Your browser doesn't support javascript.
loading
Montrer: 20 | 50 | 100
Résultats 1 - 20 de 28
Filtrer
1.
Pulm Circ ; 14(3): e12409, 2024 Jul.
Article de Anglais | MEDLINE | ID: mdl-38962183

RÉSUMÉ

Balloon pulmonary angioplasty (BPA) is beneficial for patients with chronic thromboembolic pulmonary disease (CTEPD) with pulmonary hypertension (PH). However, the clinical benefit of BPA for the patients with CTEPD without PH remains unknown. In this study, we aimed to evaluate the efficacy, safety, and long-term outcomes of BPA in patients with CTEPD without PH. We retrospectively analyzed the data from 84 CTEPD patients with mean pulmonary artery pressure (mPAP) < 25 mmHg and 39 CTEPD patients with mPAP ≤ 20 mmHg (without PH). Among the 39 patients with CTEPD without PH, 14 underwent BPA (BPA-treated group), and the remaining 25 received no treatment (untreated group). In the patients with CTEPD without PH, BPA led to improvements in symptoms, pulmonary vascular resistance (3.6 ± 1.6 to 2.6 ± 1.1 Wood units, p < 0.001), peak oxygen consumption (16.1 ± 4.0 to 18.8 ± 4.3 mL/kg/min, p = 0.033), minute ventilation versus carbon dioxide production slope (41.4 ± 12.2 to 35.1 ± 6.7, p = 0.026), and mPAP/cardiac output slope (7.0 ± 2.6 to 4.4 ± 2.0 mmHg/L/min, p = 0.004) and facilitated the discontinuation of home oxygenation therapy, with no serious complications. Kaplan-Meier analysis showed no significant difference in all-cause mortality between the untreated and BPA-treated groups. BPA may be a safe treatment option for the patients with CTEPD without PH that can alleviate symptoms, improve exercise capacity, and facilitate weaning from home oxygen therapy. Further prospective randomized trials are needed to confirm these findings.

2.
Thromb J ; 22(1): 60, 2024 Jul 10.
Article de Anglais | MEDLINE | ID: mdl-38987750

RÉSUMÉ

BACKGROUND: Direct oral anticoagulants are the established drugs for treating pulmonary thromboembolism. The advantage of direct oral anticoagulants over conventional therapy for clot lysis and right ventricular unloading in the acute phase remains unclear. This study aimed to evaluate the effect of acute treatment with direct oral anticoagulants on clot dissolution and right ventricular unloading in intermediate high-risk pulmonary thromboembolism. METHODS: Thirty patients with intermediate high-risk pulmonary thromboembolism admitted between November 2012 and December 2018 were included; 21 and 9 were treated with direct oral anticoagulants and conventional therapy, respectively. We compared the efficacy of clot dissolution and right ventricular unloading for intermediate high-risk pulmonary thromboembolism between direct oral anticoagulant and conventional therapy in the acute phase. Efficacy was assessed by computed tomography obstruction index, right/left ventricular ratio, and brain natriuretic peptide levels between baseline and at discharge. RESULTS: Computed tomography obstruction index, right ventricular/left ventricular ratio, and brain natriuretic peptide levels were significantly lower at discharge than at admission in both groups. The rate of improvement in computed tomography obstruction index was significantly higher in the direct oral anticoagulant therapy group than in the conventional therapy group (64 ± 15% vs. 47 ± 16%; p = 0.01). There were no significant differences in the rate of improvement in right ventricular/ left ventricular ratio and brain natriuretic peptide levels between the two groups. CONCLUSIONS: Compared with conventional therapy, direct oral anticoagulants significantly reduced pulmonary artery clot burden conventional therapy in the acute treatment of intermediate high-risk pulmonary thromboembolism.

