Your browser doesn't support javascript.
loading
Montrer: 20 | 50 | 100
Résultats 1 - 20 de 35
Filtrer
1.
J Nucl Med ; 2024 Jul 25.
Article de Anglais | MEDLINE | ID: mdl-39054282

RÉSUMÉ

The epidermal growth factor receptor (EGFR) protein is highly expressed in a range of malignancies. Although therapeutic interventions directed toward EGFR have yielded therapeutic responses in cancer patients, side effects are common because of normal-tissue expression of wild-type EGFR. We developed a novel tumor-specific anti-EGFR chimeric antibody ch806 labeled with 225Ac and evaluated its in vitro properties and therapeutic efficacy in murine models of glioblastoma and colorectal cancer. Methods: 225Ac-ch806 was prepared using different chelators, yielding [225Ac]Ac-macropa-tzPEG3Sq-ch806 and [225Ac]Ac-DOTA-dhPzPEG4-ch806. Radiochemical yield, purity, apparent specific activity, and serum stability of 225Ac-ch806 were quantified. In vitro cell killing effect was examined. The biodistribution and therapeutic efficacy of 225Ac-ch806 were investigated in mice with U87MG.de2-7 and DiFi tumors. Pharmacodynamic analysis of tumors after therapy was performed, including DNA double-strand break immunofluorescence of γH2AX, as well as immunohistochemistry for proliferation, cell cycle arrest, and apoptosis. Results: [225Ac]Ac-macropa-tzPEG3Sq-ch806 surpassed [225Ac]Ac-DOTA-dhPzPEG4-ch806 in radiochemical yield, purity, apparent specific activity, and serum stability. [225Ac]Ac-macropa-tzPEG3Sq-ch806 was therefore used for both in vitro and in vivo studies. It displayed a significant, specific, and dose-dependent in vitro cell-killing effect in U87MG.de2-7 cells. 225Ac-ch806 also displayed high tumor uptake and minimal uptake in normal tissues. 225Ac-ch806 significantly inhibited tumor growth and prolonged survival in both U87MG.de2-7 and DiFi models. Enhanced γH2AX staining was observed in 225Ac-ch806-treated tumors compared with controls. Reduced Ki-67 expression was evident in all 225Ac-ch806-treated tumors. Increased expression of p21 and cleaved caspase 3 was shown in U87MG.de2-7 and DiFi tumors treated with 225Ac-ch806. Conclusion: In glioblastoma and colorectal tumor models, 225Ac-ch806 significantly inhibited tumor growth via induction of double-strand breaks, thereby constraining cancer cell proliferation while inducing cell cycle arrest and apoptosis. These findings underscore the potential clinical applicability of 225Ac-ch806 as a potential therapy for EGFR-expressing solid tumors.

2.
Invest New Drugs ; 40(4): 747-755, 2022 08.
Article de Anglais | MEDLINE | ID: mdl-35404015

RÉSUMÉ

Ephrin type-A 2 (EphA2) is a transmembrane receptor expressed in epithelial cancers. We report on a phase I dose escalation and biodistribution study of DS-8895a, an anti-EphA2 antibody, in patients with advanced EphA2 positive cancers. DS-8895a was administered at 1, 3, 10 or 20 mg/kg every 2 weeks to determine safety, pharmacokinetics and anti-tumor efficacy. All patients underwent 89Zr trace-labelled infusion of DS-8895a (89Zr-DS-8995a) positron emission tomography imaging to determine the biodistribution of DS-8895a, and correlate findings with EphA2 expression, receptor saturation and response. Nine patients were enrolled on study. Of patients enrolled, seven patients received at least one infusion of DS-8895a: four patients received 1 mg/kg dose (Cohort 1) and three patients received 3 mg/kg dose (Cohort 2). Median age was 67.0 years (range 52-81), majority male (71%), and median number of prior systemic therapies was three (range 0-8). The primary cancer diagnosis was colorectal cancer (two patients) and one patient each had gastric, head and neck, high-grade serous adenocarcinoma, lung, and pancreatic cancers. No dose-limiting toxicities or treatment-related adverse events reported. The best response for the patients in Cohort 1 was stable disease and in Cohort 2 was progressive disease. 89Zr-DS-8895a demonstrated no normal tissue uptake and specific low-grade uptake in most tumours. DS-8895a had limited therapeutic efficacy at doses evaluated and 89Zr-DS-8895a demonstrated low tumour uptake. The biodistribution data from this study were key in halting further development of DS-8895a, highlighting the importance of biodistribution studies in drug development. (Trial registration: ClinicalTrials.gov Identifier NCT02252211).


Sujet(s)
Anticorps monoclonaux humanisés , Antinéoplasiques immunologiques , Tumeurs , Sujet âgé , Sujet âgé de 80 ans ou plus , Anticorps monoclonaux , Anticorps monoclonaux humanisés/pharmacocinétique , Anticorps monoclonaux humanisés/usage thérapeutique , Antinéoplasiques , Antinéoplasiques immunologiques/pharmacocinétique , Antinéoplasiques immunologiques/usage thérapeutique , Éphrine A2/immunologie , Humains , Mâle , Adulte d'âge moyen , Tumeurs/imagerie diagnostique , Tumeurs/traitement médicamenteux , Récepteur EphA2/effets des médicaments et des substances chimiques , Distribution tissulaire
3.
Neurooncol Adv ; 3(1): vdab102, 2021.
Article de Anglais | MEDLINE | ID: mdl-34549181

