Your browser doesn't support javascript.
loading
Montrer: 20 | 50 | 100
Résultats 1 - 5 de 5
Filtrer
Plus de filtres










Base de données
Gamme d'année
1.
J Occup Environ Hyg ; 18(6): 276-287, 2021 06.
Article de Anglais | MEDLINE | ID: mdl-34004120

RÉSUMÉ

Home care (HC) aide visits to clients' homes often involve cleaning and disinfecting (C&D) bathrooms. Some ingredients in C&D household products are associated with respiratory illness, including sodium hypochlorite (bleach) and quaternary ammonium compounds (quats). "Green" products may be safer for the environment, however there are limited quantitative evaluations of their respiratory risks. This study assessed airborne concentrations and time profiles of total volatile organic compounds (TVOC) and chlorine generated during typical bathroom cleaning performed by aides using conventional and green products. Aides performed cleaning tasks in a simulated residential bathroom constructed in an environmental air sampling laboratory. A balanced experimental design involved each aide coming to the lab for four visits during which she performed two 20-min cleaning sessions using one of three C&D products (bleach-based, 1-5% sodium hypochlorite by weight; quats-based, 0.1-1% by weight quaternary ammonium compounds; and "green," 0.05% by weight thymol, a component of botanical thyme oil) or distilled water as a control. TVOC and chlorine direct reading instruments were attached to aides with sample inlets located in the breathing zone. Ten-second averages of TVOC and chlorine gas concentrations and instantaneous peak concentrations were recorded for the sessions' duration. TVOC concentrations by methods of C&D application (spraying, streaming, wiping) also were evaluated. The study completed 169 air sampling sessions with 22 aides. The quats-based product generated more than twice the average TVOC concentrations (mean = 1,210 ppb) than the bleach-based (mean = 593 ppb) or green (mean = 498 ppb) products. Each product generated TVOC concentrations that rose rapidly within the first few minutes of application. Spraying produced the highest TVOC exposures, wiping the lowest. Thirteen aides (65%) experienced peak chlorine exposures above the OSHA PEL ceiling limit (1 ppm) when using the bleach-based product. HC aides may experience respiratory hazards from use of conventional or green C&D products formulated with bleach or other respiratory irritants and sprayed in small, poorly ventilated spaces typical of bathrooms. Spraying should be avoided.


Sujet(s)
Auxiliaires de vie , Composés organiques volatils , Chlore , Femelle , Humains , Plan de recherche , Toilettes
2.
J Chem Health Saf ; 26(2): 19-30, 2019 Mar.
Article de Anglais | MEDLINE | ID: mdl-31798757

RÉSUMÉ

There is a paucity of data on additive manufacturing process emissions and personal exposures in real-world workplaces. Hence, we evaluated atmospheres in four workplaces utilizing desktop "3-dimensional" (3-d) printers [fused filament fabrication (FFF) and sheer] for production, prototyping, or research. Airborne particle diameter and number concentration and total volatile organic compound concentrations were measured using real-time instruments. Airborne particles and volatile organic compounds were collected using time-integrated sampling techniques for off-line analysis. Personal exposures for metals and volatile organic compounds were measured in the breathing zone of operators. All 3-d printers that were monitored released ultrafine and fine particles and organic vapors into workplace air. Particle number-based emission rates (#/min) ranged from 9.4 × 109 to 4.4 × 1011 (n = 9samples) for FFF3-d printers and from 1.9 to 3.8 × 109 (n = 2 samples) for a sheer 3-d printer. The large variability in emission rate values reflected variability from the printers as well as differences in printer design, operating conditions, and feedstock materials among printers. A custom-built ventilated enclosure evaluated at one facility was capable of reducing particle number and total organic chemical concentrations by 99.7% and 53.2%, respectively. Carbonyl compounds were detected in room air; however, none were specifically attributed to the 3-d printing process. Personal exposure to metals (aluminum, iron) and 12 different organic chemicals were all below applicable NIOSH Recommended Exposure Limit values, but results are not reflective of all possible exposure scenarios. More research is needed to understand 3-d printer emissions, exposures, and efficacy of engineering controls in occupational settings.

3.
Saf Health Work ; 10(2): 229-236, 2019 Jun.
Article de Anglais | MEDLINE | ID: mdl-31297287

RÉSUMÉ

BACKGROUND: Emerging reports suggest the potential for adverse health effects from exposure to emissions from some additive manufacturing (AM) processes. There is a paucity of real-world data on emissions from AM machines in industrial workplaces and personal exposures among AM operators. METHODS: Airborne particle and organic chemical emissions and personal exposures were characterized using real-time and time-integrated sampling techniques in four manufacturing facilities using industrial-scale material extrusion and material jetting AM processes. RESULTS: Using a condensation nuclei counter, number-based particle emission rates (ERs) (number/min) from material extrusion AM machines ranged from 4.1 × 1010 (Ultem filament) to 2.2 × 1011 [acrylonitrile butadiene styrene and polycarbonate filaments). For these same machines, total volatile organic compound ERs (µg/min) ranged from 1.9 × 104 (acrylonitrile butadiene styrene and polycarbonate) to 9.4 × 104 (Ultem). For the material jetting machines, the number-based particle ER was higher when the lid was open (2.3 × 1010 number/min) than when the lid was closed (1.5-5.5 × 109 number/min); total volatile organic compound ERs were similar regardless of the lid position. Low levels of acetone, benzene, toluene, and m,p-xylene were common to both AM processes. Carbonyl compounds were detected; however, none were specifically attributed to the AM processes. Personal exposures to metals (aluminum and iron) and eight volatile organic compounds were all below National Institute for Occupational Safety and Health (NIOSH)-recommended exposure levels. CONCLUSION: Industrial-scale AM machines using thermoplastics and resins released particles and organic vapors into workplace air. More research is needed to understand factors influencing real-world industrial-scale AM process emissions and exposures.

