Your browser doesn't support javascript.
loading
Montrer: 20 | 50 | 100
Résultats 1 - 6 de 6
Filtrer
1.
Life (Basel) ; 13(2)2023 Feb 19.
Article de Anglais | MEDLINE | ID: mdl-36836939

RÉSUMÉ

BACKGROUND: The benefit of prophylactic left ventricular (LV) unloading during venoarterial extracorporeal membrane oxygenation (VA-ECMO) in selected patients at risk of developing LV distension remains unclear. METHODS: We enrolled 136 patients treated with Impella pump decompression during VA-ECMO therapy for refractory cardiogenic shock. Patients were stratified by specific indication for LV unloading in the prophylactic vs. bail-out group. The bail-out unloading strategy was utilized to treat LV distension in VA-ECMO afterload-associated complications. The primary endpoint was all-cause 30-day mortality after VA-ECMO implantation. The secondary endpoint was successful myocardial recovery, transition to durable mechanical circulatory support (MCS), or heart transplantation. RESULTS: After propensity score matching, prophylactic unloading was associated with a significantly lower 30-day mortality risk (risk ratio 0.38, 95% confidence interval 0.23-0.62, and p < 0.001) and a higher probability of myocardial recovery (risk ratio 2.9, 95% confidence interval 1.48-4.54, and p = 0.001) compared with the bail-out strategy. Heart transplantation or durable MCS did not differ significantly between groups. CONCLUSIONS: Prophylactic unloading compared with the bail-out strategy may improve clinical outcomes in selected patients on VA-ECMO. Nevertheless, randomized trials are needed to validate these results.

2.
ESC Heart Fail ; 8(2): 1253-1262, 2021 04.
Article de Anglais | MEDLINE | ID: mdl-33480186

RÉSUMÉ

AIMS: Heart transplantation (HTx) represents optimal care for advanced heart failure. Left ventricular assist devices (LVADs) are often needed as a bridge-to-transplant (BTT) therapy to support patients during the wait for a donor organ. Prolonged support increases the risk for LVAD complications that may affect the outcome after HTx. METHODS AND RESULTS: A total of 342 patients undergoing HTx after LVAD as BTT in a 10-year period in two German high-volume HTx centres were retrospectively analysed. While 73 patients were transplanted without LVAD complications and with regular waiting list status (T, n = 73), the remaining 269 patients were transplanted with high urgency status (HU) and further divided with regard to the observed leading LVAD complications (infection: HU1, n = 91; thrombosis: HU2, n = 32; stroke: HU3, n = 38; right heart failure: HU4, n = 41; arrhythmia: HU5, n = 23; bleeding: HU6, n = 18; device malfunction: HU7, n = 26). Postoperative hospitalization was prolonged in patients with LVAD complications. Analyses of perioperative morbidity revealed no differences regarding primary graft dysfunction, renal failure, and neurological events except postoperative infections. Short-term survival, as well as Kaplan-Meier survival analysis, indicated comparable results between the different study groups without disadvantages for patients with LVAD complications. CONCLUSIONS: Left ventricular assist device therapy can impair the outcome after HTx. However, the occurrence of LVAD complications may not impact on outcome after HTx. Thus, we cannot support the prioritization or discrimination of HTx candidates according to distinct mechanical circulatory support-associated complications. Future allocation strategies have to respect that device-related complications may define urgency but do not impact on the outcome after HTx.


Sujet(s)
Transplantation cardiaque , Dispositifs d'assistance circulatoire , Humains , Études rétrospectives , Résultat thérapeutique , Listes d'attente
3.
J Card Surg ; 35(8): 1832-1839, 2020 Aug.
Article de Anglais | MEDLINE | ID: mdl-32557925