RÉSUMÉ

BACKGROUND: The adverse impact of increasing brain tumor size on the efficacy of antibody-drug conjugates (ADCs) was investigated preclinically then validated with clinical data. METHODS­PRECLINICAL STUDY: The impact of tumor size on ADC tumor delivery and treatment response was evaluated in an EGFR-amplified patient-derived glioblastoma (GBM) model following treatment with Depatuxizumab mafadotin (Depatux-M). Biodistribution and imaging studies correlated drug distribution with starting treatment volume and anti-tumor activity. METHODS­CLINICAL STUDY: M12-356 was a Phase I study of Depatux-M in patients with GBM. Blinded volumetric analysis of baseline tumor volumes of M12-356 patients was undertaken by two reviewers and results correlated with response and survival. RESULTS: Preclinically, imaging and biodistribution studies showed specific and significantly higher tumor uptake of zirconium-89 labeled Depatux-M (89Zr-Depatux-M) in mice with smaller tumor volume (~98 mm3) versus those with larger volumes (~365 mm3); concordantly, mice with tumor volumes ≤100 mm3 at treatment commencement had significantly better growth inhibition by Depatux-M (93% vs 27%, P < .001) and significantly longer overall survival (P < .0001) compared to tumors ≥400 mm3. Clinically, patients with tumor volumes <25 cm3 had significantly higher response rates (17% vs. 0%, P = .009) and longer overall survival (0.5 vs 0.89 years, P = .001) than tumors above 25 cm3. CONCLUSION: Both preclinical and clinical data showed intra-tumoral concentration and efficacy of Depatux-m inversely correlated with tumor size. This finding merit further investigation with pretreatment tumor volume as a predictor for response to ADCs, in both gliomas and other solid tumors.

4.
EBioMedicine ; 65: 103252, 2021 Mar.
Article de Anglais | MEDLINE | ID: mdl-33640794

RÉSUMÉ

BACKGROUND: A research priority in finding a cure for HIV is to establish methods to accurately locate and quantify where and how HIV persists in people living with HIV (PLWH) receiving suppressive antiretroviral therapy (ART). Infusing copper-64 (64Cu) radiolabelled broadly neutralising antibodies targeting HIV envelope (Env) with CT scan and positron emission tomography (PET) identified HIV Env in tissues in SIV infected non-human primates . We aimed to determine if a similar approach was effective in people living with HIV (PLWH). METHODS: Unmodified 3BNC117 was compared with 3BNC117 bound to the chelator MeCOSar and 64Cu (64Cu-3BNC117) in vitro to assess binding and neutralization. In a clinical trial 64Cu-3BNC117 was infused into HIV uninfected (Group 1), HIV infected and viremic (viral load, VL >1000 c/mL; Group 2) and HIV infected aviremic (VL <20 c/mL; Group 3) participants using two dosing strategies: high protein (3mg/kg unlabeled 3BNC117 combined with <5mg 64Cu-3BNC117) and trace (<5mg 64Cu-3BNC117 only). All participants were screened for 3BNC117 sensitivity from virus obtained from viral outgrowth. Magnetic resonance imaging (MRI)/PET and pharmacokinetic assessments (ELISA for serum 3BNC117 concentrations and gamma counting for 64Cu) were performed 1, 24- and 48-hours post dosing. The trial (clincialtrials.gov NCT03063788) primary endpoint was comparison of PET standard uptake values (SUVs) in regions of interest (e.g lymph node groups and gastrointestinal tract). FINDINGS: Comparison of unmodified and modified 3BNC117 in vitro demonstrated no difference in HIV binding or neutralisation. 17 individuals were enrolled of which 12 were dosed including Group 1 (n=4, 2 high protein, 2 trace dose), Group 2 (n=6, 2 high protein, 4 trace) and Group 3 (n=2, trace only). HIV+ participants had a mean CD4 of 574 cells/microL and mean age 43 years. There were no drug related adverse effects and no differences in tissue uptake in regions of interest (e.g lymph node gut, pharynx) between the 3 groups. In the high protein dosing group, serum concentrations of 3BNC117 and gamma counts were highly correlated demonstrating that 64Cu-3BNC117 remained intact in vivo. INTERPRETATION: In PLWH on or off ART, the intervention of infusing 64Cu-3BNC117 and MRI/PET imaging over 48 hours, was unable to detect HIV-1 env expression in vivo. Future studies should investigate alternative radiolabels such as zirconium which have a longer half-life in vivo. FUNDING: Funded by the Alfred Foundation, The Australian Centre for HIV and Hepatitis Virology Research with additional support from the Division of AIDS, National Institute of Allergy and Infectious Disease, US National Institutes of Health (USAI126611). JHM and SRL are supported by the Australian National Health and Medical Research Council.


Sujet(s)
Anticorps monoclonaux/composition chimique , Anticorps anti-VIH/composition chimique , Infections à VIH/imagerie diagnostique , VIH-1 (Virus de l'Immunodéficience Humaine de type 1)/immunologie , Radiopharmaceutiques/administration et posologie , Adulte , Antirétroviraux/usage thérapeutique , Anticorps monoclonaux/immunologie , Lymphocytes T CD4+/cytologie , Lymphocytes T CD4+/métabolisme , Lymphocytes T CD4+/virologie , Études cas-témoins , Radio-isotopes du cuivre/composition chimique , Femelle , Anticorps anti-VIH/immunologie , Protéine d'enveloppe gp120 du VIH/immunologie , Infections à VIH/traitement médicamenteux , Infections à VIH/virologie , VIH-1 (Virus de l'Immunodéficience Humaine de type 1)/isolement et purification , VIH-1 (Virus de l'Immunodéficience Humaine de type 1)/métabolisme , Période , Humains , Marquage isotopique , Mâle , Adulte d'âge moyen , Tomographie par émission de positons , Radiopharmaceutiques/composition chimique , Radiopharmaceutiques/immunologie , Radiopharmaceutiques/pharmacocinétique , Tomodensitométrie
5.
J Clin Endocrinol Metab ; 106(1): e61-e73, 2021 01 01.
Article de Anglais | MEDLINE | ID: mdl-33090207

