Your browser doesn't support javascript.
loading
Montrer: 20 | 50 | 100
Résultats 1 - 20 de 32
Filtrer
1.
Int J Numer Method Biomed Eng ; 40(6): e3822, 2024 Jun.
Article de Anglais | MEDLINE | ID: mdl-38566253

RÉSUMÉ

We examined the effect of minimal lumen segmentation uncertainty on Fractional Flow Reserve obtained from Coronary Computed Tomography Angiography FFR CT . A total of 14 patient-specific coronary models with different stenosis locations and degrees of severity were enrolled in this study. The optimal segmented coronary lumens were disturbed using intra ± 6 % and inter-operator ± 15 % variations on the segmentation threshold. FFR CT was evaluated in each case by 3D-OD CFD simulations. The findings suggest that the sensitivity of FFR CT to this type of uncertainty increases distally and with the stenosis severity. Cases with moderate or severe distal coronary lesions should undergo either exact and thorough segmentation operations or invasive FFR measurements, particularly if the FFR CT is close to the cutoff (0.80). Therefore, we conclude that it is crucial to consider the lesion's location and degree of severity when evaluating FFR CT results.


Sujet(s)
Vaisseaux coronaires , Fraction du flux de réserve coronaire , Humains , Fraction du flux de réserve coronaire/physiologie , Vaisseaux coronaires/imagerie diagnostique , Vaisseaux coronaires/physiopathologie , Modèles cardiovasculaires , Angiographie par tomodensitométrie , Coronarographie , Mâle , Incertitude , Femelle , Adulte d'âge moyen , Simulation numérique , Sténose coronarienne/physiopathologie , Sténose coronarienne/imagerie diagnostique , Sujet âgé , Tomodensitométrie
2.
J Clin Med ; 10(17)2021 Sep 04.
Article de Anglais | MEDLINE | ID: mdl-34501454

RÉSUMÉ

BACKGROUND: Both balloon-expandable (BE) and self-expandable (SE) valves for transcatheter aortic valve implantation (TAVI) are broadly used in clinical practice. However, adequately powered randomized controlled trials comparing these two valve designs are lacking. METHODS: The CENTER-study included 12,381 patients undergoing transfemoral TAVI. Patients undergoing TAVI with a BE-valve (n = 4096) were compared to patients undergoing TAVI with an SE-valve (n = 4096) after propensity score matching. Clinical outcomes including one-year mortality and stroke rates were assessed. RESULTS: In the matched population of n = 5410 patients, the mean age was 81 ± 3 years, 60% was female, and the STS-PROM predicted 30-day mortality was 6.2% (IQR 4.0-12.4). One-year mortality was not different between patients treated with BE- or SE-valves (BE: 16.4% vs. SE: 17.0%, Relative Risk 1.04, 95%CI 0.02-1.21, p = 0.57). One-year stroke rates were also comparable (BE: 4.9% vs. SE: 5.3%, RR 1.09, 95%CI 0.86-1.37, p = 0.48). CONCLUSION: This study suggests that one-year mortality and stroke rates were comparable in patients with severe aortic valve stenosis undergoing TAVI with either BE or SE-valves.

4.
J Clin Med ; 9(7)2020 Jul 19.
Article de Anglais | MEDLINE | ID: mdl-32707736

RÉSUMÉ

INTRODUCTION AND OBJECTIVE: Major bleeding events in patients undergoing left atrial appendage closure (LAAC) range from 2.2 to 10.3 per 100 patient-years in different series. This study aimed to clarify the bleeding predictive factors that could influence these differences. METHODS: LAAC was performed in 598 patients from the Iberian Registry II (1093 patient-years; median, 75.4 years). We conducted a multivariate analysis to identify predictive risk factors for major bleeding events. The occurrence of thromboembolic and bleeding events was compared to rates expected from CHA2DS2-VASc (congestive heart failure, hypertension, age, diabetes, stroke history, vascular disease, sex) and HAS-BLED (hypertension, abnormal renal and liver function, stroke, bleeding, labile INR, elderly, drugs or alcohol) scores. RESULTS: Cox regression analysis revealed that age ≥75 years (HR: 2.5; 95% CI: 1.3 to 4.8; p = 0.004) and a history of gastrointestinal bleeding (GIB) (HR: 2.1; 95% CI: 1.1 to 3.9; p = 0.020) were two factors independently associated with major bleeding during follow-up. Patients aged <75 or ≥75 years had median CHA2DS2-VASc scores of 4 (IQR: 2) and 5 (IQR: 2), respectively (p < 0.001) and HAS-BLED scores were 3 (IQR: 1) and 3 (IQR: 1) for each group (p = 0.007). Events presented as follow-up adjusted rates according to age groups were stroke (1.2% vs. 2.9%; HR: 2.4, p = 0.12) and major bleeding (3.7 vs. 9.0 per 100 patient-years; HR: 2.4, p = 0.002). Expected major bleedings according to HAS-BLED scores were 6.2% vs. 6.6%, respectively. In patients with GIB history, major bleeding events were 6.1% patient-years (HAS-BLED score was 3.8 ± 1.1) compared to 2.7% patients-year in patients with no previous GIB history (HAS-BLED score was 3.4 ± 1.2; p = 0.029). CONCLUSIONS: In this high-risk population, GIB history and age ≥75 years are the main predictors of major bleeding events after LAAC, especially during the first year. Age seems to have a greater influence on major bleeding events than on thromboembolic risk in these patients.

