Your browser doesn't support javascript.
loading
Montrer: 20 | 50 | 100
Résultats 1 - 20 de 40
Filtrer
1.
Clin Neuroradiol ; 28(3): 367-376, 2018 Sep.
Article de Anglais | MEDLINE | ID: mdl-28265679

RÉSUMÉ

PURPOSE: To evaluate the performance of an innovative image processing approach for detection of T2-weighted hyperintense multiple sclerosis (MS) lesions. METHODS: In this study 20 consecutive patients with inflammatory demyelinating lesions were retrospectively evaluated of whom 10 patients featured progressive disease and 10 a stable lesion load. 3 mm transversal FLAIRfusion imaging was processed and archived. Image processing was performed through landmark-based 3D co-registration of the previous and current isotropic FLAIR examination followed by inversion of image contrast. Thereby, the hyperintense signals of the unchanged MS plaques extinguish each other, while newly developed lesions appear bright on FLAIRfusion. Diagnostic performance was evaluated by 4 experienced readers. Consensus reading supplied the reference standard. Sensitivity, specificity, NPV (negative predictive value), PPV (positive predictive value), interreader agreement and reading time were the outcome measures analyzed. RESULTS: Combined sensitivity was 100% at a specificity of 88.2%, with PPV ranging from 83.3% to 90.1% and NPV at 100%. Reading time was nearly 5­fold faster than conventional side by side comparison (35.6 s vs. 163.7 s, p < 0.001). Cohen's kappa was excellent (>0.75; p < 0.001) and Cronbach's alpha was 0.994. CONCLUSION: FLAIRfusion provides reliable detection of newly developed MS lesions along with strong interreader agreement across all levels of expertise in 35 s of reading time.


Sujet(s)
Encéphale/imagerie diagnostique , Traitement d'image par ordinateur , Imagerie par résonance magnétique , Sclérose en plaques/imagerie diagnostique , Adulte , Femelle , Allemagne , Humains , Mâle , Adulte d'âge moyen , Lecture , Études rétrospectives , Sensibilité et spécificité , Jeune adulte
2.
AJNR Am J Neuroradiol ; 38(3): 596-602, 2017 Mar.
Article de Anglais | MEDLINE | ID: mdl-28104636

RÉSUMÉ

BACKGROUND AND PURPOSE: Endovascular flow diverters are increasingly used for the treatment of cerebral aneurysms. We assessed the safety and efficacy of the Flow-Redirection Endoluminal Device (FRED) in a consecutive series of 50 patients. MATERIALS AND METHODS: Inclusion criteria were wide-neck, blister-like, or fusiform/dissecting aneurysms independent of size, treated with the FRED between February 2014 and May 2015. Assessment criteria were aneurysm occlusion, manifest ischemic stroke, bleeding, or death. The occlusion rate was assessed at 3 months with flat panel CT and at 6 months with DSA by using the Raymond classification and the O'Kelly-Marotta grading scale. RESULTS: Fifty patients with 52 aneurysms were treated with 54 FREDs; 20 patients were treated with the FRED and coils. Aneurysm size ranged from 2.0 to 18.5 mm. Deployment of the FRED was successful in all cases. There were no device-associated complications. One patient developed mild stroke symptoms that fully receded within days. There have been no late-term complications so far and no treatment-related mortality. Initial follow-up at 3 months showed complete occlusion in 72.3% of the overall study group, Six-month follow-up showed total and remnant-neck occlusion in 87.2% of patients, distributed over 81.5% of the FRED-only cases and 95.0% of the cases with combined treatment. CONCLUSIONS: The FRED flow diverter is a safe device for the treatment of cerebral aneurysms of various types. Our data reveal high occlusion rates at 3 and 6 months, comparable with those in other flow diverters. Long-term occlusion rates are expected.


