doesn't support javascript.
loading
Montrer: 20 | 50 | 100
Résultats 1 - 13 de 13
Filtrer
Plus de filtres











Base de données
Gamme d'année
2.
J Chromatogr A ; 1217(24): 3804-18, 2010 Jun 11.
Article de Anglais | MEDLINE | ID: mdl-20444460

RÉSUMÉ

Molecular mass ranges and average masses of fractions from a heavy Mexican crude oil (Maya) have been studied, using mainly size exclusion chromatography (SEC) and laser desorption-mass spectrometry (LD-MS). Method development focused on the use of planar chromatography and size exclusion chromatography (SEC), to isolate narrow bands of material from solubility-separated fractions of the crude oil. The procedure provides a planar chromatography based method for studying mass ranges in complex hydrocarbon mixtures. It allows the calculation of 'best estimate' values for number and mass-averages. These can then be used in average structural parameter (ASP) calculations, for studying structural features of the samples. The method is applicable to both coal and petroleum-derived samples. The molecular mass estimates arrived at in this work for petroleum-derived samples are considerably higher than those reported by other workers for similar samples. The results presented here provide strong evidence for the presence of ions approaching m/z 10,000 in the Maya asphaltene. The maltene fraction was found to contain a small amount of ions with mass (m/z) in excess of 2000.


Sujet(s)
Chromatographie sur gel/méthodes , Pétrole/analyse , Mexique , Masse moléculaire , Solubilité , Spectrométrie de fluorescence , Spectrométrie de masse MALDI
3.
Rapid Commun Mass Spectrom ; 23(13): 2087-98, 2009 Jul.
Article de Anglais | MEDLINE | ID: mdl-19489019

RÉSUMÉ

A coal tar pitch was fractionated by solvent solubility into heptane-solubles, heptane-insoluble/toluene-solubles (asphaltenes), and toluene-insolubles (preasphaltenes). The aim of the work was to compare the mass ranges of the different fractions by several different techniques. Thermogravimetric analysis, size-exclusion chromatography (SEC) and UV-fluorescence spectroscopy showed distinct differences between the three fractions in terms of volatility, molecular size ranges and the aromatic chromophore sizes present. The mass spectrometric methods used were gas chromatography/mass spectrometry (GC/MS), pyrolysis/GC/MS, electrospray ionization Fourier transform ion cyclotron resonance mass spectrometry (ESI-FTICRMS) and laser desorption time-of-flight mass spectrometry (LD-TOFMS). The first three techniques gave good mass spectra only for the heptane-soluble fraction. Only LDMS gave signals from the toluene-insolubles, indicating that the molecules were too involatile for GC and too complex to pyrolyze into small molecules during pyrolysis/GC/MS. ESI-FTICRMS gave no signal for toluene-insolubles probably because the fraction was insoluble in the methanol or acetonitrile, water and formic acid mixture used as solvent to the ESI source. LDMS was able to generate ions from each of the fractions. Fractionation of complex samples is necessary to separate smaller molecules to allow the use of higher laser fluences for the larger molecules and suppress the formation of ionized molecular clusters. The upper mass limit of the pitch was determined as between 5000 and 10,000 u. The pitch asphaltenes showed a peak of maximum intensity in the LDMS spectra at around m/z 400, in broad agreement with the estimate from SEC. The mass ranges of the toluene-insoluble fraction found by LDMS and SEC (400-10,000 u with maximum intensity around 2000 u by LDMS and 100-9320 u with maximum intensity around 740 u by SEC) are higher than those for the asphaltene fraction (200-4000 u with maximum intensity around 400 u by LDMS and 100-2680 u with maximum intensity around 286 u by SEC) and greater than values considered appropriate for petroleum asphaltenes (300-1200 u with maximum intensity near 700 u).


