Your browser doesn't support javascript.
loading
Montrer: 20 | 50 | 100
Résultats 1 - 20 de 28
Filtrer
1.
Radiographics ; 44(7): e230203, 2024 Jul.
Article de Anglais | MEDLINE | ID: mdl-38900679

RÉSUMÉ

Rectal MRI provides a detailed depiction of pelvic anatomy; specifically, the relationship of the tumor to key anatomic structures, including the mesorectal fascia, anterior peritoneal reflection, and sphincter complex. However, anatomic inconsistencies, pitfalls, and confusion exist, which can have a strong impact on interpretation and treatment. These areas of confusion include the definition of the rectum itself, specifically differentiation of the rectum from the anal canal and the sigmoid colon, and delineation of the high versus low rectum. Other areas of confusion include the relative locations of the mesorectal fascia and peritoneum and their significance in staging and treatment, the difference between the mesorectal fascia and circumferential resection margin, involvement of the sphincter complex, and evaluation of lateral pelvic lymph nodes. The impact of these anatomic inconsistencies and sources of confusion is significant, given the importance of MRI in depicting the anatomic relationship of the tumor to critical pelvic structures, to triage surgical resection and neoadjuvant chemoradiotherapy with the goal of minimizing local recurrence. Evolving treatment paradigms also place MRI central in management of rectal cancer. ©RSNA, 2024.


Sujet(s)
Imagerie par résonance magnétique , Stadification tumorale , Tumeurs du rectum , Humains , Canal anal/imagerie diagnostique , Canal anal/anatomopathologie , Canal anal/anatomie et histologie , Imagerie par résonance magnétique/méthodes , Tumeurs du rectum/imagerie diagnostique , Tumeurs du rectum/anatomopathologie , Tumeurs du rectum/thérapie , Rectum/imagerie diagnostique , Rectum/anatomopathologie
2.
OTO Open ; 8(1): e110, 2024.
Article de Anglais | MEDLINE | ID: mdl-38333549

RÉSUMÉ

Deconstructing surgeries into steps and providing instructions with illustrations has been the staple of surgical textbooks for decades. However, it may be difficult for the novice surgeon to interpret 2-dimensional (2D) illustrations into 3D surgeries. The objective of this study is to create operable models that demonstrate the progression of surgery in 3D and allow for mastering the final steps of the operation first. Mastoidectomy was performed in a stepwise fashion to different end points on 5 identical 3D-printed temporal bone models to represent 5 major steps of the operation. The drilled models were computed tomography scanned and the subsequent images were used to create 3D model copies of each step. This is the first study to demonstrate that it is possible to create, scan, and copy stepwise, operable, patient-specific 3D-printed models, which the trainee can both reference as a 3D dissection guide and can operate on repeatedly and in any order.

3.
Abdom Radiol (NY) ; 49(2): 357-364, 2024 Feb.
Article de Anglais | MEDLINE | ID: mdl-37989898

RÉSUMÉ

PURPOSE: To assess the diagnostic performance and reliability of 18 CT signs to diagnose cecal volvulus, a surgical emergency, versus a group of non-volvulus mimickers. MATERIALS AND METHODS: Four radiologists retrospectively and independently assessed 18 CT signs in 191 patients with cecal volvulus (n = 63) or a non-volvulus control group ((n = 128), including cecal bascule (n = 19), mobile cecum (n = 95), and colonic pseudo-obstruction (n = 14)) at a single institution from 2013 to 2021. Fleiss' kappa coefficient was used to assess inter-reader agreement. For diagnostic performance metrics, we assessed sensitivity, specificity, and positive and negative predictive values. For predictive performance, all 18 signs were included in bivariate and stepwise lasso multivariate logistic regression models to diagnose cecal volvulus. Performance was assessed by ROC curves. RESULTS: 191 patients (mean age: 63 years +/- 15.5 [SD]; 135 women) were included in the study. Nine of the 18 CT signs of cecal volvulus demonstrated good or better (> 0.6) inter-reader agreement. Individual CT signs with sensitivity, specificity, positive and negative predictive values all above 70% for diagnosing cecal volvulus were transition point, bird beak, and X-marks-the-spot. A lasso regression model determined four CT features: transition point, bird beak, coffee bean, and whirl had excellent prediction (AUC = .979) for cecal volvulus if all present. CONCLUSION: CT signs for cecal volvulus that have high sensitivity and specificity include: transition point, bird beak, and X-marks-the-spot and were reliable in distinguishing non-volvulus mimickers. If the following four features were present: transition point, bird beak, coffee bean, and whirl, there was excellent prediction (AUC = .979) for cecal volvulus.