RÉSUMÉ

AIMS: To evaluate diagnostic performance of glomerular filtration rate (GFR) estimated by modification of diet in renal disease (MDRD), chronic kidney disease epidemiology collaboration (CKD-EPI), full age spectrum (FAS), and revised Lund-Malmö (r-LM) equations in adults with diabetes. METHODS: Individuals were included in this cross-sectional study if they had at least 1 measurement of technetium-99m diethylenetriamine-pentaacetic acid (99mTc-DTPA) GFR (mGFR) and serum creatinine (1487 patients with 2703 measures). GFR calculated by estimation equations was compared with mGFR. Diagnostic performance was assessed using concordance correlation coefficient (CCC), bias, precision, accuracy, reduced major axis regression (RMAR), and Bland-Altman plot. Analysis was repeated in subgroups based on sex, diabetes type, Hemoglobin A1C, and GFR level. RESULTS: Of all patients, 1189 (86%) had type 2 diabetes. Mean mGFR, MDRD, CKD-EPI, FAS, and revised Lund-Malmö eGFR were 66, 72, 74, 71, and 67 mL/min/1.73m2, respectively. Overall, the r-LM had the highest CCC (0.83), lowest bias (-1.4 mL/min/1.73 m2), highest precision (16.2 mL/min/1.73 m2), and highest accuracy (P10 = 39%). The RMAR (slope, intercept) in r-LM, FAS, MDRD, and CKD-EPI was 1.18, -13.35; 0.97, -2.9; 1, -6.4, and 1.04, -11.3, respectively. The Bland-Altman plot showed that r-LM had the lowest mean difference and the narrowest 95% limit of agreement (-1.0, 54.1 mL/min/1.73 m2), while mean difference was more than 5-fold higher in FAS, MDRD, and CKD-EPI (-5.2, -6.3, and -8.2, respectively). CONCLUSIONS: In adults with diabetes the revised Lund-Malmö performs better than MDRD, CKD-EPI, and FAS in calculating point estimates of GFR.


Sujet(s)
Créatinine/sang , Diabète , Néphropathies diabétiques/diagnostic , Débit de filtration glomérulaire , Adulte , Sujet âgé , Algorithmes , Créatinine/analyse , Diabète/sang , Diabète/diagnostic , Diabète/physiopathologie , Diabète/urine , Néphropathies diabétiques/sang , Néphropathies diabétiques/urine , Femelle , Hémoglobine glyquée/analyse , Hémoglobine glyquée/métabolisme , Humains , Mâle , Adulte d'âge moyen , Modèles théoriques , Valeur prédictive des tests , Insuffisance rénale chronique/sang , Insuffisance rénale chronique/diagnostic , Insuffisance rénale chronique/physiopathologie , Insuffisance rénale chronique/urine , Reproductibilité des résultats
6.
Theranostics ; 10(25): 11404-11415, 2020.
Article de Anglais | MEDLINE | ID: mdl-33052222

RÉSUMÉ

Through protein engineering and a novel pegylation strategy, a diabody specific to tumor-associated glycoprotein 72 (TAG-72) (PEG-AVP0458) has been created to optimize pharmacokinetics and bioavailability to tumor. We report the preclinical and clinical translation of PEG-AVP0458 to a first-in-human clinical trial of a diabody. Methods: Clinical translation followed characterization of PEG-AVP0458 drug product and preclinical biodistribution and imaging assessments of Iodine-124 trace labeled PEG-AVP0458 (124I-PEG-AVP0458). The primary study objective of the first-in-human study was the safety of a single protein dose of 1.0 or 10 mg/m2 124I-PEG-AVP0458 in patients with TAG-72 positive relapsed/ metastatic prostate or ovarian cancer. Secondary study objectives were evaluation of the biodistribution, tumor uptake, pharmacokinetics and immunogenicity. Patients were infused with a single-dose of 124I labeled PEG-AVP0458 (3-5 mCi (111-185 MBq) for positron emission tomography (PET) imaging, performed sequentially over a one-week period. Safety, pharmacokinetics, biodistribution, and immunogenicity were assessed up to 28 days after infusion. Results: PEG-AVP0458 was radiolabeled with 124I and shown to retain high TAG-72 affinity and excellent targeting of TAG-72 positive xenografts by biodistribution analysis and PET imaging. In the first-in-human trial, no adverse events or toxicity attributable to 124I-PEG-AVP0458 were observed. Imaging was evaluable in 5 patients, with rapid and highly specific targeting of tumor and minimal normal organ uptake, leading to high tumor:blood ratios. Serum concentration values of 124I-PEG-AVP0458 showed consistent values between patients, and there was no significant difference in T½α and T½ß between dose levels with mean (± SD) results of T½α = 5.10 ± 4.58 hours, T½ß = 46.19 ± 13.06 hours. Conclusions: These data demonstrates the safety and feasibility of using pegylated diabodies for selective tumor imaging and potential delivery of therapeutic payloads in cancer patients.


Sujet(s)
Anticorps bispécifiques/effets indésirables , Antigènes néoplasiques/métabolisme , Antinéoplasiques/effets indésirables , Tumeurs/traitement médicamenteux , Radiopharmaceutiques/effets indésirables , Adulte , Animaux , Anticorps bispécifiques/administration et posologie , Anticorps bispécifiques/génétique , Anticorps bispécifiques/pharmacocinétique , Anticorps antitumoraux/génétique , Antinéoplasiques/administration et posologie , Antinéoplasiques/composition chimique , Antinéoplasiques/pharmacocinétique , Biodisponibilité , Lignée cellulaire tumorale , Relation dose-effet des médicaments , Études de faisabilité , Femelle , Humains , Perfusions veineuses , Radio-isotopes de l'iode/administration et posologie , Radio-isotopes de l'iode/effets indésirables , Radio-isotopes de l'iode/pharmacocinétique , Mâle , Souris , Tumeurs/diagnostic , Tumeurs/immunologie , Tumeurs/anatomopathologie , Tomographie par émission de positons couplée à la tomodensitométrie , Radiopharmaceutiques/administration et posologie , Radiopharmaceutiques/composition chimique , Radiopharmaceutiques/pharmacocinétique , Protéines recombinantes/administration et posologie , Protéines recombinantes/effets indésirables , Protéines recombinantes/génétique , Protéines recombinantes/pharmacocinétique , Anticorps à chaîne unique/administration et posologie , Anticorps à chaîne unique/effets indésirables , Anticorps à chaîne unique/génétique , Anticorps à chaîne unique/pharmacocinétique , Distribution tissulaire , Tests d'activité antitumorale sur modèle de xénogreffe
7.
EJNMMI Res ; 10(1): 61, 2020 Jun 12.
Article de Anglais | MEDLINE | ID: mdl-32533449