Sujet(s)
Implantation de prothèses vasculaires/méthodes , Prothèse vasculaire , Anévrysme intracrânien/chirurgie , Adulte , Sujet âgé , Prothèse vasculaire/effets indésirables , Implantation de prothèses vasculaires/effets indésirables , Implantation de prothèses vasculaires/instrumentation , Encéphalopathie ischémique/imagerie diagnostique , Encéphalopathie ischémique/chirurgie , Angiographie cérébrale , Procédures endovasculaires/instrumentation , Femelle , Études de suivi , Humains , Anévrysme intracrânien/imagerie diagnostique , Angiographie par résonance magnétique , Mâle , Adulte d'âge moyen , Sécurité des patients , Accident vasculaire cérébral/imagerie diagnostique , Accident vasculaire cérébral/chirurgie , Résultat thérapeutique
3.
Clin Neuroradiol ; 27(1): 43-49, 2017 Mar.
Article de Anglais | MEDLINE | ID: mdl-26104272

RÉSUMÉ

OBJECTIVE: Knowledge on the influence of 2D and 3D coils to occlude intracranial aneurysms is poor. Therefore, aim of our analysis was to evaluate whether the use of 3-D versus 2-D coils alone may improve the efficacy of endovascular aneurysm treatment. PATIENTS AND METHODS: We performed a matched pair analysis comparing aneurysms treated by 3-D coils as initial "framing" coils to aneurysms treated exclusively by 2-D coils. Number of coils, implanted coil length/volume, and associated packing density were calculated. Aneurysmal occlusion was assessed and monitored 6 months (DSA; magnetic resonance angiography (MRA)) and 18 months (MRA) after embolization. Periprocedural complications and retreatment rate of each group were analyzed. RESULTS: Our retrospective analysis revealed 50 pairs. Concerning the 3-D group, number of coils (353 in total, median 7; p = 0.002), implanted coil length (55.69 ± 48.4 cm), implanted coil length per volume (5.92 mm/mm3), and packing density (30 %; p = 0.017) was higher than in the 2-D group (259 in total, median 5 coils; 38.52 ± 43.13 cm; 4.54 mm/mm3; 23 %). Occlusion was not significantly different immediately after treatment but at 6 and 18 months follow-up in favor of 3-D coils. Retreatment was performed in 2 cases of the 3-D group and in 3 cases of the 2-D group and therefore in a similar range (p = 0.564). CONCLUSION: Initial use of 3-D coils revealed a higher packing density and a higher long-term occlusion. Therefore, we recommend initial use of 3-D coils.


Sujet(s)
Procédures endovasculaires/instrumentation , Procédures endovasculaires/statistiques et données numériques , Anévrysme intracrânien/épidémiologie , Anévrysme intracrânien/chirurgie , Complications postopératoires/épidémiologie , Conception d'appareillage , Analyse de panne d'appareillage , Femelle , Allemagne/épidémiologie , Humains , Anévrysme intracrânien/imagerie diagnostique , Études longitudinales , Mâle , Analyse appariée , Adulte d'âge moyen , Complications postopératoires/imagerie diagnostique , Complications postopératoires/prévention et contrôle , Prévalence , Études rétrospectives , Résultat thérapeutique
4.
Clin Neuroradiol ; 26(3): 309-15, 2016 Sep.
Article de Anglais | MEDLINE | ID: mdl-25410583

RÉSUMÉ

PURPOSE: It has been reported that the extent of intravascular thrombi and the quality of collateral filling in computed tomography (CT) angiography are predictive for the clinical outcome in patients with acute stroke. We hypothesized that multi-phase four-dimensional CTA (4D-CTA) allows better assessment of clot burden and collateral flow compared with arterial single-phase CTA (CTA). METHODS: In 49 patients (33 female; age: 77 ± 12 years) with acute anterior circulation stroke, CTA and 4D-CTA reconstructed from dynamic perfusion CT data were analyzed for absolute thrombus length (TL), clot burden score (CBS), and collateral score (CS). The length of the filling defect was also defined on thin-slice nonenhanced CT as corresponding hyperdense middle cerebral artery sign (HMCAS) when present. RESULTS: There was good correlation (r = 0.62, p < 0.01) between the length of HMCAS (1.29 ± 0.62 cm) and TL in 4D-CTA (1.22 ± 0.51 cm). 4D-CTA and CTA significantly varied (p < 0.01) in TL (1.42 ± 0.73 cm (CTA) versus 1.11 ± 0.62 cm (4D-CTA)), CBS (median: 5, interquartile range: 4-7 (CTA) versus median: 6, interquartile range: 5-8 (4D-CTA); p < 0.001), and CS (median: 2, interquartile range: 1-2 (CTA) versus median: 3, interquartile range: 2-3 (4D-CTA); p < 0.001). Accordingly, CTA significantly overrated clot burden and underestimated collateral flow. CONCLUSIONS: 4D-CTA more closely defines clot burden and collateral supply in anterior circulation stroke than CTA, implicating an additional diagnostic benefit.