Sujet(s)
Maladies du caecum , Volvulus intestinal , Humains , Femelle , Adulte d'âge moyen , Volvulus intestinal/imagerie diagnostique , Études rétrospectives , Reproductibilité des résultats , Tomodensitométrie , Valeur prédictive des tests , Maladies du caecum/imagerie diagnostique
4.
Br J Radiol ; 96(1144): 20221079, 2023 Mar 01.
Article de Anglais | MEDLINE | ID: mdl-36802978

RÉSUMÉ

OBJECTIVE: To describe instances of iodine, or other element with similar K-edge to iodine, accumulating in benign renal cysts and simulating solid renal masses (SRM) at single-phase contrast-enhanced (CE) dual-energy CT (DECT). METHODS: During the course of routine clinical practice, instances of benign renal cysts (reference standard true non-contrast enhanced CT [NCCT] homogeneous attenuation <10 HU and not enhancing, or MRI) simulating SRM at follow-up single-phase CE-DECT due to iodine (or other element) accumulation were documented in two institutions over a 3-month observation period in 2021. RESULTS: Five Bosniak one renal cysts (12 ± 7 mm) in five patients changed nature on follow-up imaging simulating SRM at CE-DECT. At time of DECT, cyst attenuation on true NCCT (mean 91 ± 25 HU [Range 56-120]) was significantly higher compared to virtual NCCT (mean 11 ± 22 HU [-23-30], p = 0.003) and all five cysts showed internal iodine content on DECT iodine maps with concentration >1.9 mg ml-1 (mean 8.2 ± 7.6 mg ml-1 [2.8-20.9]). CONCLUSION: The accumulation of iodine, or other element with similar K-edge to iodine, in benign renal cysts could simulate enhancing renal masses at single-phase contrast-enhanced DECT.


Sujet(s)
Kystes , Iode , Maladies kystiques rénales , Tumeurs du rein , Radiographie digitale par projection en double énergie , Humains , Tomodensitométrie/méthodes , Produits de contraste , Tumeurs du rein/imagerie diagnostique , Radiographie digitale par projection en double énergie/méthodes , Kystes/imagerie diagnostique , Maladies kystiques rénales/imagerie diagnostique
5.
Acad Radiol ; 30(8): 1727-1734, 2023 08.
Article de Anglais | MEDLINE | ID: mdl-36690562

RÉSUMÉ

RATIONALE AND OBJECTIVES: The purpose of this study was to assess differences in first-year radiology resident perception of the match process and early satisfaction with residency programs between those who matched in 2020 versus 2021, the first virtual application cycle after the start of the COVID-19 pandemic. MATERIALS AND METHODS: A 33-question survey was distributed to first-year diagnostic radiology residents at programs throughout the United States through the Association of Program Directors in Radiology. Responses were collected in June of 2022 from residents who matched in 2020 and in July of 2022 from residents who matched in 2021. Questions were designed to assess applicant demographics, outcomes and attitudes towards the interview process. Comparison was made between the two cohorts. RESULTS: Of the 2231 matched residents in the 2020 and 2021 match years, 108 residents (4.8%) received, responded, and met inclusion criteria for the survey. Forty-three of 46 (92.5%) respondents that matched in 2020 interviewed in-person compared to one of 60 (1.7%) that matched in 2021 (p < 0.0001). There was no difference in satisfaction of match results, current training programs, work culture, satisfaction with facilities, and depiction of residency structure. Applicants from the 2021 cohort were more likely to express concerns about interview hoarding, having enough time to ask questions on interview days, and ability to accurately present themselves in interviews but were more likely to favor virtual interviews for future cycles. CONCLUSION: The virtual interview process is perceived neutrally or positively by most early diagnostic radiology residents and produced similar satisfactory results compared to applicants that interviewed in person. Attention should be given to concerns of those who matched virtually if the virtual interview process is to be continued.