RÉSUMÉ

BACKGROUND: 4-[18F] fluorobenzyl dexetimide (F-DEX) is the first non-subtype selective fluorine-18 labelled tracer for muscarinic receptors (mAChR) used in humans. A recent first-in-human study found high regional brain uptake with low variation in normal subjects. Disturbance of mAChR has been reported in Alzheimer's and Parkinson's disease, schizophrenia and depression and various cardiac diseases. The following work assesses the biodistribution, organ tracer kinetics and radiation dose associated with F-DEX. METHOD: Dose calculations were based on activity uptake derived from multiple time point whole body PET CT imaging and the organ-specific dosimetric S-factors derived from the ICRP 133 standard man and woman mathematical phantoms. Effective doses were calculated using the latest ICRP tissue weighting factors. RESULTS: Serial images and time activity curves demonstrate high brain and left ventricular myocardial uptake (5% and 0.65% of injected activity, respectively) with greater retention in brain than myocardium. The mean effective dose was in concordance with other 18F labelled tracers at 19.70 ± 2.27 µSv/MBq. The largest absorbed doses were in the liver (52.91 ± 1.46 µGy/MBq) and heart wall (43.94 ± 12.88 µGy/MBq) for standard man and the liver (61.66 ± 13.61 µGy/MBq) and lungs (40.93 ± 3.11 µGy/MBq) for standard woman. The absorbed dose to all organs, most notably, the red bone marrow (20.03 ± 2.89 µGy/MBq) was sufficiently low to ensure no toxicity after numerous follow-up procedures. CONCLUSIONS: The radiation dose associated with an administration of F-DEX is comparable to that of other 18F labelled tracers such as FDG (19.0 µSv/MBq) and lower than tracers used for SPECT imaging of muscarinic receptors (I-DEX 28.5 µSv/MBq). Clinical use would likely result in an effective dose less than 4 mSv for the ICRP 133 standard phantoms after dose optimisation allowing justification for numerous follow-up procedures. Recent results from first in-human studies and a comparatively low radiation dose make F-DEX an attractive option for future applications of imaging muscarinic receptors in the brain. Further investigation of the potential of F-DEX for imaging parasympathetic innervation of the heart may be warranted.

8.
Eur J Nucl Med Mol Imaging ; 47(6): 1476-1485, 2020 06.
Article de Anglais | MEDLINE | ID: mdl-32025750

RÉSUMÉ

INTRODUCTION: Tumor hypoxia is a centerpiece of disease progression mechanisms such as neoangiogenesis or aggressive hypoxia-resistant malignant cells selection that impacts on radiotherapy strategies. Early identification of regions at risk for recurrence and prognostic-based classification of patients is a necessity to devise tailored therapeutic strategies. We developed an image-based algorithm to spatially map areas of aerobic and anaerobic glycolysis (Glyoxia). METHODS: 18F-FDG and 18F-FMISO PET studies were used in the algorithm to produce DICOM-co-registered representations and maximum intensity projections combined with quantitative analysis of hypoxic volume (HV), hypoxic glycolytic volume (HGV), and anaerobic glycolytic volume (AGV) with CT/MRI co-registration. This was applied to a prospective clinical trial of 10 glioblastoma patients with post-operative, pre-radiotherapy, and early post-radiotherapy 18F-FDG and 18F-FMISO PET and MRI studies. RESULTS: In the 10 glioblastoma patients (5M:5F; age range 51-69 years), 14/18 18F-FMISO PET studies showed detectable hypoxia. Seven patients survived to complete post-radiotherapy studies. The patient with the longest overall survival showed non-detectable hypoxia in both pre-radiotherapy and post-radiotherapy 18F-FMISO PET. The three patients with increased HV, HGV, and AGV volumes after radiotherapy showed 2.8 months mean progression-free interval vs. 5.9 months for the other 4 patients. These parameters correlated at that time point with progression-free interval. Parameters combining hypoxia and glycolytic information (i.e., HGV and AGV) showed more prominent variation than hypoxia-based information alone (HV). Glyoxia-generated images were consistent with disease relapse topology; in particular, one patient had distant relapse anticipated by HV, HGV, and AGV maps. CONCLUSION: Spatial mapping of aerobic and anaerobic glycolysis allows unique information on tumor metabolism and hypoxia to be evaluated with PET, providing a greater understanding of tumor biology and potential response to therapy.


Sujet(s)
Glioblastome , Sujet âgé , Fluorodésoxyglucose F18 , Glioblastome/imagerie diagnostique , Glioblastome/radiothérapie , Glycolyse , Humains , Hypoxie/imagerie diagnostique , Adulte d'âge moyen , Misonidazole , Récidive tumorale locale/imagerie diagnostique , Récidive tumorale locale/radiothérapie , Tomographie par émission de positons , Études prospectives , Radiopharmaceutiques
9.
J Nucl Med ; 59(4): 636-638, 2018 04.
Article de Anglais | MEDLINE | ID: mdl-29326354

RÉSUMÉ

We report the discovery of a systematic miscalibration during the work-up process for site validation of a multicenter clinical PET imaging trial using 68Ga, which manifested as a consistent and reproducible underestimation in the quantitative accuracy (assessed by SUV) of a range of PET systems from different manufacturers at several different facilities around Australia. Methods: Sites were asked to follow a strict preparation protocol to create a radioactive phantom with 68Ga to be imaged using a standard clinical protocol before commencing imaging in the trial. All sites had routinely used 68Ga for clinical PET imaging for many years. The reconstructed image data were transferred to an imaging core laboratory for analysis, along with information about ancillary equipment such as the radionuclide dose calibrator. Fourteen PET systems were assessed from 10 nuclear medicine facilities in Australia, with the aim for each PET system being to produce images within 5% of the true SUV. Results: At initial testing, 10 of the 14 PET systems underestimated the SUV by 15% on average (range, 13%-23%). Multiple PET systems at one site, from two different manufacturers, were all similarly affected, suggesting a common cause. We eventually identified an incorrect factory-shipped dose calibrator setting from a single manufacturer as being the cause. The calibrator setting for 68Ga was subsequently adjusted by the users so that the reconstructed images produced accurate values. Conclusion: PET imaging involves a chain of measurements and calibrations to produce accurate quantitative performance. Testing of the entire chain is simple, however, and should form part of any quality assurance program or prequalifying site assessment before commencing a quantitative imaging trial or clinical imaging.


