Your browser doesn't support javascript.
loading
Montrer: 20 | 50 | 100
Résultats 1 - 7 de 7
Filtrer
Plus de filtres











Base de données
Gamme d'année
1.
Electrophoresis ; 2024 Jul 25.
Article de Anglais | MEDLINE | ID: mdl-39049673

RÉSUMÉ

We present a follow-on technique for the cyclic-immunofluorescence profiling of suspension particles isolated using dielectrophoresis. The original lab-on-chip technique ("cyc-DEP" [cyclic immunofluorescent imaging on dielectrophoretic chip]) was designed for the multiplex surveillance of circulating biomarkers. Nanoparticles were collected from low-volume liquid biopsies using microfluidic dielectrophoretic chip technology. Subsequent rounds of cyclic immunofluorescent labeling and quenching were imaged and quantified with a custom algorithm to detect multiple proteins. While cyc-DEP improved assay multiplicity, long runtimes threatened its clinical adoption. Here, we modify the original cyc-DEP platform to reduce assay runtimes. Nanoparticles were formulated from human prostate adenocarcinoma cells and collected using dielectrophoresis. Three proteins were labeled on-chip with a mixture of short oligonucleotide-conjugated antibodies. The sample was then incubated with complementary fluorophore-conjugated oligonucleotides, which were dehybridized using an ethylene carbonate buffer after each round of imaging. Oligonucleotide removal exhibited an average quenching efficiency of 98 ± 3% (n = 12 quenching events), matching the original cyc-DEP platform. The presented "oligo cyc-DEP" platform achieved clinically relevant sample-to-answer times, reducing the duration for three rounds of cyclic immunolabeling from approximately 20 to 6.5 h-a 67% decrease attributed to rapid fluorophore removal and the consolidated co-incubation of antibodies.

2.
Electrophoresis ; 43(16-17): 1784-1798, 2022 09.
Article de Anglais | MEDLINE | ID: mdl-35753078

RÉSUMÉ

Cancer is a highly heterogenous disease that requires precise detection tools and active surveillance methods. Liquid biopsy assays provide an agnostic way to follow the complex trajectory of cancer, providing better patient stratification tools for optimized treatment. Here, we present the development of a low-volume liquid biopsy assay called cyc-DEP (cyclic immunofluorescent imaging on dielectrophoretic chip) to profile biomarkers collected on a dielectrophoretic microfluidic chip platform. To enable on-chip cyclic imaging, we optimized a fluorophore quenching method and sequential rounds of on-chip staining with fluorescently conjugated primary antibodies. cyc-DEP allows for the quantification of a multiplex array of proteins using 25 µl of a patient plasma sample. We utilized nanoparticles from a prostate adenocarcinoma (LNCaP) cell line and a panel of six target proteins to develop our proof-of-concept technique. We then used cyc-DEP to quantify blood plasma levels of target proteins from healthy individuals, low-grade and high-grade prostate cancer patients (n = 3 each) in order to demonstrate that our platform is suitable for liquid biopsy analysis in its present form. To ensure accurate quantification of signal intensities and comparisons between different samples, we incorporated a signal intensity normalization method (fluorescent beads) and a custom signal intensity quantification algorithm that account for the distribution of signal across hundreds of collection regions on each chip. Our technique enabled a threefold improvement in multiplicity for detecting proteins associated with fluid samples, opening doors for early detection, and active surveillance through quantification of a multiplex array of biomarkers from low-volume liquid biopsies.


Sujet(s)
Dosage biologique , Microfluidique , Électrophorèse/méthodes , Technique d'immunofluorescence , Humains , Coloration et marquage
3.
Lab Chip ; 21(7): 1318-1332, 2021 04 07.
Article de Anglais | MEDLINE | ID: mdl-33877235

RÉSUMÉ

Tumor-secreted exosomes and other extracellular vesicles (EVs) in circulation contain valuable biomarkers for early cancer detection and screening. We have previously demonstrated collection of cancer-derived nanoparticles (NPs) directly from whole blood and plasma with a chip-based technique that uses a microelectrode array to generate dielectrophoretic (DEP) forces. This technique enables direct recovery of NPs from whole blood and plasma. The biomarker payloads associated with collected particles can be detected and quantified with immunostaining. Accurately separating the fluorescence intensity of stained biomarkers from background (BG) levels becomes a challenge when analyzing the blood from early-stage cancer patients in which biomarker concentrations are low. To address this challenge, we developed two complementary techniques to standardize the quantification of fluorescently immunolabeled biomarkers collected and concentrated at predictable locations within microfluidic chips. The first technique was an automated algorithm for the quantitative analysis of fluorescence intensity at collection regions within the chip compared to levels at adjacent regions. The algorithm used predictable locations of particle collection within the chip geometry to differentiate regions of collection and BG. We successfully automated the identification and removal of optical artifacts from quantitative calculations. We demonstrated that the automated system performs nearly the same as a human user following a standard protocol for manual artifact removal with Pearson's r-values of 0.999 and 0.998 for two different biomarkers (n = 36 patients). We defined a usable dynamic range of fluorescence intensities corresponding to 1 to 2000 arbitrary units (a.u.). Fluorescence intensities within the dynamic range increased linearly with respect to exposure time and particle concentration. The second technique was the implementation of an internal standard to adjust levels of biomarker fluorescence based on the relative collection efficiency of the chip. Use of the internal standard reduced variability in measured biomarker levels due to differences in chip-to-chip collection efficiency, especially at low biomarker concentrations. The internal standard did not affect linear trends between fluorescence intensity and exposure time. Adjustments using the internal standard improved linear trends between fluorescence intensity and particle concentration. The optical quantification techniques described in this paper can be easily adapted for other lab-on-a-chip platforms that have predefined regions of biomarker or particle collection and that rely on fluorescence detection.