Sujet(s)
Infarctus encéphalique/imagerie diagnostique , Angiographie cérébrale/méthodes , Angiographie par tomodensitométrie/méthodes , Tomodensitométrie 4D/méthodes , Thrombose intracrânienne/imagerie diagnostique , Amélioration d'image radiographique/méthodes , Sujet âgé , Algorithmes , Infarctus encéphalique/complications , Diagnostic différentiel , Femelle , Humains , Thrombose intracrânienne/étiologie , Mâle , Reproductibilité des résultats , Sensibilité et spécificité
5.
Clin Neuroradiol ; 25 Suppl 2: 291-7, 2015 Oct.
Article de Anglais | MEDLINE | ID: mdl-26091842

RÉSUMÉ

Originally aimed at improving standard radiography by providing higher absorption efficiency and a wider dynamic range, flat-panel detector technology has meanwhile got widely accepted in the neuroradiological community. Especially flat-panel detector computed tomography (FD-CT) using rotational C-arm mounted flat-panel detector technology is capable of volumetric imaging with a high spatial resolution. By providing CT-like images of the brain within the angio suite, FD-CT is able to rapidly visualize hemorrhage and may thus improve complication management without the need of patient transfer. As "Angiographic CT" FD-CT may be helpful during many diagnostic and neurointerventional procedures and for noninvasive monitoring and follow-up. In addition, spinal interventions and high-resolution imaging of the temporal bone might also benefit from FD-CT. Finally, using novel dynamic perfusion and angiographic protocols, FD-CT may provide functional information on brain perfusion and vasculature with the potential to replace standard imaging in selected acute stroke patients.


Sujet(s)
Angiographie/méthodes , Neuroradiographie/méthodes , Amélioration d'image radiographique/instrumentation , Amélioration d'image radiographique/méthodes , Tomodensitométrie/méthodes , Angiographie/instrumentation , Humains , Neuroradiographie/instrumentation , Accident vasculaire cérébral/imagerie diagnostique , Tomodensitométrie/instrumentation
6.
AJNR Am J Neuroradiol ; 36(10): 1964-70, 2015 Oct.
Article de Anglais | MEDLINE | ID: mdl-26066625

RÉSUMÉ

BACKGROUND AND PURPOSE: Perfusion and angiographic imaging using intravenous contrast application to evaluate stroke patients is now technically feasible by flat detector CT performed by the angiographic system. The aim of this pilot study was to show the feasibility and qualitative comparability of a novel flat detector CT dynamic perfusion and angiographic imaging protocol in comparison with a multimodal stroke MR imaging protocol. MATERIALS AND METHODS: In 12 patients with acute stroke, MR imaging and the novel flat detector CT protocol were performed before endovascular treatment. Perfusion parameter maps (MTT, TTP, CBV, CBF) and MIP/volume-rendering technique images obtained by using both modalities (MR imaging and flat detector CT) were compared. RESULTS: Comparison of MIP/volume-rendering technique images demonstrated equivalent visibility of the occlusion site. Qualitative comparison of perfusion parameter maps by using ASPECTS revealed high Pearson correlation coefficients for parameters CBF, MTT, and TTP (0.95-0.98), while for CBV, the coefficient was lower (0.49). CONCLUSIONS: We have shown the feasibility of a novel dynamic flat detector CT perfusion and angiographic protocol for the diagnosis and triage of patients with acute ischemic stroke. In a qualitative comparison, the parameter maps and MIP/volume-rendering technique images compared well with MR imaging. In our opinion, this flat detector CT application may substitute for multisection CT imaging in selected patients with acute stroke so that in the future, patients with acute stroke may be directly referred to the angiography suite, thereby avoiding transportation and saving time.