3.
Int J Cardiol ; : 132343, 2024 Jul 06.
Article de Anglais | MEDLINE | ID: mdl-38977227

RÉSUMÉ

BACKGROUND: Vessel injury is a common complication during balloon pulmonary angioplasty (BPA). For persistent hemoptysis, gelatin sponge embolization (GSE) is considered, but its impact on subsequent perfusion in embolized vessels remains unknown. This study explores the feasibility of revascularization in vessels post-GSE. METHODS: We included 64 vessels from 50 patients with chronic thromboembolic pulmonary hypertension who experienced hemoptysis during BPA in 2012-2023. Twenty-four vessels were treated conservatively (conservative group), while 40 were treated with GSE for persistent hemoptysis or desaturation despite conservative treatment (GSE group). We assessed hemoptysis-related parameters, perfusion of injured vessels pre- and post-treatment, and hemodynamic parameters through multiple BPA sessions. RESULTS: Hemoptysis resolved immediately after the procedure in 67% of patients, including 70% of those in the GSE group, and all cases resolved by the next day. Of 37 embolized vessels, 41% showed spontaneous perfusion improvement in subsequent sessions. BPA was reperformed in 22 embolized vessels, with 86% showing further improvement, resulting in total 70% of embolized vessels finally showing improvement in perfusion. In both groups, clinical and hemodynamic parameters significantly improved after BPA. CONCLUSIONS: Perfusion of embolized vessels improved after GSE, suggesting that GSE is safe for the treatment of severe persistent hemoptysis after conservative treatment.

4.
Article de Anglais | MEDLINE | ID: mdl-38796803

RÉSUMÉ

PURPOSE: This study examines the hepatic extracellular volume fraction (ECV) disparity between the left and right lobes (ECV_left and ECV_right) in patients with chronic thromboembolic pulmonary hypertension (CTEPH), its association with right heart catheterization (RHC) metrics, and with intolerance to increased pulmonary hypertension (PH)-targeted medication dosages. METHODS: We retrospectively analyzed 72 CTEPH-diagnosed patients who underwent equilibrium-phase abdominal dual-energy CT (DECT) and RHC. Hepatic ECVs, derived from DECT's iodine maps using circular regions of interest in the liver and aorta, were correlated with RHC parameters via Spearman's rank correlation and lobe differences through the Wilcoxon signed-rank test. Logistic regression assessed cases with ECV_left exceeding ECV_right by > 0.05, while receiver operating characteristic curve analysis gauged ECVs' predictive power for medication intolerance. RESULTS: Of the 72 patients (57 females; median age 69), ECV_total (0.24, IQR 0.20-0.27) moderately correlated with RHC parameters (rs = 0.28, -0.24, 0.3 for mean pulmonary arterial pressure, cardiac index [CI], and pulmonary vascular resistance index, respectively). ECV_left significantly surpassed ECV_right (0.25 vs. 0.22, p < 0.001), with a greater ECV_left by > 0.05 indicating notably lower CI (p < 0.001). In 27 patients on PH medication, ECV_left effectively predicted medication intolerance (AUC = 0.84). CONCLUSION: In CTEPH patients, hepatic ECV correlated with RHC metrics, where elevated left lobe ECV suggested reduced CI and potential medication intolerance.

5.
J Cardiovasc Electrophysiol ; 34(6): 1473-1476, 2023 06.
Article de Anglais | MEDLINE | ID: mdl-37222178

RÉSUMÉ

BACKGROUND: Atrial lead perforation may lead to pneumopericardium or pneumothorax within a few days of device implantation. METHODS AND RESULTS: We report a case of atrial lead perforation 6 years after cardiac resynchronization therapy implantation, which resulted in pneumopericardium and pneumothorax. CONCLUSION: Although pneumopericardium caused by atrial lead perforation can spontaneously resolve with conservative treatment, as it did in this case, treatment should be decided based on the patient's general condition and lead performance.


