Your browser doesn't support javascript.
loading
Montrer: 20 | 50 | 100
Résultats 1 - 2 de 2
Filtrer
Plus de filtres











Gamme d'année
1.
Se Pu ; 42(9): 856-865, 2024 Sep.
Article de Chinois | MEDLINE | ID: mdl-39198944

RÉSUMÉ

Neonicotinoid pesticides are a relatively new class of pesticides that have garnered significant attention owing to their potential ecological risks to nontarget organisms. A method combining solid phase extraction with liquid chromatography-tandem mass spectrometry (SPE-LC-MS/MS) was developed for the rapid and accurate detection of eight neonicotinoid pesticides (dinotefuran, E-nitenpyram, thiamethoxam, clothianidin, imidacloprid, imidaclothiz, acetamiprid, and thiacloprid) in wastewater. The chromatographic mobile phase and MS parameters were selected, and a single-factor method was used to determine the optimal column type, extraction volume, sample loading speed, and pH for SPE. The optimal parameters were as follows: column type, HLB column (500 mg/6 mL); sample extraction volume, 500 mL; sample loading speed, 10 mL/min; and sample pH, 6-8. The matrix effects of the wastewater samples were reduced by optimizing the chromatographic gradient-elution program, examining the dilution factor of the samples, and using the isotope internal standard calibration method. Prior to analysis, the wastewater samples were diluted 5-fold with ultrapure water for pretreatment. Subsequently, 2 mmol/L ammonium acetate aqueous solution containing 0.1% (v/v) formic acid and methanol was used as mobile phases for gradient elution on a ZORBAX Eclipse Plus C18 column (100 mm×2.1 mm, 1.8 µm). The samples were quantified using positive-ion multiple reaction monitoring (MRM) mode for 10 min. Imidacloprid-d4 was used as the isotope internal standard. The SPE process was further optimized by applying response surface methodology to select the type and mass of rinsing and elution solvents. The optimal pretreatment of the SPE column included rinsing with 10% methanol aqueous solution and elution with methanol-acetonitrile (1∶1, v/v) mixture (7 mL). The eight neonicotinoid pesticides showed satisfactory linearity within the relevant range, with linear correlation coefficients (r) all greater than 0.9990. The method detection limits (MDLs) ranged from 0.2 to 1.2 ng/L, and the method quantification limits (MQLs) ranged from 0.8 to 4.8 ng/L. The average recoveries of the eight neonicotinoid pesticides were in the range of 82.6%-94.2% at three spiked levels, with relative standard deviations (RSDs) ranging from 3.9% to 9.4%. Finally, the optimized method was successfully applied to analyze wastewater samples collected from four sewage treatment plants. The results indicated that the eight neonicotinoid pesticides could be generally detected at concentrations ranging from not detected (ND) to 256 ng/L. The developed method has a low MDL and high accuracy, rendering it a suitable choice for the trace detection of the eight neonicotinoid pesticides in wastewater when compared with other similar methods. The proposed method can be utilized to monitor the environmental impact and assess the potential risks of neonicotinoid pesticides in wastewater, thus promoting the protection of nontarget organisms and the sustainable use of these pesticides in agriculture.


Sujet(s)
Néonicotinoïdes , Composés nitrés , Extraction en phase solide , Spectrométrie de masse en tandem , Eaux usées , Polluants chimiques de l'eau , Spectrométrie de masse en tandem/méthodes , Extraction en phase solide/méthodes , Eaux usées/composition chimique , Eaux usées/analyse , Néonicotinoïdes/analyse , Polluants chimiques de l'eau/analyse , Chromatographie en phase liquide/méthodes , Composés nitrés/analyse , Thiaméthoxame/analyse , Guanidines/analyse , Thiazoles/analyse , Pesticides/analyse , Thiazines/analyse , Oxazines/analyse
2.
Article de Chinois | WPRIM (Pacifique Occidental) | ID: wpr-775938

RÉSUMÉ

OBJECTIVE@#To explore the clinical effect of rapid massage at Shuidao (ST 28) to prevent puerpera from postpartum urinary retention.@*METHODS@#A total of 200 puerpera giving birth through vagina were enrolled and divided into an observation group and a control group according to the random number table method, 100 cases in each group. In the observation group, rapid massage at Shuidao (ST 28) was applied. In the control group,there was no intervention and urinated naturally. The traditional Chinese medicine syndrome scale was used to evaluate poor sense of urination, and record puerpera with or without postpartum urinary retention, the poor sense of first urination, the first time of urination, the amount of first urination and postpartum hemorrhage.@*RESULTS@#The poor sense of first urination in the observation group was significantly lower than that in the control (<0.001), the first time of urination in the observation group was significantly earlier than that in the control group (<0.001), the amount of first urination in the observation group was significantly more than that in the control group (<0.001), the observation group was superior to the control group to prevent postpartum urinary retention (<0.05).@*CONCLUSION@#Rapid massage at Shuidao (ST 28) can reduce the poor sense of first urination, significantly advance the time of spontaneous urination, significantly increase the amount of first urination and effectively prevent postpartum urinary retention.


Sujet(s)
Femelle , Humains , Grossesse , Points d'acupuncture , Massage , Période du postpartum , Rétention d'urine , Thérapeutique , Miction
SÉLECTION CITATIONS
DÉTAIL DE RECHERCHE