Sujet(s)
Goudron houille/composition chimique , Chromatographie sur gel/méthodes , Chromatographie gazeuse-spectrométrie de masse/méthodes , Spectrométrie de masse/méthodes , Masse moléculaire
4.
J Chromatogr A ; 1095(1-2): 81-8, 2005 Nov 18.
Article de Anglais | MEDLINE | ID: mdl-16275286

RÉSUMÉ

Soil from a redundant coke oven site has been examined by extraction of soluble materials using 1-methyl-2-pyrrolidinone (NMP) followed by size exclusion chromatography (SEC) of the extracted material. The extracted material was found to closely resemble a high temperature coal tar pitch. Standard humic and fulvic acids were also examined since these materials are very soluble in NMP and would be extracted with pitch if present in the soil. Humic substances derived from peat samples and NMP-extracts of peats were also examined. The results show that the humic and fulvic substances were not extracted directly by NMP from peats. They were extracted using caustic soda solution and were different from the peat extracts in NMP. These results indicate that humic and fulvic acids were soluble in NMP in the protonated polyelectrolyte form but not in the original native polyelectrolyte form. The extraction of soil using NMP followed by SEC appears to be a promising method for identifying contamination by coal-based industries.


Sujet(s)
Benzopyranes/analyse , Chromatographie sur gel/méthodes , Goudron houille/analyse , Substances humiques/analyse , Polluants du sol/analyse , Sol/analyse , Pyrrolidones/composition chimique , Solvants , Spectrométrie de fluorescence
5.
Article de Anglais | MEDLINE | ID: mdl-15100482

RÉSUMÉ

Casein has been pyrolysed to obtain a biochar (28.3% yield), with mostly meso- and macro-pore structure, and a liquid tar product of high yield (37.5%) with the balance as gas (20.9%) and water (13.3%). The elemental composition of the casein tar was: C 66.7%, H 8.3%, N 12.1% and O 12.9% (by difference). The tar sample has been characterised by mass spectrometry, gas chromatography (GC)/MS and heated-probe MS, to give molecular mass distributions for comparison with molecular mass ranges indicated by analytical-scale size-exclusion chromatography (SEC). The tar appeared to be completely soluble in 1-methyl-2-pyrrolidinone (NMP), the solvent used for SEC. It appeared to consist mostly of lower molecular mass fractions with elution times at 18-26 min. GC/MS analysis showed the presence of both aliphatic and aromatic nitrogen-containing components. Neither GC/MS nor heated-probe MS were able to detect more than about half the tar components.


Sujet(s)
Caséines/composition chimique , Chromatographie sur gel/méthodes , Chromatographie gazeuse-spectrométrie de masse/méthodes , Température élevée , Pyrrolidones/composition chimique , Goudrons/composition chimique , Animaux , Bovins , Masse moléculaire , Sensibilité et spécificité
6.
J Chromatogr A ; 1024(1-2): 227-43, 2004 Jan 23.
Article de Anglais | MEDLINE | ID: mdl-14753725

RÉSUMÉ

A coal tar pitch and a petroleum vacuum residue have been separated by TLC using pyridine, acetonitrile, toluene and pentane to develop the chromatograms. The bands of material detected were recovered in 1-methyl-2-pyrrolidinone (NMP) solvent and examined by size-exclusion chromatography (SEC) in NMP eluent. The relation between elution time in SEC and mobility on the TLC plate indicated that molecular size increased steadily with increasing immobility on the plate. This relation was reinforced by UV fluorescence spectroscopy in that the fluorescence moved to longer wavelengths with increasing immobility. The molecular size of the material excluded from the porosity of the SEC column remains undefined; some excluded material was found in all of the fractions from both samples. The valley of zero intensity separating the retained material from the excluded material may suggest a change of structure from near-planar in the retained region to three-dimensional in the excluded region.


Sujet(s)
Chromatographie sur gel/méthodes , Chromatographie sur couche mince/méthodes , Spectrométrie de fluorescence , Spectrophotométrie UV , Vide
7.
Rapid Commun Mass Spectrom ; 16(8): 774-84, 2002.
Article de Anglais | MEDLINE | ID: mdl-11921262