Sujet(s)
Angiographie cérébrale/instrumentation , Angiographie cérébrale/méthodes , Infarctus du territoire de l'artère cérébrale moyenne/imagerie diagnostique , Imagerie de perfusion/instrumentation , Imagerie de perfusion/méthodes , Tomodensitométrie/instrumentation , Tomodensitométrie/méthodes , Adulte , Sujet âgé , Sujet âgé de 80 ans ou plus , Études de faisabilité , Femelle , Humains , Traitement d'image par ordinateur/méthodes , Angiographie par résonance magnétique/instrumentation , Angiographie par résonance magnétique/méthodes , Mâle , Adulte d'âge moyen , Projets pilotes , Sensibilité et spécificité
7.
Fortschr Neurol Psychiatr ; 82(3): 149-54, 2014 Mar.
Article de Allemand | MEDLINE | ID: mdl-24615586

RÉSUMÉ

Immunologically mediated heparin-induced thrombocytopenia (HIT) is a thrombotic disease caused by antibodies occurring after heparin exposure. Thrombocytopenia occurs within a few days after heparin exposure, about half of HIT-patients develop venous or arterial thrombotic complications. Neurological complications of HIT are mainly ischaemic stroke and sinus vein thrombosis. To ensure the primary clinical diagnosis functional and immunological assays for antibody detection are available. The probability for the occurrence of HIT depends on the nature of heparin employed (LMWH vs. UFH) and individual patient characteristics such as gender and primary disease (medical vs. surgical patients). In the case of suspected HIT heparin administration should be discontinued immediately and replaced by an alternative anticoagulation to prevent the expansion or development of further thrombotic complications. Herein we report a case of a patient suffering from HIT-associated embolic cerebral ischaemic stroke.


Sujet(s)
Anticoagulants/effets indésirables , Angiopathies intracrâniennes/étiologie , Héparine/effets indésirables , Thrombopénie/complications , Thrombopénie/immunologie , Sujet âgé , Anticorps/analyse , Anticorps/immunologie , Anticoagulants/composition chimique , Encéphalopathie ischémique/étiologie , Angiopathies intracrâniennes/épidémiologie , Échocardiographie transoesophagienne , Héparine/composition chimique , Héparine bas poids moléculaire/effets indésirables , Héparine bas poids moléculaire/usage thérapeutique , Humains , Thrombose intracrânienne/étiologie , Thrombose intracrânienne/prévention et contrôle , Mâle , Thromboses des sinus intracrâniens/étiologie , Accident vasculaire cérébral/étiologie , Thrombopénie/induit chimiquement
8.
Clin Neuroradiol ; 23(4): 285-92, 2013 Dec.
Article de Anglais | MEDLINE | ID: mdl-23525670

RÉSUMÉ

BACKGROUND: Temporary balloon test occlusion (BTO) might be performed prior to procedures in which occlusion of the internal carotid artery (ICA) might be necessary. We tested the hypothesis that parametric color coding (PCC) of angiographic series (digital subtraction angiography (DSA)) along with the assessment of cerebral blood volume (CBV) in the angiography suite would simplify and enhance the identification of candidates who are most likely to tolerate occlusion. MATERIALS AND METHODS: Fifteen patients underwent angiographic series (DSA) and perfusion imaging before and during BTO. Pre- and postocclusion DSA acquisitions were evaluated for venous delay by conventional methods ("eye balling") and by PCC measurements. Comparison of CBV values between the left and right hemisphere in 6 defined regions was performed. RESULTS: Values of venous delay by eye balling and PCC showed a high correlation (r = 0.87, p < 0.01). Bland-Altman plot indicated slightly lower values (-0.05 s) by the PCC method. One of the 15 patients developed an asymmetrical CBV map with an increase in CBV of more than one standard deviation in 3 of the 6 regions of interest (ROIs). Acquisition of angiographic series and perfusion imaging did not prolong the test occlusion time. CONCLUSION: PCC and CBV mapping are feasible during BTO. The use of PCC seems to simplify the ability to measure changes in venous filling delay. Perfusion imaging may show an increase in CBV in patients reaching the limits of cerebral autoregulation. These patients may be at risk for delayed infarction, even though they seem to tolerate temporary occlusion, and could be unsuitable candidates for permanent ICA occlusion.


Sujet(s)
Angiographie de soustraction digitale/méthodes , Occlusion par ballonnet/méthodes , Artère carotide interne/imagerie diagnostique , Sténose carotidienne/imagerie diagnostique , Sténose carotidienne/thérapie , Interprétation d'images radiographiques assistée par ordinateur/méthodes , Radiographie interventionnelle/méthodes , Angiographie cérébrale/méthodes , Couleur , Femelle , Humains , Mâle , Adulte d'âge moyen , Projets pilotes , Reproductibilité des résultats , Sensibilité et spécificité
9.
AJNR Am J Neuroradiol ; 33(11): 2068-73, 2012 Dec.
Article de Anglais | MEDLINE | ID: mdl-22743639

