Your browser doesn't support javascript.
loading
Montrer: 20 | 50 | 100
Résultats 1 - 7 de 7
Filtrer
Plus de filtres










Base de données
Gamme d'année
1.
J Neurosci ; 43(11): 1905-1919, 2023 03 15.
Article de Anglais | MEDLINE | ID: mdl-36732070

RÉSUMÉ

Noninvasive electrical stimulation of the vestibular system in humans has become an increasingly popular tool with a broad range of research and clinical applications. However, common assumptions regarding the neural mechanisms that underlie the activation of central vestibular pathways through such stimulation, known as galvanic vestibular stimulation (GVS), have not been directly tested. Here, we show that GVS is encoded by VIIIth nerve vestibular afferents with nonlinear dynamics that differ markedly from those predicted by current models. GVS produced asymmetric activation of both semicircular canal and otolith afferents to the onset versus offset and cathode versus anode of applied current, that in turn produced asymmetric eye movement responses in three awake-behaving male monkeys. Additionally, using computational methods, we demonstrate that the experimentally observed nonlinear neural response dynamics lead to an unexpected directional bias in the net population response when the information from both vestibular nerves is centrally integrated. Together our findings reveal the neural basis by which GVS activates the vestibular system, establish that neural response dynamics differ markedly from current predictions, and advance our mechanistic understanding of how asymmetric activation of the peripheral vestibular system alters vestibular function. We suggest that such nonlinear encoding is a general feature of neural processing that will be common across different noninvasive electrical stimulation approaches.SIGNIFICANCE STATEMENT Here, we show that the application of noninvasive electrical currents to the vestibular system (GVS) induces more complex responses than commonly assumed. We recorded vestibular afferent activity in macaque monkeys exposed to GVS using a setup analogous to human studies. GVS evoked notable asymmetries in irregular afferent responses to cathodal versus anodal currents. We developed a nonlinear model explaining these GVS-evoked afferent responses. Our model predicts that GVS induces directional biases in centrally integrated head motion signals and establishes electrical stimuli that recreate physiologically plausible sensations of motion. Altogether, our findings provide new insights into how GVS activates the vestibular system, which will be vital to advancing new clinical and biomedical applications.


Sujet(s)
Mouvements oculaires , Labyrinthe vestibulaire , Animaux , Mâle , Humains , Labyrinthe vestibulaire/physiologie , Canaux semicirculaires osseux/physiologie , Primates , Sensation , Stimulation électrique/méthodes
2.
BMC Cardiovasc Disord ; 21(1): 319, 2021 06 30.
Article de Anglais | MEDLINE | ID: mdl-34193076

RÉSUMÉ

BACKGROUND: Since the early descriptions of large series of accessory atrioventricular pathway ablations in adults and adolescents over 20 years ago, there have been limited published reports based on more recent experiences of large referral centers. We aimed to characterize accessory pathway distribution and features in a large community-based population that influence ablation outcomes using a tiered approach to ablation. METHODS: Retrospective analysis of 289 patients (age 14-81) who underwent accessory ablation from 2015-2019 was performed. Pathways were categorized into anteroseptal, left freewall, posteroseptal, and right freewall locations. We analyzed patient and pathway features to identify factors associated with prolonged procedure time parameters. RESULTS: Initial ablation success rate was 94.7% with long-term success rate of 93.4% and median follow-up of 931 days. Accessory pathways were in left freewall (61.6%), posteroseptal (24.6%), right freewall (9.6%), and anteroseptal (4.3%) locations. Procedure outcome was dependent on pathway location. Acute success was highest for left freewall pathways (97.1%) with lowest case times (144 ± 68 min) and fluoroscopy times (15 ± 19 min). Longest procedure time parameters were seen with anteroseptal, left anterolateral, epicardial-coronary sinus, and right anterolateral pathway ablations. CONCLUSIONS: In this community-based adult and adolescent population, majority of the accessory pathways are in the left freewall and posteroseptal region and tend to be more easily ablated. A tiered approach with initial use of standard ablation equipment before the deployment of more advance tools, such as irrigated tips and 3D mapping, is cost effective without sacrificing overall efficacy.


