1.
Sci Rep ; 12(1): 22635, 2022 12 31.
Article de Anglais | MEDLINE | ID: mdl-36587057

RÉSUMÉ

Congenital Diaphragmatic Hernia (CDH) is a diaphragm defect associated with lung hypoplasia and ventilation inhomogeneity (VI). The affected neonates are usually born with respiratory failure and require mechanical ventilation after birth. However, significant interindividual VI differences make ventilation difficult. So far, there are no clinical methods of VI assessment that could be applied to optimize ventilation at the bedside. A new VI index is a ratio of time constants T1/T2 of gas flows in both lungs. Pressure-controlled ventilation simulations were conducted using an infant hybrid (numerical-physical) respiratory simulator connected to a ventilator. The parameters of the respiratory system model and ventilator settings were based on retrospective clinical data taken from three neonates (2, 2.6, 3.6 kg) treated in the Paediatric Teaching Clinical Hospital of the Medical University of Warsaw. We searched for relationships between respiratory system impedance (Z) and ventilation parameters: work of breathing (WOB), peak inspiratory pressure (PIP), and mean airway pressure (MAP). The study showed the increased VI described by the T1/T2 index value highly correlated with elevated Z, WOB, PIP and MAP (0.8-0.9, the Spearman correlation coefficients were significant at P < 0.001). It indicates that the T1/T2 index may help to improve the ventilation therapy of CDH neonates.


Sujet(s)
Hernies diaphragmatiques congénitales , Humains , Nouveau-né , Nourrisson , Enfant , Hernies diaphragmatiques congénitales/thérapie , Études rétrospectives , Poumon , Ventilation artificielle/méthodes , Respiration
2.
Sci Rep ; 12(1): 14038, 2022 08 18.
Article de Anglais | MEDLINE | ID: mdl-35982198

RÉSUMÉ

We assessed the influence of systemic lidocaine administration on ventilatory and circulatory parameters, and the pneumoperitoneum impact on the cardiopulmonary system during a laparoscopic appendectomy in children. A single-center parallel single-masked randomized controlled study was carried out with 58 patients (3-17 years). Intravenous lidocaine bolus of 1.5 mg/kg over 5 min before induction of anesthesia followed by lidocaine infusion at 1.5 mg/kg/h intraoperatively. Respiratory system compliance (C, C/kg), Ppeak-PEEP and Pulse rate (Pulse), systolic, diastolic and mean blood pressure (NBPs, NBPd, NBPm), assessed in the Lidocaine and Control group, at the: beginning (P1), minimum lung compliance (P2) and at the end of surgery (P3) were compared. The respiratory/hemodynamic parameters did not differ between the groups at any stage of operation. Blood Pressure and Ppeak-PEEP were significantly higher at the P2 compared to P1 and P3 stages (P < 0.001, 1 - ß ≥ 0.895) that correlated with lung compliance changes: C/kg vs. NBPs and Ppeak-PEEP (- 0.42, - 0.84; P < 0.001); C vs. Pulse and Ppeak-PEEP (- 0.48, - 0.46; P < 0.001). Although an increase in intraabdominal pressure up to 12(15) mmHg causes significant changes in hemodynamic/respiratory parameters, there appears to be no risk of fatal reactions in 1E, 2E ASA patients. Systemic lidocaine administration doesn't alleviate circulatory/respiratory alterations during pneumoperitoneum. No lidocaine related episode of anaphylaxis, systemic toxicity, circulatory disturbances or neurological impairment occurred.ClinicalTrials.gov: 22/03/2019.Trial registration number: NCT03886896.


Sujet(s)
Laparoscopie , Pneumopéritoine , Appendicectomie/effets indésirables , Enfant , Hémodynamique , Humains , Laparoscopie/effets indésirables , Lidocaïne/effets indésirables , Appareil respiratoire
3.
Artif Organs ; 41(12): 1099-1108, 2017 Dec.
Article de Anglais | MEDLINE | ID: mdl-28621816

RÉSUMÉ

The aim of this work is to study pediatric pneumatic ventricle (PVAD) performance, versus VAD rate (VADR) and native heart rate (HR) ratio Rr (VADR/HR). The study uses a hybrid model of the cardiovascular system (HCS). HCS consists of a computational part (a lumped parameter model including left and right ventricles, systemic and pulmonary arterial and venous circulation) interfaced to a physical part. This permits the connection of a VAD (15 mL PVAD). Echocardiographic and hemodynamic data of a pediatric patient (average weight 14.3 kg, HR 100 bpm, systemic pressure 75/44 mm Hg, CO 1.5 L/min) assisted apically with asynchronous PVAD were used to set up a basal condition in the model. After model tuning, the assistance was started, setting VAD parameters (ejection and filling pressures, systole duration) to completely fill and empty the PVAD. The study was conducted with constant HR and variable VADR (50-120, step 10, bpm). Experiments were repeated for two additional patients' HRs, 90 and 110 bpm and for two values of systemic arterial resistance (Ras ) and Emax . Experimental data were collected and stored on disk. Analyzed data include average left and right ventricular volumes (LVV, RVV), left ventricular flow (LVF), VAD flow (VADF), and total cardiac output (COt). Data were analyzed versus Rr. LVV and RVV are sensitive to Rr and a left ventricular unloading corresponds in general to a right ventricular loading. In the case of asynchronous assistance, frequency beats are always present and the beat rate is equal to the difference between HR and VADR. In the case of pulsatile asynchronous LVAD assistance, VADR should be chosen to minimize frequency beat effects and right ventricular loading and to maximize left ventricular unloading.