Sujet(s)
Radio-isotopes du gallium , Résultats fortuits , Tomographie par émission de positons , Dose de rayonnement , Artéfacts , Calibrage , Essais cliniques comme sujet , Humains , Fantômes en imagerie , Reproductibilité des résultats , Sensibilité et spécificité
10.
Theranostics ; 6(12): 2225-2234, 2016.
Article de Anglais | MEDLINE | ID: mdl-27924159

RÉSUMÉ

Background: DS-8273a, an anti-human death receptor 5 (DR5) agonistic antibody, has cytotoxic activity against human cancer cells and induces apoptosis after specific binding to DR5. DS-8273a is currently being used in clinical Phase I trials. This study evaluated the molecular imaging of DR5 expression in vivo in mouse tumor models using SPECT/CT and PET/MRI, as a tool for drug development and trial design. Methods: DS-8273a was radiolabeled with indium-111 and zirconium-89. Radiochemical purity, immunoreactivity, antigen binding affinity and serum stability were assessed in vitro. In vivo biodistribution and pharmacokinetic studies were performed, including SPECT/CT and PET/MR imaging. A dose-escalation study using a PET/MR imaging quantitative analysis was also performed to determine DR5 receptor saturability in a mouse model. Results:111In-CHX-A″-DTPA-DS-8273a and 89Zr-Df-Bz-NCS-DS-8273a showed high immunoreactivity (100%), high serum stability, and bound to DR5 expressing cells with high affinity (Ka, 1.02-1.22 × 1010 M-1). The number of antibodies bound per cell was 32,000. In vivo biodistribution studies showed high and specific uptake of 111In-CHX-A″-DTPA-DS-8273a and 89Zr-Df-Bz-NCS-DS-8273a in DR5 expressing COLO205 xenografts, with no specific uptake in normal tissues or in DR5-negative CT26 xenografts. DR5 receptor saturation was observed in vivo by biodistribution studies and quantitative PET/MRI analysis. Conclusion:89Zr-Df-Bz-NCS-DS-8273a is a potential novel PET imaging reagent for human bioimaging trials, and can be used for effective dose assessment and patient response evaluation in clinical trials.


Sujet(s)
Adénocarcinome/imagerie diagnostique , Adénocarcinome/thérapie , Anticorps/administration et posologie , Radio-isotopes/administration et posologie , Récepteurs de TRAIL/antagonistes et inhibiteurs , Nanomédecine théranostique/méthodes , Zirconium/administration et posologie , Animaux , Lignée cellulaire tumorale , Modèles animaux de maladie humaine , Hétérogreffes , Humains , Indium/administration et posologie , Indium/pharmacocinétique , Imagerie par résonance magnétique , Souris de lignée BALB C , Tomographie par émission de positons , Radio-isotopes/pharmacocinétique , Radiothérapie/méthodes , Tomographie par émission monophotonique , Résultat thérapeutique , Zirconium/pharmacocinétique
11.
J Labelled Comp Radiopharm ; 59(10): 416-23, 2016 08.
Article de Anglais | MEDLINE | ID: mdl-27435268

RÉSUMÉ

The significance of imaging hypoxia with the positron emission tomography ligand [(18) F]FMISO has been demonstrated in a variety of cancers. However, the slow kinetics of [(18) F]FMISO require a 2-h delay between tracer administration and patient scanning. Labeled chloroethyl sulfoxides have shown faster kinetics and higher contrast than [(18) F]FMISO in a rat model of ischemic stroke. However, these nitrogen mustard analogues are unsuitable for routine production and use in humans. Here, we report on the synthesis and in vitro and in vivo evaluation of a novel sulfoxide, which contains an ester moiety for hydrolysis and subsequent trapping in hypoxic cells. Non-decay corrected yields of radioactivity were 1.18 ± 0.24% (n = 27, 2.5 ± 0.5% decay corrected radiochemical yield) based on K[(18) F]F. The radiotracer did not show any defluorination and did not undergo metabolism in an in vitro assay using S9 liver fractions. Imaging studies using an SK-RC-52 tumor model in BALB/c nude mice have revealed that [(18) F]1 is retained in hypoxic tumors and has similar hypoxia selectivity to [(18) F]FMISO. Because of a three times faster clearance rate than [(18) F]FMISO from normoxic tissue, [(18) F]1 has emerged as a promising new radiotracer for hypoxia imaging.


Sujet(s)
Radio-isotopes du fluor , Glycine/analogues et dérivés , Sulfoxydes , Hypoxie tumorale , Animaux , Lignée cellulaire tumorale , Stabilité de médicament , Glycine/composition chimique , Humains , Interactions hydrophobes et hydrophiles , Marquage isotopique , Souris , Imagerie moléculaire , Radiochimie , Sulfoxydes/composition chimique
12.
Mol Imaging ; 152016.
Article de Anglais | MEDLINE | ID: mdl-27457521

