Your browser doesn't support javascript.
loading
Montrer: 20 | 50 | 100
Résultats 1 - 4 de 4
Filtrer
Plus de filtres











Base de données
Gamme d'année
1.
Interv Neuroradiol ; : 15910199231201544, 2023 Sep 11.
Article de Anglais | MEDLINE | ID: mdl-37697720

RÉSUMÉ

PURPOSE: This study is a systematic review about the WEB device and addresses the efficacy and safety of this device for the endovascular treatment of ruptured and unruptured intracranial aneurysms. MATERIAL AND METHODS: This systematic literature review followed PRISMA-P guidelines and included studies published until 2010. PubMed and ScienceDirect databases were searched, resulting in 22 articles meeting the inclusion criteria. RESULTS: The studies involved 1705 patients and 1224 aneurysms, predominantly wide-neck aneurysms in the middle cerebral artery, internal carotid artery, and basilar artery. The treatment success rate was 28.1%, with the WEB-SL and WEB-SLS devices being commonly used. The immediate post-treatment adequate occlusion rate was 33.3%, increasing to 49.7% at follow-up. Thromboembolic complications occurred in 6.5% of cases, while other complications were observed in 3.1% of cases. The mortality rate associated with the WEB device was low, approximately 1%. CONCLUSION: The WEB device demonstrates favorable outcomes in treating patients with intracranial aneurysms, with adequate occlusion rates improving over time. Thromboembolic complications are the primary concern, but overall complication and mortality rates remain low. Further research is needed to optimize device selection, standardize classification systems, and enhance long-term evaluation and training protocols.

2.
Interv Neuroradiol ; : 15910199231152514, 2023 Feb 03.
Article de Anglais | MEDLINE | ID: mdl-36734097

RÉSUMÉ

INTRODUCTION: The Woven EndoBridge device (WEB) was developed as an alternative to treat Wide-Necked bifurcation aneurysms. It has proven to be effective and safe, however, cases of recanalization have been reported. The purpose of this study was to evaluate and quantify hemodynamic parameters and indexes with CFD of the intracranial aneurysms before and after WEB simulation and to establish their relationship to complete occlusion. MATERIALS AND METHODS: Using the heterogeneous model based on the marching cubes algorithm, we created 3D representations of 27 bifurcated intracranial aneurysms treated with the single-layer WEB device to evaluate hemodynamics parameters with CFD, calculated with and without the WEB. RESULTS: We observed a lower treatment entry concentration indices (ICI) (2.12 ± 1.31 versus 3.14 ± 0.93, p-value: 0.029) previous to placement of WEB and higher pre-treatment FN (7.56 ± 5.92 versus 3.35 ± 1.51, p-value: 0.018) and post-treatment FN (5.34 ± 5.89 versus 1.99 ± 0.83, p-value: 0.021) for cases with successful occlusions. Lower post-treatment SRa (197.81 ± 221.29 versus 80.02 ± 45.25, p-value: 0.044) and higher pre (0.11 ± 0.07 versus 0.25 ± 0.19, p-value: 0.011) and post-treatment MATT (0.69 ± 1.23 versus 1.02 ± 0.46, p-value: 0.006) were observed in non-occluded cases. CONCLUSIONS: In our CFD analysis of the hemodynamic parameters of IA, we found lower ICI before the placement of the WEB device and higher FN pre- and post-treatment for cases with successful occlusions. Non-occluded cases had lower post-treatment SRa and higher pre-treatment and post-treatment MATT.

3.
Interv Neuroradiol ; : 15910199231152504, 2023 Jan 26.
Article de Anglais | MEDLINE | ID: mdl-36703556

RÉSUMÉ

INTRODUCTION: The Woven EndoBridge device (WEB) is used to treat wide-neck bifurcation aneurysms. These devices are deployed inside the sac. Therefore, the mesh structure provides apposition with the aneurysm wall and induces aneurysmal thrombosis. The objective of our study was to evaluate the anatomic and device-related parameters and indexes with Computational Fluid Dynamics (CFD) of the intracranial aneurysms before and after WEB simulation and find their relationship to complete occlusion. MATERIALS AND METHODS: Using the heterogeneous model based on the marching cubes algorithm, we created 3D representations of 27 bifurcated intracranial aneurysms treated with the single-layer WEB device to evaluate anatomic and device-related parameters with CFD. RESULTS: In our CFD analysis, we observed higher large volumes (Va) (0.25 ± 0.18 versus 0.39 ± 0.09, p-value= 0.025) and higher volume to neck surface ratio (Ra) (1.32 ± 0.17 versus 1.54 ± 0.14, p-value= 0.021) in cases with occlusion failure. CONCLUSIONS: Large aneurysm volumes (Va) and higher volume to neck surface ratio (Ra) could be associated with occlusion failure in aneurysms treated with the WEB device.

4.
Interv Neuroradiol ; : 15910199221143254, 2022 Dec 12.
Article de Anglais | MEDLINE | ID: mdl-36503318

RÉSUMÉ

INTRODUCTION: Three-dimensional (3D) printing has evolved for medical applications as it can produce customized 3D models of devices and implants that can improve patient care. In this study, we aimed to validate the geometrical accuracy of the 3D models of intracranial aneurysms printed using Stereolithography 3D printing technology. MATERIALS AND METHODS: To compare the unruptured intracranial aneurysm mesh between the five patients and 3D printed models, we opened the DICOM files in the Sim&Size® simulation software, selected the region of interest, and performed the threshold check. We juxtaposed the 3D reconstructions and manually rotated the images to get the same orientation when needed and measured deviations at different nodes of the patient and 3D printed model meshes. RESULTS: In the first patient, 80% of the nodes were separated by <0.56 mm and 0.17 mm. In the second patient, the deviations were below 0.17 mm for 80% of the meshes' nodes. In the next three patients, the deviations were below 0.21, 0.23, and 0.11 mm for 80% of the meshes' nodes. Finally, the overall deviation was below 0.21 mm for 80% of the mesh nodes of the five aneurysms. CONCLUSIONS: 3D printed models of intracranial aneurysms are accurate, having surfaces that resemble that of patients' angiographies with an 80% cumulative deviation below 0.21 mm.

SÉLECTION CITATIONS
DÉTAIL DE RECHERCHE