Sujet(s)
Faisceau accessoire atrioventriculaire/chirurgie , Troubles du rythme cardiaque/chirurgie , Ablation par cathéter/tendances , Services de santé communautaires/tendances , Prestation intégrée de soins de santé/tendances , Types de pratiques des médecins/tendances , Irrigation thérapeutique/tendances , Faisceau accessoire atrioventriculaire/diagnostic , Faisceau accessoire atrioventriculaire/économie , Faisceau accessoire atrioventriculaire/physiopathologie , Potentiels d'action , Adolescent , Adulte , Sujet âgé , Sujet âgé de 80 ans ou plus , Troubles du rythme cardiaque/diagnostic , Troubles du rythme cardiaque/économie , Troubles du rythme cardiaque/physiopathologie , Ablation par cathéter/effets indésirables , Ablation par cathéter/économie , Prise de décision clinique , Services de santé communautaires/économie , Analyse coût-bénéfice , Prestation intégrée de soins de santé/économie , Femelle , Coûts des soins de santé/tendances , Rythme cardiaque , Humains , Mâle , Adulte d'âge moyen , Durée opératoire , Types de pratiques des médecins/économie , Études rétrospectives , Irrigation thérapeutique/effets indésirables , Irrigation thérapeutique/économie , Facteurs temps , Résultat thérapeutique , Jeune adulte
3.
J Neurosci ; 40(9): 1874-1887, 2020 02 26.
Article de Anglais | MEDLINE | ID: mdl-31959700

RÉSUMÉ

The vestibulocollic reflex is a compensatory response that stabilizes the head in space. During everyday activities, this stabilizing response is evoked by head movements that typically span frequencies from 0 to 30 Hz. Transient head impacts, however, can elicit head movements with frequency content up to 300-400 Hz, raising the question whether vestibular pathways contribute to head stabilization at such high frequencies. Here, we first established that electrical vestibular stimulation modulates human neck motor unit (MU) activity at sinusoidal frequencies up to 300 Hz, but that sensitivity increases with frequency up to a low-pass cutoff of ∼70-80 Hz. To examine the neural substrates underlying the low-pass dynamics of vestibulocollic reflexes, we then recorded vestibular afferent responses to the same electrical stimuli in monkeys. Vestibular afferents also responded to electrical stimuli up to 300 Hz, but in contrast to MUs their sensitivity increased with frequency up to the afferent resting firing rate (∼100-150 Hz) and at higher frequencies afferents tended to phase-lock to the vestibular stimulus. This latter nonlinearity, however, was not transmitted to neck motoneurons, which instead showed minimal phase-locking that decreased at frequencies >75 Hz. Similar to human data, we validated that monkey muscle activity also exhibited low-pass filtered vestibulocollic reflex dynamics. Together, our results show that neck MUs are activated by high-frequency signals encoded by primary vestibular afferents, but undergo low-pass filtering at intermediate stages in the vestibulocollic reflex. These high-frequency contributions to vestibular-evoked neck muscle responses could stabilize the head during unexpected head transients.SIGNIFICANCE STATEMENT Vestibular-evoked neck muscle responses rely on accurate encoding and transmission of head movement information to stabilize the head in space. Unexpected transient events, such as head impacts, are likely to push the limits of these neural pathways since their high-frequency features (0-300 Hz) extend beyond the frequency bandwidth of head movements experienced during everyday activities (0-30 Hz). Here, we demonstrate that vestibular primary afferents encode high-frequency stimuli through frequency-dependent increases in sensitivity and phase-locking. When transmitted to neck motoneurons, these signals undergo low-pass filtering that limits neck motoneuron phase-locking in response to stimuli >75 Hz. This study provides insight into the neural dynamics producing vestibulocollic reflexes, which may respond to high-frequency transient events to stabilize the head.


Sujet(s)
Réflexe vestibulo-oculaire/physiologie , Adulte , Voies afférentes/physiologie , Animaux , Stimulation électrique , Électromyographie , Phénomènes électrophysiologiques/physiologie , Mouvements de la tête/physiologie , Humains , Macaca fascicularis , Mâle , Motoneurones/physiologie , Fibres musculaires squelettiques/physiologie , Muscles du cou/innervation , Muscles du cou/physiologie , Voies nerveuses/physiologie , Jeune adulte
4.
Nat Commun ; 10(1): 1904, 2019 04 23.
Article de Anglais | MEDLINE | ID: mdl-31015434

RÉSUMÉ

Galvanic vestibular stimulation (GVS) uses the external application of electrical current to selectively target the vestibular system in humans. Despite its recent popularity for the assessment/treatment of clinical conditions, exactly how this non-invasive tool activates the vestibular system remains an open question. Here we directly investigate single vestibular afferent responses to GVS applied to the mastoid processes of awake-behaving monkeys. Transmastoid GVS produces robust and parallel activation of both canal and otolith afferents. Notably, afferent activation increases with intrinsic neuronal variability resulting in constant GVS-evoked neuronal detection thresholds across all afferents. Additionally, afferent tuning differs for GVS versus natural self-motion stimulation. Using a stochastic model of repetitive activity in afferents, we largely explain the main features of GVS-evoked vestibular afferent dynamics. Taken together, our results reveal the neural substrate underlying transmastoid GVS-evoked perceptual, ocular and postural responses-information that is essential to advance GVS applicability for biomedical uses in humans.


