1.
Mikrochim Acta ; 191(1): 24, 2023 12 13.
Article de Anglais | MEDLINE | ID: mdl-38091091

RÉSUMÉ

A novel determination method for protein biomarkers based on on-chip flow rate measurement was developed using a microchip with organic photodiodes (OPDs). This quantitative method is based on the flow rate measurement of an ink solution pushed out by oxygen gas generated through catalase reaction. The amount of oxygen gas generated in the sample reservoir is dependent on the concentration of the analyte; therefore, the flow rate of the ink solution is also dependent on the concentration of the analyte. The concentration of the analyte can thus be estimated by measurement of the ink solution flow rate. The ink solution flow rate was estimated by measuring the migration time of the ink solution between two points using two OPDs placed below the microchannel. The principle of this method was demonstrated by the measurement of catalase using the microchip. In addition, the developed method was applied to the determination of C-reactive protein (CRP), a biomarker of inflammation, based on a catalase-linked immunosorbent assay (C-LISA). The limit of detection for CRP was 0.20 µg/mL. The method was also applied to the determination of CRP in human serum, and the quantitative values obtained by this method were in excellent agreement with those obtained by the conventional enzyme-linked immunosorbent assay (ELISA) method. The developed method does not require a photodetector with high sensitivity and is thus capable of downsizing; therefore, this will be useful for on-site analyses such as point-of-care testing and field measurements.


Sujet(s)
Protéine C-réactive , Oxygène , Humains , Protéine C-réactive/analyse , Catalase , Encre , Marqueurs biologiques
2.
Talanta ; 256: 124311, 2023 May 01.
Article de Anglais | MEDLINE | ID: mdl-36738624

RÉSUMÉ

A small-sized fluorescence detector (referred to as a pipette tip [PT]-reader) was developed for a pipette tip-based biosensor. The PT-reader allows us to measure the fluorescence intensity of a solution in a truncated cone-shaped pipette tip with only the tip inserted into the PT-reader. A pipette holder made from a mixture of polydimethylsiloxane (PDMS) and carbon black was capable of the rigorous position arrangement of a truncated cone shaped-pipette tip and the prevention of stray light. The detection performance of the PT-reader was evaluated by measurement of resorufin. The limit of detection (LOD; 3σ) and the relative standard deviation (RSD, n = 4) were estimated to be 0.46 µM and 0.47-4.1%, respectively. This performance was comparable to that of a desktop-type fluorescence microplate reader. In addition, the PT-reader was applied to the quantification of immunoglobulin A (IgA), and the LOD (3σ) of IgA was estimated to be 1.0 ng/mL. The quantitation values of IgA in human saliva obtained by the PT-based enzyme-linked immunosorbent assay (PT-ELISA) were in agreement with those obtained by conventional ELISA. The PT-reader is expected to be useful for low-cost and user-friendly measurements, and the technique of device development proposed in this study will contribute to the progress of on-site medical diagnosis.


Sujet(s)
Techniques de biocapteur , Humains , Test ELISA
3.
Anal Sci ; 39(3): 375-381, 2023 Mar.
Article de Anglais | MEDLINE | ID: mdl-36577893

RÉSUMÉ

Hydrophilic interaction chromatography (HILIC)-type sorbents were newly developed for the solid-phase extraction (SPE) of polar compounds. Two methacrylate-base resins with different cross-linking monomers and pore properties were synthesized, and three polyethyleneimines (PEIs) with different molecular weights were modified onto each base resin. In both cases, PEIs with a molecular weight of 10,000 (PEI-10,000) exhibited the highest adsorption properties for polar compounds (uracil, uridine, adenosine, cytidine, and guanosine). To control the water-enriched layer at the surface of the PEI-10,000-modified sorbents, the additive amount of PEI-10,000 in the modified reaction was also optimized. When 10 times the amount of PEI-10,000 to each base resin was added, an improvement in adsorption property was observed. Moreover, the use of a nonaqueous sample solution (100% acetonitrile) during the sample loading process drastically improved adsorption, especially for uracil (about 80%) and adenosine (100%). These results indicate that the formation of a strong water-enriched layer at the surface of sorbents with an effective expression of hydrophilic interaction was an important factor in the adsorption properties of polar compounds in HILIC mode-SPE.