RÉSUMÉ

BACKGROUND AND PURPOSE: CTA-like datasets can be reconstructed from whole-brain VPCTA. The aim of our study was to compare VPCTA with CTA for detection of intracranial stenosis and occlusion in stroke patients. Omitting CTA from stroke CT could reduce radiation dose. MATERIALS AND METHODS: One hundred sixty-three patients were included in this retrospective analysis. Inclusion criterion was suspected stroke within 4.5 hours after onset of symptoms. All examinations were performed on a 128-section multidetector CT scanner. Axial, coronal, and sagittal maximum intensity projections were reconstructed from CTA and from peak arterial phase of VPCTA. Images were scored for quality and presence of intracranial stenosis >50% or occlusion. For statistical analysis, the Wilcoxon signed-rank test and Fisher exact test were used, with a 2-tailed P value of .05 or less for statistical significance. RESULTS: Average image quality was superior in CTA (P < .05). However, image quality dichotomized for diagnostic significance was without difference between CTA and VPCTA (P > .05). Comparative statistical analysis revealed no significant difference for detection of intracranial stenosis and occlusion between CTA and VPCTA (P > .05). Substitution of intracranial CTA by VPCTA would lower radiation dose by 0.5 mSv. CONCLUSIONS: VPCTA is suited to assess the intracranial vasculature in patients with stroke and might have the potential to decrease radiation dose by substituting for intracranial CTA in stroke CT. Additional studies are necessary to further evaluate potential benefits of the dynamic nature of VPCTA.


Sujet(s)
Angiographie cérébrale/méthodes , Artères cérébrales/imagerie diagnostique , Imagerie tridimensionnelle/méthodes , Accident vasculaire cérébral/imagerie diagnostique , Tomodensitométrie/méthodes , Sujet âgé , Volume sanguin , Mesure du volume sanguin/méthodes , Artères cérébrales/physiopathologie , Angiopathies intracrâniennes/imagerie diagnostique , Angiopathies intracrâniennes/physiopathologie , Femelle , Humains , Mâle , Reproductibilité des résultats , Sensibilité et spécificité
11.
Eur J Neurol ; 19(11): 1477-81, 2012 Nov.
Article de Anglais | MEDLINE | ID: mdl-22221591

RÉSUMÉ

BACKGROUND AND PURPOSE: Clinical data on sex differences in perihemorrhagic edema (PHE) after intracerebral hemorrhage (ICH) are lacking. METHODS: Patients with spontaneous supratentorial ICH who had received standard conservative treatment were identified retrospectively. PHE development was assessed over a 14-day period on follow-up CT scans (days 1, 2-4, 5-7, 8-11, and 12-14). ICH and PHE volumes were assessed semiautomatically and compared between men and women. RESULTS: A total of 387 patients (233 men) were included. Starting at days 2-4, women showed lower PHE values (P < 0.05; days 2-4, 8-11) or a trend toward significance (P ≤ 0.1; days 5-7, 12-14). CONCLUSIONS: Female sex may predict lower PHE volumes.


Sujet(s)
Oedème cérébral/imagerie diagnostique , Oedème cérébral/étiologie , Hémorragie cérébrale/complications , Hémorragie cérébrale/imagerie diagnostique , Caractères sexuels , Sujet âgé , Femelle , Humains , Mâle , Études rétrospectives , Tomodensitométrie
12.
AJNR Am J Neuroradiol ; 33(4): 618-25, 2012 Apr.
Article de Anglais | MEDLINE | ID: mdl-22207301

RÉSUMÉ

BACKGROUND AND PURPOSE: A new FPCT application offers the possibility of perfusion (FPCT CBV) and parenchymal (FPCT) imaging within the angiography suite. We tested the hypothesis that findings in FPCT CBV and FPCT would correlate with those obtained using MSCT and PCT. MATERIALS AND METHODS: In 16 patients with acute MCA occlusion, FPCT CBV was performed immediately posttreatment. The volume of tissue having abnormal CBV values was determined by FPCT CBV and PCT images. Stroke volume on follow-up MSCT was determined, CBV values in the effected parenchyma were measured, and FPCT images were reviewed. RESULTS: In 6 cases, we found a FPCT CBV value identical or higher (hyperemia) in comparison with the contralateral side. In 10 cases, we found CBV lesions with values lower (oligemia) than the contralateral brain tissue. We found a high correlation of CBV lesion volume on FPCT CBV images to stroke volume on follow-up MSCT (r = 0.9, P < .05) in the oligemia group. Absolute FPCT CBV and PCT CBV values were comparable and showed good correlation (r = 0.9, P < .05). In 8 patients, contrast medium extravasation was visible. CONCLUSIONS: The new FPCT application allows assessment of CBV in acute stroke patients. Our initial results indicate that these measurements may predict final infarct volume. The ability to assess this key parameter of cerebral perfusion within the angiographic suite may improve the management of these patients.