Sujet(s)
Fibrillation auriculaire , Lésions traumatiques du coeur , Pacemaker , Pneumopéricarde , Pneumothorax , Humains , Pacemaker/effets indésirables , Fibrillation auriculaire/complications , Pneumopéricarde/imagerie diagnostique , Pneumopéricarde/étiologie , Pneumopéricarde/thérapie , Pneumothorax/imagerie diagnostique , Pneumothorax/étiologie , Pneumothorax/thérapie , Lésions traumatiques du coeur/imagerie diagnostique , Lésions traumatiques du coeur/étiologie , Lésions traumatiques du coeur/thérapie
6.
Acad Radiol ; 30(11): 2505-2513, 2023 Nov.
Article de Anglais | MEDLINE | ID: mdl-36868878

RÉSUMÉ

RATIONALE AND OBJECTIVES: Coronary inflammation related to high-risk hemorrhagic plaques can be captured by the perivascular fat attenuation index (FAI) using coronary computed tomography angiography (CCTA). Since the FAI is susceptible to image noise, we believe deep learning (DL)-based post hoc noise reduction can improve diagnostic capability. We aimed to assess the diagnostic performance of the FAI in DL-based denoised high-fidelity CCTA images compared with coronary plaque magnetic resonance imaging (MRI) delivered high-intensity hemorrhagic plaques (HIPs). MATERIALS AND METHODS: We retrospectively reviewed 43 patients who underwent CCTA and coronary plaque MRI. We generated high-fidelity CCTA images by denoising the standard CCTA images using a residual dense network that supervised the denoising task by averaging three cardiac phases with nonrigid registration. We measured the FAIs as the mean CT value of all voxels (range of -190 to -30 HU) located within a radial distance from the outer proximal right coronary artery wall. The diagnostic reference standard was defined as HIPs (high-risk hemorrhagic plaques) using MRI. The diagnostic performance of the FAI in the original and denoised images was assessed using receiver operating characteristic curves. RESULTS: Of 43 patients, 13 had HIPs. The denoised CCTA improved the area under the curve (0.89 [95% confidence interval (CI) 0.78-0.99]) of the FAI compared with that in the original image (0.77 [95% CI, 0.62-0.91], p = 0.008). The optimal cutoff value for predicting HIPs in denoised CCTA was -69 HU with 0.85 (11/13) sensitivity, 0.79 (25/30) specificity, and 0.80 (36/43) accuracy. CONCLUSION: DL-based denoised high-fidelity CCTA improved the AUC and specificity of the FAI for predicting HIPs.

7.
Eur Radiol ; 33(7): 4688-4697, 2023 Jul.
Article de Anglais | MEDLINE | ID: mdl-36809433

RÉSUMÉ

OBJECTIVES: To determine the optimal inversion time (TI) from Look-Locker scout images using a convolutional neural network (CNN) and to investigate the feasibility of correcting TI using a smartphone. METHODS: In this retrospective study, TI-scout images were extracted using a Look-Locker approach from 1113 consecutive cardiac MR examinations performed between 2017 and 2020 with myocardial late gadolinium enhancement. Reference TI null points were independently determined visually by an experienced radiologist and an experienced cardiologist, and quantitatively measured. A CNN was developed to evaluate deviation of TI from the null point and then implemented in PC and smartphone applications. Images on 4 K or 3-megapixel monitors were captured by a smartphone, and CNN performance on each monitor was determined. Optimal, undercorrection, and overcorrection rates using deep learning on the PC and smartphone were calculated. For patient analysis, TI category differences in pre- and post-correction were evaluated using the TI null point used in late gadolinium enhancement imaging. RESULTS: For PC, 96.4% (772/749) of images were classified as optimal, with under- and overcorrection rates of 1.2% (9/749) and 2.4% (18/749), respectively. For 4 K images, 93.5% (700/749) of images were classified as optimal, with under- and overcorrection rates of 3.9% (29/749) and 2.7% (20/749), respectively. For 3-megapixel images, 89.6% (671/749) of images were classified as optimal, with under- and overcorrection rates of 3.3% (25/749) and 7.0% (53/749), respectively. On patient-based evaluations, subjects classified as within optimal range increased from 72.0% (77/107) to 91.6% (98/107) using the CNN. CONCLUSIONS: Optimizing TI on Look-Locker images was feasible using deep learning and a smartphone. KEY POINTS: • A deep learning model corrected TI-scout images to within optimal null point for LGE imaging. • By capturing the TI-scout image on the monitor with a smartphone, the deviation of the TI from the null point can be immediately determined. • Using this model, TI null points can be set to the same degree as that by an experienced radiological technologist.