4.
Biosens Bioelectron ; 218: 114788, 2022 Dec 15.
Article de Anglais | MEDLINE | ID: mdl-36242903

RÉSUMÉ

Affordable methods for ultra-sensitive biomarkers detection may improve the standard of living in resource-constrained countries. Nanowire biosensor is preponderant in ultra-sensitive protein detection. However, current strategies for nanowire sensor (NWS) fabrication often require sophisticated instruments, being inaccessible in less-resourced laboratories. Herein, we circumvent this challenge by developing a simple methodology, localized hydrodynamic flow confinement assisted nanowire sensor fabrication, enable the detection with limits of detection (LOD) for IgA and IgG measurement were 0.089 fg/mL and 0.93 fg/mL, respectively, demonstrating a 10-fold increase in detection sensitivity compared with the published NWS. Noteworthy, an X-Y positioner combined with a homemade microchemical pen (MCP) for tunable chemical deposition were sufficient to complete the fabrication of the nanowire biosensor without other expensive and demanding equipment. Overall, a particularly accessible, competitive, and low-cost approach of nanowire sensor fabrication for ultra-sensitive protein detection was developed, which could widely facilitate the application of nanowire biosensors. Besides, the nanowire sensor can also be employed to detect other analytes of interest by the use of different stimuli-responsive biosystems.


Sujet(s)
Techniques de biocapteur , Nanofils , Techniques de biocapteur/méthodes , Hydrodynamique , Marqueurs biologiques , Immunoglobuline A , Immunoglobuline G
5.
Biosens Bioelectron ; 218: 114791, 2022 Dec 15.
Article de Anglais | MEDLINE | ID: mdl-36242905

RÉSUMÉ

The far-field fluorescence amplification, the intense fluorescence emission addresses the great potential in sensitive detection to large biomolecules, was seriously ignored for the failure in amplifying the weak fluorescence excepting the electromagnetic field (EM) induced fluorescence amplification on the metallic surfaces. Here, a microsphere in hundreds of micrometers was adopted to proceed with the fluorescence amplification via building up a local dielectric surrounding for fluorophore. The wide range of contribution-angle fluorescence could be efficiently restricted within the microsphere by facilitating the energy of reflection restraining and declining the energy of refraction decaying and the intense fluorescence emission confined within the microsphere could be directly observed. The proposed microsphere amplified fluorescence was demonstrated to induce about 2600 times of improved sensitivity in the detection of the fluorescent resorufin referring that of the original resorufin solution through the laser induced fluorescence (LIF). Furthermore, the limit of detection (LOD) of human IgA was successfully obtained to 3.25 fM through the microsphere in 47.7 pL when the microsphere amplified fluorescence was utilized in the fluoroimmunoassay. We believe the microsphere amplified fluorescence would be a potential strategy to implement the sensitive fluorescence sensing.


Sujet(s)
Techniques de biocapteur , Humains , Fluorescence , Microsphères , Limite de détection , Colorants fluorescents , Immunoglobuline A
6.
Chem Commun (Camb) ; 58(27): 4308-4311, 2022 Mar 31.
Article de Anglais | MEDLINE | ID: mdl-35262137

RÉSUMÉ

Gold nanowires are expected to be applied to biosensing due to their advantages, such as high stability and biocompatibility. However, it is still inconvenient to fabricate a single gold nanowire at a precise position, and without a special demanding environment. In this study, we present an open-space laminar flow approach for fabricating a single gold nanowire at a precise position under normal conditions. The fabricated gold nanowire demonstrated excellent biosensing of IgA with an extremely low limit of detection (1 aM).