RÉSUMÉ

BACKGROUND: The clinical profile of left ventricular assist device (LVAD) candidates is rapidly changing, with increasing proportion of patients in more stable clinical conditions. However, early postoperative right ventricular failure (eRVF) is still one of the cornerstones associated with increased mortality and the preoperative recognition of associated risk factors remains challenging. The aim of this study was to identify predictive parameters for eRVF after LVAD implantation in patients with preoperative intermediate Intermacs (InM) risk profile 3-5. METHODS: Preoperative laboratory, echocardiography, and right heart catheterization data collected from 80 patients with InM profile 3-5 before LVAD implantation were retrospectively tested with respect to their ability to predict the risk for eRVF after the implantation of a continuous-flow LVAD. RESULTS: Preoperative higher bilirubin and blood urea nitrogen (BUN) levels, higher Model for End-stage Liver Disease score, lower estimated glomerular filtration rate, and higher central venous pressure to pulmonary capillary wedge pressure ratio (CVP/PCWP) were associated to higher risk of eRVF. Regarding the echocardiographic assessment, higher end diastolic linear dimensions of the RV, higher basal end diastolic RV linear dimension to LV ratio, severe tricuspid regurgitation, lower tricuspid annular plane systolic excursion, and lower RV fractional area contraction identified patients with higher risk for eRVF. In the multivariable analysis, a CVP/CPWP > 0.55 (odds ratio [OR]: 4, 95% confidence interval [CII]: 1.4-11.8;P = .01) and BUN > 44.5 mg/dL (OR: 6.6, 95% CI: 1.51-23; P = .011) independently predicted the risk of eRVF. CONCLUSION: Preoperative BUN > 44.5 mg/dL and CVP/PCWP > 0.55 are associated to an increased risk of eRVF following LVAD implantation in intermediate InM patients.


Sujet(s)
Défaillance cardiaque/étiologie , Dispositifs d'assistance circulatoire/effets indésirables , Dysfonction ventriculaire droite/étiologie , Azote uréique sanguin , Évolution de la maladie , Ventricules cardiaques , Humains , Période préopératoire , Pression artérielle pulmonaire d'occlusion , Facteurs de risque
4.
Transpl Immunol ; 41: 27-31, 2017 03.
Article de Anglais | MEDLINE | ID: mdl-28167272

RÉSUMÉ

OBJECTIVES: Identifying patients at risk for impaired long-term survival after heart transplantation (HT) remains a clinical challenge. The aim of this analysis was to investigate whether the gene expression profiling test AlloMap® is related to long-term survival after HT. METHODS: 46 patients who underwent HT between 2006 and 2007 who were originally included into the CARGO II trial at our institution were investigated. Patients were divided in two groups according to an increase or decrease of the AlloMap® score between 6 and 9months after HT. The primary endpoint of this study was long-term all-cause mortality. RESULTS: 23 patients showed an increase of the AlloMap® score between 6 and 9months after HT whereas the remaining 23 patients presented with a decrease of the score. After a median follow-up time of 8.1years (interquartile range 7.6-8.6), all-cause mortality was significantly elevated in patients with an AlloMap® increase compared with patients who showed a decrease of the score (log-rank p=0.005). A ratio of the AlloMap® at 9months to 6months of 1.02 or less was associated with a negative predictive value for all-cause mortality of 100%. CONCLUSIONS: Dynamic changes of the AlloMap® score between 6 and 9months after HT were strongly related to all-cause long-term survival after HT. These results suggest that AlloMap® potentially displays a useful tool to estimate the patients' risk for long-term mortality.


Sujet(s)
Régulation de l'expression des gènes , Défaillance cardiaque , Transplantation cardiaque , Adulte , Sujet âgé , Survie sans rechute , Femelle , Études de suivi , Analyse de profil d'expression de gènes , Défaillance cardiaque/métabolisme , Défaillance cardiaque/mortalité , Défaillance cardiaque/chirurgie , Humains , Mâle , Adulte d'âge moyen , Valeur prédictive des tests , Taux de survie
5.
Eur Heart J Cardiovasc Imaging ; 17(12): 1385-1393, 2016 Dec.
Article de Anglais | MEDLINE | ID: mdl-26758411

RÉSUMÉ

AIMS: New-onset conduction disturbances still represent a considerable problem after transcatheter aortic valve implantation (TAVI). The aim of this study was to identify calcification patterns with an elevated risk for permanent pacemaker implantation (PPI) after TAVI and investigate underlying mechanisms in an ex vivo setting. METHODS AND RESULTS: One hundred and sixty-two patients who underwent TAVI with the Edwards SAPIEN XT® or Medtronic CoreValve® at our institution were analysed. The calcium load of the device landing zone was quantified with 3mensio®, and calcium patterns with an elevated risk for PPI were identified. Ex vivo simulations of balloon valvuloplasty were performed in 3D-printed silicone annuli of patients matching the identified risk profile. Patients with a calcium load of the left coronary cusp (LCC) above 209 mm3 had a higher rate of PPI than patients below this threshold (16.7 vs. 2.6%, P = 0.003). Multivariate regression revealed pre-existing right bundle branch block (RBBB) and increased LCC calcification as independent predictors for PPI. Simulation of the TAVI procedure in a silicone annulus revealed an off-centreline shift of the valvuloplasty balloon and transcatheter heart valve away from the LCC towards the commissure between right- and non-coronary cusp. CONCLUSION: Pre-existing RBBB and elevated LCC calcification were identified as independent predictors for PPI. These two risk factors enabled us to distinguish between patients according to their risk for PPI after TAVI. Ex vivo simulations suggested an off-centreline shift of the balloon as a possible explanation.