RÉSUMÉ

PURPOSE: The aims of the study were to develop and evaluate a novel residualizing peptide for labeling internalizing antibodies with (124)I to support clinical development using immuno-positron emission tomography (PET). METHODS: The anti-epidermal growth factor receptor antibody ch806 was radiolabeled directly or indirectly with isotopes and various residualizing peptides. Azido-derivatized radiolabeled peptides were conjugated to dibenzylcyclooctyne-derivatized ch806 antibody via click chemistry. The radiochemical purities, antigen-expressing U87MG.de2-7 human glioblastoma cell-binding properties, and targeting of xenografts at 72 hours post injection of all radioconjugates were compared. Biodistribution of (124)I-PEG4-tptddYddtpt-ch806 and immuno-PET imaging were evaluated in tumor-bearing mice. RESULTS: Biodistribution studies using xenografts at 72 hours post injection showed that (131)I-PEG4-tptddYddtpt-ch806 tumor uptake was similar to (111)In-CHX-A″-DTPA-ch806. (125)I-PEG4-tptddyddtpt-ch806 showed a lower tumor uptake value but higher than directly labeled (125)I-ch806. (124)I-PEG4-tptddYddtpt-ch806 was produced at 23% labeling efficiency, 98% radiochemical purity, 25.9 MBq/mg specific activity, and 64% cell binding in the presence of antigen excess. Tumor uptake for (124)I-PEG4-tptddYddtpt-ch806 was similar to (111)In-CHX-A″-DTPA-ch806. High-resolution immuno-PET/magnetic resonance imaging of tumors showed good correlation with biodistribution data. CONCLUSIONS: The mixed d/l-enantiomeric peptide, dThr-dPro-dThr-dAsp-dAsp-Tyr-dAsp-dAsp-dThr-dPro-dThr, is suitable for radiolabeling antibodies with radiohalogens such as (124)I for high-resolution immuno-PET imaging of tumors and for evaluation in early-phase clinical trials.


Sujet(s)
Anticorps monoclonaux/pharmacocinétique , Tumeurs du cerveau/imagerie diagnostique , Glioblastome/imagerie diagnostique , Peptides/pharmacocinétique , Animaux , Anticorps monoclonaux/composition chimique , Lignée cellulaire tumorale , Humains , Radio-isotopes de l'iode/composition chimique , Souris , Transplantation tumorale , Peptides/composition chimique , Radiopharmaceutiques/composition chimique , Distribution tissulaire , Tyrosine
13.
MAbs ; 8(4): 775-86, 2016.
Article de Anglais | MEDLINE | ID: mdl-27030023

RÉSUMÉ

IgG has a long half-life through engagement of its Fc region with the neonatal Fc receptor (FcRn). The FcRn binding site on IgG1 has been shown to contain I253 and H310 in the CH2 domain and H435 in the CH3 domain. Altering the half-life of IgG has been pursued with the aim to prolong or reduce the half-life of therapeutic IgGs. More recent studies have shown that IgGs bind differently to mouse and human FcRn. In this study we characterize a set of hu3S193 IgG1 variants with mutations in the FcRn binding site. A double mutation in the binding site is necessary to abrogate binding to murine FcRn, whereas a single mutation in the FcRn binding site is sufficient to no longer detect binding to human FcRn and create hu3S193 IgG1 variants with a half-life similar to previously studied hu3S193 F(ab')2 (t1/2ß, I253A, 12.23 h; H310A, 12.94; H435A, 12.57; F(ab')2, 12.6 h). Alanine substitutions in S254 in the CH2 domain and Y436 in the CH3 domain showed reduced binding in vitro to human FcRn and reduced elimination half-lives in huFcRn transgenic mice (t1/2ß, S254A, 37.43 h; Y436A, 39.53 h; wild-type, 83.15 h). These variants had minimal effect on half-life in BALB/c nu/nu mice (t1/2ß, S254A, 119.9 h; Y436A, 162.1 h; wild-type, 163.1 h). These results provide insight into the interaction of human Fc by human FcRn, and are important for antibody-based therapeutics with optimal pharmacokinetics for payload strategies used in the clinic.


Sujet(s)
Anticorps monoclonaux/composition chimique , Antigènes d'histocompatibilité de classe I/immunologie , Immunoglobuline G/composition chimique , Récepteur Fc/composition chimique , Animaux , Anticorps monoclonaux/immunologie , Anticorps monoclonaux/pharmacologie , Période , Humains , Immunoglobuline G/immunologie , Immunoglobuline G/pharmacologie , /immunologie , Souris , Souris de lignée BALB C , Souris transgéniques , Ingénierie des protéines , Stabilité protéique , Récepteur Fc/immunologie
14.
J Nucl Med ; 57(6): 974-80, 2016 06.
Article de Anglais | MEDLINE | ID: mdl-26940768

RÉSUMÉ

UNLABELLED: Subtype A2 of the erythropoietin-producing hepatocellular tyrosine kinase (EphA2) cell surface receptor is expressed in a range of epithelial cancers. This study evaluated the molecular imaging of EphA2 expression in vivo in mouse tumor models using SPECT/MR and PET/MR and a humanized anti-EphA2 antibody, DS-8895a. METHODS: DS-8895a was labeled with (111)In, (125)I, and (89)Zr and assessed for radiochemical purity, immunoreactivity (Lindmo analysis), antigen-binding affinity (Scatchard analysis), and serum stability in vitro. In vivo biodistribution, imaging, and pharmacokinetic studies were performed with SPECT/MR and PET/MR. A dose-escalation study was also performed to determine EphA2 receptor saturability through tissue and imaging quantitative analysis. RESULTS: All conjugates demonstrated good serum stability and specific binding to EphA2-expressing cells in vitro. In vivo biodistribution studies showed high uptake of (111)In-CHX-A″-DTPA-DS-8895a and (89)Zr-Df-Bz-NCS-DS-8895a in EphA2-expressing xenograft models, with no specific uptake in normal tissues. In comparison, retention of (125)I-DS-8895a in tumors was lower because of internalization of the radioconjugate and dehalogenation. These results were confirmed by SPECT/MR and PET/MR. EphA2 receptor saturation was observed at the 30 mg/kg dose. CONCLUSION: Molecular imaging of tumor uptake of DS-8895a allows noninvasive measurement of EphA2 expression in tumors in vivo and determination of receptor saturation. (89)Zr-Df-Bz-NCS-DS-8895a is suited for human bioimaging trials on the basis of superior imaging characteristics and will inform DS-8895a dose assessment and patient response evaluation in clinical trials.