Sujet(s)
Potentiels d'action/physiologie , Potentiels évoqués somatosensoriels/physiologie , Mouvements oculaires/physiologie , Posture/physiologie , Nerf vestibulaire/physiologie , Labyrinthe vestibulaire/physiologie , Voies afférentes/physiologie , Animaux , Comportement animal/physiologie , Électrodes implantées , Macaca fascicularis , Mâle , Modèles neurologiques , Techniques stéréotaxiques , Processus stochastiques , Stimulation transcrânienne par courant continu , Labyrinthe vestibulaire/innervation
5.
Elife ; 72018 12 18.
Article de Anglais | MEDLINE | ID: mdl-30561328

RÉSUMÉ

It is commonly assumed that the brain's neural coding strategies are adapted to the statistics of natural stimuli. Specifically, to maximize information transmission, a sensory neuron's tuning function should effectively oppose the decaying stimulus spectral power, such that the neural response is temporally decorrelated (i.e. 'whitened'). However, theory predicts that the structure of neuronal variability also plays an essential role in determining how coding is optimized. Here, we provide experimental evidence supporting this view by recording from neurons in early vestibular pathways during naturalistic self-motion. We found that central vestibular neurons displayed temporally whitened responses that could not be explained by their tuning alone. Rather, computational modeling and analysis revealed that neuronal variability and tuning were matched to effectively complement natural stimulus statistics, thereby achieving temporal decorrelation and optimizing information transmission. Taken together, our findings reveal a novel strategy by which neural variability contributes to optimized processing of naturalistic stimuli.


Sujet(s)
Mouvements de la tête/physiologie , Voies nerveuses/physiologie , Neurones/physiologie , Primates/physiologie , Labyrinthe vestibulaire/physiologie , Algorithmes , Animaux , Macaca fascicularis/physiologie , Macaca mulatta/physiologie , Mâle , Modèles neurologiques , Déplacement , Labyrinthe vestibulaire/cytologie
6.
Anal Chem ; 87(5): 2565-9, 2015 Mar 03.
Article de Anglais | MEDLINE | ID: mdl-25629426

RÉSUMÉ

A simple, fast, and reproducible method for the fabrication of disk ultramicroelectrodes (UMEs) with controlled geometry is reported. The use of prepulled soda-lime glass capillaries allows one to bypass the irreproducible torch-sealing and experimentally challenging tip-sharpening steps used in conventional fabrication protocols. A micron-sized electroactive wire is sealed inside this capillary producing UMEs with a highly reproducible geometry. Total fabrication time (1 h) and experimental difficulty are significantly reduced. Disk UMEs with various diameters and cores were fabricated, including carbon fiber (7 and 11 µm), gold (10 and 25 µm), platinum (10 and 25 µm), silver (25 µm), and mercury (25 µm). The ratio of the insulating sheath to the electroactive core of the UMEs was 2.5-3.6. Silver UMEs were also used to produce a Ag/AgCl microreference electrode. This general fabrication method can readily be applied to other electroactive cores and could allow any research group to produce high quality disk UMEs, which are a prerequisite for quantitative scanning electrochemical microscopy.

7.
Anal Chem ; 86(7): 3501-7, 2014 Apr 01.
Article de Anglais | MEDLINE | ID: mdl-24650010

RÉSUMÉ

At the synapse, D-serine is an endogenous co-agonist for the N-methyl-D-aspartate receptor (NMDAR). It plays an important role in synaptic transmission and plasticity and has also been linked to several pathological diseases such as schizophrenia and Huntington's. The quantification of local changes in D-serine concentration is essential to further understanding these processes. We report herein the development of a disk-shaped amperometric enzymatic biosensor for detection of D-serine based on a 25 µm diameter platinum disk microelectrode with an electrodeposited poly-m-phenylenediamine (PPD) layer and an R. gracilis D-amino acid oxidase (RgDAAO) layer. The disk-shaped D-serine biosensor is 1-5 orders of magnitude smaller than previously reported probes and exhibits a sensitivity of 276 µA cm(-2) mM(-1) with an in vitro detection limit of 0.6 µM. We demonstrate its usefulness for in vivo applications by measuring the release of endogenous D-serine in the brain of Xenopus laevis tadpoles.


Sujet(s)
Techniques de biocapteur , D-amino-acid oxidase/composition chimique , Techniques électrochimiques/instrumentation , Sérine/analyse , Animaux , Limite de détection , Microélectrodes , Xenopus laevis
SÉLECTION CITATIONS
DÉTAIL DE RECHERCHE
...