Sujet(s)
Produits de contraste , Apprentissage profond , Humains , Produits de contraste/pharmacologie , Gadolinium , Études rétrospectives , Imagerie par résonance magnétique/méthodes , Ordiphone
10.
Radiology ; 305(1): 82-91, 2022 10.
Article de Anglais | MEDLINE | ID: mdl-35762889

RÉSUMÉ

Background To improve myocardial delayed enhancement (MDE) CT, a deep learning (DL)-based post hoc denoising method supervised with averaged MDE CT data was developed. Purpose To assess the image quality of denoised MDE CT images and evaluate their diagnostic performance by using late gadolinium enhancement (LGE) MRI as a reference. Materials and methods MDE CT data obtained by averaging three acquisitions with a single breath hold 5 minutes after the contrast material injection in patients from July 2020 to October 2021 were retrospectively reviewed. Preaveraged images obtained in 100 patients as inputs and averaged images as ground truths were used to supervise a residual dense network (RDN). The original single-shot image, standard averaged image, RDN-denoised original (DLoriginal) image, and RDN-denoised averaged (DLave) image of holdout cases were compared. In 40 patients, the CT value and image noise in the left ventricular cavity and myocardium were assessed. The segmental presence of MDE in the remaining 40 patients who underwent reference LGE MRI was evaluated. The sensitivity, specificity, and accuracy of each type of CT image and the improvement in accuracy achieved with the RDN were assessed using odds ratios (ORs) estimated with the generalized estimation equation. Results Overall, 180 patients (median age, 66 years [IQR, 53-74 years]; 107 men) were included. The RDN reduced image noise to 28% of the original level while maintaining equivalence in the CT values (P < .001 for all). The sensitivity, specificity, and accuracy of the original images were 77.9%, 84.4%, and 82.3%, of the averaged images were 89.7%, 87.9%, and 88.5%, of the DLoriginal images were 93.1%, 87.5%, and 89.3%, and of the DLave images were 95.1%, 93.1%, and 93.8%, respectively. DLoriginal images showed improved accuracy compared with the original images (OR, 1.8 [95% CI: 1.2, 2.9]; P = .011) and DLave images showed improved accuracy compared with the averaged images (OR, 2.0 [95% CI: 1.2, 3.5]; P = .009). Conclusion The proposed denoising network supervised with averaged CT images reduced image noise and improved the diagnostic performance for myocardial delayed enhancement CT. © RSNA, 2022 Online supplemental material is available for this article. See also the editorial by Vannier and Wang in this issue.


Sujet(s)
Produits de contraste , Apprentissage profond , Sujet âgé , Gadolinium , Humains , Mâle , Myocarde , Études rétrospectives , Tomodensitométrie/méthodes
11.
Radiol Cardiothorac Imaging ; 4(6): e220111, 2022 Dec.
Article de Anglais | MEDLINE | ID: mdl-36601449

