Your browser doesn't support javascript.
loading
Montrer: 20 | 50 | 100
Résultats 1 - 4 de 4
Filtrer
Plus de filtres










Base de données
Gamme d'année
1.
Surg Endosc ; 37(8): 6185-6196, 2023 08.
Article de Anglais | MEDLINE | ID: mdl-37165173

RÉSUMÉ

BACKGROUND: Gastrectomy with extended (D2) lymphadenectomy is considered standard of care for gastric cancer to provide the best possible outcomes and pathologic staging. However, D2 gastrectomy is a technically demanding operation and reported to be associated with increased complications and mortality. Application of sentinel lymph node (SLN) concept in gastric cancer has the potential to reduce patient morbidity; however, SLN techniques are not established for gastrectomy, in part due to lack of practical tracers. An effective and convenient tracer with enhanced SLN accumulation is critically needed. METHODS: Mannose-labelled magnetic tracer 'FerroTrace' and fluorescent dye indocyanine green (ICG) were injected laparoscopically into the stomach submucosa of 8 healthy swine under general anaesthesia. Intraoperative fluorescence imaging was used to highlight draining lymphatic pathways containing ICG, while preoperative T2-weighted MRI and ex vivo magnetometer probe measurements were used to identify nodes containing FerroTrace. Lymphadenectomy was performed either robotically (n = 2) or via laparotomy (n = 6). RESULTS: Mixing ICG and FerroTrace ensured concurrence of fluorescent and magnetic signals in SLNs. An initial trial with robotic dissection removed all magnetic LNs (n = 4). In the subsequent laparotomy study that targeted all ICG-LNs based on intraoperative fluorescence imaging, dissection removed an average of 4.7 ± 1.2 fluorescent, and 2.0 ± 1.3 magnetic LNs per animal. Both MRI and magnetometer detected 100% of SLNs (n = 7). FerroTrace demonstrated high specificity to SLNs, which contained 76 ± 30% of total lymphotropic iron, and 88 ± 20 % of the overall magnetometer signal. CONCLUSIONS: Through utilisation of this dual tracer approach, SLNs were identified via preoperative MRI, visualised intraoperatively with fluorescence imaging, and confirmed with a magnetometer. This combination pairs the sensitivity of ICG with SLN-specific FerroTrace and can be used for reliable SLN detection in gastric cancer, with potential applications in neoadjuvant therapy.


Sujet(s)
Nanoparticules de magnétite , Noeud lymphatique sentinelle , Tumeurs de l'estomac , Animaux , Suidae , Noeud lymphatique sentinelle/imagerie diagnostique , Noeud lymphatique sentinelle/chirurgie , Noeud lymphatique sentinelle/anatomopathologie , Vert indocyanine , Biopsie de noeud lymphatique sentinelle/méthodes , Mannose , Tumeurs de l'estomac/imagerie diagnostique , Tumeurs de l'estomac/chirurgie , Tumeurs de l'estomac/anatomopathologie , Agents colorants , Lymphadénectomie , Colorants fluorescents , Noeuds lymphatiques/imagerie diagnostique , Noeuds lymphatiques/chirurgie , Noeuds lymphatiques/anatomopathologie
2.
Head Neck ; 44(12): 2696-2707, 2022 12.
Article de Anglais | MEDLINE | ID: mdl-36082404

RÉSUMÉ

BACKGROUND: Sentinel lymph node biopsy (SLNB) is a staging procedure dependent on accurate mapping of draining lymphatics via tracers. Robot-assisted SLNB enables access to multiple neck levels with a single incision and intraoperative fluorescence guidance to the SLN. METHODS: Lymphatic mapping in swine was done using a magnetic tracer and fluorescent dye, injected into the tongue. MRI preoperatively mapped lymphatic spread of the magnetic tracer. Dissection was performed using a da Vinci Xi robot guided by fluorescence-imaging of the dye. RESULTS: Robot-assisted SLNB was successfully performed in all animals (n = 5). A novel MRI protocol differentiated SLNs (n = 6) from lower echelon nodes (n = 11) based on flow progression. Fluorescence imaging provided valuable intraoperative guidance and correlated with magnetic-positive nodes. CONCLUSIONS: This study demonstrates preclinical feasibility of a robot-assisted approach to SLNB using magnetic and fluorescent tracers in the head and neck, enabling both preoperative mapping and intraoperative guidance.


Sujet(s)
Robotique , Biopsie de noeud lymphatique sentinelle , Animaux , Suidae , Biopsie de noeud lymphatique sentinelle/méthodes , Fluorescence , Études de faisabilité , Vert indocyanine , Colorants fluorescents , Noeuds lymphatiques/imagerie diagnostique , Noeuds lymphatiques/chirurgie , Noeuds lymphatiques/anatomopathologie
3.
Nanomedicine ; 42: 102546, 2022 06.
Article de Anglais | MEDLINE | ID: mdl-35278683

RÉSUMÉ

Sentinel lymph node biopsy in cancers of the head and neck offers demonstrated clinical and diagnostic value, but adoption is limited by concerns about the detrimental consequence to survival of false negative results in a highly curable setting. The aim of this study was to demonstrate potential to overcome this via application of a novel mannose-labeled magnetic iron oxide tracer. In a large animal model, preoperative imaging and intraoperative magnetometer detection were used to identify magnetic lymph nodes. Iron quantification mapped the distribution of tracer within lymphatic levels. Over a 4-week test period, uptake of magnetic tracer in lymph nodes increased in a linear-like fashion, with a substantial percentage of accumulated iron (83%) being retained in the sentinel node. This result indicates a high affinity of mannose-labeled particles to the sentinel node, while providing a means for the magnetometer probe to indicate node status based on intraoperative signal.


Sujet(s)
Nanoparticules de magnétite , Noeud lymphatique sentinelle , Animaux , Fer , Noeuds lymphatiques , Phénomènes magnétiques , Mannose , Noeud lymphatique sentinelle/imagerie diagnostique , Noeud lymphatique sentinelle/chirurgie , Biopsie de noeud lymphatique sentinelle/méthodes
SÉLECTION CITATIONS
DÉTAIL DE RECHERCHE
...