Sujet(s)
Anticorps monoclonaux humanisés/composition chimique , Transformation cellulaire néoplasique , Tomographie par émission de positons/méthodes , Radio-isotopes , Récepteur EphA2/métabolisme , Tomographie par émission monophotonique/méthodes , Zirconium/composition chimique , Animaux , Anticorps monoclonaux humanisés/immunologie , Anticorps monoclonaux humanisés/pharmacocinétique , Lignée cellulaire tumorale , Déferoxamine/analogues et dérivés , Déferoxamine/composition chimique , Femelle , Humains , Isothiocyanates/composition chimique , Souris , Acide pentétique/composition chimique , Contrôle de qualité , Récepteur EphA2/immunologie , Distribution tissulaire
15.
EJNMMI Res ; 6(1): 26, 2016 Dec.
Article de Anglais | MEDLINE | ID: mdl-26983636

RÉSUMÉ

BACKGROUND: The aim of the study was to explore Fc mutations of a humanised anti-Lewis-Y antibody (IgG1) hu3S193 as a strategy to improve therapeutic ratios for therapeutic payload delivery. METHODS: Four hu3S193 variants (I253A, H310A, H435A and I253A/H310A) were generated via site-directed mutagenesis and radiolabelled with diagnostic isotopes iodine-125 or indium-111. Biodistribution studies in Lewis-Y-positive tumour-bearing mice were used to calculate the dose in tumours and organs for therapeutic isotopes (iodine-131, yttrium-90 and lutetium-177). RESULTS: (111)In-labelled I253A and H435A showed similar slow kinetics (t 1/2ß, 63.2 and 62.2 h, respectively) and a maximum tumour uptake of 33.11 ± 4.05 and 33.69 ± 3.77 percentage injected dose per gramme (%ID/g), respectively. (111)In-labelled I253A/H310A cleared fastest (t 1/2ß, 9.1 h) with the lowest maximum tumour uptake (23.72 ± 0.85 %ID/g). The highest increase in tumour-to-blood area under the curve (AUC) ratio was observed with the metal-labelled mutants ((90)Y and (177)Lu). (177)Lu-CHX-A" DTPA-hu3S193 I253A/H310A (6:1) showed the highest tumour-to-blood AUC ratio compared to wild type (3:1) and other variants and doubling of calculated dose to tumour based on red marrow dose constraints. CONCLUSIONS: These results suggest that hu3S193 Fc can be engineered with improved therapeutic ratios for (90)Y- and (177)Lu-based therapy, with the best candidate being hu3S193 I253A/H310A for (177)Lu-based therapy.

16.
Inorg Chem ; 54(19): 9594-610, 2015 Oct 05.
Article de Anglais | MEDLINE | ID: mdl-26375592

RÉSUMÉ

With the aim of preparing hypoxia-selective imaging and therapeutic agents, technetium(I) and rhenium(I) tricarbonyl complexes with pyridylhydrazone, dipyridylamine, and pyridylaminocarboxylate ligands containing nitrobenzyl or nitroimidazole functional groups have been prepared. The rhenium tricarbonyl complexes were synthesized with short reaction times using microwave irradiation. Rhenium tricarbonyl complexes with deprotonated p-nitrophenyl pyridylhydrazone ligands are luminescent, and this has been used to track their uptake in HeLa cells using confocal fluorescent microscopy. Selected rhenium tricarbonyl complexes displayed higher uptake in hypoxic cells when compared to normoxic cells. A (99m)Tc tricarbonyl complex with a dipyridylamine ligand bearing a nitroimidazole functional group is stable in human serum and was shown to localize in a human renal cell carcinoma (RCC; SK-RC-52) tumor in a mouse.


Sujet(s)
Hypoxie , Composés organométalliques/pharmacocinétique , Rhénium/pharmacocinétique , Technétium/pharmacocinétique , Animaux , Lignée cellulaire tumorale , Imagerie diagnostique , Techniques électrochimiques , Cellules HeLa , Humains , Ligands , Luminescence , Souris , Souris de lignée BALB C , Souris nude , Microscopie de fluorescence , Modèles moléculaires , Structure moléculaire , Composés organométalliques/synthèse chimique , Composés organométalliques/composition chimique , Rhénium/composition chimique , Technétium/composition chimique , Distribution tissulaire
17.
J Clin Oncol ; 33(24): 2609-16, 2015 Aug 20.
Article de Anglais | MEDLINE | ID: mdl-26124477

RÉSUMÉ

PURPOSE: CS-1008 (tigatuzumab) is a humanized, monoclonal immunoglobulin G1 (IgG1) agonistic antibody to human death receptor 5. The purpose of this study was to investigate the impact of CS-1008 dose on the biodistribution, quantitative tumor uptake, and antitumor response in patients with metastatic colorectal cancer (mCRC). PATIENTS AND METHODS: Patients with mCRC who had received at least one course of chemotherapy were assigned to one of five dosage cohorts and infused with a weekly dose of CS-1008. Day 1 and day 36 doses were trace-labeled with indium-111 ((111)In), followed by whole-body planar and regional single-photon emission computed tomography (SPECT) imaging at several time points over the course of 10 days. RESULTS: Nineteen patients were enrolled. (111)In-CS-1008 uptake in tumor was observed in only 12 patients (63%). (111)In-CS-1008 uptake and pharmacokinetics were not affected by dose or repeated drug administration. (111)In-CS-1008 biodistribution showed gradual blood-pool clearance and no abnormal uptake in normal tissue. No anti-CS-1008 antibody development was detected. One patient achieved partial response (3.7 months duration), eight patients had stable disease, and 10 patients had progressive disease. Clinical benefit rate (stable disease + partial response) in patients with (111)In-CS-1008 uptake in tumor was 58% versus 28% in patients with no uptake. An analysis of individual lesions showed that lesions with antibody uptake were one third as likely to progress as those without antibody uptake (P = .07). Death-receptor-5 expression in archived tumor samples did not correlate with (111)In-CS-1008 uptake (P = .5) or tumor response (P = .6). CONCLUSION: Death-receptor-5 imaging with (111)In-CS-1008 reveals interpatient and intrapatient heterogeneity of uptake in tumor, is not dose dependent, and is predictive of clinical benefit in the treatment of patients who have mCRC.