Sujet(s)
Mesure du volume sanguin/instrumentation , Angiographie cérébrale/instrumentation , Circulation cérébrovasculaire , Anévrysme intracrânien/imagerie diagnostique , Anévrysme intracrânien/physiopathologie , Tomodensitométrie/instrumentation , Sujet âgé , Vitesse du flux sanguin , Mesure du volume sanguin/méthodes , Conception d'appareillage , Analyse de panne d'appareillage , Études de faisabilité , Femelle , Humains , Anévrysme intracrânien/chirurgie , Mâle , Projets pilotes , Tomodensitométrie/méthodes , Résultat thérapeutique
13.
AJNR Am J Neuroradiol ; 32(9): 1632-9, 2011 Oct.
Article de Anglais | MEDLINE | ID: mdl-21816919

RÉSUMÉ

BACKGROUND AND PURPOSE: CT perfusion data sets are commonly acquired using a temporal resolution of 1 image per second. To limit radiation dose and allow for increased spatial coverage, the reduction of temporal resolution is a possible strategy. The aim of this study was to evaluate the effect of reduced temporal resolution in CT perfusion scans with regard to color map quality, quantitative perfusion parameters, ischemic lesion extent, and clinical decision-making when using DC and MS algorithms. MATERIALS AND METHODS: CTP datasets from 50 patients with acute stroke were acquired with a TR of 1 second. Two-second TR datasets were created by removing every second image. Various perfusion parameters (CBF, CBV, MTT, TTP, TTD) and color maps were calculated by using identical data-processing settings for 2-second and 1-second TR. Color map quality, quantitative region-of-interest-based perfusion measurements, and TAR/NVT lesions (indicated by CBF/CBV mismatch) derived from the 2-second and 1-second processed data were statistically compared. RESULTS: Color map quality was similar for 2-second versus 1-second TR when using DC and was reduced when using MS. Regarding quantitative values, differences between 2-second and 1-second TR datasets were statistically significant by using both algorithms. Using DC, corresponding tissue-at-risk lesions were slightly smaller at 2-second versus 1-second TR (P < .05), whereas corresponding NVT lesions showed excellent agreement. With MS, corresponding tissue-at-risk lesions showed excellent agreement but more artifacts, whereas NVT lesions were larger (P < .001) compared with 1-second TR. Therapeutic decisions would have remained the same in all patients. CONCLUSIONS: CTP studies obtained with 2-second TR are typically still diagnostic, and the same therapy would have been provided. However, with regard to perfusion quantitation and image-quality-based confidence, our study indicates that 1-second TR is preferable to 2-second TR.


Sujet(s)
Encéphalopathie ischémique/imagerie diagnostique , Imagerie de perfusion/méthodes , Accident vasculaire cérébral/imagerie diagnostique , Tomodensitométrie/méthodes , Maladie aigüe , Sujet âgé , Algorithmes , Bases de données factuelles/statistiques et données numériques , Femelle , Humains , Mâle , Adulte d'âge moyen , Dose de rayonnement , Études rétrospectives
15.
Minerva Anestesiol ; 77(3): 371-4, 2011 Mar.
Article de Anglais | MEDLINE | ID: mdl-21364501

RÉSUMÉ

Development of space-occupying edema in patients with severe Herpes simplex virus encephalitis is a major factor for high morbidity and mortality. Conventional intracranial pressure-lowering modalities are limited and more aggressive treatment options for such patients have rarely been described. This article reports on a HIV-positive patient with Herpes simplex type 2 encephalitis and elevated intracranial pressure refractory to medical therapy. Induced moderate hypothermia of 33 °C resulted in fast and sustained control of intracranial pressure. After three months, the patient had a fairly good functional outcome with a Glasgow Outcome Scale score of 4.