Sujet(s)
Exosomes , Vésicules extracellulaires , Humains , Laboratoires sur puces , Microfluidique , Plasma sanguin
4.
J Am Coll Nutr ; 38(6): 485-492, 2019 08.
Article de Anglais | MEDLINE | ID: mdl-30964398

RÉSUMÉ

Objective: To examine resting and postprandial peripheral protease activity in healthy controls and individuals with type 2 diabetes mellitus (T2DM) and pre-T2DM. Methods: Individuals with T2DM or pre-T2DM and healthy controls (mean age 55.8 years) were studied before and for a span of 300 minutes following a single high-calorie McDonald's breakfast. Metalloproteases-2/-9 (MMP-2/-9), elastase, and trypsin activities were assessed in whole blood before and following the meal using a novel high-precision electrophoretic platform. Also assessed were circulating levels of inflammatory biomarkers and insulin receptor density on peripheral blood mononuclear cells (PBMCs) in relationship to protease activity. Results: Premeal MMP-2/-9 and elastase activity levels in T2DM and in pre-T2DM participants were significantly elevated as compared to controls. The T2DM group showed a significant increase in elastase activity 15 minutes after the meal; elastase activity continued to increase to the 30-minute time point (p < 0.01). In control participants, MMP-2/-9, elastase, and trypsin were significantly increased at 15 minutes after the meal (p < 0.05) and returned to premeal values within a period of approximately 30 to 60 minutes post meal. PBMCs incubated for 1 hour with plasma from T2DM and pre-T2DM participants had significantly lower levels of insulin receptor density compared to those incubated with plasma from control participants (p < 0.001). Conclusions: The results of this study suggest that individuals with T2DM and pre-T2DM have higher resting systemic protease activity than nonsymptomatic controls. A single high-calorie/high-carbohydrate meal results in further elevations of protease activity in the systemic circulation of T2DM and pre-T2DM, as well as in healthy controls. The protease activity in turn can lead to a downregulation of insulin receptor density, potentially supporting a state of insulin resistance.


Sujet(s)
Diabète de type 2 , Peptide hydrolases/sang , Période post-prandiale/physiologie , Récepteur à l'insuline , Diabète de type 2/sang , Diabète de type 2/épidémiologie , Diabète de type 2/physiopathologie , Femelle , Humains , Mâle , Adulte d'âge moyen , Récepteur à l'insuline/sang , Récepteur à l'insuline/métabolisme , Repos/physiologie
5.
Electrophoresis ; 37(15-16): 2248-56, 2016 08.
Article de Anglais | MEDLINE | ID: mdl-27271700

RÉSUMÉ

Present coagulation assays fail to detect mild coagulation disorders, while thrombin-generation (TG) assays solve this problem. However, most of them only work with threated blood samples, which makes them labor intensive, time consuming, unreliable, and expensive. We have developed a TG electrophoretic assay that uses a thrombin specific charge-changing fluorescent peptide substrate, electrophoretic separation, and requires a drop of blood. The limit of detection of the assay was 1.97 nM in phosphate buffer saline and 6.82 nM in citrated whole blood. The assay was used to determine the TG in whole blood from healthy volunteers (n = 6, one aspirin user), over 30 min, after the blood was drawn; the TG increased from a baseline level of 2 × 10(6) RFU to 1.2 × 10(13) RFU. The lag time between the blood draw and initial burst of TG was 6 min for the volunteers (n = 5) and 15 min for the aspirin user. Specificity of the assay was evaluated by reacting our substrate with the heparinized blood samples and other proteases. The TG electrophoretic assay was designed and tested in the whole human blood, requiring no sample preparation, 5 µL of blood, 45 min, and it detected differences in coagulation patterns between a volunteer taking aspirin and non-aspirin users.