Sujet(s)
Anticorps monoclonaux humanisés/administration et posologie , Anticorps monoclonaux humanisés/pharmacocinétique , Tumeurs colorectales/imagerie diagnostique , Tumeurs colorectales/traitement médicamenteux , Sujet âgé , Sujet âgé de 80 ans ou plus , Études de cohortes , Tumeurs colorectales/métabolisme , Tumeurs colorectales/anatomopathologie , Relation dose-effet des médicaments , Femelle , Humains , Radio-isotopes de l'indium , Mâle , Adulte d'âge moyen , Métastase tumorale , Scintigraphie , Radiopharmaceutiques/administration et posologie , Radiopharmaceutiques/pharmacocinétique , Distribution tissulaire
18.
Mol Pharm ; 11(8): 2855-63, 2014 Aug 04.
Article de Anglais | MEDLINE | ID: mdl-24999533

RÉSUMÉ

Imaging of activated platelets using an activation specific anti-GPIIb/IIIa integrin single-chain antibody (scFvanti-LIBS) conjugated to a positron emitting copper-64 complex of a cage amine sarcophagine chelator (MeCOSar) is reported. This tracer was compared in vitro to a (64)Cu(II) complex of the scFv conjugated to another commonly used macrocycle, DOTA. The scFvanti-LIBS-MeCOSar conjugate was radiolabeled with (64)Cu(II) rapidly under mild conditions and with higher specific activity than scFvanti-LIBS-DOTA. The utility of scFvanti-LIBS-MeCOSar as a diagnostic agent was assessed in vivo in a mouse model of acute thrombosis. The uptake of scFvanti-LIBS-(64)CuMeCOSar in the injured vessel was significantly higher than the noninjured vessel. Positron emission tomography (PET) was used to show accumulation of scFvanti-LIBS-(64)CuMeCOSar with high and specific uptake in the injured vessel. ScFvanti-LIBS-(64)CuMeCOSar is an excellent tool for highly sensitive in vivo detection of activated platelets in PET and has the potential to be used for early diagnosis of acute thrombotic events.


Sujet(s)
Plaquettes/effets des médicaments et des substances chimiques , Chélateurs/composition chimique , Tomographie par émission de positons , Anticorps à chaîne unique/composition chimique , Animaux , Plaquettes/métabolisme , Artères carotides/physiopathologie , Cuivre/composition chimique , Radio-isotopes du cuivre/composition chimique , Imagerie diagnostique , Modèles animaux de maladie humaine , Cytométrie en flux , Composés hétéromonocycliques/composition chimique , Inflammation , Ligands , Spectroscopie par résonance magnétique , Souris , Souris de lignée BALB C , Activation plaquettaire , Radiopharmaceutiques , Thrombose/diagnostic , Microtomographie aux rayons X
19.
Australas Phys Eng Sci Med ; 37(3): 495-503, 2014 Sep.
Article de Anglais | MEDLINE | ID: mdl-24859803

RÉSUMÉ

The scalable XCAT voxelised phantom was used with the GATE Monte Carlo toolkit to investigate the effect of voxel size on dosimetry estimates of internally distributed radionuclide calculated using direct Monte Carlo simulation. A uniformly distributed Fluorine-18 source was simulated in the Kidneys of the XCAT phantom with the organ self dose (kidney ← kidney) and organ cross dose (liver ← kidney) being calculated for a number of organ and voxel sizes. Patient specific dose factors (DF) from a clinically acquired FDG PET/CT study have also been calculated for kidney self dose and liver ← kidney cross dose. Using the XCAT phantom it was found that significantly small voxel sizes are required to achieve accurate calculation of organ self dose. It has also been used to show that a voxel size of 2 mm or less is suitable for accurate calculations of organ cross dose. To compensate for insufficient voxel sampling a correction factor is proposed. This correction factor is applied to the patient specific dose factors calculated with the native voxel size of the PET/CT study.


Sujet(s)
Simulation numérique , Méthode de Monte Carlo , Interprétation d'images radiographiques assistée par ordinateur , Radiométrie/méthodes , Relation dose-effet des rayonnements , Fluorodésoxyglucose F18 , Humains , Rein/imagerie diagnostique , Fantômes en imagerie , Scintigraphie
20.
Nucl Med Biol ; 41(5): 419-25, 2014.
Article de Anglais | MEDLINE | ID: mdl-24767600

RÉSUMÉ

[¹8F]FMISO is the most widely validated PET radiotracer for imaging hypoxic tissue. However, as a result of the pharmacokinetics of [¹8F]FMISO a 2h wait between tracer administration and patient scanning is required for optimal image acquisition. In order to develop hypoxia imaging agents with faster kinetics, we have synthesised and evaluated several F-18 labelled anilino sulfoxides. In this manuscript we report on the synthesis, in vitro and in vivo evaluation of a novel fluoroethyltriazolyl propargyl anilino sulfoxide. The radiolabelling of the novel tracer was achieved via 2-[¹8F]fluoroethyl azide click chemistry. Radiochemical yields were 23 ± 4% based on 2-[¹8F]fluoroethyl azide and 7 ± 2% based on K[¹8F]F. The radiotracer did not undergo metabolism or defluorination in an in vitro assay using S9 liver fractions. Imaging studies using SK-RC-52 tumors in BALB/c nude mice have indicated that the tracer may have a higher pO2 threshold than [¹8F]FMISO for uptake in hypoxic tumors. Although clearance from muscle was faster than [¹8F]FMISO, uptake in hypoxic tumors was slower. The average tumor to muscle ratio at 2h post injection in large, hypoxic tumors with a volume greater than 686 mm³ was 1.7, which was similar to the observed ratio of 1.75 for [¹8F]FMISO. Although the new tracer showed improved pharmacokinetics when compared with the previously synthesised sulfoxides, further modifications to the chemical structure need to be made in order to offer significant in vivo imaging advantages over [¹8F]FMISO.


Sujet(s)
Tumeurs du rein/anatomopathologie , Tomographie par émission de positons/méthodes , Sulfoxydes , Animaux , Hypoxie cellulaire , Lignée cellulaire tumorale , Humains , Interactions hydrophobes et hydrophiles , Marquage isotopique , Souris , Radiochimie , Sulfoxydes/composition chimique , Sulfoxydes/pharmacocinétique
SÉLECTION CITATIONS
DÉTAIL DE RECHERCHE