Sujet(s)
Encéphalite à herpès simplex/thérapie , Hypothermie provoquée , Encéphale/anatomopathologie , Oedème cérébral/étiologie , Oedème cérébral/anatomopathologie , Oedème cérébral/physiopathologie , Imagerie par résonance magnétique de diffusion , Encéphalite à herpès simplex/anatomopathologie , Échelle de suivi de Glasgow , Infections à VIH/complications , Humains , Hypertension intracrânienne/étiologie , Hypertension intracrânienne/thérapie , Pression intracrânienne/physiologie , Imagerie par résonance magnétique , Mâle , Adulte d'âge moyen , Crises épileptiques/étiologie
16.
AJNR Am J Neuroradiol ; 31(9): 1690-8, 2010 Oct.
Article de Anglais | MEDLINE | ID: mdl-20581066

RÉSUMÉ

BACKGROUND AND PURPOSE: PCT postprocessing commonly uses either the MS or a variant of the DC approach for modeling of voxel-based time-attenuation curves. There is an ongoing discussion about the respective merits and limitations of both methods, frequently on the basis of theoretic reasoning or simulated data. We performed a qualitative and quantitative comparison of DC and MS by using identical source datasets and preprocessing parameters. MATERIALS AND METHODS: From the PCT data of 50 patients with acute ischemic stroke, color maps of CBF, CBV, and various temporal parameters were calculated with software implementing both DC and MS algorithms. Color maps were qualitatively categorized. Quantitative region-of-interest-based measurements were made in nonischemic GM and WM, suspected penumbra, and suspected infarction core. Qualitative results, quantitative results, and PCT lesion sizes from DC and MS were statistically compared. RESULTS: CBF and CBV color maps based on DC and MS were of comparably high quality. Quantitative CBF and CBV values calculated by DC and MS were within the same range in nonischemic regions. In suspected penumbra regions, average CBF(DC) was lower than CBF(MS). In suspected infarction core regions, average CBV(DC) was similar to CBV(MS). Using adapted tissue-at-risk/nonviable-tissue thresholds, we found excellent correlation of DC and MS lesion sizes. CONCLUSIONS: DC and MS yielded comparable qualitative and quantitative results. Lesion sizes indicated by DC and MS showed excellent agreement when using adapted thresholds. In all cases, the same therapy decision would have been made.


Sujet(s)
Algorithmes , Encéphalopathie ischémique/complications , Encéphalopathie ischémique/imagerie diagnostique , Imagerie de perfusion/méthodes , Interprétation d'images radiographiques assistée par ordinateur/méthodes , Accident vasculaire cérébral/imagerie diagnostique , Accident vasculaire cérébral/étiologie , Tomodensitométrie/méthodes , Adulte , Sujet âgé , Sujet âgé de 80 ans ou plus , Femelle , Humains , Mâle , Adulte d'âge moyen , Amélioration d'image radiographique/méthodes , Reproductibilité des résultats , Sensibilité et spécificité
17.
Clin Radiol ; 65(6): 440-6, 2010 Jun.
Article de Anglais | MEDLINE | ID: mdl-20451010

RÉSUMÉ

AIM: To evaluate the impact of bone subtraction computed tomography angiography (BS-CTA) for the assessment of transcranial arteries in comparison with standard CTA (S-CTA) without bone removal and time-of-flight magnetic resonance angiography (TOF-MRA). MATERIALS AND METHODS: Cranial unenhanced CT and S-CTA were performed in 53 patients with suspected cerebrovascular disease. BS-CTA datasets were reconstructed from the S-CTA and unenhanced CT source images. TOF-MRA was performed within 24h after CTA on a 1.5 T MRI system. Two radiologists, in consensus, evaluated the segments of the internal carotid artery (C2-C7), the vertebral artery (V4), and the basilar artery for the degree of stenosis. A five-step scale (0-49, 50-69, 70-89, 90-99% and occlusion) for the degree of stenosis was applied for all segments. Wilcoxon's signed rank test was used for statistical analysis. RESULTS: Seven hundred and fifty vessel segments (ICA:636, VA:106, BA:53) were analysed. The degree of stenosis on S-CTA was consistent with TOF-MRA in all segments. BS-CTA showed a trend towards higher stenosis scores in cases of calcified plaques compared to S-CTA (p=0.11) and TOF-MRA (p=0.09), which was not statistically significant. In transcranial segments, BS-CTA revealed equivalent scores compared to S-CTA and TOF-MRA (p=0.25; p=0.20). CONCLUSION: BS-CTA produced similar results to TOF-MRA and S-CTA and can be applied as a non-invasive imaging method for the transcranial arteries. However, BS-CTA shows a trend towards overestimation of the degree of stenosis.