RÉSUMÉ

A low-temperature coal tar has been fractionated by column chromatography into acetonitrile, pyridine and 1-methyl-2-pyrrolidinone- (NMP) solubles. The tar and its fractions have been examined by pyrolysis-gas chromatography/mass spectrometry (GC/MS). Fractionation by planar chromatography was also carried out for purposes of comparison. Molecular masses of the fractions were estimated by size-exclusion chromatography (SEC), and bulk structural characterisation was carried out by (13)C-NMR and UV-fluorescence spectrometry. SEC showed that the fractions shifted to progressively shorter elution times (higher apparent masses) with diminishing solubility, i.e. from acetonitrile to NMP solubles. UV-fluorescence spectra showed parallel shifts to longer wavelengths and lower fluorescence quantum yields, indicating increasing sizes of aromatic ring systems and increasingly complex molecules. GC/MS analysis of the tar showed alkanes from C10 to C32 and extensive series of alkylated aromatics, phenols, indenes, naphthalenes, phenanthrenes and fluoranthenes. Pyrolysis-GC/MS results for the acetonitrile solubles closely resembled the data for the tar sample, with extensive series of alkylated benzenes, phenols and naphthalenes as well as alkanes from C16 to C28. The pyridine-soluble fraction showed no significant aromatic pyrolysis products and only relatively weak signals for alkanes between C16 and C27. The NMP-soluble fraction showed even less overall signal, with no significant aromatic components and weak signals for alkanes between C21 and C25, even though (13)C-NMR analyses showed that approximately half of the carbon detected was aromatic. The aliphatics are assumed to provide bridging structures between polycyclic aromatic (PCA) ring systems.

8.
J Chromatogr A ; 919(2): 255-66, 2001 Jun 15.
Article de Anglais | MEDLINE | ID: mdl-11442030

RÉSUMÉ

The structure and composition of products from the reaction of anthracene oil with anhydrous AlCl3 have been examined. Size-exclusion chromatography has been carried out using a column with polystyrene-polydivinylbenzene as stationary phase, 1-methyl-2-pyrrolidinone at 80 degrees C as eluent and variable-wavelength UV-absorption detection. This system provides a chromatogram of the sample with several peaks. Molecular masses corresponding to these peaks were estimated using a calibration curve obtained with polycyclic aromatic hydrocarbon standards, ranging from 92 to 532 u. The most abundant compounds of the substrate were dimers and trimers of the main anthracene oil components. These results are corroborated on a qualitative level by synchronous UV-fluorescence spectra.


Sujet(s)
Composés de l'aluminium/composition chimique , Anthracènes/composition chimique , Chlorures/composition chimique , Chromatographie sur gel/méthodes , Huiles/composition chimique , Polymères/composition chimique , Chlorure d'aluminium , Calibrage , Analyse spectrale
9.
Rapid Commun Mass Spectrom ; 15(11): 845-56, 2001.
Article de Anglais | MEDLINE | ID: mdl-11382931

RÉSUMÉ

A sample of Baltic amber ( approximately 40 million yrs old) has been extracted using pentane, toluene and 1-methyl-2-pyrrolidinone (NMP). The relationship between solubility characteristics of the extracts in relation to molecular mass and chemical makeup has been investigated. The extracts were first characterised by (13)C-NMR spectrometry, size exclusion chromatography (SEC) and UV-fluorescence spectroscopy. The fractions differed less in terms of chemical structural features than they did in terms of molecular mass. This contrasts markedly with data on fractions of coal-derived liquids, but parallels results from petroleum-derived vacuum residues. In SEC, the toluene soluble/pentane insoluble fraction gave a peak for high mass material at about 67 000 u. Material excluded from the column porosity in this fraction and in NMP solubles eluted between 8 and 11 min, corresponding to polystyrene masses between 200 000 and several million u. A column with a larger pore size distribution was calibrated using polystyrene and polymethylmethacrylate standards with detection by a light-scattering evaporative analyser. The largest polystyrene standard (15.4 million u) eluted at 13.4 min, similar to that of the earliest eluting amber-derived material in the NMP solubles fraction. Results from probe-MS and pyrolysis-GC/MS have been used to confirm the similarity of chemical structures of the three solubility fractions. Broadly, low mass ions appear to correspond to the various monomeric units of structures present in the amber, the higher mass ions to dimer units and the molecular ions to the different combinations of three or more monomeric units. The main monomer groups have been identified in detail, showing a situation very different from that of coal-derived materials, where the sizes of aromatic ring systems increase with molecular size.