RÉSUMÉ

Purpose: To evaluate the image quality of high-spatial-resolution two-dimensional (2D) late gadolinium enhancement (LGE) cardiac MRI compared with conventional normal-resolution LGE MRI. Materials and Methods: This prospective study included participants suspected of having cardiomyopathy who underwent cardiac MRI between March 2021 and December 2021. Normal-resolution and high-resolution 2D LGE sequences (inversion recovery [IR] and phase-sensitive inversion recovery [PSIR]) were performed at 3 T. Resolution was compared between normal-resolution and high-resolution images obtained in a quality assurance phantom. In vivo image quality and resolution were evaluated qualitatively using a five-point scoring system. Receiver operating characteristic curve analysis was used for LGE detection performance. Border sharpness was assessed with profile curve measurement. The contrast-to-noise ratio (CNR) between hyperenhancement and remote myocardium and LGE detection performance were calculated using normal-resolution IR images as the reference. Results: In total, 120 participants were evaluated (mean age, 56 years ± 17 [SD]; 72 men). Features smaller than 1 mm were detectable only on high-resolution images of the phantom. In vivo, the image resolution score with high-resolution LGE was 4.14-4.24, which was higher than the normal-resolution LGE reference score of 2.99 (P < .05). Border sharpness was higher in high-resolution images (P < .001). Receiver operating characteristic curve analysis revealed no evidence of a difference in LGE detection between normal-resolution and high-resolution images. There was also no evidence of a change in CNR of LGE in IR and PSIR magnitude compared with reference images. Conclusion: Comparison of image quality in 2D high-resolution and normal-resolution LGE cardiac MRI demonstrated the highest resolution for high-resolution IR and high-resolution PSIR magnitude sequences.Keywords: Cartilage Imaging, MRI, Cardiac, Heart, Imaging Sequences, Comparative Studies Supplemental material is available for this article. © RSNA, 2022.

12.
PLoS One ; 16(11): e0260456, 2021.
Article de Anglais | MEDLINE | ID: mdl-34843578

RÉSUMÉ

BACKGROUND: Right ventricular function is an important prognostic marker for pulmonary arterial hypertension. Native T1 mapping using cardiovascular magnetic resonance imaging can characterize the myocardium, but accumulating evidence indicates that T1 values of the septum or ventricular insertion points do not have predictive potential in pulmonary arterial hypertension. We aimed to elucidate whether native T1 values of the right ventricular free wall (RVT1) can predict poor outcomes in patients with pulmonary arterial hypertension. METHODS: This retrospective study included 30 patients with pulmonary arterial hypertension (median age, 45 years; mean pulmonary artery pressure, 41±13 mmHg) and 16 healthy controls (median age, 43 years) who underwent native T1 mapping. RVT1 was obtained from the inferior right ventricular free wall during end systole. RESULTS: Patients with pulmonary arterial hypertension had significantly higher native RVT1 than did controls (1384±74 vs. 1217±57 ms, p<0.001). Compared with T1 values of the septum or ventricular insertion points, RVT1 correlated better with the effective right ventricular elastance index (R = -0.53, p = 0.003), ventricular-arterial uncoupling (R = 0.46, p = 0.013), and serum brain natriuretic peptide levels (R = 0.65, p<0.001). Moreover, the baseline RVT1 was an accurate predictor of the reduced right ventricular ejection fraction at the 12-month follow-up (delta -3%). RVT1 was independently associated with composite events of death or hospitalization from any cause (hazard ratio = 1.02, p = 0.002). CONCLUSIONS: RVT1 was predictive of right ventricular performance and outcomes in patients with pulmonary arterial hypertension. Thus, native T1 mapping in the right ventricular free wall may be an effective prognostic method for pulmonary arterial hypertension.