Sujet(s)
COVID-19 , Internat et résidence , Radiologie , Humains , États-Unis , Pandémies , COVID-19/épidémiologie , Radiologie/enseignement et éducation , Radiographie , Dépistage de la COVID-19
6.
JCO Clin Cancer Inform ; 6: e2200023, 2022 11.
Article de Anglais | MEDLINE | ID: mdl-36332157

RÉSUMÉ

PURPOSE: Variability in computed tomography images intrinsic to individual scanners limits the application of radiomics in clinical and research settings. The development of reproducible and generalizable radiomics-based models to assess lesions requires harmonization of data. The purpose of this study was to develop, test, and analyze the efficacy of a radiomics data harmonization model. MATERIALS AND METHODS: Radiomic features from biopsy-proven untreated hepatic metastasis (N = 380) acquired from 167 unique patients with pancreatic, colon, and breast cancers were analyzed. Radiomic features from volume-match 551 samples of normal liver tissue and 188 hepatic cysts were included as references. A novel linear mixed effect model was used to identify effects associated with lesion size, tissue type, and scanner model. Six separate machine learning models were then used to test the effectiveness of radiomic feature harmonization using multivariate analysis. RESULTS: Proposed model identifies and removes scanner-associated effects while preserving cancer-specific functional dependence of radiomic features on the tumor size. Data harmonization improves the performance of classification models by reducing the scanner-associated variability. For example, the multiclass logistic regression model, LogitBoost, demonstrated the improvement in sensitivity in the range from 15% to 40% for each type of liver metastasis, whereas the overall model accuracy and the kappa coefficient increased by 5% and 8% accordingly. CONCLUSION: The model removed scanner-associated effects while preserving cancer-specific functional dependence of radiomic features.


Sujet(s)
Tumeurs du sein , Tomodensitométrie , Humains , Femelle , Tomodensitométrie/méthodes , Tumeurs du sein/imagerie diagnostique , Apprentissage machine
7.
Abdom Radiol (NY) ; 47(10): 3364-3374, 2022 10.
Article de Anglais | MEDLINE | ID: mdl-35881198

RÉSUMÉ

OBJECTIVE: To review existing structured MRI reports for primary staging of rectal cancer and create a new, freely available structured report based on multidisciplinary expert opinion and literature review. METHODS: Twenty abdominal imaging experts from the Society of Abdominal Radiology (SAR)'s Disease Focused Panel (DFP) on Rectal and Anal Cancer completed a questionnaire and participated in a subsequent consensus meeting based on the RAND-UCLA Appropriateness Method. Twenty-two items were classified via a group survey as "appropriate" or "inappropriate" (defined by ≥ 70% consensus), or "needs group discussion" (defined by < 70% consensus). Certain items were also discussed with multidisciplinary team members from colorectal surgery, oncology and pathology. RESULTS: After completion of the questionnaire, 16 (72%) items required further discussion (< 70% consensus). Following group discussion, consensus was achieved for 21 (95%) of the items. Based on the consensus meeting, a revised structured report was developed. The most significant modifications included (1) Exclusion of the T2/early T3 category; (2) Replacement of the term "circumferential resection margin (CRM)" with "mesorectal fascia (MRF)"; (3) A revised definition of "mucinous content"; (4) Creation of two distinct categories for suspicious lymph nodes (LNs) and tumor deposits; and (5) Classification of suspicious extra-mesorectal LNs by anatomic location. CONCLUSION: The SAR DFP on Rectal and Anal Cancer recommends using this newly updated reporting template for primary MRI staging of rectal cancer.


Sujet(s)
Tumeurs de l'anus , Tumeurs du rectum , Humains , Tumeurs de l'anus/imagerie diagnostique , Tumeurs de l'anus/anatomopathologie , Imagerie par résonance magnétique/méthodes , Stadification tumorale , Tumeurs du rectum/imagerie diagnostique , Tumeurs du rectum/anatomopathologie , Tumeurs du rectum/chirurgie
9.
Eur Radiol ; 32(6): 4025-4033, 2022 Jun.
Article de Anglais | MEDLINE | ID: mdl-35080646