10.
Rapid Commun Mass Spectrom ; 14(19): 1766-82, 2000.
Article de Anglais | MEDLINE | ID: mdl-11006584

RÉSUMÉ

The structural characterisation of a coal liquefaction extract and its three fractions separated by planar chromatography has been described. Size exclusion chromatography showed the molecular mass distributions to become progressively larger with decreasing mobility on the plate. UV-fluorescence spectroscopy of the fractions indicated parallel increases in the sizes of polynuclear aromatic ring systems. Analysis by probe-mass spectrometry of the 'whole' coal extract showed the expected array of small polynuclear aromatic groups extending to m/z 450. The probe mass spectra of the lightest fraction ('mobile in pyridine and acetonitrile') showed similar features, except for effects due to vacuum drying to remove solvent. In sharp contrast, the two heaviest fractions ('mobile in pyridine and immobile in acetonitrile' and 'immobile in pyridine') showed no significant ions other than those from residual NMP solvent (m/z 98 and 99). Pyrolysis-gas chromatography/mass spectrometry of these two heaviest fractions showed only traces of aromatic compounds or fragments. The aromatic pyrolysis products of these fractions were too large and involatile to pass through the GC column. The major components observed in the pyrolysis-gas chromatography/mass spectrometry of the two heavy fractions were alkanes and alkenes, ranging between C10-C25. Since none of the samples contained free alkanes, alkenes or cycloalkanes before pyrolysis, they were generated during the pyrolysis step. The shifts of UV-fluorescence spectral intensity to shorter wavelengths with decreasing size indicated by size exclusion chromatography (SEC) provide direct evidence of differences in structure with changing molecular mass. This evidence strongly suggests that species identified as being of large molecular mass in this extract sample are not composed of molecular aggregates. It remains difficult to establish whether and when it would be legitimate to invoke molecular aggregates to explain the large molecular masses (MMs) identified here and in other work. Copyright 2000 John Wiley & Sons, Ltd.

11.
Rapid Commun Mass Spectrom ; 14(5): 317-28, 2000.
Article de Anglais | MEDLINE | ID: mdl-10700033

RÉSUMÉ

1-Methyl-2-pyrrolidinone (NMP) was used to extract samples of wood (forest residue) and coal; the extracts were analysed by inductively coupled plasma mass spectrometry (ICP-MS) using two different sample preparation methods, in order to identify trace elements associated with the organic part of the samples. A sample of fly ash was similarly extracted and analysed in order to assess the behaviour of the mineral matter contained within the wood and coal samples. 32% of the biomass was extracted at the higher temperature and 12% at room temperature while only 12% of the coal was extracted at the higher temperature and 3% at room temperature. Less than 2% of the ash dissolved at the higher temperature. Size exclusion chromatograms of the extracts indicated the presence of significant amounts of large molecular mass materials (>1000 mu) in the biomass and coal extracts but not in the ash extract. Trace element analyses were carried out using ICP-MS on the acid digests prepared by 'wet ashing' and microwave extraction. Sixteen elements (As, Ba, Be, Cd, Co, Cr, Cu, Ga, Mn, Mo, Ni, Pb, Sb, Se, V and Zn) were quantified, in the samples before extraction, in the extracts and in the residues. Concentrations of trace elements in the original biomass sample were lower than in the coal sample while the concentrations in the ash sample were the highest. The major trace elements in the NMP extracts were Ba, Cu, Mn and Zn from the forest residue; Ba, Cu, Mn, Pb and Zn from the coal; Cu and Zn from the ash. These elements are believed to be associated with the organic extracts from the forest residue and coal, and also from the ash. Be and Sb were not quantified in the extracts because they were present at too low concentrations; up to 40% of Mn was extracted from the biomass sample at 202 degrees C, while Se was totally extracted from the ash sample. For the forest residue, approximately 7% (at room temperature) and 45% (at 202 degrees C) of the total trace elements studied were in the extract; for the coal, approximately 8% (at room temperature) and 23% (at 202 degrees C) were in the extract. For the ash, only 1.4% of the trace elements were extracted at 202 degrees C, comprising 25% of Cd but less than 1% of Pb.


