1.
Rev Sci Instrum ; 87(6): 061301, 2016 Jun.
Article de Anglais | MEDLINE | ID: mdl-27370418

RÉSUMÉ

A precise instrument, called a watt balance, compares mechanical power measured in terms of the meter, the second, and the kilogram to electrical power measured in terms of the volt and the ohm. A direct link between mechanical action and the Planck constant is established by the practical realization of the electrical units derived from the Josephson and the quantum Hall effects. We describe in this paper the fourth-generation watt balance at the National Institute of Standards and Technology (NIST), and report our initial determination of the Planck constant obtained from data taken in late 2015 and the beginning of 2016. A comprehensive analysis of the data and the associated uncertainties led to the SI value of the Planck constant, h = 6.626 069 83(22) × 10(-34) J s. The relative standard uncertainty associated with this result is 34 × 10(-9).

2.
Metrologia ; 53(5)2016.
Article de Anglais | MEDLINE | ID: mdl-32165768

RÉSUMÉ

Using a watt balance and a frequency comb, a mass-energy equivalence is derived. The watt balance compares mechanical power measured in terms of the meter, the second, and the kilogram to electrical power measured in terms of the volt and the ohm. A direct link between mechanical action and the Planck constant is established by the practical realization of the electrical units derived from the Josephson and the quantum Hall effects. By using frequency combs to measure velocities and acceleration of gravity, the unit of mass can be realized from a set of three defining constants: the Planck constant h, the speed of light c, and the hyperfine splitting frequency of 133Cs.

3.
J Res Natl Inst Stand Technol ; 106(4): 627-40, 2001.
Article de Anglais | MEDLINE | ID: mdl-27500039

RÉSUMÉ

The NIST watt balance experiment is being completely rebuilt after its 1998 determination of the Planck constant. That measurement yielded a result with an approximately 1×10(-7) relative standard uncertainty. Because the goal of the new incarnation of the experiment is a ten-fold decrease in uncertainty, it has been necessary to reexamine many sources of systematic error. Hysteresis effects account for a substantial portion of the projected uncertainty budget. They arise from mechanical, magnetic, and thermal sources. The new experiment incorporates several improvements in the apparatus to address these issues, including stiffer components for transferring the mass standard on and off the balance, better servo control of the balance, better pivot materials, and the incorporation of erasing techniques into the mass transfer servo system. We have carried out a series of tests of hysteresis sources on a separate system, and apply their results to the watt apparatus. The studies presented here suggest that our improvements can be expected to reduce hysteresis signals by at least a factor of 10-perhaps as much as a factor of 50-over the 1998 experiment.