RÉSUMÉ

OBJECTIVES: To evaluate the effect of hepatic metastatic lesion size on inter-reader reproducibility of CT-based 2D radiomics imaging features. METHODS: Computerized tomography (CT) scans of 59 liver metastases from 34 patients with colorectal cancer were evaluated. Image segmentation was performed manually by three readers blinded to each other's results. For each radiomics feature, we created two datasets by sorting measurements according to size, i.e., (i) from the smallest to the largest lesion and (ii) from the largest to the smallest lesion. The Lin concordance correlation coefficient (CCC) was employed to analyze the reproducibility of radiomics features. In particular, the CCC was computed as a function of a number of elements in the dataset, by gradually adding lesions from each sorted dataset. To evaluate the effect of lesion size, we analyzed the difference between these two functions thus assessing the contribution of small and large lesions into the reproducibility of radiomics features. RESULTS: Inter-reader reproducibility of CT-based 2D radiomics features assessed using Lin's CCC demonstrates tumor-size dependence. For example, the Lin CCC for GLCM contrast equals 0.88 (95% C.I. 0.84 to 0.92, p < 0.003) and could change by an additional + / - 0.06 depending on the presence of large or small lesions. CONCLUSIONS: Groups of "large" and "small" lesions show different inter-reader reproducibility. The inter-reader reproducibility from the mixed group consisting of "large" and "small" lesions depends on the lesion-size distribution and can vary widely. This finding could partially explain variability in reproducibility of radiomics features in the literature. KEY POINTS: • Groups of "large" and "small" lesions show different inter-reader reproducibility. • The inter-reader reproducibility from the mixed group consisting of "large" and "small" lesions depends on the lesion-size distribution.


Sujet(s)
Tumeurs du sein , Tumeurs du foie , Femelle , Humains , Tumeurs du foie/imagerie diagnostique , Reproductibilité des résultats , Tomodensitométrie/méthodes
10.
Adv Clin Radiol ; 4(1): 189-194, 2022 Sep.
Article de Anglais | MEDLINE | ID: mdl-37521426

RÉSUMÉ

The 2019 novel coronavirus (COVID-19) pandemic has posed unique, sudden challenges to health care systems. This is true particularly in the context of ultrasound logistics given the risks of inherent prolonged close contact of patients with sonographers and equipment during sonographic image acquisition. We describe the adaptations and modifications in scheduling, workflow, and imaging protocols implemented in our radiology department ultrasound division (a large urban academic center). The hierarchy of controls to minimize exposures to occupational hazards to protect workers, outlined by The National Institute for Occupational Safety and Health (NIOSH) are listed from most effective to least effective: elimination, substitution, engineering controls, administrative controls, and PPE (personal protective equipment (PPE)). Most of the mitigation techniques used in the ultrasound department to reduce hazards to workers involved administrative controls and PPE. We reduced preventable risks by using sterile precautions, imaging triage, and strategically minimizing image acquisition times. These implementations provide a modifiable framework for rapid adaptation during the evolving COVID-19 pandemic, including resurgences of variant strains. This framework ensures a level of preparedness for possible future pandemics or other widespread emergencies.

11.
Radiol Case Rep ; 16(9): 2742-2745, 2021 Sep.
Article de Anglais | MEDLINE | ID: mdl-34377222

RÉSUMÉ

Splenosis is acquired ectopic splenic tissue, usually a sequela of trauma. Its imaging appearance is can be deceiving, and at unusual locations may be mistaken for an alternate cause mass lesion. We present one such unusual case of splenosis in a 53 year-old man with history of heart failure involving the thoracic cavity identified as splenosis on nuclear medicine imaging and suspicion was raised given the remote history splenectomy after splenic rupture during trauma. We will discuss the imaging appearances of splenosis on CT, MRI and nuclear medicine studies, with emphasis on using nuclear medicine as a modality of choice to avoid biopsy. We will also go on to include a brief review of literature on this topic in this article. The key facts are role of detailed clinical history and requirement of high index of suspicion to avoid unnecessary intervention in the case of splenosis.