Sujet(s)
Techniques de biocapteur , Nanofils , Or
7.
Talanta ; 240: 123162, 2022 Apr 01.
Article de Anglais | MEDLINE | ID: mdl-34996015

RÉSUMÉ

A simple and low-cost method of fabricating an optical fiber for a surface plasmon resonance (SPR) sensor was proposed. The method is based on the electroless nickel plating and subsequent displacement gold plating of the core of the optical fiber. The thickness of the nickel and gold thin films deposited on the core of the optical fiber could be controlled by measuring the reflected light intensity from the tip of the optical fiber during the plating processes. The sensitivity and resolution of the SPR sensor with the fabricated optical fiber in the refractive index range from 1.333 to 1.348 were 1324.3 nm/RIU and 7.6 × 10-4 RIU, respectively. The developed SPR sensor was successfully used in the determination of immunoglobulin A (IgA) in human saliva. The IgA quantification results obtained by the SPR sensor were in excellent agreement with those obtained by conventional enzyme-linked immunosorbent assay using a 96-well microtiter plate.


Sujet(s)
Fibres optiques , Résonance plasmonique de surface , Or , Humains , Dosage immunologique , Réfractométrie
8.
Talanta ; 238(Pt 1): 122994, 2022 Feb 01.
Article de Anglais | MEDLINE | ID: mdl-34857327

RÉSUMÉ

We developed a small fluorescence microplate reader with an organic photodiode (OPD) array. The OPD array has nine OPDs that have a large light receiving area (9.62 mm2 per one OPD). Since the OPD array is fabricated on a flat glass plate, it can be placed just below microwells and can detect fluorescence emitted through the entire surface of the microwell bottom. The analytical performance of the developed plate reader was evaluated by measuring an aqueous solution of resorufin. The limit of detection (LOD) for resorufin (0.01-0.05 µM) was lower than that obtained with a plate reader equipped with nine inorganic photodiodes developed in a previous study (0.30 µM) and a commercially available microplate reader (0.16 µM). These results indicate that the large light receiving area improves the detection performance of the system. In addition, the developed reader was successfully used to quantify immunoglobulin A (IgA) in human saliva. The LOD for IgA was estimated to be 1.2 ng/mL, which is low enough to objectively evaluate human stress.


Sujet(s)
Photométrie , Humains , Limite de détection
9.
Anal Chem ; 93(24): 8680-8686, 2021 06 22.
Article de Anglais | MEDLINE | ID: mdl-34107213

RÉSUMÉ

Metabolism of a single cell, even within the same organization, differs from other cells by orders of magnitude. Single-cell analysis provides key information for early diagnosis of cancer as well as drug screening. Any slight change in the microenvironment may affect the state of a single cell. Timely and effective cell monitoring is conducive to better understand the behavior of single cells. The immediate response of a single cell described in this study is a liquid transfer-based approach for real-time electrochemical detection. The cell was in situ stimulated by continuous flow with glucose, and lactate secreted from the cell would diffuse into the microflow. The microflow was aspirated into the detection channel where lactate was then decomposed by coupled enzyme reactions and detected by an electrode. This work provides a novel approach for detecting lactate response from a single cell by noninvasive measurements, and the position resolution of the microfluidic probe reaches the level of a single cell and permits individual heterogeneity in cells to be explored in the diagnosis and treatment of cancer as well as in many other situations.


Sujet(s)
Techniques d'analyse microfluidique , Microfluidique , Électrodes , Glucose , Acide lactique
10.
Anal Chem ; 93(4): 2273-2280, 2021 02 02.
Article de Anglais | MEDLINE | ID: mdl-33443406

RÉSUMÉ

It is well known that cell can response to various chemical and mechanical stimuli. Therefore, flow pressure variation induced by sample loading and elution should be small enough to ignore the physical impact on cells when we use a Chip-SPE-MS system for cells. However, most existent Chip-SPE-MS systems ignored the pressure alternation because it is extremely difficult to develop a homogeneous-flow-pressure hyphenated module. Herein, we developed an interesting fluidic isolation-assisted homogeneous-flow-pressure Chip-SPE-MS system and demonstrated that it is adequate for online high-throughput determination and quantification of the 25-hydroxyvitamin D3 (25(OH)D3) biotransformation in different cells. Briefly, the homogeneous ambient flow pressure is achieved by fluidic isolation between the cell culture channel and the SPE column, and an automatic sampling probe could accomplish the sample loading and dispensing to fulfill online pretreatment of the sample. Through this new system, the expression levels of 24,25-dihydroxyvitamin D3 (24,25(OH)2D3) can be determined in real time with a detection limit of 2.54 nM. In addition, the results revealed that 25(OH)D3 metabolic activity differed significantly between normal L-02 cells and cancerous HepG2 cells. Treatment of L-02 cells with a high dose of 25(OH)D3 was found to increase significant formation of 24,25(OH)2D3, but this change was not apparent in HepG2 cells. The presented system promises to be a versatile tool for online accurate molecule biotransformation investigation and drug screening processes.