Sujet(s)
Angiographie de soustraction digitale/méthodes , Artères cérébrales/imagerie diagnostique , Angiopathies intracrâniennes/imagerie diagnostique , Angiographie par résonance magnétique/méthodes , Crâne/imagerie diagnostique , Angiographie cérébrale/méthodes , Artères cérébrales/anatomopathologie , Angiopathies intracrâniennes/anatomopathologie , Femelle , Humains , Mâle , Adulte d'âge moyen , Reproductibilité des résultats , Tomodensitométrie/méthodes
18.
AJNR Am J Neuroradiol ; 31(8): 1462-9, 2010 Sep.
Article de Anglais | MEDLINE | ID: mdl-20378700

RÉSUMÉ

BACKGROUND AND PURPOSE: The viability of both brain parenchyma and vascular anatomy is important in estimating the risk and potential benefit of revascularization in patients with acute cerebral ischemia. We tested the hypothesis that when used in conjunction with IV contrast, FD-CT imaging would provide both anatomic and physiologic information that would correlate well with that obtained by using standard multisection CT techniques. MATERIALS AND METHODS: Imaging of brain parenchyma (FD-CT), cerebral vasculature (FD-CTA), and cerebral blood volume (FD-CBV) was performed in 10 patients. All patients also underwent conventional multisection CT, CTA, CTP (including CBV, CTP-CBV), and conventional catheter angiography. Correlation of the corresponding images was performed by 2 experienced neuroradiologists. RESULTS: There was good correlation of the CBV color maps and absolute values between FD-CBV and CTP-CBV (correlation coefficient, 0.72; P < .001). The Bland-Altman test showed a mean difference of CBV values between FD-CT and CTP-CBV of 0.04 ± 0.55 mL/100 mL. All vascular lesions identified with standard CTA were also visualized with FD-CTA. Visualization of brain parenchyma by using FD-CT was poor compared with that obtained by using standard CT. CONCLUSIONS: Both imaging of the cerebral vasculature and measurements of CBV by using FD-CT are feasible. The resulting vascular images and CBV measurements compared well with ones made by using standard CT techniques. The ability to measure CBV and also visualize cerebral vasculature in the angiography suite may offer significant advantages in the management of patients. FD-CT is not yet equivalent to CT for imaging of brain parenchyma.


Sujet(s)
Encéphalopathie ischémique/imagerie diagnostique , Encéphale/vascularisation , Encéphale/imagerie diagnostique , Angiographie cérébrale/méthodes , Tomodensitométrie/méthodes , Maladie aigüe , Sujet âgé , Sujet âgé de 80 ans ou plus , Volume sanguin , Circulation cérébrovasculaire , Produits de contraste , Études de faisabilité , Femelle , Humains , Traitement d'image par ordinateur/méthodes , Mâle , Adulte d'âge moyen , Projets pilotes , Études prospectives
20.
Acta Neurol Scand ; 120(1): 68-71, 2009 Jul.
Article de Anglais | MEDLINE | ID: mdl-19053954

RÉSUMÉ

BACKGROUND: The first ever diagnosis of multiple sclerosis (MS) requires consideration of both diagnostic criteria and differential diagnosis. Clinicians are particularly challenged by rare conditions which may mimic MS symptoms and relapses. CASE REPORT: We report the case of a young female patient who presented with relapsing left hemispheric symptoms that were highly suspicious of MS but were caused by an idiopathic occlusive angiopathy of the circle of Willis. CONCLUSION: Occlusive disease of the great cerebral arteries in young patients is a rare but important differential diagnosis of MS. It has to be considered in patients presenting with the first symptoms suspicious of MS as substantial treatment consequences will arise.


Sujet(s)
Artériopathies cérébrales/diagnostic , Cercle artériel du cerveau/physiopathologie , Sclérose en plaques/diagnostic , Angiographie cérébrale , Diagnostic différentiel , Femelle , Humains , Imagerie par résonance magnétique , Jeune adulte
SÉLECTION CITATIONS
DÉTAIL DE RECHERCHE