9.
Enferm. infecc. microbiol. clín. (Ed. impr.) ; 37(7): 428-434, ago.-sept. 2019. tab, graf
Article de Espagnol | IBECS | ID: ibc-189358

RÉSUMÉ

INTRODUCCIÓN: La endocarditis infecciosa (EI) sobre transcatheter aortic valve implantation (TAVI) es una complicación emergente. Existen datos incompletos y dispares sobre su incidencia. Se aporta la experiencia en nuestro centro sobre incidencia, mortalidad y factores asociados de la EI post-TAVI y se compara con datos de la literatura. MÉTODOS: Estudio retrospectivo observacional de los casos de EI diagnosticados en pacientes que habían recibido TAVI, entre el 1 de junio de 2009 y el 1 de noviembre de 2017, en un centro universitario tras una mediana de seguimiento de 15,3 meses (rango intercuartil [RIC] 9,1-36,2). Se analizaron la incidencia, los datos clínicos, microbiológicos y pronósticos, y los factores asociados a EI post-TAVI. RESULTADOS: Se detectaron 11 pacientes con EI de 200 TAVI. Incidencia global: 5,5% (2,77 casos por 100 años-paciente). La mediana de tiempo hasta la EI post-TAVI fue de 112 días (RIC 36-578), la tasa de mortalidad intrahospitalaria fue del 36,4% y la mortalidad al año, del 54,5%. Todos los microorganismos identificados fueron grampositivos (4 Enterococcus faecalis, 3 Staphylococcus coagulasa negativo). Los pacientes con EI post-TAVI eran significativamente más jóvenes (mediana 78, RIC 73-80, frente a 82, RIC 79-84, p = 0,002), tenían un EuroSCORE mayor (5,1 ± 2,4 frente a 3,2 ± 1,2, p < 0,001) y más frecuentemente antecedentes de neoplasia (18,2% frente al 4,2%, p < 0,03). CONCLUSIONES: En nuestro medio, la incidencia de EI post-TAVI es mayor que la descrita en series multicéntricas, lo que concuerda con la tendencia publicada en la literatura. Conlleva una elevada mortalidad y se asocia con una peor situación clínica basal


INTRODUCTION: Infective endocarditis (IE) after transcatheter aortic valve implantation (TAVI) is an emerging complication. There are incomplete and disparate data on its incidence. We present the experience of a single-centre of incidence, mortality and associated factors of IE after TAVI. METHODS: A retrospective observational study of IE cases in people who received a TAVI, between 06/01/2009 and 11/01/2017, in a university hospital, during a median follow-up period of 15.3months (interquartile range [IQR] 9.1-36.2). Incidence, clinical, microbiological and prognostic data, and factors associated with IE after TAVI were analysed. RESULTS: Eleven patients with IE of 200 TAVI were detected. Global incidence: 5.5% (2.77 cases per 100 patient-year). The median of days from TAVI to IE was 112 (IQR 36-578), the in-hospital mortality rate was 36.4%, and the one-year mortality rate was 54.5%. All the organisms identified were gram-positive (4 Enterococcus faecalis, 3 coagulase-negative Staphylococcus). The patients with IE after TAVI were significantly younger (median 78 years, IQR 73-80, versus 82 years, IQR 79-84, P=.002), they had a higher EuroSCORE (5.1±2.4 versus 3.2 ± 1.2, P < .001), and they more frequently had a history of neoplasia (18.2% versus 4.2%, P < .03). CONCLUSIONS: In our area, IE after TAVI has an incidence greater than that described in multicentre series, this is in line with the trend published in the literature. It leads to high mortality and is associated with a worse baseline clinical situation


Sujet(s)
Humains , Mâle , Femelle , Adulte d'âge moyen , Sujet âgé , Sujet âgé de 80 ans ou plus , Endocardite bactérienne/microbiologie , Remplacement valvulaire aortique par cathéter/effets indésirables , Endocardite bactérienne/épidémiologie , Facteurs de risque , Études rétrospectives , Mortalité hospitalière , Antibioprophylaxie/méthodes , Tests de sensibilité microbienne , Endocardite bactérienne/étiologie
10.
Article de Anglais, Espagnol | MEDLINE | ID: mdl-30389267