Sujet(s)
Calcifédiol/métabolisme , Techniques de culture cellulaire/instrumentation , Laboratoires sur puces , Spectrométrie de masse/méthodes , Microextraction en phase solide/méthodes , Animaux , Biotransformation , Lignée cellulaire , Cytochrome P-450 CYP3A/composition chimique , Cytochrome P-450 CYP3A/métabolisme , Humains , Souris , ARN messager/génétique , ARN messager/métabolisme , Vitamine D3 24-hydroxylase/composition chimique , Vitamine D3 24-hydroxylase/métabolisme
11.
Anal Sci ; 37(4): 625-631, 2021 Apr 10.
Article de Anglais | MEDLINE | ID: mdl-33342923

RÉSUMÉ

An innovative technique is proposed for forming silver thin films of nanometer-order thickness via a silver-mirror reaction. This approach is made possible by the real-time monitoring of the thickness of a silver thin film formed on the edge surface of a fiber core during the silver-mirror reaction using a homemade absorbance measurement system. The monitored absorbance value increases as silver plating progresses, and the relationship between the absorbance values and the thickness of the silver thin film is linear in the thickness range from approximately 30 to 60 nm. This technique was applied to the preparation of a fiber-optic surface plasmon resonance (FO-SPR) sensor. The sensor was successfully used to measure sucrose solutions with concentrations of less than 16% (w/v). The sensitivity of the sensor probe was estimated to be 2205 nm/RIU in the refractive index range of 1.333 - 1.357. The relative standard deviation of the wavelength shift obtained from measurements using different sensor probes was estimated to be less than 3.3%.

12.
RSC Adv ; 10(59): 35848-35855, 2020 Sep 28.
Article de Anglais | MEDLINE | ID: mdl-35517096

RÉSUMÉ

Micro-flow-injection analysis (µFIA) is amenable to high-throughput systems with lower consumption of sample and reagent volumes. On-chip sample injection methods are important to prevent reduced analytical performance associated with dead volumes and diffusion of sample solutions. In this study, we have developed an on-chip sample injection system with a small-sized 6-port valve incorporated on a microchip. The valve is made with a 3D printer and is a simple structure that can be easily operated manually. A sample solution in a loading channel can be injected by switching the valve from the load to injection position. Sample injection tests using resorufin solutions revealed that samples can be injected below 100 µL min-1, and the performance of the sample injection system is comparable to that of a commercially available injector. In addition, the sample injection system was successfully applied to a flow-based assay for hydrogen peroxide. The detection limit (3σ) of hydrogen peroxide was estimated to be 0.5 µM, and the assay time after sample injection was approximately 100 s. The developed sample injection system will be useful for various microfluidic-based analyses including µFIA.

13.
Anal Chem ; 91(9): 5685-5689, 2019 05 07.
Article de Anglais | MEDLINE | ID: mdl-30973223

RÉSUMÉ

The microwell plate/microtiter plate is among the most widely used tools in immune assays. In this paper, we report on a sensitive method for enhancing fluorescence emission detection by simply adding several droplets of an immiscible organic compound into the microwells before detection. To prove the concept, human IgA was determined on a microwell plate using this droplet enhanced fluorescence (DEF) detection method. An obvious enhancement in fluorescence was observed. The detection limit (LOD) was about 1/20 times and the sensitivity was 4 times greater than that without droplets. To prove the use of the method for disease diagnosis, the IgG of measles in human plasma was determined using the proposed DEF method. A LOD of around 1/5 times and a sensitivity of 4 times the DEF were easily achieved compared to ELISA with a conventional fluorescence detection.


