1.
J Clin Med ; 13(10)2024 May 09.
Article de Anglais | MEDLINE | ID: mdl-38792344

RÉSUMÉ

OBJECTIVE: In treatment of aneurysms (SAAs) and pseudoaneurysms (SAPs) of the splenic artery, endovascular coil embolization is the approach most commonly used as it is minimally invasive and safe. However, it carries a significant rate of primary failure (up to 30%) and might be complicated by splenic infarction. The use of stent grafts might represent a valuable alternative when specific anatomical criteria are respected. We report a comprehensive review on technical and clinical outcomes achieved in this setting. Methods: We performed a comprehensive review of the literature through the MedLine and Cochrane databases (from January 2000 to December 2023) on reported cases of stenting for SAAs and SAPs. Outcomes of interest were clinical and technical success and related complications. The durability of the procedure in the long-term was also investigated. Results: Eighteen papers were included in the analysis, totalling 41 patients (n = 20 male 48.8%, mean age 55.5, range 32-82 years; n = 31, 75.6% SAAs). Mean aneurysm diameter in non-ruptured cases was 35 mm (range 20-67 mm), and most lesions were detected at the proximal third of the splenic artery. Stent grafting was performed in an emergent setting in n = 10 (24.3%) cases, achieving immediate clinical and technical success rate in 90.2% (n = 37) of patients regardless of the type of stent-graft used. There were no procedure-related deaths, but one patient died in-hospital from septic shock and n = 2 (4.9%) patients experienced splenic infarction. At the last available follow-up, the complete exclusion of the aneurysm was confirmed in 87.8% of cases (n = 36/41), while no cases of aneurysm growing nor endoleak were reported. None of the patients required re-intervention during follow-up. Conclusions: When specific anatomical criteria are respected, endovascular repair of SAAs and SAAPs using stent grafts appears to be safe and effective, and seems to display a potential advantage in respect to simple coil embolization, preserving the patient from the risk of end-organ ischemia.

2.
Ann Vasc Surg ; 105: 177-188, 2024 Aug.
Article de Anglais | MEDLINE | ID: mdl-38599483

RÉSUMÉ

BACKGROUND: The use of biological grafts provides acceptable mid- and long-term results in native or prosthetic vascular infections. Several reports describe the successful use of bovine pericardium in case of vascular infections, mainly as a large patch to be sutured as a tubular graft. Recently, a novel prefabricated bovine pericardium graft (Biointegral Surgical No-React® Inc, Mississauga, ON, Canada) has been introduced in clinical practice with promising results. In this study, we report our preliminary experience utilizing Biointegral Surgical graft in case of native and or prosthetic aorto-iliac and infrainguinal infection. METHODS: We retrospectively analyzed data from 20 patients with native or prosthetic aorto-iliac and infrainguinal infection who underwent in situ reconstruction (ISR) with a Biointegral Surgical No-React bovine pericardium prosthesis between October 2020 and February 2023 at the Vascular Surgery Unit of the Fondazione Policlinico Universitario Gemelli - IRCCS in Rome, Italy. All patients followed a standardized protocol including postoperative anticoagulation and long-term intravenous antibiotics. RESULTS: The indication for surgery was: mycotic aortic aneurysm in 4 patients (20%), graft infection after abdominal aortic repair in 11 patients (55%), peripheral graft infection in 5 patients (25%). Complete excision of the infected aorta or prosthetic graft, surgical debridement and ISR were performed in all patients. Hospital mortality rate was 5% (n = 1) and graft-related mortality of 0%. During follow-up (median 13 months, range 6-34 months), reinfection was 5.2% and primary graft patency 94.7%. CONCLUSIONS: The use of prefabricated bovine pericardial grafts represents a promising option for the treatment of native and prosthetic aorto-iliac and infrainguinal infections. The application of this biological graft with a standardized postoperative protocol has been associated with a satisfactory patency and reinfection rate without increased bleeding complications.


Sujet(s)
Bioprothèse , Implantation de prothèses vasculaires , Prothèse vasculaire , Péricarde , Conception de prothèse , Infections dues aux prothèses , Humains , Infections dues aux prothèses/chirurgie , Infections dues aux prothèses/microbiologie , Infections dues aux prothèses/diagnostic , Infections dues aux prothèses/mortalité , Prothèse vasculaire/effets indésirables , Études rétrospectives , Péricarde/transplantation , Mâle , Implantation de prothèses vasculaires/instrumentation , Implantation de prothèses vasculaires/effets indésirables , Implantation de prothèses vasculaires/mortalité , Sujet âgé , Résultat thérapeutique , Femelle , Adulte d'âge moyen , Animaux , Bovins , Facteurs temps , Hétérogreffes , Sujet âgé de 80 ans ou plus , Artère iliaque/chirurgie , Antibactériens/administration et posologie , Facteurs de risque , Degré de perméabilité vasculaire , Anévrysme infectieux/chirurgie , Anévrysme infectieux/microbiologie , Anévrysme infectieux/mortalité , Anévrysme infectieux/imagerie diagnostique , Réintervention
3.
J Vasc Surg Cases Innov Tech ; 9(3): 101276, 2023 Sep.
Article de Anglais | MEDLINE | ID: mdl-37662566

RÉSUMÉ

Despite the technical innovations introduced in the previous decades, open thoracoabdominal aortic aneurysm repair still represents an enormous challenge for patients and surgeons. Logically, the systemic inflammatory response resulting from these massive operations appears considerable; however, the response has never been thoroughly investigated. In addition, intraoperative adjuncts to modulate the postoperative activation of the immune system have not yet been introduced into clinical practice. We report a case of intraoperative hemadsorption during open repair of a thoracoabdominal aortic aneurysm through the introduction of a CytoSorb device (CytoSorbents Corp) in the left heart bypass circuit. The technique appeared feasible and safe and probably contributed to the good clinical outcomes.

4.
Semin Vasc Surg ; 36(2): 328-339, 2023 Jun.
Article de Anglais | MEDLINE | ID: mdl-37330245

RÉSUMÉ

Severe surgical site infections (SSIs) are a frequent nosocomial complication after vascular interventions, an important cause of postoperative morbidity, and a substantial burden to the health care system. Patients undergoing arterial interventions are at elevated risk of SSIs, possibly because of the presence of several risk factors in this patient population. In this review, we examined the available clinical evidence for the prevention, treatment, and prognostication of postoperative severe SSIs after vascular exposure in the groin and other body areas. Results from studies evaluating preoperative, intraoperative, and postoperative preventive strategies and several treatment options are reviewed. In addition, risk factors for surgical wound infections are analyzed in detail and related evidence from the literature is highlighted. Although several measures have been implemented over the time to prevent them, SSIs continue to pose a substantial health care and socioeconomic challenge. Therefore, strategies to decrease the risk and improve the treatment of SSIs for the high-risk vascular patient population should be the focus of continuing improvement and critical review. This review aimed at identifying and reviewing the current evidence for preventing, treating, and performing stratification according to the prognosis of postoperative severe SSIs after vascular exposure in the groin and other body areas.


Sujet(s)
Aine , Infection de plaie opératoire , Humains , Infection de plaie opératoire/diagnostic , Infection de plaie opératoire/prévention et contrôle , Pronostic , Procédures de chirurgie vasculaire/effets indésirables , Facteurs de risque
SÉLECTION CITATIONS
DÉTAIL DE RECHERCHE