Sujet(s)
Charbon/analyse , Oligoéléments/analyse , Bois , Biomasse , Indicateurs et réactifs , Spectrométrie de masse/méthodes
12.
Rapid Commun Mass Spectrom ; 14(5): 335-43, 2000.
Article de Anglais | MEDLINE | ID: mdl-10700035

RÉSUMÉ

Most of the analytical techniques used to quantify elements associated with solid samples suffer from high detection limits and cannot be used for trace elements in biomass samples, particularly when only 20 mg are available for analysis. Inductively coupled plasma mass spectrometry (ICP-MS) can achieve detection limits of parts-per-trillion with liquid sample introduction by solution nebulisation. This technique was therefore tested with two standard biomass reference materials: oriental tobacco leaves and cabbage leaves. Two preparations successfully used on coal standards were used to digest the solid samples: a total digestion method (wet ashing digestion) and a partial leaching (microwave extraction). The concentrations of up to seventeen elements (As, Ba, Be, Cd, Co, Cr, Cu, Ga, Mn, Mo, Ni, Pb, Sb, Se, Sn, V and Zn) were measured after the two preparations. The accuracy and sensitivity of the measurements improved when the dilution factor decreased from 5000 to 1000 and to 500. Since the proportion of mineral matter in biomass samples is small (5%), the microwave digestion extracted elements that are generally not completely extracted from coal samples (e.g. Sb). However, some trace element concentrations were below the limit of quantification after microwave extraction, even with a reduced dilution factor (As, Se and Mo) and could not be quantified. A fuel oil was also digested. The trace element concentrations were very low (between 28 and 0.1 microgram g(-1)) but acceptable results were obtained by applying a dilution factor of 100. Only six elements in the fuel oil (As, Ba, Co, Ni, Se and V) had certified or indicated values. Factors affecting the accuracy and sensitivity of the analyses are discussed. The reproducibility of analysis of the tobacco leaf standard was checked over a period of nine months by both digestion methods. The wet ashing method gave acceptable reproducibility for Ba, Cd, Co, Cu, Ga, Mn, Mo, Ni, Pb, V and Zn but poor precision for Cr, Se and Sn and showed evidence of residual chloride interference for As. The microwave extraction gave good reproducibility for As, Ba, Cd, Co, Cr, Cu, Mo, Ni and Zn but poor precision for Se and low recoveries for Ga, Mn, Sn and V. In spite of the small quantities of material analysed, it proved possible to determine the trace elements at levels down to 0.1 microgram g(-1) in the reference materials.


Sujet(s)
Biomasse , Mazout/analyse , Oligoéléments/analyse , Spectrométrie de masse/méthodes , Reproductibilité des résultats , Sensibilité et spécificité
13.
Rapid Commun Mass Spectrom ; 13(14): 1401-12, 1999.
Article de Anglais | MEDLINE | ID: mdl-10407331

RÉSUMÉ

Three methods for determining a 'safe' estimate for high-mass limits of MALDI spectra of coal derived liquids were explored, using a sample of coal-tar pitch and its pyridine-insoluble fraction. Co-addition of increasing numbers of single-shot spectra (10, 30, 50 and 100 pulses) showed visually observable reductions in noise levels, consistent with robust and statistically meaningful signals. Three separate types of post-acquisition calculation were used to identify high-mass limits of the spectra. (i) A literature method indicated high-mass limits similar to those observed visually-as a shift from baseline at the highest masses, nearly 350 000 u for the coal tar pitch and about 390 000 u for its pyridine insoluble fraction. (ii) Comparing instrument signal with pre-selected multiples of the standard deviation, upper mass estimates of between 40-60 000 u for the coal-tar pitch and about 95 000 u for its pyridine-insoluble fraction were found. (iii) Calculation of the slope was used to identify 'lift-off' of the spectrum from baseline. The angle between the smoothed spectrum and the baseline was matched to a pre-selected value (e.g. 0.5 degrees and 1 degrees ). However, the arbitrary specification of the key parameter did not establish this last method on a firm basis. The choice of a criterion for estimating high-mass limits of MALDI spectra remains a semi-quantitative procedure; a reasonably conservative high-mass limit may be estimated by comparison of signal with five times the standard deviation. However, evaluation of size exclusion chromatograms of the present samples using polystyrene standards suggests that molecular mass distributions of pitch samples arrived at by MALDI mass spectrometry are, at least partly, determined by the limitations of available instruments. Copyright 1999 John Wiley & Sons, Ltd.

SÉLECTION CITATIONS
DÉTAIL DE RECHERCHE