12.
Ann Otol Rhinol Laryngol ; 130(9): 1044-1051, 2021 Sep.
Article de Anglais | MEDLINE | ID: mdl-33554632

RÉSUMÉ

OBJECTIVES: Three-dimensional printed models created on a consumer level printer can be used to practice mastoidectomy and to discern mastoidectomy experience level. Current models in the literature for mastoidectomy are limited by expense or operability. The aims of this study were (1) to investigate the utility of an inexpensive model for mastoidectomy and (2) to assess whether the model can be used as an evaluation tool to discern the experience level of the surgeon performing mastoidectomy. METHODS: Three-dimensional printed temporal bone models from the CT scan of a 7-year old patient were created using a consumer-level stereolithography 3D printer for a raw material cost of $10 each. Mastoidectomy with facial recess approach was performed by 4 PGY-2 residents, 4 PGY-5 residents, and 4 attending surgeons on the models who then filled out an evaluation. The drilled models were collected and then graded in a blinded fashion by 6 attending otolaryngologists. RESULTS: Both residents and faculty felt the model was useful for training (mean score 4.7 out of 5; range: 4-5) and case preparation (mean score: 4.3; range: 3-5). Grading of the drilled models revealed significant differences between junior resident, senior resident, and attending surgeon scores (P = .012) with moderate to excellent interrater agreement (ICC = 0.882). CONCLUSION: The described operable model that is patient-specific was rated favorably for pediatric mastoidectomy case preparation and training by residents and faculty. The model may be used to differentiate between experience levels and has promise for use in formative and summative evaluations.


Sujet(s)
Compétence clinique , Mastoïdectomie/enseignement et éducation , Impression tridimensionnelle , Formation par simulation , Os temporal , Enfant , Humains , Procédures de chirurgie otologique/enseignement et éducation
13.
Radiographics ; 41(1): 78-95, 2021.
Article de Anglais | MEDLINE | ID: mdl-33306452

RÉSUMÉ

Gallbladder carcinoma is the most common cancer of the biliary system. It is challenging to diagnose because patients are often asymptomatic or present with nonspecific symptoms that mimic common benign diseases. Surgical excision is the only curative therapy and is best accomplished at early non-locally advanced stages. Unfortunately, gallbladder cancer often manifests at late locally advanced stages, precluding cure. Early tumors are often incidentally detected at imaging or at cholecystectomy performed for another indication. Typical imaging features of localized disease include asymmetric gallbladder wall thickening, polyps larger than 1.0 cm, and a solid mass replacing the gallbladder lumen. Advanced tumors are often infiltrative and can be confusing at CT and MRI owing to their large size. Determination of the origin of the lesion is paramount to narrow the differential diagnosis but is often challenging. It is important to identify gallbladder cancer and distinguish it from other benign and malignant hepatobiliary processes. Since surgical resection is the only curative treatment option, radiologist understanding and interpretation of pathways of nodal and infiltrative tumor spread can direct surgery or preclude patients who may not benefit from surgery. While both CT and MRI are effective, MRI provides superior soft-tissue characterization of the gallbladder and biliary tree and is a useful imaging tool for diagnosis, staging, and evaluation of treatment response. ©RSNA, 2020.


Sujet(s)
Tumeurs de la vésicule biliaire , Cholécystectomie , Diagnostic différentiel , Vésicule biliaire , Tumeurs de la vésicule biliaire/imagerie diagnostique , Tumeurs de la vésicule biliaire/chirurgie , Humains , Imagerie par résonance magnétique , Radiologues
14.
Abdom Radiol (NY) ; 45(12): 4073-4083, 2020 12.
Article de Anglais | MEDLINE | ID: mdl-32248258

RÉSUMÉ

Definitive therapy for prostate cancer includes radical prostatectomy and radiation therapy. Treatment is elected based on patient preference, biological tumor factors, and underlying health. Post prostatectomy, men are surveyed for disease recurrence with serial PSA measurements, digital rectal exam, and imaging studies depending on nomogram predicted risk of local disease recurrence and distant metastasis. In men with rising PSA levels, pathologically incomplete surgical margins or, if symptoms of metastasis develop, imaging may be obtained to localize disease. In cases of known biochemical recurrence, imaging is used to target biopsy, to contour in salvage radiation therapy and to assess disease response. For local disease recurrence, the most commonly performed exams are pelvic MRI and transrectal US. CT can evaluate for lymph node metastasis, but is suboptimal in the evaluation of the prostatectomy bed. PET/CT and PET/MRI have been used successfully to evaluate for local disease recurrence. The PI-RADSv2.1 manual provides a risk level and lexicon for use in description of prostate carcinoma prior to prostatectomy, but does not address imaging features post-surgery. A detailed description of nodal, bony, and visceral metastasis is given elsewhere. This manuscript outlines the context in which appropriate imaging exams may be obtained and focuses on imaging findings concerning for local disease recurrence after prostatectomy on various imaging modalities including CT, US, MRI, and PET.