Sujet(s)
Tests de coagulation sanguine/méthodes , Électrophorèse/méthodes , Acide acétylsalicylique/pharmacologie , Coagulation sanguine/effets des médicaments et des substances chimiques , Humains , Limite de détection , Sensibilité et spécificité , Temps de thrombine
6.
PLoS One ; 9(5): e96408, 2014.
Article de Anglais | MEDLINE | ID: mdl-24788791

RÉSUMÉ

Matrix metalloproteinase-9 is elevated within the acutely injured murine spinal cord and blockade of this early proteolytic activity with GM6001, a broad-spectrum matrix metalloproteinase inhibitor, results in improved recovery after spinal cord injury. As matrix metalloproteinase-9 is likewise acutely elevated in dogs with naturally occurring spinal cord injuries, we evaluated efficacy of GM6001 solubilized in dimethyl sulfoxide in this second species. Safety and pharmacokinetic studies were conducted in naïve dogs. After confirming safety, subsequent pharmacokinetic analyses demonstrated that a 100 mg/kg subcutaneous dose of GM6001 resulted in plasma concentrations that peaked shortly after administration and were sustained for at least 4 days at levels that produced robust in vitro inhibition of matrix metalloproteinase-9. A randomized, blinded, placebo-controlled study was then conducted to assess efficacy of GM6001 given within 48 hours of spinal cord injury. Dogs were enrolled in 3 groups: GM6001 dissolved in dimethyl sulfoxide (n = 35), dimethyl sulfoxide (n = 37), or saline (n = 41). Matrix metalloproteinase activity was increased in the serum of injured dogs and GM6001 reduced this serum protease activity compared to the other two groups. To assess recovery, dogs were a priori stratified into a severely injured group and a mild-to-moderate injured group, using a Modified Frankel Scale. The Texas Spinal Cord Injury Score was then used to assess long-term motor/sensory function. In dogs with severe spinal cord injuries, those treated with saline had a mean motor score of 2 (95% CI 0-4.0) that was significantly (P<0.05; generalized linear model) less than the estimated mean motor score for dogs receiving dimethyl sulfoxide (mean, 5; 95% CI 2.0-8.0) or GM6001 (mean, 5; 95% CI 2.0-8.0). As there was no independent effect of GM6001, we attribute improved neurological outcomes to dimethyl sulfoxide, a pleotropic agent that may target diverse secondary pathogenic events that emerge in the acutely injured cord.


Sujet(s)
Dipeptides/administration et posologie , Maladies des chiens/traitement médicamenteux , Déplacement de disque intervertébral/médecine vétérinaire , Inhibiteurs de métalloprotéinases matricielles/administration et posologie , Traumatismes de la moelle épinière/médecine vétérinaire , Animaux , Diméthylsulfoxyde/administration et posologie , Dipeptides/effets indésirables , Dipeptides/pharmacocinétique , Maladies des chiens/sang , Maladies des chiens/anatomopathologie , Chiens , Méthode en double aveugle , Association de médicaments , Régulation de l'expression des gènes/effets des médicaments et des substances chimiques , Déplacement de disque intervertébral/sang , Déplacement de disque intervertébral/traitement médicamenteux , Déplacement de disque intervertébral/anatomopathologie , Inhibiteurs de métalloprotéinases matricielles/effets indésirables , Inhibiteurs de métalloprotéinases matricielles/pharmacocinétique , Matrix metalloproteinases/sang , Traumatismes de la moelle épinière/sang , Traumatismes de la moelle épinière/traitement médicamenteux , Traumatismes de la moelle épinière/anatomopathologie
7.
Physiol Rep ; 1(5): e00109, 2013 Oct.
Article de Anglais | MEDLINE | ID: mdl-24303180

RÉSUMÉ

The small intestine plays a key role in the pathogenesis of multiple organ failure following circulatory shock. Current results show that reduced perfusion of the small intestine compromises the mucosal epithelial barrier, and the intestinal contents (including pancreatic digestive enzymes and partially digested food) can enter the intestinal wall and transport through the circulation or mesenteric lymph to other organs such as the lung. The extent to which the luminal contents of the small intestine mediate tissue damage in the intestine and lung is poorly understood in shock. Therefore, rats were assigned to three groups: No-hemorrhagic shock (HS) control and HS with or without a flushed intestine. HS was induced by reducing the mean arterial pressure (30 mmHg; 90 min) followed by return of shed blood and observation (3 h). The small intestine and lung were analyzed for hemorrhage, neutrophil accumulation, and cellular membrane protein degradation. After HS, animals with luminal contents had increased neutrophil accumulation, bleeding, and destruction of E-cadherin in the intestine. Serine protease activity was elevated in mesenteric lymph fluid collected from a separate group of animals subjected to intestinal ischemia/reperfusion. Serine protease activity was elevated in the plasma after HS but was detected in lungs only in animals with nonflushed lumens. Despite removal of the luminal contents, lung injury occurred in both groups as determined by elevated neutrophil accumulation, permeability, and lung protein destruction. In conclusion, luminal contents significantly increase intestinal damage during experimental HS, suggesting transport of luminal contents across the intestinal wall should be minimized.

SÉLECTION CITATIONS
DÉTAIL DE RECHERCHE