4.
J Occup Environ Hyg ; 16(8): 519-531, 2019 Aug.
Article de Anglais | MEDLINE | ID: mdl-31094667

RÉSUMÉ

Little is known about emissions and exposure potential from vat polymerization additive manufacturing, a process that uses light-activated polymerization of a resin to build an object. Five vat polymerization printers (three stereolithography (SLA) and two digital light processing (DLP) were evaluated individually in a 12.85 m3 chamber. Aerosols (number, size) and total volatile organic compounds (TVOC) were measured using real-time monitors. Carbonyl vapors and particulate matter were collected for offline analysis using impingers and filters, respectively. During printing, particle emission yields (#/g printed) ranged from 1.3 ± 0.3 to 2.8 ± 2.6 x 108 (SLA printers) and from 3.3 ± 1.5 to 9.2 ± 3.0 x 108 (DLP printers). Yields for number of particles with sizes 5.6 to 560 nm (#/g printed) were 0.8 ± 0.1 to 2.1 ± 0.9 x 1010 and from 1.1 ± 0.3 to 4.0 ± 1.2 x 1010 for SLA and DLP printers, respectively. TVOC yield values (µg/g printed) ranged from 161 ± 47 to 322 ± 229 (SLA printers) and from 1281 ± 313 to 1931 ± 234 (DLP printers). Geometric mean mobility particle sizes were 41.1-45.1 nm for SLA printers and 15.3-28.8 nm for DLP printers. Mean particle and TVOC yields were statistically significantly higher and mean particle sizes were significantly smaller for DLP printers compared with SLA printers (p < 0.05). Energy dispersive X-ray analysis of individual particles qualitatively identified potential occupational carcinogens (chromium, nickel) as well as reactive metals implicated in generation of reactive oxygen species (iron, zinc). Lung deposition modeling indicates that about 15-37% of emitted particles would deposit in the pulmonary region (alveoli). Benzaldehyde (1.0-2.3 ppb) and acetone (0.7-18.0 ppb) were quantified in emissions from four of the printers and 4-oxopentanal (0.07 ppb) was detectable in the emissions from one printer. Vat polymerization printers emitted nanoscale particles that contained potential carcinogens, sensitizers, and reactive metals as well as carbonyl compound vapors. Differences in emissions between SLA and DLP printers indicate that the underlying technology is an important factor when considering exposure reduction strategies such as engineering controls.


Sujet(s)
Pollution de l'air intérieur/analyse , Matière particulaire/analyse , Impression tridimensionnelle , Composés organiques volatils/analyse , Cancérogènes , Métaux , Taille de particule , Matière particulaire/composition chimique , Polymérisation
5.
Toxicol Appl Pharmacol ; 335: 1-5, 2017 11 15.
Article de Anglais | MEDLINE | ID: mdl-28942003

RÉSUMÉ

Fused deposition modeling (FDM™), or three-dimensional (3D) printing has become routine in industrial, occupational and domestic environments. We have recently reported that 3D printing emissions (3DPE) are complex mixtures, with a large ultrafine particulate matter component. Additionally, we and others have reported that inhalation of xenobiotic particles in this size range is associated with an array of cardiovascular dysfunctions. Sprague-Dawley rats were exposed to 3DPE aerosols via nose-only exposure for ~3h. Twenty-four hours later, intravital microscopy was performed to assess microvascular function in the spinotrapezius muscle. Endothelium-dependent and -independent arteriolar dilation were stimulated by local microiontophoresis of acetylcholine (ACh) and sodium nitroprusside (SNP). At the time of experiments, animals exposed to 3DPE inhalation presented with a mean arterial pressure of 125±4mmHg, and this was significantly higher than that for the sham-control group (94±3mmHg). Consistent with this pressor response in the 3DPE group, was an elevation of ~12% in resting arteriolar tone. Endothelium-dependent arteriolar dilation was significantly impaired after 3DPE inhalation across all iontophoretic ejection currents (0-27±15%, compared to sham-control: 15-120±21%). Endothelium-independent dilation was not affected by 3DPE inhalation. These alterations in peripheral microvascular resistance and reactivity are consistent with elevations in arterial pressure that follow 3DPE inhalation. Future studies must identify the specific toxicants generated by FDM™ that drive this acute pressor response.


Sujet(s)
Pression artérielle/effets des médicaments et des substances chimiques , Hypertension artérielle/physiopathologie , Exposition par inhalation/effets indésirables , Microcirculation/effets des médicaments et des substances chimiques , Microvaisseaux/effets des médicaments et des substances chimiques , Matière particulaire/toxicité , Impression tridimensionnelle , Muscles superficiels du dos/vascularisation , Maladie aigüe , Animaux , Humains , Hypertension artérielle/induit chimiquement , Microscopie intravitale , Ionophorèse , Mâle , Microvaisseaux/physiopathologie , Modèles animaux , Exposition professionnelle/effets indésirables , Rat Sprague-Dawley , Appréciation des risques , Facteurs temps , Résistance vasculaire/effets des médicaments et des substances chimiques , Vasodilatation/effets des médicaments et des substances chimiques , Vasodilatateurs/administration et posologie
SÉLECTION CITATIONS
DÉTAIL DE RECHERCHE
...