Sujet(s)
Fluorescence , Dosage fluoroimmunologique/méthodes , Immunoglobuline G/sang , Virus de la rougeole/isolement et purification , Rougeole/diagnostic , Humains , Limite de détection , Rougeole/sang , Rougeole/virologie
14.
ACS Appl Mater Interfaces ; 10(27): 23247-23253, 2018 Jul 11.
Article de Anglais | MEDLINE | ID: mdl-29923702

RÉSUMÉ

Manipulation of light transmission/absorbance and reflection/emission has a great significance in smart windows and displaying media like liquid crystal. Here, we report the usage of an external electric field to reversibly switch the molecular spectra of a model molecule on the basis of its interaction with an electroresponsible polymer brush. Both the UV-vis absorbance spectrum and the fluorescence emission spectrum of the model molecule were confirmed to be electroswitchable. The electroswitchable spectra were experimentally demonstrated to be induced by the electroswitchable statuses of medium anionic poly-allyloxy hydroxypropyl sulfonate (poly-AHPS) brush. Insightfully, the molecular aggregated status of model proflavine molecules could be electrically controlled via the electroresponsible poly-AHPS brushes and then the molecular spectra of the model proflavine molecule also could be electrically and controllably shifted. The success in the manipulation of molecular spectra opens up a wide range of applications not only for displaying but also for nonlinear optics, in vivo imaging, sensors, and environmental inspection.

15.
Anal Chem ; 90(8): 5329-5334, 2018 04 17.
Article de Anglais | MEDLINE | ID: mdl-29595058

RÉSUMÉ

We report on the development of a novel and flexible online digital polymerase chain reaction (dPCR) system. The system was composed of three parts: an inkjet for generating the droplets, a coiled fused-silica capillary for thermal cycling, and a laser-induced fluorescence detector (LIFD) for positive droplet counting. Upon inkjet printing, monodisperse droplets were continuously generated in the oil phase and then introduced into the capillary in the form of a stable dispersion. The droplets containing one or zero molecules of target DNA passed through the helical capillary that was attached to a cylindrical thermal cycler for PCR amplification, resulting in the generation of fluorescence for the DNA-positive droplet. After 36 PCR cycles, the fluorescence signal intensity was detected by laser-induced fluorescence located at the downstream of the capillary, followed by a positive/negative counting. The present system was successfully applied to the absolute quantification of the HPV sequence in Caski cells with dynamic ranges spanning 4 orders of magnitude.


Sujet(s)
ADN/génétique , Encre , Papillomaviridae/génétique , Réaction de polymérisation en chaîne , Impression (processus) , Lignée cellulaire tumorale , ADN/analyse , Fluorescence , Humains , Taille de particule , Réaction de polymérisation en chaîne/instrumentation , Propriétés de surface
16.
Chem Commun (Camb) ; 54(7): 719-722, 2018 Jan 18.
Article de Anglais | MEDLINE | ID: mdl-29227480

RÉSUMÉ

Elaborately programmed silver nanowire arrays can be prepared using a tapered push-pull nozzle system (TPPNS), which is used to directly write micro-nano wires on a substrate via a two-reagent reaction in the diffusion mixing region. The wires could be precisely positioned on the substrate and their width could be freely controlled from the micro to the nano scale, indicating an advance in the methodologies of controlling and fabricating nanowires. The as-prepared silver three-electrode device can serve as a three-electrode sensor.

17.
Anal Chem ; 89(17): 8674-8677, 2017 09 05.
Article de Anglais | MEDLINE | ID: mdl-28803473

RÉSUMÉ

This study describes a method to investigate the separation of cells by capillary electrophoresis (CE) coupled with inkjet printing system. The results validated the feasibility of inkjet printing for mammalian cells to achieve the drop-on-demand and convenient sampling into capillary then zone electrophoresis was applied to separate different cells according to their electrophoretic mobility, finally the peak signal were measured by UV detector. Linear relationship between the peak area and the droplet number was obtained within the range of 25-400 drops (R2 = 0.996) at a fixed cell concentration 106/mL, indicating that this system could be used for rapid and accurate quantification of cells.