Sujet(s)
Dispositifs d'assistance circulatoire , Hémodynamique , Modèles cardiovasculaires , Débit cardiaque , Enfant , Conception d'appareillage , Humains , Écoulement pulsatoire , Résistance vasculaire , Fonction ventriculaire
4.
Artif Organs ; 38(6): 456-68, 2014 Jun.
Article de Anglais | MEDLINE | ID: mdl-24117988

RÉSUMÉ

Long-term mechanical circulatory assistance opened new problems in ventricular assist device-patient interaction, especially in relation to autonomic controls. Modeling studies, based on adequate models, could be a feasible approach of investigation. The aim of this work is the exploitation of a hybrid (hydronumerical) cardiovascular simulator to reproduce and analyze in vivo experimental data acquired during a continuous flow left ventricular assistance. The hybrid cardiovascular simulator embeds three submodels: a computational cardiovascular submodel, a computational baroreflex submodel, and a hydronumerical interface submodel. The last one comprises two impedance transformers playing the role of physical interfaces able to provide a hydraulic connection with specific cardiovascular sites (in this article, the left atrium and the ascending/descending aorta). The impedance transformers are used to connect a continuous flow pump for partial left ventricular support (Synergy Micropump, CircuLite, Inc., Saddlebrooke, NJ, USA) to the hybrid cardiovascular simulator. Data collected from five animals in physiological, pathological, and assisted conditions were reproduced using the hybrid cardiovascular simulator. All parameters useful to characterize and tune the hybrid cardiovascular simulator to a specific hemodynamic condition were extracted from experimental data. Results show that the simulator is able to reproduce animal-specific hemodynamic status both in physiological and pathological conditions, to reproduce cardiovascular left ventricular assist device (LVAD) interaction and the progressive unloading of the left ventricle for different pump speeds, and to investigate the effects of the LVAD on baroreflex activity. Results in chronic heart failure conditions show that an increment of LVAD speed from 20 000 to 22 000 rpm provokes a decrement of left ventricular flow of 35% (from 2 to 1.3 L/min). Thanks to its flexibility and modular structure, the simulator is a platform potentially useful to test different assist devices, thus providing clinicians additional information about LVAD therapy strategy.


Sujet(s)
Baroréflexe , Simulation numérique , Défaillance cardiaque/thérapie , Dispositifs d'assistance circulatoire , Modèles cardiovasculaires , Fonction ventriculaire gauche , Animaux , Modèles animaux de maladie humaine , Défaillance cardiaque/diagnostic , Défaillance cardiaque/physiopathologie , Hémodynamique , Humains , Conception de prothèse , Reproductibilité des résultats , Ovis , Suidae , Facteurs temps
5.
Respiration ; 82(4): 377-85, 2011.
Article de Anglais | MEDLINE | ID: mdl-21921672

RÉSUMÉ

BACKGROUND: Measurement of intrapleural pressure is useful during various pleural procedures. However, a pleural manometer is rarely available. OBJECTIVES: The aim of this study was to (1) construct an electronic pleural manometer, (2) assess the accuracy of the measurements done with the new device, (3) calculate the costs of the manometer construction and (4) perform an initial evaluation of the device in a clinical setting. METHODS: Only widely accessible elements were used to construct the device. A vascular pressure transducer was used to transform pressure into an electronic signal. Reliability of the measurements was evaluated in a laboratory setting in a prospective, single-blind manner by comparing the results with those measured by a water manometer. Functionality of the device was assessed during therapeutic thoracentesis. The cost of the new pleural manometer was calculated. RESULTS: We built a small, portable device which can precisely measure intrapleural pressure. The measurement results showed very high agreement with those registered with a water manometer (r = 0.999; p < 0.001). The initial evaluation of the electronic manometer during therapeutic thoracentesis showed it was easy to use. The total time needed for 6 measurements after withdrawal of different volumes of pleural fluid in 1 patient did not exceed 6 min. The total cost of the device was calculated to be <2,000 EUR. CONCLUSIONS: In the face of very limited offer of commercially available pleural manometers, it is possible to successfully construct a self-made, reliable, electronic pleural manometer at modest costs. The device is easy to use and enables data display and storage in the personal computer.


Sujet(s)
Manométrie/instrumentation , Plèvre/physiopathologie , Épanchement pleural/physiopathologie , Électronique , Conception d'appareillage , Humains , Manométrie/économie , Manométrie/méthodes , Études prospectives , Reproductibilité des résultats , Méthode en simple aveugle