Sujet(s)
Ventricules cardiaques/physiopathologie , Hypertension artérielle pulmonaire/diagnostic , Adulte , Sujet âgé , Femelle , Ventricules cardiaques/imagerie diagnostique , Humains , Imagerie par résonance magnétique , Mâle , Adulte d'âge moyen , Pronostic , Hypertension artérielle pulmonaire/imagerie diagnostique , Hypertension artérielle pulmonaire/physiopathologie , Études rétrospectives , Débit systolique , Fonction ventriculaire droite
14.
SAGE Open Med Case Rep ; 9: 2050313X211046742, 2021.
Article de Anglais | MEDLINE | ID: mdl-34567556

RÉSUMÉ

Uterine artery pseudoaneurysm is a rare cause of secondary postpartum hemorrhage. Herein, we report a case of uterine artery pseudoaneurysm, with postpartum hemorrhage commencing 22 days after uncomplicated vaginal delivery. Intermittent bleeding occurred during conservative observation. Transvaginal ultrasound color Doppler imaging revealed swollen vascular structures that suggested arteriovenous malformations, and a saccular dilatation of blood vessels. However, it was insufficient to definitively diagnose the condition as pseudoaneurysm. Meanwhile, the three-dimensional computed tomography angiogram was effective in demonstrating a pseudoaneurysm in the uterus, and an absent early venous return sign, leading to the final diagnosis of a pseudoaneurysm. The patient was successfully treated with transarterial embolization using gelatin sponge pledgets. No bleeding or recurrence of the pseudoaneurysm was observed 2 months after embolization.

15.
Ann Vasc Dis ; 14(1): 75-78, 2021 Mar 25.
Article de Anglais | MEDLINE | ID: mdl-33786106

RÉSUMÉ

A 66-year-old man presented with an enlarging abdominal aorta false lumen, after type A aortic dissection repair. Residual entries were located at the left renal artery, abdominal aorta, and left external iliac artery. The patient underwent endovascular aortic repair with left renal artery stenting to close the entries. Completion aortography showed no false lumen flow without an endoleak, and contrast-enhanced computed tomography 1 month after the procedure demonstrated complete false lumen thrombosis. A total endovascular approach is possible for abdominal aneurysmal dilation in chronic aortic dissection when all entries can be closed using a one-stage procedure with stent grafts and/or branch stenting.

18.
Ann Vasc Dis ; 13(1): 72-75, 2020 Mar 25.
Article de Anglais | MEDLINE | ID: mdl-32273926

RÉSUMÉ

We report the case of a 83-year-old man with aneurysmal sac enlargement after endovascular aneurysm repair for an abdominal aortic aneurysm, despite no overt endoleak (EL) detected on imaging. Occult type II EL was suspected, and treatment was performed. However, the aneurysm continued to enlarge. Thus, we diagnose with type V EL as exclusion diagnosis. We combined an aortic cuff and stent-graft leg to cover the initially inserted stent graft, as a diagnostic treatment for unrefined type IIIb EL. Subsequently, the aneurysm diameter decreased. This technique and concept may be effective for type V EL, which may include another type occult EL.

20.
Ann Vasc Dis ; 13(3): 269-272, 2020 Sep 25.
Article de Anglais | MEDLINE | ID: mdl-33384729

RÉSUMÉ

Objective: To evaluate the clinical utility of the coil in plug (CIP) method in internal iliac artery (IIA) embolization during endovascular aortic aneurysm repair (EVAR) compared to conventional coil embolization (CCE). Material and Methods: From July to December 2018, 10 patients who underwent IIA embolization during EVAR were divided into CIP (n=5) and CCE (n=5) groups. In the CIP technique, the AVP-1 with a size more than 30%-50% of that of the embolized IIA diameter was used. The AVP-1 was deployed in the IIA. Before detachment of the AVP-1, a 2.2-F micro catheter was inserted through the 6-F delivery guiding sheath, and entered the plug. The AVP-1 was then packed with hydrogel micro coils. We compared number of coils used, embolization length, embolization time, volume embolization ratio, and embolic material cost between the groups. Results: The CIP method achieved shorter embolization length with fewer coils used compared to CCE. The CIP method decreased the cost of total embolic materials. Conclusion: The CIP method can achieve shorter embolization length with fewer coils used compared to CCE.

SÉLECTION CITATIONS
DÉTAIL DE RECHERCHE
...