Sujet(s)
Séparation cellulaire/instrumentation , Séparation cellulaire/méthodes , Électrophorèse capillaire/méthodes , Impression (processus)/méthodes , Lignée cellulaire tumorale , Cellules endothéliales de la veine ombilicale humaine , Humains
18.
Sensors (Basel) ; 17(7)2017 Jul 11.
Article de Anglais | MEDLINE | ID: mdl-28696378

RÉSUMÉ

A film-stack reaction field with a micropillar array using a motor stirrer was developed for the high sensitivity and rapid enzyme-linked immunosorbent assay (ELISA) reaction. The effects of the incubation time of a protein (30 s, 5 min, and 10 min) on the fluorescence intensity in ELISAs were investigated using a reaction field with different micropillar array dimensions (5-µm, 10-µm and 50-µm gaps between the micropillars). The difference in fluorescence intensity between the well with the reaction field of 50-µm gap for the incubation time of 30 s and the well without the reaction field with for incubation time of 10 min was 6%. The trend of the fluorescence intensity in the gap between the micro pillars in the film-stack reaction field was different between the short incubation time and the long incubation time. The theoretical analysis of the physical parameters related with the biomolecule transport indicated that the reaction efficiency defined in this study was the dominant factor determining the fluorescence intensity for the short incubation time, whereas the volumetric rate of the circulating flow through the space between films and the specific surface area were the dominant factors for the long incubation time.

19.
Chemphyschem ; 18(17): 2357-2363, 2017 Sep 06.
Article de Anglais | MEDLINE | ID: mdl-28656651

RÉSUMÉ

A four-aperture microchemical pen was used to produce a stable convection-diffusion layer in an "open space" for microreactions and microfabrication. The process represents a new method for microreactions and microfabrication in a convection-diffusion layer. To prove the concept of a convection-diffusion layer in an "open space", bovine serum albumin was labeled with 4-fluoro-7-nitro-2,1,3-benzoxadiazole to confirm that the small convection-diffusion layer was effective for local surface treatment. To demonstrate the potential for microfabrication, silver patterns were fabricated on a glass surface with a convection-diffusion layer by using the silver-mirror reaction. The widths of each silver pattern could be easily controlled from 10 to 60 µm. Patterned silver lines with uniform widths or gradient widths were prepared. This is the first proof of concept study of a convection-diffusion layer in an "open space" used in local surface treatment and microfabrication on a surface. The microchemical pen represents a potential method for the region-selective microtreatment of tissues, cells, and other biological interfaces.


Sujet(s)
Diffusion , Oxadiazoles/composition chimique , Sérumalbumine bovine/composition chimique , Argent/composition chimique , Animaux , Bovins , Verre/composition chimique , Propriétés de surface
20.
J Chromatogr A ; 1477: 127-131, 2016 Dec 16.
Article de Anglais | MEDLINE | ID: mdl-27908497

RÉSUMÉ

The paper describes a new online quantitative electrophoretically mediated microanalysis (EMMA) for use in immunoassays based on the unique drop-by-drop introduction of a sample by means of an inkjet for capillary electrophoresis (CE). Plugs of a fluorescein-labeled antibody (Anti-humanIgG-DyL550) and human IgG were alternately injected into a capillary using the inkjet, followed by the merging of the plugs and the subsequent immune reaction. The antigen-antibody complex that was formed in the merged zone was then separated by CE. As a proof-of-concept, the method was used to determine human IgG. As a result, both the consumption of the reaction solution and the analysis time were significantly reduced. The method showed a wide linear range (10-2000ngmL-1, R2=0.9912) of calibration and the detection limit (5ngmL-1) was substantially lower than that by for conventional methods.


Sujet(s)
Électrophorèse capillaire/méthodes , Électrophorèse sur puce/méthodes , Dosage immunologique/méthodes , Systèmes en direct , Calibrage , Humains , Immunoglobuline G/analyse , Limite de détection , Facteurs temps
SÉLECTION CITATIONS