RÉSUMÉ

INTRODUCTION: Infective endocarditis (IE) after transcatheter aortic valve implantation (TAVI) is an emerging complication. There are incomplete and disparate data on its incidence. We present the experience of a single-centre of incidence, mortality and associated factors of IE after TAVI. METHODS: A retrospective observational study of IE cases in people who received a TAVI, between 06/01/2009 and 11/01/2017, in a university hospital, during a median follow-up period of 15.3months (interquartile range [IQR] 9.1-36.2). Incidence, clinical, microbiological and prognostic data, and factors associated with IE after TAVI were analysed. RESULTS: Eleven patients with IE of 200 TAVI were detected. Global incidence: 5.5% (2.77 cases per 100 patient-year). The median of days from TAVI to IE was 112 (IQR 36-578), the in-hospital mortality rate was 36.4%, and the one-year mortality rate was 54.5%. All the organisms identified were gram-positive (4 Enterococcus faecalis, 3 coagulase-negative Staphylococcus). The patients with IE after TAVI were significantly younger (median 78years, IQR 73-80, versus 82 years, IQR 79-84, P=.002), they had a higher EuroSCORE (5.1±2.4 versus 3.2±1.2, P<.001), and they more frequently had a history of neoplasia (18.2% versus 4.2%, P<.03) CONCLUSIONS: In our area, IE after TAVI has an incidence greater than that described in multicentre series, this is in line with the trend published in the literature. It leads to high mortality and is associated with a worse baseline clinical situation.


Sujet(s)
Infection croisée/étiologie , Endocardite bactérienne/étiologie , Infections bactériennes à Gram positif/étiologie , Infection de plaie opératoire/étiologie , Remplacement valvulaire aortique par cathéter/effets indésirables , Sujet âgé , Sujet âgé de 80 ans ou plus , Antibioprophylaxie , Sténose aortique/chirurgie , Infection croisée/épidémiologie , Infection croisée/microbiologie , Endocardite bactérienne/épidémiologie , Endocardite bactérienne/microbiologie , Enterococcus , Enterococcus faecalis/isolement et purification , Femelle , Études de suivi , Infections bactériennes à Gram positif/épidémiologie , Infections bactériennes à Gram positif/microbiologie , Hôpitaux universitaires , Humains , Incidence , Estimation de Kaplan-Meier , Mâle , Adulte d'âge moyen , Études rétrospectives , Facteurs de risque , Staphylococcus aureus/isolement et purification , Staphylococcus epidermidis , Infection de plaie opératoire/épidémiologie , Infection de plaie opératoire/microbiologie
16.
Cardiovasc Revasc Med ; 18(6 Suppl 1): 17-18, 2017 09.
Article de Anglais | MEDLINE | ID: mdl-28302465

RÉSUMÉ

We present a case of a 52 year old female who suffered from a sudden syncope. A coronariography was performed and spontaneous coronary dissection was diagnosed in the posterior descending artery after an optical coherence tomography (OCT) was performed. A conservative management was decided. During hospitalization the patient presented with an episode of chest pain with an anterior ST elevation on ECG. Coronariography showed total occlusion of the left descending artery and again a dissection was diagnosed by OCT. This time, 2 stents were implanted in the affected artery. The hypothesis that the coronary adventitial volume of vasa vasorum is higher in patients with spontaneous coronary artery dissection has been demonstrated in a recent small study and it was observed in this patient. Conservative management is preferred in most cases, proceeding to revascularization for patients with ongoing chest pain, hemodynamic instability and ST elevation, mostly if it affects major arteries.


Sujet(s)
Anomalies congénitales des vaisseaux coronaires/complications , Vaisseaux coronaires/chirurgie , Intervention coronarienne percutanée/méthodes , Infarctus du myocarde avec sus-décalage du segment ST/étiologie , Maladies vasculaires/congénital , Coronarographie , Anomalies congénitales des vaisseaux coronaires/diagnostic , Anomalies congénitales des vaisseaux coronaires/chirurgie , Vaisseaux coronaires/imagerie diagnostique , Femelle , Humains , Adulte d'âge moyen , Récidive , Infarctus du myocarde avec sus-décalage du segment ST/diagnostic , Infarctus du myocarde avec sus-décalage du segment ST/chirurgie , Tomographie par cohérence optique , Maladies vasculaires/complications , Maladies vasculaires/diagnostic , Maladies vasculaires/chirurgie
17.
Rev Port Cardiol ; 35(4): 239.e1-5, 2016 Apr.
Article de Anglais | MEDLINE | ID: mdl-27004431

RÉSUMÉ

Transcatheter aortic valve replacement (TAVR) is an increasingly common procedure for the treatment of aortic stenosis in elderly patients with comorbidities that prevent the use of standard surgery. It has been shown that implantation without aortic regurgitation is related to lower mortality. Mild paravalvular regurgitation is inevitable in some cases due to calcification of the aortic annulus and its usually somewhat elliptical shape. Central regurgitation is less common, but has been associated with valve overdilatation in cases in which reduction of paravalvular regurgitation was attempted after the initial inflation. However, there are no reported cases of central prosthetic aortic regurgitation due to acute LV dysfunction. We report a case in which central aortic regurgitation occurred due to transient ventricular dysfunction secondary to occlusion of the right coronary artery by an embolus. The regurgitation disappeared after thrombus aspiration and normal ventricular function was immediately recovered.


Sujet(s)
Insuffisance aortique/étiologie , Implantation de valve prothétique cardiaque/effets indésirables , Valve aortique , Sténose aortique , Embolie , Humains
SÉLECTION CITATIONS
DÉTAIL DE RECHERCHE