Your browser doesn't support javascript.
loading
Montrer: 20 | 50 | 100
Résultats 1 - 2 de 2
Filtrer
Plus de filtres










Base de données
Gamme d'année
1.
Magn Reson Med ; 90(1): 79-89, 2023 07.
Article de Anglais | MEDLINE | ID: mdl-36912481

RÉSUMÉ

PURPOSE: To explore the feasibility of measuring ventilation defect percentage (VDP) using 19 F MRI during free-breathing wash-in of fluorinated gas mixture with postacquisition denoising and to compare these results with those obtained through traditional Cartesian breath-hold acquisitions. METHODS: Eight adults with cystic fibrosis and 5 healthy volunteers completed a single MR session on a Siemens 3T Prisma. 1 H Ultrashort-TE MRI sequences were used for registration and masking, and ventilation images with 19 F MRI were obtained while the subjects breathed a normoxic mixture of 79% perfluoropropane and 21% oxygen (O2 ). 19 F MRI was performed during breath holds and while free breathing with one overlapping spiral scan at breath hold for VDP value comparison. The 19 F spiral data were denoised using a low-rank matrix recovery approach. RESULTS: VDP measured using 19 F VIBE and 19 F spiral images were highly correlated (r = 0.84) at 10 wash-in breaths. Second-breath VDPs were also highly correlated (r = 0.88). Denoising greatly increased SNR (pre-denoising spiral SNR, 2.46 ± 0.21; post-denoising spiral SNR, 33.91 ± 6.12; and breath-hold SNR, 17.52 ± 2.08). CONCLUSION: Free-breathing 19 F lung MRI VDP analysis was feasible and highly correlated with breath-hold measurements. Free-breathing methods are expected to increase patient comfort and extend ventilation MRI use to patients who are unable to perform breath holds, including younger subjects and those with more severe lung disease.


Sujet(s)
Mucoviscidose , Troubles respiratoires , Adulte , Humains , Volontaires sains , Études de faisabilité , Respiration , Poumon , Imagerie par résonance magnétique/méthodes , Mucoviscidose/imagerie diagnostique , Oxygène
2.
J Clin Med ; 11(20)2022 Oct 19.
Article de Anglais | MEDLINE | ID: mdl-36294480

RÉSUMÉ

The availability of highly effective CFTR modulators is revolutionizing the treatment of cystic fibrosis (CF) and drastically improving outcomes. MRI-based imaging modalities are now emerging as highly sensitive endpoints, particularly in the setting of mild lung disease. Adult CF patients were recruited from a single center prior to starting treatment with E/T/I. The following studies were obtained before and after one month on treatment: spirometry, multiple breath nitrogen washout (MBW), 1H UTE MRI (structural images) and 19F MRI (ventilation images). Changes between visits were calculated, as were correlations between FEV1, lung clearance index (LCI), MRI structural scores, and MRI-based ventilation descriptors. Eight subjects had complete datasets for evaluation. Consistent with prior clinical trials, FEV1 and LCI improved after 28 days of E/T/I use. 1H UTE MRI detected improvements in bronchiectasis/airway wall thickening score and mucus plugging score after 28 days of therapy. 19F MRI demonstrated improvements in fractional lung volume with slow gas washout time (FLV↑tau2) and ventilation defect percentage (VDP). Improvements in FLV↑tau2 and VDP correlated with improvement in FEV1 (r = 0.81 and 0.86, respectively, p < 0.05). This observational study establishes the ability of 19F MRI and 1H UTE MRI to detect improvements in lung structure and function after E/T/I treatment. This study supports further development of 19F MRI and 1H UTE MRI as outcome measures for cystic fibrosis research and drug development.

SÉLECTION CITATIONS
DÉTAIL DE RECHERCHE