Sujet(s)
Tomographie par émission de positons couplée à la tomodensitométrie , Tumeurs de la prostate , Humains , Mâle , Récidive tumorale locale/imagerie diagnostique , Antigène spécifique de la prostate , Prostatectomie , Tumeurs de la prostate/imagerie diagnostique , Tumeurs de la prostate/chirurgie
15.
Abdom Radiol (NY) ; 45(7): 2143-2153, 2020 07.
Article de Anglais | MEDLINE | ID: mdl-32047994

RÉSUMÉ

Multi-parametric prostate MRI (mpMRI) plays a critical role in the diagnosis, staging, and evaluation of treatment response in patients with prostate cancer. Radiologists, through an accurate and standardized interpretation of mpMRI, can clinically stage prostate cancer and help to risk stratify patients who may benefit from more invasive treatment or exclude patients who may be harmed by overtreatment. The purpose of this article is to describe key findings to accurately stage prostate cancer with mpMRI and to describe the contexts in which mpMRI is best applied.


Sujet(s)
Imagerie par résonance magnétique multiparamétrique , Tumeurs de la prostate , Humains , Imagerie par résonance magnétique , Mâle , Tumeurs de la prostate/imagerie diagnostique
16.
Neurosurg Focus ; 47(6): E12, 2019 12 01.
Article de Anglais | MEDLINE | ID: mdl-31786547

RÉSUMÉ

OBJECTIVE: Advances in 3-dimensional (3D) printing technology permit the rapid creation of detailed anatomical models. Integration of this technology into neurosurgical practice is still in its nascence, however. One potential application is to create models depicting neurosurgical pathology. The goal of this study was to assess the clinical value of patient-specific 3D printed models for neurosurgical planning and education. METHODS: The authors created life-sized, patient-specific models for 4 preoperative cases. Three of the cases involved adults (2 patients with petroclival meningioma and 1 with trigeminal neuralgia) and the remaining case involved a pediatric patient with craniopharyngioma. Models were derived from routine clinical imaging sequences and manufactured using commercially available software and hardware. RESULTS: Life-sized, 3D printed models depicting bony, vascular, and neural pathology relevant to each case were successfully manufactured. A variety of commercially available software and hardware were used to create and print each model from radiological sequences. The models for the adult cases were printed in separate pieces, which had to be painted by hand, and could be disassembled for detailed study, while the model for the pediatric case was printed as a single piece in separate-colored resins and could not be disassembled for study. Two of the models were used for patient education, and all were used for presurgical planning by the surgeon. CONCLUSIONS: Patient-specific 3D printed models are useful to neurosurgical practice. They may be used as a visualization aid for surgeons and patients, or for education of trainees.


Sujet(s)
Imagerie tridimensionnelle/méthodes , Modèles anatomiques , Neurochirurgie/enseignement et éducation , Médecine de précision/méthodes , Soins préopératoires/méthodes , Impression tridimensionnelle , Adénocarcinome , Sujet âgé , Enfant d'âge préscolaire , Angiographie par tomodensitométrie , Fosse crânienne postérieure/imagerie diagnostique , Craniopharyngiome/imagerie diagnostique , Craniopharyngiome/chirurgie , Femelle , Humains , Imagerie par résonance magnétique , Mâle , Tumeurs des méninges/imagerie diagnostique , Tumeurs des méninges/chirurgie , Méningiome/imagerie diagnostique , Méningiome/chirurgie , Adulte d'âge moyen , Seconde tumeur primitive/imagerie diagnostique , Seconde tumeur primitive/chirurgie , Neuroimagerie , Tumeurs de l'hypophyse/imagerie diagnostique , Tumeurs de l'hypophyse/chirurgie , Tumeurs de la prostate , Névralgie essentielle du trijumeau/imagerie diagnostique , Névralgie essentielle du trijumeau/étiologie , Névralgie essentielle du trijumeau/chirurgie
17.
Laryngoscope ; 129(10): 2239-2243, 2019 10.
Article de Anglais | MEDLINE | ID: mdl-30776098