Sujet(s)
Sténose aortique/imagerie diagnostique , Sténose aortique/chirurgie , Entraînement électrosystolique/méthodes , Échocardiographie tridimensionnelle/méthodes , Interprétation d'images assistée par ordinateur , Remplacement valvulaire aortique par cathéter/méthodes , Sujet âgé , Analyse de variance , Sténose aortique/mortalité , Calcium/métabolisme , Études de cohortes , Intervalles de confiance , Électrocardiographie/méthodes , Femelle , Humains , Mâle , Analyse multifactorielle , Odds ratio , Pacemaker , Complications postopératoires/imagerie diagnostique , Complications postopératoires/thérapie , Pronostic , Études prospectives , Appréciation des risques , Taux de survie , Remplacement valvulaire aortique par cathéter/effets indésirables
6.
Eur Heart J Cardiovasc Imaging ; 17(5): 576-84, 2016 May.
Article de Anglais | MEDLINE | ID: mdl-26160399

RÉSUMÉ

AIMS: Calcification of the device landing zone is linked to paravalvular regurgitation after transcatheter aortic valve implantation (TAVI). The mechanisms remain incompletely understood and the performance of next-generation transcatheter heart valves (THV) has not been investigated. We evaluated the impact of calcification patterns on residual aortic regurgitation (AR) after TAVI with different THV in patients with severe aortic stenosis. METHODS AND RESULTS: TAVI was performed in 537 patients at two centres. Devices implanted were the Edwards Sapien XT (n = 254), Medtronic CoreValve (n = 123), JenaValve (n = 62), Medtronic Engager (n = 56), and Symetis Acurate (n = 42) prostheses. Calcification of the device landing zone was retrospectively assessed from contrast-enhanced multidetector computed tomography data and correlated with echocardiographic and clinical data. Calcium volumes of the aortic valve and left-ventricular outflow tract were associated with residual AR: No AR, 604 mm(3) (inter-quartile range, IQR 349-916); trace AR, 639 mm(3) (IQR 368-948); mild AR, 710 mm(3) (IQR 412-2078); ≥moderate AR, 1041 mm(3) (IQR 791-1417, P = 0.001). Device landing zone calcium, particularly if located in the left-ventricular outflow tract, and a low cover index were predictive of AR. Differences in the incidence of AR were observed with regard to THV type. Higher calcium volume was associated with the need for post-dilation (n = 134, median 852 [IQR 342-945] vs. 604 [IQR 542-1207] mm(3), P < 0.001). CONCLUSION: Calcification of the device landing zone, particularly if located inferior to the annulus, was independently associated with residual AR after TAVI with all evaluated THV; however, the incidence of paravalvular leakage differed significantly between the devices implanted.


Sujet(s)
Insuffisance aortique/imagerie diagnostique , Sténose aortique/imagerie diagnostique , Sténose aortique/chirurgie , Calcinose/imagerie diagnostique , Calcinose/chirurgie , Échocardiographie/méthodes , Tomodensitométrie multidétecteurs/méthodes , Remplacement valvulaire aortique par cathéter , Sujet âgé , Sujet âgé de 80 ans ou plus , Cathétérisme cardiaque/méthodes , Produits de contraste/pharmacologie , Femelle , Allemagne , Prothèse valvulaire cardiaque , Implantation de valve prothétique cardiaque/méthodes , Humains , Mâle , Biais de l'observateur , Valeur prédictive des tests , Reproductibilité des résultats , Études rétrospectives , Sensibilité et spécificité , Remplacement valvulaire aortique par cathéter/méthodes
SÉLECTION CITATIONS
DÉTAIL DE RECHERCHE
...