RÉSUMÉ

OBJECTIVE: Posterior glottic stenosis (PGS) often requires a destructive surgical treatment. Early PGS treatment involves glottic dilation to reduce airway constriction associated with chronic PGS. Round laryngeal dilation may not optimize posterior glottic dilation due to the teardrop shape of the glottis and may injure vocal fold tissue. We compared pressure applied to the glottis during traditional single balloon dilation and a novel, anatomically appropriate dilation technique (teardrop-shaped glottic dilation [TSGD]). METHODS: Pressure sensors were affixed at various points on a three-dimensional printed glottic model. The anterior glottis was stented with a triangular stent (18-32F) in combination with balloon dilator (10-20 mm) placed in the posterior glottis (TSGD) in 30 unique combinations. Force applied to the vocal folds (VF) and posterior commissure (PC) during round balloon dilation and TSGD was measured. RESULTS: Dilatory force in the PC ranged from 0.0-3.8 newtons (N) using balloon dilators and 0.0-17.5 N using TSGD. The TSGD technique yielded a superior ratio of force applied to the PC versus VF (P = 0.0296) compared to round balloon dilation alone. Optimal targeting of the PC occurred when the sum of the anteroposterior (AP) dimensions of the stent and balloon dilator approached the AP length of the glottis. CONCLUSION: Use of an anatomically appropriate glottic dilation maximizes expansive force applied to the posterior commissure and decreased force to the vocal folds. This study demonstrates that TSGD minimizes force to the anterior glottis and maximizes dilation of the posterior glottis. This technique may play a role in preventing laryngeal stenosis associated with chronic PGS. LEVEL OF EVIDENCE: NA Laryngoscope, 129:2239-2243, 2019.


Sujet(s)
Obstruction des voies aériennes/chirurgie , Dilatation/méthodes , Glotte/chirurgie , Laryngoscopie/méthodes , Laryngosténose/chirurgie , Obstruction des voies aériennes/étiologie , Obstruction des voies aériennes/anatomopathologie , Dilatation/instrumentation , Glotte/anatomopathologie , Humains , Laryngoscopie/instrumentation , Laryngosténose/complications , Laryngosténose/anatomopathologie , Larynx/chirurgie , Modèles anatomiques , Pression , Impression tridimensionnelle
19.
AJR Am J Roentgenol ; 210(1): 108-112, 2018 Jan.
Article de Anglais | MEDLINE | ID: mdl-29091009

RÉSUMÉ

OBJECTIVE: The purpose of this study was to develop an evidence-based method to optimize prostate MRI reports that would improve communication between urologists and radiologists. MATERIALS AND METHODS: This quality improvement initiative was approved by the institutional Quality Improvement Review Committee. A structured report was developed containing essential components defined by local practice norms and Prostate Imaging Reporting and Data System (PI-RADS) lexicon version 2. Two hundred preintervention and 100 postintervention reports were retrospectively reviewed for essential components. Additionally, a sample of 40 reports generated before the intervention and 40 reports generated after the intervention that made use of the structured report were evaluated by a urologist and were scored on a 5-point scale for consistency, completeness, conciseness, clarity, likelihood to contact radiologist, and clinical impact. Variables were compared with ANOVA, chi-square, or Fisher exact test. RESULTS: Essential components of the report were utilization of the PI-RADSv2 lexicon, findings listed by lesion, reporting of pertinent positive and negative findings (extraprostatic extension, seminal vesicle, and neurovascular bundle invasion), and low word count. In postintervention reports, all essential measures were statistically improved except for mean report word count. The urologist indicated statistically improved consistency (before intervention, 2.7; after intervention, 3.5; χ2 < 0.001), completeness (before intervention, 2.8; after intervention, 3.3; χ2 < 0.001), clarity (before intervention, 2.9; after intervention, 3.3; χ2 < 0.05), and clinical impact (before intervention, 2.8; after intervention, 3.8; χ2 < 0.001) of the report with reduced perceived need to contact (before intervention, 3.2; after intervention, 2.1; χ2 < 0.001) the interpreting radiologist for explanation. CONCLUSION: The structured prostate MRI report resulted in improved communication with referring urologists as indicated by the increased perceived clinical impact of the report.


Sujet(s)
Communication , Médecine factuelle , Imagerie par résonance magnétique , Maladies de la prostate/imagerie diagnostique , Orientation vers un spécialiste , Urologie , Humains , Mâle , Amélioration de la qualité , Systèmes d'information de radiologie
SÉLECTION CITATIONS
DÉTAIL DE RECHERCHE
...